STANDARD RELEASE PANEL OPERATING & MAINTENANCE MANUAL

Similar documents
SRP4x4 STANDARD RELEASE PANEL OPERATING & MAINTENANCE MANUAL. An ISO 9001:2008 Registered Company

FIRE DETECTION CONTROL PANEL OPERATING & MAINTENANCE MANUAL

TECHNICAL DATA OBSOLETE

Commercial and Light Industrial Fire Alarm Control Panel

30.45 Electric Release PDRP-2001

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

Installation Guide for models:

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

MR-2602 Two Zone Fire Alarm Control Panel

Installation Guide for models:

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

Specification/ Data Sheet

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

PSN-1000 & PSN 1000(E) Installation Manual

FireNET Plus Wiring Instructions

Series. Access Power Controllers. Installation Guide

Booster Power Supply Manual

AL800ULADA. NAC Power Extender. Installation Guide

AL600ULADA. NAC Power Extender. Installation Guide

Release Control Fire Alarm Systems

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

INSTALLATION GUIDE XR5FC AND XR5SL COMMERCIAL FIRE PANELS

RELEASE DEVICE CONTROLS

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

Public Safety DAS Annunciator Panel

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

SP-1000X. Panic Device Power Controller Installation Guide. Rev

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

Electric Release Panel Wiring Tips

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

MODEL B2 INSTALLATION MANUAL

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description.

Access Power Controllers with Power Supplies

Installation, Operating and Maintenance Manual

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

Fire Control/Communicator

SILENT KNIGHT. Model SK-2/E & SK-4/E. Installation and Operations Manual. Fire Alarm Control Panel. Part Number Rev. A ECN /08/05

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Conventional Releasing Control Panel

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

AL600ULX Series. Power Supply/Charger. Installation Guide

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Model 17A00 Expansion Enclosure

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Remote NAC Power Supply D7038

VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

E S L I N S T A L L A T I O N A N D O P E R A T I O N S M A N U A L ESL Fire Alarm Control Panel ESL

4100U City and Relay Cards Installation Instructions

good things in small packages

December Scorpio. Fire Control Panel. Installation, Operation & Maintenance Manual. P/N UL Listing File No. S2422.

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM

Instruction Manual. CMP-12/24 Fire Alarm Control Panel. 12 Clintonville Road, Northford, CT DOCUMENT /11/96 REV: D1

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

ANNUNCIATOR FIXED MODULE

CMP-2401B/CMP-2402B. Fire Alarm Control Panel. Installation, Maintenance and Operating Instruction Manual

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

FA-1000 SERIES. Microprocessor-Based Fire Alarm Control Panel. Installation and Operation Manual

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

FCPS-24F FIRE ALARM FIELD CHARGER/POWER SUPPLY FOR FIRE PROTECTION/SIGNALING SERVICE FCPS-24F/FCPS-24FE. Field Charger/Power Supply

The MS-4412B/MS-4424B(E) FIRE ALARM CONTROL PANELS

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

FireSeeker Fire Alarm Control Panel Model FS-250 Installation, Operation and Maintenance Manual

LiftMaster 300 Windsor Drive Oak Brook, IL LiftMaster.com

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

EVO192 v3.0 Fire and Burglary What s New

Transcription:

SRP4x4 STANDARD RELEASE PANEL OPERATING & MAINTENANCE MANUAL APPROVED An ISO 900:008 Registered Company

IMPORTANT SERVICE NOTICE When requesting service assistance, or to order parts for this control panel, you are required to provide the Model Number, Drawing Number and Serial Number. This product information is recorded on the Panel Identification Label located inside the control panel. Please have this information available before calling your Authorized Protectowire Distributor or the Factory.

Table of Contents General Information & Panel Specification Company Information / Publishing Date... Notice & Warnings... System Description & Features... 4 Systems Specifications... 5-6 Enclosure Information Enclosure Dimensions... 7-9 Panel Mounting... 0 Battery Cabinet Mounting... Wiring Wire Routing Detail (Power Limited vs Non-Power Limited)... Wire Size Estimator... Field Wiring (Initiating Device Circuits)... 4 Field Wiring (NAC & Solenoid Release Circuits)... 5 Options Alarm Point Location Meter (PDM-000-4)... 6 Auxiliary Relay Module (RB-4)... 7 Class A Alarm Notification Module (AM-9-)... 8 Installation / Troubleshooting Installation Test & Maintenance... 9 Troubleshooting... 0-4 Programming Wire Diagram Program Chart... 5-9 Battery Calculations Battery Size Selection Chart... 40 Panel Instructions (tearout)... 4 Appendix A Listed Solenoids, Notification Appliance Devices, Listed Smoke Detectors... 4-44

