Constant climate chambers

Similar documents
Constant climate chambers

Constant climate chamber with humidity

Constant climate chambers

Constant climate chamber with ICH-compliant illumination

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Constant climate chambers

KMF Environmental test chamber for constant climate

Constant climate chambers

Environmental simulation chamber for complex alternating climate profiles

Plant growth chambers

Constant climate chambers

Constant climate chambers

New Generation KBF 240 series

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Model KBF 240 Constant climate chambers with large temperature / humidity range

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Vacuum drying oven for non-flammable solvents

Model KBWF 240 Growth chambers with light and humidity

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Safety vacuum drying oven for flammable solvents

Model KBWF 720 Growth chambers with light and humidity

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

VD 53 - Vacuum drying oven for non-flammable solvents

Constant climate chambers

Constant climate chambers. Always the right climate KBF KBF P KBF LQC KMF series

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

BINDER Industrial. Product Catalog

Model C 170 CO 2 incubators with hot air sterilization

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Product Highlights. BINDER Scientific with New Avantgarde.Line Products

Standard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series

ULTRA.GUARD ultra low temperature freezer

Drying and heating chambers

Vacuum drying VD VDL series

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

STABILITY ICH. ICH Stability Tests

BINDER Product catalog

FITOCLIMA 600 & 1200 STABILITY

FITOCLIMA 600 & 1200 STABILITY

FITOCLIMA 600 & 1200 PHARMA

CO₂ incubators. C CB series

BINDER Scientific Product Catalog

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Drying and heating chambers. Series ED FD FED FP M

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Protect your research

CO₂ incubators. C CB series

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Vacuum drying chambers. VD VDL series

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Laboratory Refrigerator/Deep Freezer TC 802

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Chromatographic Air circulated Refrigerator, two-door TC 603

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Fitoclima Pharma. Stability and Photostability Chambers for the pharmaceutical industry

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

ICH260C. Climate Chamber. Product specification

ICH110. Climate Chamber. Product specification

creating the right atmosphere NEW SERIES Galaxy Plus 170 litre CO 2 Incubators Advanced design for optimum results

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTING

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

Stability Testing according to GMP & FDA

Environmental Chambers

ICH750L. Climate Chamber. Product specification

ENVAIR lab CO2 Tri-Gas Incubator

Photo Stability Chamber

Reproducible Climate...

NEW GENERATION. Efficient use of valuable space INCUBATORS

Long Term Storage Cabinet

6 POINTS TO CONSIDER WHEN PURCHASING A CONSTANT CLIMATE CHAMBER IN THE PHARMACEUTICAL INDUSTRY BUYER S GUIDE

SDR Dry Room. Outstanding performance

Stability Chambers & Rooms

Chromatographic Air circulated Refrigerator, two-door TC 603

EC 160 CO 2. Incubator

Stability Studies? Walk in Stability Chamber BUY RENT SERVICE. Thermolab is a one stop solution for all your stability requirements

Environmental Chambers Series: reach-in & benchtop capacities

FITOCLIMA ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER

Environmental Chambers. 2-Door & 3-Door Extra Large Capacity

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

XSD Dry Cabinet

Environmental Chambers

Digital, not analog: One manifold for all refrigeration systems.

Stability & Shelf Life

ZL Laboratory freezers

HettCube INCUBATORS SUSTAINABLE. ERGONOMIC. HIGH QUALITY. INCUBATOR. Find out more by visiting:

XSD Dry Cabinet

DOUBLE DOOR FREEZER.

HSD Dry Cabinet

XSD Dry Cabinet. Outstanding performance. The XSD series has an outstanding performance for drying moisture sensitive components and pcb s.

Thermo Scientific Forma Environmental Chambers. Controlled Temperature Storage Solutions

FitoClima / FitoTerm SOL chambers

XSD Dry Cabinet

FROILABO offers a full range of incubators with natural convection, air forced or forced cooling to cover most laboratory applications.

REFRIGERATOR M E D I C A L.

