Constant climate chambers

Similar documents
Constant climate chambers

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Constant climate chambers

Constant climate chambers

Constant climate chambers

KMF Environmental test chamber for constant climate

Constant climate chambers

Plant growth chambers

Constant climate chamber with humidity

Constant climate chambers

Constant climate chamber with ICH-compliant illumination

New Generation KBF 240 series

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Environmental simulation chamber for complex alternating climate profiles

VD 53 - Vacuum drying oven for non-flammable solvents

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Model KBF 240 Constant climate chambers with large temperature / humidity range

Safety vacuum drying oven for flammable solvents

Vacuum drying oven for non-flammable solvents

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Model KBWF 240 Growth chambers with light and humidity

Model KBWF 720 Growth chambers with light and humidity

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

Vacuum drying VD VDL series

Model C 170 CO 2 incubators with hot air sterilization

BINDER Industrial. Product Catalog

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

BINDER Scientific Product Catalog

Product Highlights. BINDER Scientific with New Avantgarde.Line Products

Constant climate chambers. Always the right climate KBF KBF P KBF LQC KMF series

ULTRA.GUARD ultra low temperature freezer

Constant climate chambers

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Standard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series

Protect your research

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

BINDER Product catalog

Drying and heating chambers

Environmental Chambers

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

ICH110. Climate Chamber. Product specification

ICH260C. Climate Chamber. Product specification

CO₂ incubators. C CB series

ICH750L. Climate Chamber. Product specification

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

ENVAIR lab CO2 Tri-Gas Incubator

STABILITY ICH. ICH Stability Tests

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

VWR symphony CO 2 INCUBATORS

Walk in Steam Curing Chamber for Concrete Application. Detailed Working Specifications

FITOCLIMA 600 & 1200 STABILITY

Thermo Scientific Heraeus microbiological incubators An optimal environment for your samples

Vacuum drying chambers. VD VDL series

StableClimate Stability Chambers

Introductions. Safe for cultivation

Fitoclima Pharma. Stability and Photostability Chambers for the pharmaceutical industry

OVENS. All our ovens are tested to meet electrical safety standard IEC EN , this standard provides additional security for laboratories.

FITOCLIMA 600 & 1200 STABILITY

FITOCLIMA 600 & 1200 PHARMA

Environmental Chambers. 2-Door & 3-Door Extra Large Capacity

HettCube INCUBATORS SUSTAINABLE. ERGONOMIC. HIGH QUALITY. INCUBATOR. Find out more by visiting:

CO 2 Incubators INCO 2

Environmental Chambers

Absolutely precise control of temperature, humidity, CO 2 and O 2 content from the experts for controlled atmosphere

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

CO₂ incubators. C CB series

creating the right atmosphere NEW SERIES Galaxy Plus 170 litre CO 2 Incubators Advanced design for optimum results

incubator, the best in its class

EC 160 CO 2. Incubator

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

Platinous. temperature. and humidity. chambers. Top Quality Design. With an Easy-to-use. Touch-Screen. Programmer

FROILABO offers a full range of incubators with natural convection, air forced or forced cooling to cover most laboratory applications.

Refrigerated Incubators / Environmental Testing Chambers

Constant climate chambers HPP Humidity chambers HCP

Stability Testing according to GMP & FDA

Photo Stability Chamber

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTING

Environmental Chambers Series: reach-in & benchtop capacities

Laboratory Refrigerator/Deep Freezer TC 802

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

ENVAIR lab CO2 Incubator

6 POINTS TO CONSIDER WHEN PURCHASING A CONSTANT CLIMATE CHAMBER IN THE PHARMACEUTICAL INDUSTRY BUYER S GUIDE

SDR Dry Room. Outstanding performance

Termaks AS Lien 79, N-5057 Bergen, Norway Tel: Fax: Web:

Thermo Scientific Heraeus Heating and Drying Ovens

Drying and heating chambers. Series ED FD FED FP M

Long Term Storage Cabinet

Thermo Scientific Heratherm Microbiological Incubators

D3000. Installation & Setup Guide

Sunrise the beginning of a brand new day

Humidity Chambers HCP

MICRO CLIMA-SERIES TM PREMIUM ICH INSECT CHAMBER

ENVIRONMENT FRIENDLY CLIMATIC CHAMBER

AQUACON. Chief characteristic for realizing this product family was:

Thermo Scientific Heratherm Microbiological Incubators. safe easy efficient

Chromatographic Air circulated Refrigerator, two-door TC 603

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

FUNCTION LINE HEATING AND DRYING OVENS

Transcription:

Constant climate chambers KBF 115 (E2) - Constant climate chamber The KBF series was particularly designed for absolutely reliable stability tests and precise maintenance of constant climatic conditions. With its large reserve capacity and many optional features, it is designed to meet future challenges for many years to come. Performance features and equipment : Electronically controlled APT.line preheating chamber and refrigerating system assuring temperature accuracy and reproducible results Temperature range -10 C (14 F) up to 100 C (212 F) - without humitiy Humidity range 10 % RH to 90 % RH MCS controller with 25 storable programs of 100 sections each for a maximum of 500 program segments Features: User friendly LCD screen Easy-to-read menu guide Integrated electronic chart recorder Real time clock Electronically controlled controlled humidification and dehumidification system with capacitive humidity sensor Suitable for stability tests according to ICH guideline Q1A Inner glass door Environmental friendly refrigerant R 134a Independent adjustable temperature safety device class 3.1 (DIN 12880), with visual and audible temperature alarm Access port with silicone plug Ø 30 mm (1.18 inch), left side Complete safety connection kit for water supply and drainage, including water hose, total length 6 m (19.7 ft.) RS 422 interface for use with optional GMP/GLP and FDA guideline 21 CFR Part 11 compliant APT-CM DataControlSystem software 2 stainless steel racks included BINDER test certificate

