New Generation KBF 240 series

Constant climate chambers

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Constant climate chambers

KMF Environmental test chamber for constant climate

Constant climate chambers

Plant growth chambers

Constant climate chamber with humidity

Constant climate chambers

Constant climate chambers

Constant climate chamber with ICH-compliant illumination

Constant climate chambers

Environmental simulation chamber for complex alternating climate profiles

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

BINDER Industrial. Product Catalog

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Model KBF 240 Constant climate chambers with large temperature / humidity range

Constant climate chambers. Always the right climate KBF KBF P KBF LQC KMF series

BINDER Scientific Product Catalog

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

VD 53 - Vacuum drying oven for non-flammable solvents

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

Vacuum drying oven for non-flammable solvents

Constant climate chambers

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Model KBWF 240 Growth chambers with light and humidity

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Model KBWF 720 Growth chambers with light and humidity

Product Highlights. BINDER Scientific with New Avantgarde.Line Products

Vacuum drying VD VDL series

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Safety vacuum drying oven for flammable solvents

Standard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series

Drying and heating chambers

ULTRA.GUARD ultra low temperature freezer

BINDER Product catalog

CO₂ incubators. C CB series

Drying and heating chambers. Series ED FD FED FP M

Translation of the original operating manual

Environmental Chambers

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

Model C 170 CO 2 incubators with hot air sterilization

Vacuum drying chambers. VD VDL series

CO₂ incubators. C CB series

ICH750L. Climate Chamber. Product specification

6 POINTS TO CONSIDER WHEN PURCHASING A CONSTANT CLIMATE CHAMBER IN THE PHARMACEUTICAL INDUSTRY BUYER S GUIDE

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

Translation of the original operating manual. Constant climate chambers with program control

ICH110. Climate Chamber. Product specification

ICH260C. Climate Chamber. Product specification

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Fitoclima Pharma. Stability and Photostability Chambers for the pharmaceutical industry

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Environmental Chambers

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

STABILITY ICH. ICH Stability Tests

FITOCLIMA 600 & 1200 PHARMA

Chromatographic Air circulated Refrigerator, two-door TC 603

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Protect your research

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

FITOCLIMA 600 & 1200 STABILITY

Chromatographic Air circulated Refrigerator, two-door TC 603

FITOCLIMA 600 & 1200 STABILITY

ENVIRONMENT FRIENDLY CLIMATIC CHAMBER

Environmental Chambers. 2-Door & 3-Door Extra Large Capacity

Thermo Scientific Heraeus microbiological incubators An optimal environment for your samples

HettCube INCUBATORS SUSTAINABLE. ERGONOMIC. HIGH QUALITY. INCUBATOR. Find out more by visiting:

Laboratory thermostatic chambers

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTING

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

Laboratory Refrigerator/Deep Freezer TC 802

plus a wide temperature range

NEW GENERATION. Efficient use of valuable space INCUBATORS

Ultra low temperature freezers

Thermo Scientific Forma Environmental Chambers. Controlled Temperature Storage Solutions

Stability Testing according to GMP & FDA

Thermo Scientific Forma Environmental Chambers. Controlled Temperature Storage Solutions. Optimum uniformity. plus a wide temperature range

Environmental Chambers Series: reach-in & benchtop capacities

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

FitoClima 600 PDH. Climatic Chamber specially developed for reaching low humidity levels DC013EN/03

Walk in Steam Curing Chamber for Concrete Application. Detailed Working Specifications

FITOCLIMA ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER

Constant climate chambers HPP Humidity chambers HCP

Translation of the original operating manual. Alternating climate chambers with program control

ENVAIR lab CO2 Tri-Gas Incubator

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Stability Testing GMP- and FDA-Compliant Reliable Solutions for the Pharmaceutical Industry

ZL Laboratory freezers

Long Term Storage Cabinet

Reproducible Climate...