Sunrise the beginning of a brand new day

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY REACH-IN CHAMBERS FOR ENVIRONMENTAL TESTING

Humidity Chambers HCP

Transcription:

KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions. From programming to documentation, it meets all critical requirements. Advantages: Long-term stable test conditions Independent of the water supply Complete solution: Temperature/humidity simulation in one chamber Areas of application: Cosmetics Industry Food / Beverage Pharmaceuticals Industry Packaging Industry

Customer benefits Features Customer benefits Characteristics APT.line climate technology Same test conditions throughout the chamber interior Independent of specimen size and quantity APT.line Constant and gentle circulation of air through large-surface side walls even under a full load Homogeneous climate conditions throughout test specimens Water supply Humidification system Cooling system Standard equipment Controller Qualification Accessories and Services Flexible solution independent of water supply and installation site Easy plug-and-play handling Very accurately measured values Minimal maintenance requirements FDA-compliant test results Reliable test results even under extreme climate and site conditions Stable, long-term tests according to GLP/GMP Large power reserves, e.g. for lighting applications No extra costs Chamber is easily moved on casters Condensation-free glass door for clear viewing and constant climate All measured values read at a glance Convenient documentation Easy operation Convenient HMI (Human Machine Interface) FDA- and GLP/GMP-compliant documentation Maximum process stability FDA approved for several years Complete solution Everything from one source BINDER Service is always nearby Suitable for any water quality Direct connection to the domestic water system Convenient water treatment with BINDER PURE AQUA SERVICE Sewage pump for discharges up to 1 m in height Vapor pressure humidification for fast response times Drift-free, capacitive humidity sensor Short recovery time after door opening Powerful compressor cooling system for ambient temperatures up to 32 C No freezing thanks to double evaporator plate Comprehensive standards Ethernet interface Access port diameter 30 mm Casters from 240 l volume Inner glass door with seal and double outer door seal Door heated against condensation MCS screen controller 25 program memory Digital continuous-line recorder for monitoring limits Alarm function More than 10 years of experience with: GLP/GMP, IQ, Q, PQ, DQ FDA-compliant software APT-CM Years of proven and recognized validation and documentation materials Various options: BINDER Data Logger Kits, GLP compliance, access ports in various sizes and positions, object temperature measurement Worldwide service network

Performance characteristics Electronically controlled APT.line preheating chamber with cooling system assuring temperature accuracy and reproducible results Temperature range 0 C to 70 C (without humidity) Temperature range 10 C to 70 C (with humidity) Humidity range 10% to 80% RH MCS controller with 25 storable programs of 100 sections each for a maximum of 500 program segments User-friendly LCD screen Easy-to-read menu guide Integrated electronic chart recorder Variety of options for the graphic display of process parameters Real-time clock Electronically controlled humidification and dehumidification system with capacitive humidity sensor Suitable for stability tests according to ICH guideline Q1A (R2) Inner glass door with seal Independent temperature safety device class 3.1 (DIN 12880) with optical and audible temperature alarm Access port with silicone plug Ø 30 mm, left side Complete safety connection kit for water supply and drainage, including water hose, (total length 6 m) Ethernet interface for communication software APT-CM DataControlSystem 2 shelves, stainless steel BINDER test certificate

Specifications KBF 240 (E5.2) Exterior dimensions Temperature-humidity chart Width (mm) 925 Height (incl. casters) (mm) 1460 Depth (incl. door handle, I-triangle, connection 50 mm) (mm) 800 Wall clearance, rear (mm) 100 Wall clearance, side (mm) 100 Steam space volume (l) 348 Number of doors (ea.) 1 Inner glass door(s) (ea.) 1 Interior dimensions Width (mm) 650 A: Standard Climate range / B: Discontinuous range Heat compensation Height (mm) 785 Depth (mm) 485 Interior volume (l) 247 Racks (number standard/max.) 2 / 9 Load per rack (kg) 30 Permitted total load (kg) 100 Weight (empty) (kg) 184 Temperature data (without humidity) Temperature range ( C) 1) 0-70 Temperature variation at 25 C (± K) 0,2 Temperature variation at 40 C (± K) 0,3 Temperature fluctuation (± K) 0,1 Max. heat compensation up to 40 C (W) 300

