Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Similar documents
Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Technical Product Guide

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

Technical Product Guide

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

InverterFlex SERIES InverterFlex Systems condition up to five rooms

HEAT PUMPS. Efficient Comfort For Every Season

Ductless Split Systems Concealed Duct Heat Pumps

Ductless Split Systems Ceiling Cassette Heat Pumps

Samsung 360 Cassette, Single Zone, Split System

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

THE WORLD S MOST EFFICIENT HEAT PUMP

Residential and Light Commercial Ductless Systems Catalog

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Single and Multi-Zone Ductless Split Systems

InverterFlex SerIeS InverterFlex Systems condition up to five rooms

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

Ductless Split Systems Wall-mounted, Multizone Heat Pump

Geniuses at work. Residential Mini Splits

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems

PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems

SUBMITTAL DATA: MSY-GL24NA & MUY-GL24NA 24,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM. System Reference:

SUBMITTAL DATA: MSY-GL12NA & MUY-GL12NA 12,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM. System Reference:

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

2017 LINE UP MINI SPLITS CATALOG

Product Data INDUSTRY LEADING FEATURES / BENEFITS

A single answer for multiple zones.

DESIGN & TECHNICAL MANUAL

ductless mini-splits light commercial and multi-zone systems product catalog ALEGRIA ALEGRIA

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SUBMITTAL DATA: MSZ-FH06NA & MUZ-FH06NA 6,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM. Electrical Power Requirements. Indoor / Outdoor A 1 / 11

2017 LINE UP MINI SPLITS CATALOG

DUCTLESS MINI-SPLITS LIGHT COMMERCIAL AND MULTI-ZONE SYSTEMS PRODUCT CATALOG ALEGRIA ALEGRIA SERIES ALEGRIA

A single answer for multiple zones.

Well rounded. 360 CASSETTE. A truly circular cassette. Enjoy even airflow from a beautifully sleek design that fits into any setting.

DUCTLESS SPLIT MULTI DUCTLESS SPLIT PACKAGED TERMINAL (PTAC) THROUGH-THE-WALL ROOM (TTW)

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MA*R Outdoor Unit Single Zone Ductless System Sizes 09 to 36

Submittal Data Sheet

Up to SEER 26.1 Wall Mount Heat Pump

SERIES. Ductless Split Comfort Systems. Mark of Superior Quality ADVANCED TECHNOLOGY ENERGY SAVINGS ECO-FRIENDLY NEW RESIDENTIAL LINE

SUPERIOR COMFORT FOR THE GLOBAL MARKETPLACE

DESIGN & TECHNICAL MANUAL

DUCTLESS FULL LINE CATALOG

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5

HEATING AND COOLING DUCTLESS SPLIT MULTI DUCTLESS SPLIT PACKAGED TERMINAL (PTAC) THROUGH-THE-WALL (TTW)

1 TECHNICAL CHANGES. MUZ-A09NA MUZ-A09NA - 1 MUZ-A09NA - U1 MUZ-A09NA - U2 1. Refrigerant system diagram has been changed.

Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center

TECHNICAL SPECIFICATIONS

LV Series. SEER 20+ Wall Mount Heat Pump

Lennox 8 Series Single Zone - R-410A

SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Multi - Zone Systems. Specification and Performance. 208V-230V 18k-36k. Presents

CARRIER DUCTLESS & VRF SYSTEMS. What s Next in Comfort

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

Ductless Systems. Right product for the right application

SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

Room Air Conditioner SVC MANUAL(Exploded View)

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7

DESIGN & TECHNICAL MANUAL

Inverter Wall Mounted Series

Specifications, Performance & Submittal

Air Conditioning & Heating. Ductless Product Catalog

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

SUBMITTAL DATA: PVA-A36AA7 & PUZ-HA36NHA5 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference:

SUBMITTAL AG015KSVAJH/AA Samsung DVM Heat Pump Chiller. Submitted to Reference Approval Construction Unit Designation Schedule #

KE Series. SEER 14+ Wall Mount Heat Pump or Cooling Only

Mini Splits Catalog SINGLE ZONE

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/ , Single Phase

SUBMITTAL DATA: PEAD-A30AA7 & PUZ-A30NHA7(-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A30NHA7

SUBMITTAL DATA: SLZ-KA09NA & SUZ-KA09NA 9,000 BTU/H CEILING-CASSETTE HEAT-PUMP SYSTEMS. Cooling 4. Heating

FAQ. Wall Mount Heat Pump or Cooling Only

K sin. Mini Split Air Conditioners and Heat Pump

SERVICE MANUAL MUZ-FE09NA MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-F.

