KMF Environmental test chamber for constant climate

Similar documents
Plant growth chambers

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Constant climate chambers

Constant climate chambers

Constant climate chambers

Constant climate chambers

Constant climate chambers

Constant climate chambers

Constant climate chamber with humidity

New Generation KBF 240 series

Environmental simulation chamber for complex alternating climate profiles

Constant climate chamber with ICH-compliant illumination

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Constant climate chambers

VD 53 - Vacuum drying oven for non-flammable solvents

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

Model KBF 240 Constant climate chambers with large temperature / humidity range

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Safety vacuum drying oven for flammable solvents

BINDER Industrial. Product Catalog

Vacuum drying oven for non-flammable solvents

Model KBWF 720 Growth chambers with light and humidity

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Model KBWF 240 Growth chambers with light and humidity

Constant climate chambers. Always the right climate KBF KBF P KBF LQC KMF series

Vacuum drying VD VDL series

BINDER Scientific Product Catalog

ULTRA.GUARD ultra low temperature freezer

Constant climate chambers

Product Highlights. BINDER Scientific with New Avantgarde.Line Products

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Drying and heating chambers

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Standard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series

Model C 170 CO 2 incubators with hot air sterilization

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Environmental Chambers

Reproducible Climate...

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

BINDER Product catalog

Drying and heating chambers. Series ED FD FED FP M

CO₂ incubators. C CB series

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTING

FITOCLIMA 600 & 1200 STABILITY

HettCube INCUBATORS SUSTAINABLE. ERGONOMIC. HIGH QUALITY. INCUBATOR. Find out more by visiting:

FITOCLIMA 600 & 1200 STABILITY

Protect your research

Vacuum drying chambers. VD VDL series

FITOCLIMA 600 & 1200 PHARMA

Technical Description. Climate Test Cabinet with increased change rates. Stress Screening System Weiss. Mat. No.: Type

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

Fitoclima Pharma. Stability and Photostability Chambers for the pharmaceutical industry

STABILITY ICH. ICH Stability Tests

Long Term Storage Cabinet

MINI BENCH TOP CHAMBER MODEL: MI-80-A-H

Thermo Scientific Heraeus microbiological incubators An optimal environment for your samples

FITOCLIMA ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

FitoClima / FitoTerm SOL chambers

OVENS. All our ovens are tested to meet electrical safety standard IEC EN , this standard provides additional security for laboratories.

MSD Cabinets. Modular Dry Cabinet. Outstanding performance

CO₂ incubators. C CB series

Photo Stability Chamber

XSD Dry Cabinet. Outstanding performance. The XSD series has an outstanding performance for drying moisture sensitive components and pcb s.

6 POINTS TO CONSIDER WHEN PURCHASING A CONSTANT CLIMATE CHAMBER IN THE PHARMACEUTICAL INDUSTRY BUYER S GUIDE

Key benefits. Why Condair CP3?

NEW GENERATION. Efficient use of valuable space INCUBATORS

SHAKING WATER BATHS ENGLISH

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Environmental Chambers Series: reach-in & benchtop capacities

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

Compact Ultra Low Temperature Chamber

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY REACH-IN CHAMBERS FOR ENVIRONMENTAL TESTING

Environmental Chambers

Stability Testing according to GMP & FDA

HSD Dry Cabinet. Outstanding performance

FitoClima 600 PDH. Climatic Chamber specially developed for reaching low humidity levels DC013EN/03

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Sunrise the beginning of a brand new day

Thermo Scientific Heraeus Heating and Drying Ovens

Chromatographic Air circulated Refrigerator, two-door TC 603

Product data sheet AIRWIN additional modules Accessories AIRWIN

ENVAIR lab CO2 Tri-Gas Incubator

ZL Laboratory freezers

Environmental Chambers. 2-Door & 3-Door Extra Large Capacity

Laboratory thermostatic chambers

SDR Dry Room. Outstanding performance

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

ECL Comfort 300 / V a.c. and 24 V a.c.