Specifications KBF 240 (E5.2) Climate data (with humidity) Temperature range ( C) 1) 10-70 Temperature variation at 25 C / 60% RH (± K) 0,3 at 40 C / 75% RH (± K) 0,3 Temperature fluctuation at 25 C / 60% RH (± K) 0,1 at 40 C / 75% RH (± K) 0,1 Humidity range (% RH) 10-80 Humidity fluctuation at 25 C / 60% RH (± % RH) 1,5 at 40 C / 75% RH (± % RH) 1,5 Recovery time after door was opened for 30 sec at 25 C / 60% RH (min.) 4 at 40 C / 75% RH (min.) 5 Electrical data Voltage (± 10%) 50 / 60 Hz (V) 200-240 1N~ Nominal power (kw) 2,1 Energy consumption at 40 C / 75 % RH (kw) 1) 0,65 Noise level approx. (db (A)) 52 1) These values can be used for dimensioning air condition systems. All technical data are specified for units with standard equipment at an ambient temperature of 25 C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.

ptions BINDER DataLogger Kits The new BINDER Data Logger Kits Makes independent recording of temperature and humidity data in the BINDER device possible. The tailored product solution contains helpful accessories: from mounting the logger to the BINDER device to cable access assistance to the sensor mount. BINDER Pure Aqua Service This convenient and flexible water treatment system extends maintenance intervals and is easily implemented independent of water quality. The specific advantage: Point-of-use system with water quality display and replaceable filter cartridge. External water supply set External water supply set from fresh and waste water container, wiring and pump Temperature measurement of the specimen Additional PT 100 temperature sensor for accurate temperature measurement of the specimen and digital display of measured values. Recording of measured data via Ethernet or RS 422 interface optional.

ptions KBF 240 (E5.2) Access ports with silicone plug, 30, 50, 100 mm Fasteners for additional security for racks (1 set of 4) Lockable controller keyboard Additional PT 100 temperature sensor, flexibly installed with external connection, includes LEM connector (3-pin) RS 422 interface for communication software APT-CM DataControlSystem External water supply set including fresh and waste water containers, cabling, and pump BINDER PURE AQUA SERVICE containing single-use cartridge, cabling and measuring device Calibration certificate for temperature and humidity. Measurement in center of chamber at 25 C / 60% RH or at specified values Extension to calibration certificate for temperature and humidity. Each additional measurement at an additional measuring point or set of values Temperature precision measurement according to DIN 12880 and 9-point humidity measurement / factory standard with measurement log and certificate, measured at 25 C / 60% RH or at specified values Data Logger Kit TH 70: For continuous temperature and humidity recording of -40 C to 70 C / 0% to 100% RH. Kit includes 1 data logger, 1 attachable combined humidity/temperature sensor, 2 m extension cable and 1 fixture for mounting to the BINDER unit Data Logger Kit TH 70/70: With two attachable combined sensors. ne for the continuous temperature and humidity recording of -40 C to 70 C / 0% to 100 % RH. Second one at the data logger for recording the environmental conditions. Kit includes 1 data logger, 2 attachable combined humidity/temperature sensors, 2 m extension cable and 1 fixture for mounting to the BINDER unit Data Logger Kit T 220: For continuous temperature recording of -90 C to 220 C. Kit includes 1 data logger, PT 100 sensor with 2 m Teflon extension cable and 1 fixture for mounting to the BINDER unit Data Logger Software: Configuration and evaluation software for all BINDER Data Logger Kits, incl. data cable Rack, stainless steel Reinforced rack, stainless steel, with 1 set of fasteners (4 pieces), max. load 70 kg Perforated shelf, stainless steel Independent temperature safety device class 3.3 (DIN 12880) with optical alarm 4-20 ma analog outputs for temperature and humidity measurements (e.g. chart recorder connection) with 6-pin DIN socket. utputs are adjusted automatically when adjusting the controller. Zero-voltage relay alarm outputs for temperature (±2 C) and humidity (±5% RH), accessible via 6-pin DIN socket, with audible signal that can be switched off (maximum power rating 24 V AC/DC, 2.5 A) Switchable waterproof interior socket 230 V AC (max. 500 W), protection class IP 65, with corresponding plug. Max. permissible operating temperature 50 C Door lock Interior lighting (15 W) Connect With Us