AUXIE - 1S ELECTROPOLISHING UNIT, MODEL E796 HOW IT WORKS SAFETY PRECAUTIONS

Similar documents
PLEASE READ CAREFULLY THE INSTRUCTIONS BEFORE OPERATING

INSTRUCTIONS FOR ELECTROPOLISHER MODEL E1085-1S

ULTRASONIC humidifier

Instructions for Model E782 Betman Cleaning System (Cleaner/Rinser/Rinser/Dryer)

If you are a beginner please feel free to contact us at any time regarding our electroplating course for beginners.

General Safety Rules

Lab Safety. General Safety Rules. General Safety Rules. Glassware Safety. General Safety Rules. General Safety Rules

INSTRUCTIONS FOR OPERATION AND CARE OF

What is wrong with this picture?

Cavitator Ultrasonic Cleaner Instruction Manual Model 20G

Industrial - Remote Reservoir Parts Cleaner Operator's Manual. Read and understand all labels, MSDS, and this instruction manual before use.

Electrical Fireplace Stove with Heater

IMPORTANT SAFETY INSTRUCTIONS

Safety In Chemistry. Identified Risks and Hazards

I N S T R U C T I O N S

USER MANUAL 04-0_MOD-KH1204US_H9 Objecto.indb _MOD-KH1204US_H9 Objecto.indb /06/29 15:02: /06/29 15:02:46

2-IN-1 Warm Mist Humidifier with Steam Inhaler

Manual Parts Washer. Operating Instructions & Warranty Information

Best practices in Cleaning and Safety

Operating Instructions. Oil Column Heater. Models: GOC155, GOC157, GOC1511

I N ST R UC T I ON MODEL 2612 & 2712 SLICERS MODELS 2612 ML ML FORM (12-98) 2612 SLICER

FRYMASTER TCF. Chicken Fryer

K Specifications. Max. Water Volume

Tornado Operations & Maintenance Manual

MANUAL OWNER S. Operating and Servicing Instructions IMPORTANT: READ CAREFULLY BEFORE ASSEMBLY AND USE.

FAILURE TO ADHERE TO THESE WARNINGS CAN RESULT IN FIRE, SERIOUS INJURY, ELECTRICAL SHOCK AND/OR DEATH. Technical Service

Safety In the Science Lab

Humidif ier. Cool Mist. Instruction Leaflet SCM7809-CN PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS FILTER# : BWF100 FILTER TYPE : WICK

INFRARED QUARTZ HEATER

Rules for Safe Operation

FiberPRO. 15 Series. High Pressure Carpet Extractors. Operator and Parts Manual E E E

CONVECTION STEAM OVEN USE AND CARE GUIDE

Zep Dyna Clean Installation and Operator's Manual

USER MANUAL 03-0_MOD-KH1203US_H5_H5.indb _MOD-KH1203US_H5_H5.indb /11/08 21:28: /11/08 21:28:13

INSTRUCTION MANUAL FOR LF-369D TENWERATURECONTROLLED SOLDERING STATION

Operating & Safety Instructions v3.0

K Specifications. Max. Water Volume

1 ESMA, Inc. P. O. BOX 734 * SOUTH HOLLAND, IL * (800) * FAX (708)

Name Science Period 1

USER GUIDE MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY rev.

Superior Spa with Aqua-Aire

Product Code: AP816. User Manual. T: F: Page 1 of 6

Buehler Cast N Vac 1000 Embedding System

Ultrasonic Humidifier

Cavitator Ultrasonic Cleaner Instruction Manual

Advisory Bulletin. TB-106 Cleaning and Maintenance For Bobrick B-850, B-855, B-856 or B-858 Automatic Counter-Mounted Soap Dispensers

Ultrasonic Humidifier DROP. Product Manual

Medical Equipment Washer Information & Setup

1 GALLON / 3.78 LITER ULTRASONIC HUMIDIFIER

Oil-filled Radiator NY23EC-11L User Manual

READ AND SAVE THESE INSTRUCTIONS DE-SCALING SOLUTION. Humidifier De-scaling Solution and Neutralizer. Usage Instructions

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

CYCLONETM ROTARY TUMBLER INSTRUCTION GUIDE

VAPORE 3000 ASPIRA IT IS RECOMMENDED TO CAREFULLY READ THE FOLLOWING MANUAL BEFORE USING THE MACHINE.