The Protectowire Co., Inc. 60 Washington Street, Pembroke, MA U.S.A. 059-8 Telephone: -78-86-878 Fax: -78-86-045 WWW.PROTECTOWIRE.COM Model SRP-4x4 Standard Release Panel Operating & Maintenance Manual Man-00 Rev. C Publish Date 08-04-06

Notice TESTING AND MAINTENANCE OF CTROLS SHALL BE PERFORMED BY COMPETENT PERSNEL HAVING JURIICTI OVER THIS PROTECTIVE SIGNALING. TESTING ZES WITH SOLENOID RELEASE CIRCUITS AND EQUIPMENT SHUTDOWN CTACTS MAY BE ACCOMPLISHED BY USE OF A JUMPER WIRE ACROSS EACH DETECTI / INITIATING CIR- CUIT FIELD WIRING TERMINALS LY AFTER THE DISCNECT SWITCH, LOCATED IN THE LOWER LEFT CORNER OF MAIN BOARD, HAS BEEN PLACED IN THE LEFT POSITI. SLIDING THIS SWITCH IN THE LEFT POSITI ALLOWS SIGNALS FOR OP, OP, AND OP4 TO BE BYPASSED. NOTE: IT IS ALWAYS GOOD PRACTICE TO DISCNECT ALL PRE-ACTI S PRIOR TO TESTING. WARNING! FATAL ELECTRICAL SHOCK AND EQUIPMENT DAMAGE MAY RESULT FROM FAILURE TO REMOVE ALL POWER PRIOR TO SERVICING. CAUTI The Protectowire Co., Inc. designs and manufactures fire protection systems to meet both UL and FM Global criteria for electrical transients introduced on both the power supply side of the system and into the panel from field wiring for initiating device circuits, notification appliance circuits, and other external field routed wiring. Fire protection systems located in areas subject to lightning strikes, or subject to other severe transients, and electromagnetic interference, should be protected similar to computers and other electronic systems with supplemental surge and filter protection both on the power supply side and on field wiring for initiating device circuits, notification appliance circuits and other field routed wiring. Please refer to surge/filter manufacturers, (eg., DITEK 800-75-45, www.ditekcorp.com) to specify devices for your particular conditions. The National Lightning Safety Institute (www. LightningSafety.com) also provides valuable information regarding the problems and solutions of providing lightning protection including assuring true earth ground conditions. Lightning strikes, other severe power surges, and significant EMI/RFI interference, by their nature, are beyond normal design criteria and are outside the warrantee for manufacturing defects.

MODEL SRP-4x4 STANDARD RELEASE PANEL System Description & Setup The Model SRP-4x4 is a Fire Alarm Control/Releasing Panel which is FM approved, UL Inc. Listed. It is designed primarily for use as a releasing panel for Pre-action and Deluge, water based extinguishing systems. This unit is in compliance with NFPA-, NFPA-7, and UL864 and can be used as a stand alone Fire Control Panel. The Fire Control Panel is programmable by way of three () eight (8) position DIP switches. Select a system programming scheme that meets your requirements as depicted on pages 5 thru 9. Special attention must be taken in positioning dip switches for proper panel operation. System Features Four (4) Supervised Class A (style D) or Class B (style A or B) Initiating device circuits which may be configured for the following functions.. Standard Initiating Device Circuits Compatible with the following: a. Up to 0,000 Feet (,048m) of Protectowire type PHSC linear heat detector. b. Up to 5 (0.045mA) Hochiki smoke detectors. c. Any combination of Normally Open contact initiating devices. Examples: Conventional Manual Pull Stations, Waterflow Switches, Conventional Spot heat detectors.. Supervisory Initiating Device Circuits Compatible with the following: a. Any combination of Normally Open contact initiating devices. Examples: Low air pressure switches, Valve Tamper Switches. Four (4) Supervised Class B (Style Y) Output Zones: Each Output can be set up for any of the following: ) Notification Appliance Circuit (Output # thru #4) ) Release circuit (Outputs #,, and/or 4) ) Supervisory Bell circuit (Outputs # & 4 only) 4) Trouble Bell circuit (Output #4 only) - Releasing Zones can be set up for either single or cross zone operation - All circuits are inherently Power-Limited per NFPA 70 (nec) see 760 - Initiating circuits can be wired as Class A or B - Output circuits #,, and 4 have disable feature - Signal Silence Button (common alarm and/or trouble conditions) - System Reset Button - Built-in Trouble/Supervisory Buzzer - Auxiliary Contacts for Alarm/Trouble/Supervisory - On Board 4V Auxiliary Power (00mA MAX) Resettable - Ground Fault Detection (.K ohms to Ground) - Battery Trouble circuit (low battery, battery overcharge, battery disconnect) - 4 or 90 hour Battery Standby operation available Options: ) AM-9- Module: converts Class B Notification Appliance circuit to Class A ) PDM-000-4 Protectowire Digital Alarm Point Location Meter. ) RB-4 Auxiliary Alarm Relays 4