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY REACH-IN CHAMBERS FOR ENVIRONMENTAL TESTING

Digital incubating/ refrigerating benchtop shakers

MSD Cabinets. Modular Dry Cabinet. Outstanding performance

HSD Dry Cabinet. Outstanding performance

www

Humidity Controller Specification and Installation Instructions. Model HRO20

Termaks AS Lien 79, N-5057 Bergen, Norway Tel: Fax: Web:

Transcription:

Constant climate chambers KBF series Environmental simulation chambers for constant climatic conditions The KBF series was particularly designed for absolutely reliable stability tests and precise maintenance of constant climatic conditions. With its large reserve capacity and many optional features, it is designed to meet future challenges for many years to come. Leistungsmerkmale/Ausstattung: Electronically controlled APT.line preheating chamber technology Temperature range: -10 C to 100 C (14 F to 212 F) (without humidity) Humidity range: 10 % to 90 % RH MCS controller with 25 storable programs of 100 sections each for a maximum of 500 program segments User-friendly LCD screen Easy-to-read menu guide Integrated electronic chart recorder Variety of options for the graphic display of process parameters Real-time clock Electronically controlled humidification and dehumidification system with SPH sensor technology with capacitive humidity sensor Suitable for stability tests in accordance with the ICH guideline Q1A Automatic defrosting device for long-term operation (except KBF 240) Inner glass door (KBF 240: Heated door, inner glass door with sealing) Environmentally friendly refrigerant R 134a Collecting pan for condensate on the door (KBF 115 and 720) Independent adjustable temperature safety device, Class 3.1 (DIN 12880) with optical and acoustic alarm Access port with silicone plug, Ø 30 mm (1.2 inch), right side (KBF 240: left side) Complete safety connection kit for water supply incl. water hose and drain (total length 6 m / 19.7 ft) RS 422 (KBF 240: Ethernet) interface for communication software APT-COM DataControlSystem 2 stainless steel racks BINDER test certificate

Technische Daten KBF series KBF 115 KBF 240 KBF 720 Exterior dimensions Width (mm/inch) 834 / 32.8 905 / 35.6 1234 / 48.6 Height (inclusive feet/castors) (mm/inch) 1022 / 40.2 1458 / 57.4 1816 / 71.5 Depth (mm/inch) 646 / 25.4 765 / 30.1 867 / 34.1 Plus door handle, I-panel, connection (mm/inch) 100 / 3.9 52 / 2.0 100 / 3.9 Wall clearance rear (mm/inch) 100 / 3.9 100 / 3.9 100 / 3.9 Wall clearance side (mm/inch) 160 / 6.3 100 / 3.9 160 / 6.3 Steam space volume (l/cu.ft.) 158 / 5.6 338 / 11.9 855 / 30.2 Height of water connections (± 3 mm / 0.12 inch) 84 / 3.3 84 / 3.3 190 / 7.5 Number of doors 1 1 2 Number of inner glass doors 1 1 2 Interior dimensions Width (mm/inch) 600 / 23.6 650 / 25.6 1000 / 39.4 Height (mm/inch) 480 / 18.9 785 / 30.9 1168 / 46.0 Depth (mm/inch) 400 / 15.8 470 / 18.5 600 / 23.6 Interior volume (l/cu.ft.) 115 / 4.1 240 / 8.5 700 / 24.7 Racks (number standard/max.) 2 / 5 2 / 9 2 / 14 Load per rack (kg/lbs.) 20 / 44 30 / 66 45 / 99 Permitted total load (kg/lbs.) 50 / 110 100 / 221 120 / 265 Weight of the unit (empty) (kg/lbs.) 115 / 254 185 / 408 278 / 614 Temperature data Permissible ambient temperature range ( C/ F) 5) 18-32 / 64.4-89.6-18-32 / 64.6-89.6 KBF without humidity ( C/ F) -10-100/14-212 -10-100/14-212 -10-100/14-212 KBF with humidity ( C/ F) 10-90 / 50-194 10-90 / 50-194 10-90 / 50-194 Temperature variation without humidity at 10 C (50 F) (KBF 240 at 25 C (77 F)) (± C) 0,4 / - 0,2 0,4 / - at 37 C (98.6 F) (KBF 240 at 40 C (104 F)) (± C) 0,3 / - 0,3 0,4 / - Temperature variation with humidity 2) at 25 C (77 F) (± C) 1 1,5 1 Temperature fluctuation from 5 C (9 F) above ambient temperature 2) (± C) 0,1 0,1 0,1 Temperature fluctuation when refrigeration system is in operation (± C) 0,5 0,5 0,5 Heating up time 1), 2) at 37 C (98.6 F) (KBF 240 from 25 C (77 F) to 40 C (104 F)) (Min.) 23 15 28 Cooling down time from room temp. 1), 2) at 10 C (50 F) (KBF 240 from 40 C (104 F) to 5 C (41 F)) (Min.) 35 90 35 Recovery time after doors were open for 30 sec. 1), 2) at 37 C (98.6 F) (KBF 240 at 25 C (77 F) / 60% RH) (Min.) 5 10 5 at 50 C (122 F) (KBF 240 at 40 C (104 F) / 75% RH) (Min.) 4 18 4 Humidity fluctuation 2), 4) (± RH%) 1,5 2,0 1,5 Electrical data Housing protection acc. to EN 60529 IP 20 IP 20 IP 20 Nominal voltage (±10 %) 50/60 Hz (V) 230 200-240 230 Nominal power (W) 1300 2700 2800 Energy consumption 4) at 37 C (89.6 F) (KBF 240 at 40 C (104 F)) (W) 530 434 610