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

TR Shower Panel. Operating manual. Hygiene Equipment Designed for People. Serial Number:

IMI Cornelius Automated Beverage System (ABS)

Deluxe Vapor Steamer. Operations Manual

Model: AW600. Triple Action Humidifier. Winix Inc. 120 Prairie Lake Road U nit E East Dundee, IL USA

Hard floor cleaner. Vax careline V-120. Vax model number:

Model K 520 M Part No

PME. Series Enclosures. Battery Enclosure (BE) Field Upgrade Installation Instructions. Effective: January, Alpha Technologies

Annual Tune-Up Procedure

Ultrasonic Humidifier

AI-215 Series Portable Ice Maker

BMW E36 Thermostat Removal And Coolant Flush

Safety Information Contents List Odorox Boss XL3 Unit Operational Guidelines Operating The Odorox Boss XL3... 4

Model K 3000 G Part No

kéìíê~=iqd=qìåöëíéå=dêáåçéê= lééê~íáçåë=j~åì~ä=

FiberPRO 2.5 H. Heated Spot Extractor. Operator and Parts Manual E

Ultrasonic Cool Mist Humidifier

2 BURNER LP GAS STOVE OPERATING INSTRUCTIONS

Ultrasonic Humidifier TALL. Product Manual

ENGLISH (Original instructions) INSTRUCTION MANUAL. Demolition Hammer HM0810TA DOUBLE INSULATION. IMPORTANT: Read Before Using.

CFX-27 GALLON PORTABLE EXTRACTOR. Owner s Manual CFX 1/22/2010

Hand Held Steamer DF-A001 User Manual

Water Distillation System Instruction Manual Nutriteam TC-501

Model K 4400 G Part No High Pressure Washer

INDUSTRIAL - SOLVENT PARTS CLEANER CM200 (115V OR 230V PUMP)

Model 9000 Countertop Steam Distiller

* * English. Operator Manual. Carpet Cleaner Rev. 01 ( ) Model V

EVAPORATIVE COOL MIST HUMIDIFIER Instruction Manual

Humidif ier. Cool Mist Tower. Instruction Leaflet. pure indoor living. MODEL: BCM631 Series FILTER# : BWF100 FILTER TYPE : WICK

EVAPORATIVE AIR COOLER SERVICE MANUAL

Owner s Manual SPLIT-TYPE ROOM AIR CONDITIONER

INFRARED QUARTZ HEATER

Model HD 3501 Part No High Pressure Washer Operator Manual

Dehumidifier. Model: GDN20AX-K4EBA1A GDN20AX-K4EBA1B

K 3.97 M. Specifications or visit our website: In USA call: Part No

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

Owners Manual for the AV18AX

Safety procedures: Wear your PPE. Gloves and goggles when filling the chemical bottle, using the machine, and cleaning the machine.

DEHUMIDIFIER. User Manual 50BT, 70BT

INDUSTRIAL VACUUM CLEANER WITH AUTO START/STOP

Prolux Tritan INSTRUCTION MANUAL

Penner Stationary Patient Lift Safe Operation & Daily Maintenance Instructions

Ireland. Australia. New Zealand

Electric Fireplace Insert with Heater OWNER S MANUAL Model No. FP404R-Q

Humidifier De-scaling Solution. and Neutralizer. Usage Instructions. IMPORTANT: Read and save these instructions. Before

GDDEM10 DEHUMIDIFIER

Transcription:

1

ESMA, Inc. 750 W. Taft Drive PO Box 734 South Holland, IL 60473 708-331-1855 800-276-2466 FAX 708-331-8919 INSTRUCTIONS FOR Model E796 Auxie-1S AUXIE - 1S ELECTROPOLISHING UNIT, MODEL E796 The Auxie-1S unit is intended for labs that cast up to 5 partials per day. For higher daily volumes we recommend our automated electropolishers that will polish 3 to 5 partials at a time. In the AUXIE units approximately 50% of the current ( juice ) is directed into the deep palate, resulting in uniform shine and substantially reduced attack on the clasps. Even the deepest palate of the largest horseshoes will attain a high uniform luster. FOR BEST RESULTS, FINE-STONING, FOLLOWED BY SAND-BLASTING IS ABSOLUTELY NECESSARY. HOW IT WORKS Partial, clean of investment, moisture, oils, and foreign matter, is attached to holding device, with the auxiliary (additional) cathode position ½ to ¼ from the point of deepest recess of the partial s palate. Device with partial is then mounted and treated for 30 minutes (followed by rinsing). SAFETY PRECAUTIONS The solution, although without volatile corrosive components, is acidic and presents hazards: Avoid contact with skin, if contacted - rinse off with plenty of water. Avoid contact with eyes: wear safety goggles when pouring or removing tank; if contacted - rinse with plenty of water; seek medical attention. Solution will damage clothes and carpeting. A small amount of solution is emitted during polishing as mist; avoid inhaling, install near draft, exhaust or ventilated area. No corrosion will occur if ESMA-BRITE solution is used: corrosive damage will occur with many other solutions. INSTALLATION 2

