OPERATION MANUAL WARNING TO REDUCE THE RISK OF INJURY OR PRODUCT DAMAGE, READ OPERATION MANUAL PRIOR TO OPERATING PRODUCT.

Similar documents
NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE

Optima ZigBee Thermostat

2 x screws. 2 x wall plugs

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003

SZ-PIR04N ZigBee Motion Detector Installation Guide

Wireless Weather Station

Smart Hub THERMOSTAT. Installation Manual

Automatic Dimming Mirror with HomeLink

ADT. Pulse 2017ADT LLC

TP WEM01 A Carrierr Côr Thermostat AC/HP Wi-Fir Thermostat Performance Series. Installation Guide

Smart THERMOSTAT. Installation Manual

Atomic Digital Office Clock

Wireless External Alarm

Intelligent Home Solutions Quick Start Guide. Monitor your home from anywhere with your smartphone

Rev D 3/20/17

Wi-Fi DOOR/WINDOW SENSOR

Evolve 5.5 cu. ft. Medical-grade Undercounter Refrigerator

ShockLink. Important Product Information.

Model:T83646v2 Quick Setup Guide DC: WIRELESS WEATHER STATION

Embedded Door Sensor. User's Manual. Model SS881ZB. For other language versions, please visit:

XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector

Intelli-Time Alarm Clock model 13041RM

Low Voltage Fan Coil Thermostat ST101ZB. Quick Start Guide. For other language versions, please visit

InTemp CX Temperature Logger (CX40x) Manual

Wireless Outdoor Air Reset Adaptor PN:

1100D Wireless Receiver

CONNEX Smart Thermostat CST R00

1100X Wireless Receivers

Installer Guide smart connect

Installation Guide. Model TBZ48A Battery Powered Z-Wave Thermostat. This thermostat is compatible with most HVAC systems, including the following:

Installer Guide smart connect

EL-TSTAT Owner s Manual

ecobee 3 Quick Start Guide Installation Guide DRAFT

Touchscreen Comfort Control

Pet Immune SAW PIR Motion Sensor

Water Sensor. Model CFWS10

Features and content. This is where air comes into your detector.

SkyNEST WASP Portable Kit, Smart Receiver and SCADA Gateway with Solar Panel USER MANUAL

OPTIMA ZigBee Thermostat

EN1221S-60 Waterproof Pendant Installation and Operation Manual

Caught a critter in the act?

Home Comfort Control with Wi-Fi Model 8910W READ AND SAVE THESE INSTRUCTIONS. Owner s Manual. Includes Operating Instructions and Warranty Information

Testo Digital Vacuum Gauge with Bluetooth. Instruction manual

with motion sensor ITM. / ART Model: LM55811 CARE & USE INSTRUCTIONS IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY

Table of Contents. What s in the Box... 3 Power Requirements... 4 Quick Setup... 5 Lighting Guide With Ring, you re Always home.

Thermometer model 02059

Smart Radon Detector with Indoor Air Quality Sensors Version 1, May 8, 2018

The Digital Door Viewer! User Manual. Motion Activated Sensor MAS 100

Model: WS-9133U-IT Quick Setup Guide DC: WIRELESS FORECAST STATION

Smart Radon Detector with Indoor Air Quality Sensors

Smoke Bridge Owner s Manual

Owner s Manual. PIR-1 IR Learner

HOBO MX Temp/RH Data Logger (MX1101) Manual

Technical support is also available by or by phone: (North America) (International)

Impassa CDMA Module INSTALLATION GUIDE

THB4002. GoTemp Food Infrared Thermometer With Laser Sighting And Thermocouple Jack User Guide. Measuring Temperature The Smart Way.