HSD Dry Cabinet. Outstanding performance

HSD Dry Cabinet

Absolutely precise control of temperature, humidity, CO 2 and O 2 content from the experts for controlled atmosphere

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Transcription:

SHENZHEN YIHUAXIN ELECTRNICS C.,LTD Tel:+86-755-86218000 Fax:+86-755-86218111 www.yihuaxin.net yhx@yihuaxin.net Environmental test chambers KMF 240 - Environmental test chamber for constant climate The KMF is designed for absolutely reliable stability tests and precise maintenance of constant climatic conditions. Its advanced reserve capacity and extremely broad climatic range are designed to meet any future requirements. Performance features and equipment: Electronically controlled APT.line preheating chamber and refrigerating system assuring temperature accuracy and reproducible results Temperature range -10 C - 100 C (14 F - 212 F) Temperature range with humidity 10-90 C (50 F - 194 F) Humidity range 10 % RH to 90 % RH MCS controller with 25 storable programs of 100 sections each for a maximum of 500 program segments Features: User friendly LCD screen Easy-to-read menu guide Integrated electronic chart recorder Variety of options for the graphic display of process parameters Real time clock Electronically controlled humidification and dehumidification system with capacitive humidity sensor Heated door, inner glass door with sealing Environmental friendly refrigerant R 134a Independent adjustable temperature safety device class 3.1, providing full protection against chamber over-temperature, with visual and audible temperature alarm Access port with silicone plug Ø 30 mm (1.18 inch), left side Complete safety connection kit for water supply and drainage, including water hose, total length 6 m (19.7 ft.) Ethernet interface for use with optional GMP/GLP and FDA guideline 21 CFR Part 11 compliant APT-CM DataControlSystem software 1 stainless steel rack included BINDER test certificate

Technical specification KMF 240 Temperature-humidity chart Exterior dimensions Width (mm/inch) 925 / 36.4 Height (incl. feet/castors) (mm/inch) KMF 240 1460 / 57.5 Depth (mm/inch) 800 / 31.5 plus door handle, I-triangle, connection (mm/inch) Wall clearance rear (minimum) (spacer) (mm/inch) Wall clearance side (minimum) (mm/inch) 850 / 33.5 100 / 3.94 100 / 3.94 Steam space volume (l/cu.ft.) 348 / 12.3 Number of doors 1 Number of inner glass doors 1 Interior dimensions Width (mm/inch) 650 / 25.6 Height (mm/inch) 785 / 30.9 Depth (mm/inch) 485 / 19.1 Interior volume (l/cu.ft.) 247 / 8.6 Racks (standard/max.) 1 / 9 Load per rack (kg/lbs.) 30 / 66 Permitted total load (kg/lbs.) 100 / 221 Weight (empty) (kg/lbs.) 185 / 408 A: Standard Climate range / B: Discontinuous range / C: In this range, condensation in the inner chamber is possible Heat compensation Temperature data (without humidity) Temperature range 1) ( C/ F) -10-100 (14-212) Average heating up time acc. to IEC 60068-3-5 (K/min.) Average cooling down time acc. to IEC 60068-3-5 (K/min.) Heating up time from -10 C to 100 C (14 F - 212 F) 2) (min.) Cooling down time from 100 C to -10 C (212 F - 14 F) 2) (min.) 1.1 0.6 100 285 Climatic data (with humidity) Temperature range 1) ( C/ F) 10-90 (14-212) Temperature variation (spatial) 3) (± K) Temperature fluctuation 3) (± K) 0.3-1.5 0.1-0.5 Humidity range (% RH) 10-90 Humidity fluctuation 3) (±% RH) Max. heat compensation at 25 C / 77 F / 90% RH (W) Dew point temperature range ( C) 2 100 5-80 Electrical data Housing protection acc. to EN 60529 Nominal voltage (±10 %) 50 / 60 Hz (V) IP 20 Nominal power at 240 V (kw) 2.1 Energy consumption 4) at 85 C (104 F) (W) 200-240 500 Noise level (db (A)) 52 1. Tap water [municipal] with a max. hardness of 8.0 dh = 1.4285 mmol/l. (The hardness can be established from the water analysis of your water supplier.) SHENZHEN YIHUAXIN ELECTRNICS C.,LTD Tel:+86-755-86218000 Fax:+86-755-86218111 www.yihuaxin.net yhx@yihuaxin.net