WJH4 Product Specifications

READ ONLY. American Standard Ductless Systems Product Catalog. A Comfortable, Convenient Solution Built To A Higher Standard.

BENEFITS. Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056

FBQ. DC Duct Heat Pump or Cooling Only

duct-free air conditioning systems Art cool inverter flex multi-split

Engineering Data Book

Transcription:

Submittal Data: Innovative Ductless solutions 12,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Compact and Quiet Design -High Efficiency DC Inverter Technology -Wireless Remote with LCD Display -Wi-Fi Ready (Sold Separately Kit PN: WSBEC02) -XK-41 Wired Tether Controller (Sold Separately) -Low Ambient Cool to 0 deg F -Blue Fin Condenser Coil -5 year Limited Parts Warranty Reference Approval Construction AHRI Certified Ref No: 9959454 System Ratings Indoor Unit Data Cooling Fan Motor Type Cross-Flow Rated Capacity 12,000 BTU/H Output Power 20 W Capacity Range 3,100-13,000 BTU/H FLA 0.1 A Power Input (Max) 1,350 W Airflow SEER 22.0 Cooling Wet (Lo/Hi) 171/400 CFM EER 12.5 Heating Dry (Lo/Hi) 171/400 CFM Heating at 47 F Rated Capacity 13,000 BTU/H Sound Power Level Capacity Range 2,400-14,000 BTU/H Cooling (Min/Max) 29/45 db(a) Power Input (Max) 1,400 W Heating (Min/Max) 29/45 db(a) HSPF 11.0 COP 3.5 Dehumidification 2.96 pt/hr Heating at 17 F Rated Capacity 7,100 BTU/H Outdoor Unit Data Compressor Type DC Inverter Driven Rotary Operating Range RLA 6.6 A Cooling (Max) 115 F (46 C) (Min) 0 F (-18 C) Refrigerant Type R410A Heating (Max) 75 F (24 C) Fan Motor Output Power 30 W (Min) -4 F (-20 C) FLA 0.36 A Refrigerant Piping Data Gas Pipe Size (OD) 1/2-in Sound Power Level Liquid Pipe Size (OD) 1/4-in Cooling/Heating 54/54 db(a) Connection Method Flared Electrical Data Factory Charge 47.6 oz Power Supply Additional Charge 0.21 oz/ft Normal Operational Voltage 208/230 V, 1 Phase, 60 Hz Pre-Charge Length 25-ft Voltage Range 187-253 V MAX Refrigerant Pipe Length 66-ft MCA 9.0 A MIN Refrigerant Pipe Length 10-ft MOCP/Breaker Size 15 A MAX Refrigerant Pipe Elevation 33-ft Main Power Wire Size 14-2 AWG

Features & Function Summary SYSTEM FEATURES Inverter Type Ultra Low Frequency Torque Control Power Factor Correction Compressor Type Refrigerant Type Basepan With Electric Heater Compressor With Electric Heater Outdoor Fin Coating Intelligent Defrosting Intelligent Preheating Low Voltage Startup Memory/Power Failure Recovery Self Diagnosis Wired Controller Interface (XK-41) Wi-Fi Interface Capable Indoor Fan Type Multi Fan Speeds Indoor Unit Display Advance Filter Auxiliary Electrical Heater Ventilation (Outdoor Air) G10 Yes Yes High Eff. Rotary R410A Blue Fin Optional (see PN: WSBEC02) Crossflow 4 Speeds Optional (see Filter Kits) REMOTE CONTROLLER FUNCTIONS Auto Mode Auto Fan Auto Swing (Horizontal Auto Swing) Auto Swing (Vertical Auto Swing) Clock on Remote Controller Dry Mode Dry Anti-Mildew (X-Fan) Mode Energy Saving Mode Dirty Filter Alert I Feel Function Lock on Remote Controller Quiet Mode Room Temperature Display Sleep Mode 4 Sleep Modes Options Timer Mode Turbo Mode Display On/Off Control Freeze Guard Mode Display On/Off Control Freeze Guard Mode