IMPORTANT SAFETY INFORMATION:

idevices Connected App 4 Battery Replacement 5 Powering On & Off 5 Connecting 6 Mounting 7 Probe Use 7 Probe Wrap Use 9

Draft - develop and review

PET IMMUNE PIR MOTION DETECTOR

programmable control model installation and setup guide M /11/ Hunter Fan Company

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

Testo Digital Vacuum Gauge with Bluetooth

Honeywell Temperature & Humidity Sensor with LCD

Yale Real Living Key Free Push Button Deadbolt B1L Installation and Programming Instructions

Clean Base Automatic Dirt Disposal. For Roomba i Series Robot Vacuums. Owner s Guide

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

S541.RF 4G Product Guide

Responder IV Wireless Bed Interface User s Guide

IMPORTANT. 3-in-1 Weather Sensor model SAVE THIS MANUAL FOR FUTURE REFERENCE. Package Contents

RF2352A, HC2351AC (Discontinued), HC2352AC

TX3 Series. TX3 InSuite. User Guide

Scan the below QR code to download Smart Flame

FEATURES AND SPECIFICATIONS

Weber igrill App 4 Battery Replacement 5 Powering On & Off 5 Connecting 6 Disconnecting 6 Mounting 7 Probe Use 8 Probe Wrap Use 9

How to install your ecobee4

IMPORTANT. Questions? Contact Customer Support at (877) or visit 5-in-1 PRO+ Weather Sensor model

Failure to comply with the following instructions may result in death or serious injury to

Wireless Weather Station. Table of Contents

Performance Thermal Binder

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

Honeywell. Wireless Rain Gauge with Indoor. Temperature (TC152) USER MANUAL TABLE OF CONTENTS INTRODUCTION 3 PRODUCT OVERVIEW 4 REMOTE RAIN GAUGE 7

Projection Alarm Clock

EN1221S-60 Waterproof Pendant Installation and Operation Manual

Weber igrill App 4 Battery Replacement 5 Powering On & Off 5 Connecting 6 Disconnecting 7 Mounting 7 Probe Use 8 Probe Wrap Use 9

Digital Cooking Thermometer models / 00282

GARAGE DOOR OPENER KIT

INSTRUCTIONS FOR. Wireless Refrigerator Freezer Thermometer (#10378)

ZTS-500US Z-Wave Smart Thermostat

Operation and Maintenance Manual

ADC-T2000. Smart Thermostat v1.5

BE1310 Visit Smart hub

Yale Real Living Push Button Deadbolt Installation and Programming Instructions (YRD210)

Color Forecast Station. Table of Contents

Mood Light and Nature Sound Alarm Clock

Wireless Rain Gauge with Rainfall Memory and Digital Clock MODEL: RGR382

Wireless Color Weather Station

Door/Window Sensor Installation Instructions

Wireless Rain Gauge with Indoor Temperature

POWERSHRED. 99Ci. Quality Office Products Since Please read these instructions before use. Do not discard: keep for future reference.

Transcription:

TM OPERATION MANUAL WARNING TO REDUCE THE RISK OF INJURY OR PRODUCT DAMAGE, READ OPERATION MANUAL PRIOR TO OPERATING PRODUCT. PATENT PENDING - COPYRIGHT 2014 - APPION INC. - ALL RIGHTS RESERVED

Introduction AC/R system operating efficiency depends on proper evacuation - and proper evacuation depends on a reliable vacuum gauge capable of monitoring the entire evacuation process. The AV760 accurately displays measurements from atmosphere (760,000 microns) all the way to deep vacuum (10 microns), so you can be sure your system is clean, dry and tight. Table of Contents Safety...3 Display & Controls...4 Using the AV760...5 Bluetooth Operation...6 ION App...7 Maintenance...8 Technical Information...10 Regulatory... 11 Warranty...14 2 AV760 OPERATION MANUAL

Safety Do not connect to systems under pressure. Do not use leaky or damaged batteries. Use only specified batteries and cleaning agents. Battery operating temperatures may vary by manufacturer. The batteries supplied with this unit are for storage and operating between 32ºF-104ºF (0ºC-40ºC). Dispose of batteries in accordance with any applicable local laws and regulations. Do not dispose of the product or battery in a fire or heat above 100ºC. Package Contents (1) Full Range Measurement Wireless Vacuum Gauge (1) 1/4 Female Flare Connector (1) 1/4 MegaSeal Flare Cap with Strap (5) Oil Catch Filters (3) AA Batteries (1) Owners Manual 3 AV760 OPERATION MANUAL