Technical specification KMF 240 2. We recommend the BINDER Pure Aqua Service for longer maintenance intervals, regardless of water quality. 3. Demineralized or deionized water available at the customers location. 1) Lower values are valid up to an ambient temperature of max. 25 C (77 F) 2) up to 98 % of the set value 3) depending on the set-point 4) Use this value for dimensioning air condition systems All technical data are specified for units with standard equipment at an ambient temperature of 25 C and a voltage fluctuation of ±10 %. The temperature data are determinated in ccordance to factory standard following DIN 12880 respecting the recommended wall clearances of 10 % of the height,width and depth of the inner chamber. Technical data refers to 100 % fan speed. All indications are average values, typical for units produced in series. We reserve the right to alter technical specifications at all times. SHENZHEN YIHUAXIN ELECTRNICS C.,LTD Tel:+86-755-86218000 Fax:+86-755-86218111 www.yihuaxin.net yhx@yihuaxin.net

ptions and accessories KMF series Access ports With silicon plugs for inserting external measuring devices into the chamber. Access ports with 10, 50, and 100 mm diameter. BINDER Pure Aqua Service ur efficient, flexible water purification system delivers top water quality and extends the maintenance period. Special feature: ur system uses a disposable purification cartridge and also has a water quality indicator. External fresh water supply set External fresh water supply set consits of fresh and waste water canister, cabling and pump. Specimen temperature measurement Additional flexible PT 100 temperature sensor for precise temperature measurement of the specimen with digital temperature display. Recording of measured data possible via Ethernet or RS 422 interface. SHENZHEN YIHUAXIN ELECTRNICS C.,LTD Tel:+86-755-86218000 Fax:+86-755-86218111 www.yihuaxin.net yhx@yihuaxin.net

ptions and accessories KMF series Access port with silicone plugs, 30 mm (1.18 inch), 50 mm (1.97 inch), 100 mm (3.94 inch) Securing elements for additional fastening of racks (1 set of 4). Rack, stainless steel Reinforced rack, stainless steel, with 1 set of securing elements (4 pieces) (max. load 70 kg / 154 lbs.). Shelf, perforated, stainless steel Lockable door Reinforced inner chamber, including 2 Reinforced racks, maximum total load 250 kg (552 lbs.), max. load per rack 70 kg (154 lbs.) Safety device, Class 3.3 (DIN 12880) with optical alarm 4-20 ma analog output for temperature and humidity measurements (e.g. chart recorder connection), with 6 - pin DIN socket. utputs are adjusted automatically as the controller is adjusted. Additional PT 100 temperature sensor, flexibly installed, with external connection, including LEM connector (3 - pin). RS 422 interface External fresh supply set consits of fresh and waste water canister, cabling and pump BINDER PURE AQUA SERVICE consisting of disposible cartridge, cabling and measuring device Temperature precision measurement according to DIN 12880 and 9-point humidity measurement / factory standard with measurement log and certificate, measured at 20 C (68 F) / 60% RH or at specified values. Factory calibration certificate for temperature and humidity. Measurement in center of chamber at 20 C (68 F) / 60% RH or at specified values. Extension to factory calibration certificate for temperature and humidity. Each additional measurement at an additional measuring point or set of values. KMF 240 SHENZHEN YIHUAXIN ELECTRNICS C.,LTD Tel:+86-755-86218000 Fax:+86-755-86218111 www.yihuaxin.net yhx@yihuaxin.net 9