1) up to 98 % of the set value 2) value without illumin. 3) upon door opening or water exchange in humidity cylinder: > ± 1.5 r.h.%, recovery time approx. 20 min 4) these energy consumption values can be used upon calculation of air conditioning systems 5) Recommended ambient temperature 20 C You can operate your KBF 240 with water from three different sources: 1 Tap water [municipal] with a max. hardness of 8.0 dh = 1.4285 mmol/l (the hardness can be established from the water analysis of your water supplier) 2 We recommmend the BINDER Pure Aqua Service for longer maintenance intervals, regardless of water quality 3 Demineralized or deionized water available at the customer's location For KBF 115 and 720: Tap water with conductivity of approx. 200-500 μs/cm, total hardness 4-8 dh, content of chloride < 100 mg/l (the hardness can be established from the water analysis of your water supplier) By introducing in a humidity source to the inner chamber the minimal humidity range is affected. A water tap (1 10 bar/14.5 145 psi) with normal tap water (conductivity of 200 500 μs/cm tolerance + 300 150 μs/cm, total hardness 4º 8 ºdH, content of chloride < 100mg/l) is necessary for the installation of the humidifying and dehumidifying system. Furthermore, a 40 mm (1.6 inch) water drain with descending gradient is required. All technical data are specified for units with standard equipment at an ambient temperature of 20 ºC (68 ºF) and a voltage fluctuation of ± 10 %. The temperature data are determinated in accordance to factory standard following DIN 12880 respecting the recommended wall clearances of 10 % of the height, width and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to alter technical specifications at all times.

Options/accessories KBF series BINDER Pure Aqua Service Our efficient, flexible water purification system delivers top water quality and extends the maintenance period. Special feature: Our system uses a disposable purification cartridge and also has a water quality indicator. Access ports With silicon plugs for inserting external measuring devices into the chamber. Access ports with 10, 30, 50, and 100 mm diameter. APT-COM DataControlSystem GLP Edition Software for GLP compliant control, programming, and documentation. Permits networks of up to 30 units and/or controllers. Meets the requirements of FDA 21 CFR Part 11. Calibration certificates Measurement in the center at specified values. Additional measuring points or test values according to your specification. KBF 115 KBF 240 KBF 720 Access port with silicone plug Rack, stainless steel Rack, perforated, stainless steel Reinforced rack, stainless steel, with 1 set of rack securings (max. 70 kg / 154 lbs.) - O O Independent adjustable temperature safety device, Class 3.3 (DIN 12880) Analog output, 4-20 ma for temperature and humidity with 6-pin DIN socket (Outputs are adjusted automatically as the controller is adjusted) Potential free alarm outputs for temperature and humidity, accessible via 6-pin DIN socket, with acustic signal that can be switched off (maximum power 24 V AC/DC, 2.5 A) Interior lighting (W) 15 15 30 Lockable door Built-in 2-channel chart recorder, with digital display for the documentation of temperature and humidity Waterproof interior socket 230 V (maximum 500 W) Safety kit for water connection. Pre-mounted assembly of reflux prevention device and hose burst protection device BINDER Pure Aqua Service - O - Exchange cartridge for BINDER Pure Aqua Service - O -

Vertically adjustable castors - O - Temperature measurement according to DIN 12880-2 Calibration certificate for temperature and humidity Extension for calibration certificate (additional values) Fanfold chart paper, 1 set Disposable felt tips, 1 set Stable table on castors with locking brakes O O - O Option - not available Technical specifications subject to change BINDER GmbH Postfach 102 D-78502 Tuttlingen Direction: Im Mittleren Ösch 5 D-78532 Tuttlingen Contact: Phone: +49 (0) 74 62/2005-0 Fax: +49 (0) 74 62/2005-100 info@binder-world.com www.binder-world.com