Display 1 2 3 4 5 1- Battery Indicator 2- Auto Power Off 3- Bluetooth Status Controls 4- Measurement 5- Units Press Backlight Power ON Hold Units Power OFF Connect BT Both Toggle APO Timer 1. Press a button for the Press function above. 2. Hold a button for 1 second for the Hold function. 3. Press both Backlight and Power to toggle Auto Power Off (APO) timer feature. 4 AV760 OPERATION MANUAL

Using the AV760 CAUTION: Do not connect the AV760 to systems under high pressure. While the AV760 is designed to withstand accidental exposure to positive pressures, continued exposure may cause permanent damage. 1. Using the Appion Swivel Vacuum Connector (included), connect the AV760 to an available service port furthest from the vacuum pump. 2. Hand-tighten the connections to ensure a tight connection. Never tool-tighten a knurled fitting. 3. Press the Power button to turn on the AV760. A countdown will display while the AV760 starts up and performs self testing. 4. Press and hold the Units button for 1 second to cycle the displayed Units (optional). Tip: Connect to the Side Access Port on a Vacuum- Rated Valve Core Removal Tool with the Appion Swivel Vacuum Connector. Make sure the core depressor side is attached to the Valve Core Removal Tool. Tip: Make sure the AV760 is vertical, with the fitting pointed downward. This will help minimize contamination from any oil that may be pulled out of the system during evacuation. 5 AV760 OPERATION MANUAL

Bluetooth Operation NOTE: Bluetooth communication requires a compatible device running the ION App. Development of the ION App is ongoing, and any information presented in this manual about the ION App may not be up to date. Visit www.appiontools.com or your device s App Store for the latest ION App and additional information. 1. With the AV760 powered on, press and hold the SYNC button for a few seconds, until the Bluetooth symbol begins flashing on the AV760 screen. 2. In the ION App, Scan for devices, and connect as shown in the ION App. When using multiple Appion gauges, it may be easiest to connect all of the gauges first, then disconnect if needed. 3. If the connection is lost due to exceeding the Bluetooth range, or due to loss of power, repeat Step 1, then Reconnect the AV760 through the ION App interface. NOTE: Bluetooth range may vary due to obstructions or interference. The ION App will indicate when communication is lost. NOTE: The AV760 will continue to operate normally even if Bluetooth communication is lost. Tip: Disable Bluetooth connection on gauge and disconnect gauges from ION App to save battery life. 6 AV760 OPERATION MANUAL

ION App The ION App enables remote viewing for appion Wireless Digital Gauges. Reaching a Desired Measurement: In the ALARM subview, set the Low Alarm to the desired micron level. Select OK-Save. Blank Off Leak Test: Isolate the system from the vacuum pump and the evacuation connections. In the ALARM subview, set the High Alarm to the maximum desired micron level (eg. 500 microns). Select OK-Save. Monitor Evacuation Speed: To monitor how quickly an evacuation is proceeding select the Rate of Change subview. If the RoC displays as STABLE, the evacuation has stalled and the oil may need to be changed. Adjust for Elevation: In the Navigation Menu, select Settings, and then select Location Preferences. Turn ON Account for Elevation and adjust settings accordingly. 7 AV760 OPERATION MANUAL

Maintenance The AV760 is a precision instrument and must be maintained to ensure proper functions. If the AV760 sensors get dirty and no longer read correctly, the Sensor Housing can be removed to enable easy cleaning of the sensors. 1. Remove the fitting, o-ring, and the oil catch filter from the sensor housing. WARNING: Do NOT remove the protective screen covering the sensor. 2. Apply Isopropyl Alcohol (70% or higher) to the sensor ports and flush the sensor ports for 5 minutes (page 9). WARNING: Do NOT touch the sensors or insert any objects into the sensor ports. Doing so may permanently damage the sensors. 3. Drain the fluid out of the sensor and apply a short low pressure puff of air, no higher than 50psi, directed at the sensor housing. Let dry for at least 1 hour. 4. Replace the o-ring and lubricate with vacuum oil. 5. Check the oil catch filter for oil by blotting it on a clean tissue or paper towel. If any oil remnants appear, discard the oil catch filter and replace with a new one. 8 AV760 OPERATION MANUAL