Install near sink and ventilated area. Place cathode in jar (see diagram 1) and place jar into recess of cabinet. Connect cathode clip (left side of unit) to cathode rod. Pour ESMA-BRITE solution into jar to approximately 1½ below top of jar. Solution should not touch plastic block of holding assembly. Connect cord of unit to properly grounded 3-prong, 120 VAC outlet. OPERATION Turn unit ON and heating of solution will begin. The solution temperature will control at approximately 120 degrees F but it will take one hour minimum to reach this temperature. If the first partial of the day is polished while solution is still heating, just increase polishing time of first partial. NOTE: If during heat-up you notice an odor, it is possible that solution was spilled on the heating platform; shut off unit, remove tank and after heating platform has cooled, wipe off any solution present on platform and tank (wipe off remnants of solution with clean wet {water} cloth). If odor persists repeat the procedure and if no improvement, tank may be leaking (contact manufacturer). Attach partial to holder 13N with lingual side facing auxiliary cathode 35L(see diagram 2). Cathode 35L should be positioned ¼ to ½ from the deepest recess of partial; the vertical position of auxiliary cathode is fixed by adjusting wing nut 23F. For the polishing of small attachments, clasps, etc., a clip (part 30D) with a welded extension wire can be purchased. This clip with wire are made of a special alloy. Loosen wing nut 23E that secures partial to holder, and attach clip with wire to it. There is no need to remove the partial holder. Retighten the wing nut, making sure that the clip DOES NOT TOUCH the auxiliary cathode. Reduce the polishing time to 10-15 minutes, depending on the size of item to be polished. AUXILIARY CATHODE MUST NOT TOUCH THE PARTIAL (SHORT-CIRCUIT!) Mount holding assembly with attached partial on top edge of glass jar (see diagram). Insert red and black plugs into their respective sockets located on right side of unit. Turn the timer clockwise to the required setting and polishing will begin. (Gas bubbles should be visible at the cathodes). We recommend 20 minutes polishing for a lingual bar and 30 minutes for a medium horseshoe at the 120 degree F temperature. Longer polishing times maybe required if solution is cold or a large horseshoe is being polished. 3

END OF TREATMENT End of treatment comes with the lapse of time on timer. A partial can be left for some time in the solution after completion of polishing with no danger of damage. Unplug red and black wires from right side of unit and remove holding assembly with partial from jar. Partial and clip 13N should be rinsed under water before partial is removed from clip. **FINE STONING To get the maximum shine on your partials, it is necessary to fine-stone the partial prior to electropolishing. Only if you fine-stone and sandblast the partial, will you eliminate most of the manual rubber wheeling and highshinning. Several labs who have our AUXIE units report good results when stones manufactured by BRASSELER USA, INC. were used. The recommended stones are: Large Barrel 731-330. Taper Barrel 733-330 and inverted Cone 735-330. Free samples of these stones are enclosed along with ordering information. CAREFUL FINE-stoning is the key to labor saving. MAINTENANCE According to reports from dental labs, it is possible to get up to 100-125 quality polished partial with one gallon of ESMA-BRITE (results vary from lab to lab and this figure should not be considered as binding on us in any way). Disconnect cathode clip from jar cathode rod. Slowly lift jar out of unit. Dispose of solution according to local regulations. Rinse and clean jar and dry with towel. Place jar back into cabinet and refill with ESMA-BRITE. The cabinet is made of Stainless Steel. The finish can be restored by using a commercially available cleaner for kitchen appliances. The holding assemblies need to be cleaned in 1-2 months depending on volume of work. During the electropolishing, the evolving gases carry a mist of ESMA-BRITE solution, which precipitates on various parts of the holding assembly. Procedure for cleaning: loosen all connections of holding assembly, rinse with hot running water, use mild detergent and brush especially at joint and connections. EXCHANGE OF ESMA-BRITE SOLUTION Dental Labs realize outstanding savings with our Auxie electropolishers for Chrome Partials.The savings can be achieved only with our ESMA-BRITE 4

solution. Other solutions, some containing volatile corrosive components, may damage the unit but most important, not produce the superior results that warranted the purchase of the AUXIE in the first place. Generally, good shine should be achieved up to 100 partials per gallon of ESMA BRITE. This will vary depending on the amount of water introduced into solution and the cleanliness of the electrical connections. When humid conditions exist, leaving unit on will keep solution warm to slow down the moisture pickup by solution. For any technical information or cleaning supplies call 1-800-276-2466. 5

6