Plant growth chambers

Similar documents
KMF Environmental test chamber for constant climate

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Constant climate chambers

Constant climate chambers

Constant climate chambers

Constant climate chambers

Constant climate chambers

Constant climate chamber with ICH-compliant illumination

New Generation KBF 240 series

Constant climate chamber with humidity

Constant climate chambers

Environmental simulation chamber for complex alternating climate profiles

Constant climate chambers

Model KBWF 720 Growth chambers with light and humidity

Model KBWF 240 Growth chambers with light and humidity

Model KBF 240 Constant climate chambers with large temperature / humidity range

VD 53 - Vacuum drying oven for non-flammable solvents

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Safety vacuum drying oven for flammable solvents

Vacuum drying oven for non-flammable solvents

Constant climate chambers. Always the right climate KBF KBF P KBF LQC KMF series

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

BINDER Industrial. Product Catalog

Product Highlights. BINDER Scientific with New Avantgarde.Line Products

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

Vacuum drying VD VDL series

Constant climate chambers

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

ULTRA.GUARD ultra low temperature freezer

BINDER Scientific Product Catalog

Standard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

BINDER Product catalog

FITOCLIMA 600 & 1200 STABILITY

FITOCLIMA 600 & 1200 STABILITY

FITOCLIMA 600 & 1200 PHARMA

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Environmental Chambers

Model C 170 CO 2 incubators with hot air sterilization

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

Drying and heating chambers

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

HettCube INCUBATORS SUSTAINABLE. ERGONOMIC. HIGH QUALITY. INCUBATOR. Find out more by visiting:

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

STABILITY ICH. ICH Stability Tests

Fitoclima Pharma. Stability and Photostability Chambers for the pharmaceutical industry

Reproducible Climate...

www

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTING

Vacuum drying chambers. VD VDL series

Protect your research

CO₂ incubators. C CB series

FITOCLIMA ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Thermo Scientific Heraeus microbiological incubators An optimal environment for your samples

6 POINTS TO CONSIDER WHEN PURCHASING A CONSTANT CLIMATE CHAMBER IN THE PHARMACEUTICAL INDUSTRY BUYER S GUIDE

Platelet bags constant shaking for long periods of time.

ICH750L. Climate Chamber. Product specification

Chromatographic Air circulated Refrigerator, two-door TC 603

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Environmental Chambers

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

NEW GENERATION. Efficient use of valuable space INCUBATORS

Drying and heating chambers. Series ED FD FED FP M

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY REACH-IN CHAMBERS FOR ENVIRONMENTAL TESTING

CO₂ incubators. C CB series

Photo Stability Chamber

FitoClima / FitoTerm SOL chambers

Chromatographic Air circulated Refrigerator, two-door TC 603

SNIJDERS LABS EXPERIENCED INNOVATORS. MICRO CLIMA SERIES ARABIDOPSIS CHAMBER, type MCA1600. MCA1600 Pagina 1 van 11 STEK ISO9001:2008 CERTIFIED

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

MICRO CLIMA-SERIES TM PREMIUM ICH INSECT CHAMBER

Key benefits. Why Condair CP3?

Digital incubating/ refrigerating benchtop shakers

Refrigerated Incubators / Environmental Testing Chambers

FITOCLIMA 600 & 1200 BIO

Technical Description. Climate Test Cabinet with increased change rates. Stress Screening System Weiss. Mat. No.: Type

ICH110. Climate Chamber. Product specification

ICH260C. Climate Chamber. Product specification

Stability Testing according to GMP & FDA

Humidity Chambers HCP

MINI BENCH TOP CHAMBER MODEL: MI-80-A-H

Laboratory Refrigerator/Deep Freezer TC 802

OVENS. All our ovens are tested to meet electrical safety standard IEC EN , this standard provides additional security for laboratories.