Tip: Use every precaution to check the oil catch filter periodically to ensure there is no oil buildup and to prevent gross leaks. 6. Replace the fitting onto the sensor housing port and hand-tighten. Never tool-tighten a knurled fitting. 7. Connect the AV760 to a vacuum pump, and run the pump until display reads 100 microns or less. NOTICE Do not insert any objects into the sensor ports. Doing so may permanently damage the sensors. 9 AV760 OPERATION MANUAL

Technical Information Measuring 760,000 to 1 micron Range Accuracy ± 5% ± 10 microns (1 to 5,000) ± 5% (5,000 to Atmosphere) Resolution 1 micron (1-499), 5 (500-2,000), 50 (2,000-5,000), 250 (5,000-15,000), 1,000 (15,000 and up) Refresh <0.5 seconds Rate Units Microns, mtorr, kpa, mbar, in/hg, psia Power 3x AA Batteries Battery Life 120 hours (continuous usage with radio turned off) Weight 5.9 oz (168.4 grams) Dimensions 4.86 x 2.86 x 1.39 (123mm x 73mm x 35mm) Auto Power After 15 minutes with no change, Off (APO) user input, or Bluetooth activity Warm-up 10 seconds (with self-test) Fitting 1/4 Male Flare Maximum 400 psi (momentary exposure, do Overpressure not leave connected under pressure) Operating 0º to 140º F (-17.8º to 60º C) Temperature Wireless Bluetooth, up to 100ft (30m) line of sight 10 AV760 OPERATION MANUAL

Regulatory Information This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. 11 AV760 OPERATION MANUAL

Regulatory Information FCC Radiation Exposure Statement This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. FCC Caution To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment. Industry Canada Radio Equipment This device complies with Industry Canada licenceexempt RSS-210 standard. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Équipement radio d Industrie Canada Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence. L exploitation est autorisée aux deux conditions suivantes : (1) l appareil ne doit pas produire de brouillage, et (2) l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d en compromettre le fonctionnement. 12 AV760 OPERATION MANUAL

13 AV760 OPERATION MANUAL

Warranty Information Appion Inc. (hereinafter Appion) warrants that this equipment will, under normal and anticipated use, be free from defects in materials and workmanship for a period of one (1) year from the date of purchase by Purchaser from an Appion-authorized distributor. The complete Manufacturer s Limited Warranty is available online at www. AppionTools.com All warranty services must receive Appion Factory Authorization and an RGA number prior to any action. Contact your local Appion authorized distributor to obtain the RGA number and shipping instructions. To help us provide the best service, be sure to have the following information available: Serial number of the equipment Purchase date of the defective unit A detailed description of the problem Appion offers technical and troubleshooting customer support for the lifetime of every product. Regardless of your warranty status, you can always contact us for assistance. Our website includes additional technical information that can help you experience the fullest potential of our products, making your job quicker and easier. Appion AV760 Warranty Registration Card Please complete this card and return it within 10 days of purchase with a copy of your sales receipt. Your Name Your Company Street Address Phone Number City State Zip Email Address Serial Number Place of Purchase Date of Purchase How did you learn about our products? (Please only check one) Wholesaler Recommended By: Magazine Mailing Newspaper Ad Internet Please select your primary line of business. (Check all that apply) Automotive Commercial Residential Service Installation Register by Mail: Appion Inc. 2800 South Tejon Street Englewood, CO 80110 USA Register by Email or Fax: 1. Scan this page AND a copy of your sales receipt. 2. Email to: Sales@AppionTools.com or Fax this page and your sales receipt to: 1-303-937-1599 What features most interested you? (Check all that apply) High Production Low Cost Low Maintenance Portability Ease of Use Other: 14 AV760 OPERATION MANUAL

15 AV760 OPERATION MANUAL

Appion Inc. 2800 South Tejon St. Englewood, CO 80110 USA Tel: 1-303-937-1580 Fax: 1-303-937-1599 www.appiontools.com Sales@AppionTools.com Support@AppionTools.com OM4760 - EN - 2014C