EXTENDED RATINGS Outdoor Ambient DB COOLING PERFORMANCE (BtuH)* Indoor Ambient Temperature 68F DB (20C) 73F DB (23C) 80F DB (27C) 82F DB (28C) 57F WB (14C) 61F WB (16C) 67F WB (19C) 68F WB (20C) TC SHC TC SHC TC SHC TC SHC 5 o F 7,656 6,005 8,088 6,341 9,128 7,159 9,508 7,458 14 o F 7,852 6,159 8,292 6,503 9,476 7,431 9,871 7,740 23 o F 8,388 6,580 8,972 7,038 10,280 8,063 10,708 8,399 32 o F 10,172 7,978 10,880 8,533 11,916 9,343 12,413 9,732 41 o F 11,520 9,035 12,240 9,598 13,080 10,259 13,625 10,686 50 o F 11,384 8,930 12,108 9,497 12,960 10,166 13,500 10,589 59 o F 11,104 8,707 11,824 9,274 12,840 10,072 13,375 10,492 68 o F 10,824 8,488 11,544 9,055 12,600 9,882 13,125 10,294 77 o F 10,548 8,273 11,264 8,833 12,360 9,696 12,875 10,100 86 o F 10,244 8,034 10,960 8,594 12,000 9,412 12,500 9,804 95 o F 9,996 7,840 10,708 8,399 11,844 9,290 12,338 9,678 104 o F 9,748 7,645 10,460 8,205 11,688 9,169 12,175 9,551 113 o F 9,248 7,252 9,960 7,812 11,192 8,776 11,658 9,142 Outdoor Ambient DB 68F DB (20C) 57F WB (14C) HEATING PERFORMANCE (BtuH)* Indoor Ambient Temperature 73F DB (23C) 80F DB (27C) 61F WB (16C) 67F WB (19C) 86F DB (30C) 72F WB (22C) TC SHC TC SHC TC SHC TC SHC -4 o F 6,821 6,821 6,756 6,756 6,642 6,642 6,374 6,374 0 o F 7,390 7,390 7,321 7,321 7,199 7,199 6,902 6,902 6 o F 7,796 7,796 7,723 7,723 7,593 7,593 7,280 7,280 10 o F 8,121 8,121 8,044 8,044 7,910 7,910 7,585 7,585 16 o F 8,365 8,365 8,288 8,288 8,149 8,149 7,812 7,812 19 o F 8,531 8,531 8,446 8,446 8,308 8,308 7,963 7,963 24 o F 9,478 9,478 9,397 9,397 9,254 9,254 8,913 8,913 32 o F 10,583 10,583 10,502 10,502 10,359 10,359 10,018 10,018 41 o F 11,846 11,846 11,765 11,765 11,627 11,627 11,282 11,282 43 o F 12,163 12,163 12,082 12,082 11,940 11,940 11,598 11,598 47 o F 13,264 13,264 13,130 13,130 12,903 12,903 12,342 12,342 53 o F 13,398 13,398 13,260 13,260 13,028 13,028 12,464 12,464 59 o F 13,703 13,703 13,565 13,565 13,325 13,325 12,748 12,748 64 o F 13,995 13,995 13,853 13,853 13,609 13,609 13,020 13,020 70 o F 14,259 14,259 14,113 14,113 13,869 13,869 13,268 13,268 75 o F 14,458 14,458 14,312 14,312 14,060 14,060 13,451 13,451 * Maximum system capacity TC- Total Capacity ( BtuH) SHC- Sensible Capacity (BtuH)

DIMENSIONAL SPECIFICATIONS MINIMUM SPACING REQUIREMENTS Units: inch (mm) INDOOR Units: inch (mm) OUTDOOR

DIMENSIONAL SPECIFICATIONS INDOOR UNIT DIMENSIONS Model No: H Units: inch Dimensions A 33.4 B 11.4 C 8.2 Weight (Net/Gross) Liquid Line Valve Gas Line Valve Drain Connector 22.1/26.5 lbs 1/4-in OD Flared 1/2-in OD Flared 5/8-in OD OUTDOOR UNIT DIMENSIONS Model No: O Units: inch Dimensions A 21.3 B 12.6 C 21.3 D 33.4 E 11.3 Weight (Net/Gross) Liquid Line Valve Gas Line Valve 86.0/93.0 lbs 1/4-in OD Flared 1/2-in OD Flared Notes: 1. Recommended Interconnecting Cable Type 14 AWG-4 Stranded Copper Conductors THHN 600V Wire 2. Power wiring cable size must comply with applicable national and local codes. 3. Test conditions are based on AHRI 210/240. Specifications are subject to change without notice. Manufacturer reserves the right to discontinue or modify specifications or designs without notice or without incurring obligations. All rights reserved. Cat No. GREE_VIREO_B_SUBMITTAL_12MBH_230V_111218