CLIMATRON GROWTH CABINETS

Long Term Storage Cabinet


External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

ENVIRONMENT FRIENDLY CLIMATIC CHAMBER

ISF4-X (Climo-Shaker)

Rieger. Industrievertretungen GmbH. Vertrieb durch: Ihr Anbieter für Geräte im Bereich Labor, Mikrobiologie und Industrie. Wir sind für Sie da:

MSD Cabinets. Modular Dry Cabinet. Outstanding performance

shaker LT-X (Lab-Therm) Space saving stackable incubator shaker

Medical Refrigerators

Dräger Polytron 7000 Fixed gas detector

FitoClima 600 PDH. Climatic Chamber specially developed for reaching low humidity levels DC013EN/03

Transcription:

Plant growth chambers KBWF 240 (E5.1) - Plant growth chamber with optimal climatic conditions The closest thing to natural conditions. Making use of the multifaceted programming options, we achieve perfect interaction between heat or cold, humidity and light. This wide climatic range can simulate any climatic condition precisely and constant over extended periods of time, including natural lighting conditions and day-night simulation. Performance features and equipment : Electronically controlled APT.line preheating chamber assuring temperature accuracy and reproducible results Temperature range 0 C to 70 C (32 F to 158 F) (without illumination), 10 C to 60 C (50 F to 140 F) (with illumination) Humidity range: without illumination cassette: 10 % - 80 % RF Humidity range: with illumination cassette: 10 % - 75 % RF MCS controller with 25 storable programs of 100 sections each for a maximum of 500 program segments Features: User friendly LCD screen Easy-to-read menu guide Integrated electronic chart recorder Variety of options for the graphic display of process parameters Real-time clock 2 variable positionable illumination cassettes with 5 daylight fluorescent illumination tubes Controlled humidification and dehumidification system with capacitive humidity sensor Independent adjustable temperature safety device class 3.1, providing full protection against chamber over-temperature, with visual and audible temperature alarm Access port Ø 30 mm (1.18 inch), left side Environmental friendly refrigerant R 134a Inner glass door Complete safety connection kit for water supply and drainage, including water hose, total length 6 m (19.7 ft.) RS 422 interface for use with optional GMP/GLP and FDA guideline 21 CFR Part 11 compliant APT-CM DataControlSystem software 2 stainless steel racks included BINDER test certificate 07/21/2009

Technical specification KBWF 240 (E5.1) Temperature-humidity chart with light KBWF 240 (E5.1) Exterior dimensions Width (mm/inch) 925 / 36.4 Height (incl. castors) (mm/inch) 1460 / 57.5 Depth (mm/inch) 800 / 31.5 Plus door handle, I-triangle, connection (mm/inch) 100 / 3.9 Wall clearance rear (mm/inch) 100 / 3.9 Wall clearance side (mm/inch) 100 / 3.9 Steam space volume (l/cu.ft.) 348 / 12.3 Number of doors 1 Number of inner glass doors 1 Interior dimensions Width (mm/inch) 650 / 25.6 Height (mm/inch) 785 / 30.9 Depth (mm/inch) 485 / 19.1 Interior volume (l/cu.ft.) 247 / 8.7 Racks (number standard / max.) 2 / 7 Load per rack (kg/lbs.) 30 / 66 Permitted total load (kg/lbs.) 100 / 221 Weight (empty) (kg/lbs.) 214 / 472 A: Standard Climate range / B: Discontinuous range Temperature-humidity chart without light Temperature data (without humidity) Temperature range without light cassettes 1) ( C/ F) 0-70 / 32-158 Temperature range with light cassettes and illumination 1) ( C/ F) Max. heat compensation up to 40 C (104 F) with illumination (W) 10-60 / 50-140 400 Climatic data (with humidity) Temperature range without light cassettes 1) ( C/ F) 10-70 / 32-158 Temperature range with light cassettes and illumination 1) ( C/ F) Temperature variation with illumination (± K) 0.5-1.0 Temperature fluctuation with illumination (± K) 0.1-0.5 Humidity range without light cassettes (% RH) 10-80 Humidity range with light cassettes and illumination 1) (% RH) Humidity fluctuation with illumination (± % RH) 2 10-60 / 50-140 10-75 A: Standard Climate range / B: Discontinuous range Illumination data per light cassette Daylight tubes 2) (Lux) 10000 Daylight tubes 2) (W/m²) 36 Fluora growth lamps 2) (Lux) 6500 Fluora growth lamps 2) (W/m²) 34 Arabidopsis lamps 2) (Lux) 10000 Arabidopsis lamps 2) (W/m²) 40 Electrical data Housing protection acc. to EN 60529 IP 20 Nominal voltage (±10 %) 50 / 60 Hz (V) 200-240 1N~ Nominal power at 240 V (kw) 2.4 Energy consumption at 37 C (98.6 F) / 75 % RH 3) (W) Noise level approx. (db (A)) 52 600 1. Tap water [municipal] with a max. hardness of 8.0 dh = 1.4285 mmol/l. (The hardness can be established from the water analysis of your water supplier.) 2. We recommend the BINDER Pure Aqua Service for longer maintenance intervals, regardless of water quality. 3. Demineralized or deionized water available at the customers location.