Technical specification KBF 115 (E2) Temperature-humidity chart Exterior dimensions Width (mm/inch) 834 / 32.8 Height (inclusive feet/castors) (mm/inch) KBF 115 (E2) 1022 / 40.2 Depth (mm/inch) 646 / 25.4 Plus door handle, I - panel, connection (mm/inch) Wall clearance rear (mm/inch) Wall clearance side (mm/inch) Steam space volume (l/cu.ft.) Height of water connections (± 3 mm / 0.12 inch) Number of doors 1 Number of inner glass doors 1 Interior dimensions 100 / 3.9 100 / 3.9 160 / 6.3 158 / 5.6 84 / 3.3 Width (mm/inch) 600 / 23.6 Height (mm/inch) 480 / 18.9 Depth (mm/inch) 400 / 15.8 Interior volume (l/cu.ft.) 115 / 4.1 Racks (number standard/max.) 2 / 5 Load per rack (kg/lbs.) 20 / 44 Permitted total load (kg/lbs.) 50 / 110 Weight of the unit (empty) (kg/lbs.) 115 / 254 The light area indicates the control range of temperature and relative humidity. The hatched area indicates the control range of temperature and relative humidity without condensation. Temperature data Temperature range without humidity C / F -10-100 / 14-212 with humidity (approx. C / F) Temperature variation without humidity at 10 C (± C) 0.4 at 37 C (± C) 0.3 Temperature variation with humidity 2) (± C) Temperature fluctuation from 5 C above ambient temp. 2) (± C) Temperature fluctuation when refrigerating (± C) Heating up time 1) 2) to 37 C (min.) Cooling down time from room temp.1) 2) to 10 C (min.) Recovery time after doors were open for 30 sec 1) 2) at 37 C (minutes) 5 at 50 C (minutes) 4 Humidity fluctuation 2) 4) (± RH %) 10-90 / 50-194 1 0.1 0.5 23 35 1.5 Electrical data Housing protection acc. to EN 60529 Nominal voltage (±10 %) 50 / 60 Hz (V) IP 20 230 Nominal power (W) 1300 Energy consumption 4) at 37 C (89.6 F) (KBF 240 at 40 C (104 F)) (W) 530

Technical specification KBF 115 (E2) 1) up to 98 % of the set value 2) value without lighting 3) Upon door opening or water exchange in humidity cylinder: > ± 1.5 RH %, recovery time approx. 20 min 4) These energy consumption values can be used upon calculation of air conditioning systems. 5) Maximal value, measured in center of usable volume By bringing in in a humidity source to the inner chamber the minimal humidity range is affected. A water tap (1 6 bar) with normal tap water (approx. 200 500 µs/tolerance +300 150 µs, total hardness appr.4-8 dh) is necessary for the installation of the humidifying and dehumidifying system. Furthermore, a 40 mm water drain with descending gradient is required. All technical data are specified for units with standard equipment at an ambient temperature of 20 C and a voltage fluctuation of ±10 %. The temperature data are determinated in accordance to factory standard following DIN 12880 respecting the recommended wall clearances of 10 % of the height, width and depth of the inner chamber.all indications are average values, typical for units produced in series. We reserve the right to alter technical specifications at all times.

ptions and accessories KBF series Access ports With silicon plugs for inserting external measuring devices into the chamber. Access ports with 10, 30, 50, and 100 mm diameter. APT-CM DataControlSystem GLP Edition Software for GLP compliant control, programming, and documentation. Permits networks of up to 30 units and/or controllers. Meets the requirements of FDA 21 CFR Part 11. Calibration certificates and validation BINDER can significantly reduce the time and effort needed for equipment qualification and validation. We draw on unparalleled knowledge of our equipment applications and years of experience in certification.

ptions and accessories KBF series Access port with silicone plugs, 10 mm (0.39 inch), 30 mm (1.18 inch), 50 mm (1.97 inch), 100 mm (3.94 inch) Securing elements for additional fastening of racks (1 set of 4) Safety device, Class 3.3 (DIN 12880) with optical alarm Locking of controller keyboard Cleaning kit for equipment maintenance and disinfection, consisting of ph - neutral detergent (1000 g / 2.21 lbs., concentrate), spray disinfectant (500 ml / 0.13 gal. ready - for - use solution) and lint - free cleansing tissues Temperature precision measurement according to DIN 12880 and 9 - point humidity measurement / factory standard with measurement log and certificate, measured at 25 C (77 F) / 60% RH or at specified values Factory calibration certificate for temperature and humidity. Measurement in center of chamber at 25 C (77 F) / 60% RH or at specified values Extension to factory calibration certificate for temperature and humidity. Each additional measurement at an additional measuring point or set of values Built-in 2-channel chart recorder, with digital display and programmable text output (date, time) for the documentation of temperature and humidity values Switchable waterproof interior socket 230 V AC (max. 500 W), IP 65 protected, with corresponding plug (IP 66 protected) 4-20 ma analog output for temperature and humidity measurements (e.g. chart recorder connection), with 6 - pin DIN socket. utputs are adjusted automatically as the controller is adjusted Zero - voltage relay alarm outputs for temperature (±2 C) and humidity (±5 % RH), accessible via 6 - pin DIN socket, with acoustic signal that can be switched off (maximum power rating 24 V AC / DC, 2.5 A) Rack, stainless steel Shelf, perforated, stainless steel Lockable door KBF 115 (E2)