Technical specification KBWF 240 (E5.1) 1) Lower values are valid up to an ambient temperature of max. 25 C (77 F) 2) Average value, measured with a spherical sensor (±10 %) by 12 cm (4.7 inch) below the light cassette. The values given in W/m² refer to global radiation. 3) Use this value for dimensioning air condition systems All technical data are specified for units with standard equipment at an ambient temperature of 25 C and a voltage fluctuation of ±10 %. The temperature data are determinated in ccordance to factory standard following DIN 12880 respecting the recommended wall clearances of 10 % of the height, width and depth of the inner chamber. Technical data refers to 100 % fan speed. All indications are average values, typical for units produced in series. We reserve the right to alter technical specifications at all times.

ptions and accessories KBWF series Access ports With silicon plugs for inserting external measuring devices into the chamber. Access ports with 10, 50 and 100 mm diameter. BINDER Pure Aqua Service ur efficient, flexible water purification system delivers top water quality and extends the maintenance period. Special feature: ur system uses a disposable purification cartridge and also has a water quality indicator. External fresh water supply set External fresh water supply set consits of fresh and waste water canister, cabling and pump. Specimen temperature measurement Additional flexible PT 100 temperature sensor for precise temperature measurement of the specimen with digital temperature display. Recording of measured data possible via Ethernet or RS 422 interface.

ptions and accessories KBWF series Access port with silicone plugs, 30 mm (1.18 inch), 50 mm (1.97 inch), 100 mm (3.94 inch) Securing elements for additional fastening of racks (1 set of 4) Ethernet interface for communication software APT - CM DataControlSystem External fresh supply set consits of fresh and waste water canister, cabling and pump BINDER PURE AQUA SERVICE consisting of disposible cartridge, hose set and measuring unit Temperature precision measurement according to DIN 12880 and 9 - point humidity measurement / factory standard with measurement log and certificate, measured at 25 C (77 F) / 60% RH or at specified values Factory calibration certificate for temperature and humidity. Measurement in center of chamber at 25 C (77 F) / 60% RH or at specified values Extension to factory calibration certificate for temperature and humidity. Each additional measurement at an additional measuring point or set of values Rack, stainless steel Shelf, perforated, stainless steel Reinforced rack, stainless steel, with 1 set of securing elements (4 pieces) (max. load 70 kg / 154 lbs.) Vibration compatible shelf / platform to be mounted inside the chamber for shaker / spinner / roller operation (> 500 rpm to be supported) 4-20 ma analog output for temperature and humidity measurements (e.g. chart recorder connection), with 6 - pin DIN socket. utputs are adjusted automatically as the controller is adjusted Zero-voltage relay alarm outputs for temperature (±2 C) and humidity (±5 % RH), accessible via 6-pin DIN socket, with acoustic signal that can be switched off (maximum power rating 24 V AC/DC, 2.5 A) Switchable waterproof interior socket 230 V AC (max. 500 W), IP 65 protected, with corresponding plug (IP 66 protected) FLURA growth lamps set as replacement for the standard tubes Arabidopsis fluorescent tubes set as replacement for the standard tubes Lockable door Temperature safety device, Class 3.3 (DIN 12880) with optical alarm KBWF 240 (E5.1)

Thank you for reading this data sheet. For pricing or for further information, please contact us at our UK ffice, using the details below. UK ffice Keison Products, P.. Box 2124, Chelmsford, Essex, CM1 3UP, England. Tel: +44 (0)330 088 0560 Fax: +44 (0)1245 808399 Email: sales@keison.co.uk Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.