SPECIFICATIS Housing Type: 6 gauge steel. Door: Piano Hinged, lockable. Dimensions: 0 / x 4 /4 x 4 /4 Finish: Red enamel with red, black and white logo/label. Knockouts: Minimum of one / and two /4 knockouts on each side, top and bottom. Visual Indicators (Visible LED s with door closed) AC-: () Green System Silence, System Trouble, Ground Fault Detection, Battery Trouble, and Output Disconnect Supervisory: (5) Yellow Common Alarm: () Red Supervisory Zone Alarm: () Yellow Input and Output Zone Trouble: (9) Yellow Input and Output Zone Alarm: (8) Red Control Buttons Signal Silence: Momentary - Silences alarm signaling circuits, trouble buzzer and outputs programmed as supervisory bell or trouble bell. System Reset: Momentary - Resets all alarm circuits if condition has been corrected. Removes power from initiating circuits. Initiating Device Circuits (4 TOTAL) 4 NFPA Style D (Class A) or Style B (Class B) Power-limited IDC loop current (IDC): 0. ma. IDC alarm trip current: 6.0 ma minimum. IDC alarm current (short circuit): 44 ma max. Normal loop voltage: VDC Linear heat detector resistance: 000 ohms max. Maximum Impedance to insure Alarm:.4K ohms. End of Line Resistor: - (Required in Class B configuration only) Two Wire Detector capacity (per zone): 5-0.045 ma type Hochiki smoke detectors Low/Disconnected Battery Battery and system trouble indication when voltage falls out of range between -9 Volts, or has been disconnected Fused battery and reverse polarity protection is provided. Conditioning Resistor:. K ohm (Remove and replace with batteries) 5

SPECIFICATIS (continued) Output Circuit (4 TOTAL) ( INDICATING, RELEASING, AND ) 4 Supervised Notification Appliance Circuits (NAC) Class B, reverses polarity on alarm (Optional Class A Module: AM-9-). Maximum line loss not to exceed.0 Volts or Ohm fully loaded. Power-limited, each circuit has self-resetting type fuse (PTC). Output #; Dedicated for Notification Only; rated 4V FWR regulated, amp continuous. Outputs #, & 4 rated 4VDC regulated, amp each,. amps combined for Solenoid activation. Per UL listings circuits are rated.5 amps each,.75 amps combined for Notification Devices Standby terminal voltage approximately -.7VDC. End of Line Resistor - ohms. Compatible Solenoids: FM Solenoid Groups A, B, D, E, F, G, I, J & K For UL see Appendix A for compatible Solenoids. Supervisory Circuit ( TOTAL) Supervisory monitors the following: High/Low Air Tamper/Valve positioning and etal One latching Class B Supervised Initiating Device Circuit. Power-limited. End of Line Resistor - ohms. Circuit loop resistance 00 ohms. Increase in circuit resistance causes supervisory trouble and system trouble. Maximum resistance for supervisory signal 00 ohms to insure alarm. Minimum current 4.5 ma to insure alarm (0 ma short circuit maximum). Normal supervisory standby loop current ma. Normal standby loop voltage 9.5VDC. Input Power 0VAC -.7 Amp max. (50-60 Hz) or 40VAC -.85 Amp max. (50-60 Hz) Green AC- LED goes off with AC power loss, causes system trouble and buzzer to sound. System on battery backup. System Trouble is also generated if voltage drops below 0V under alarm load, system is transferred to battery backup. Power Requirements Standby - 60 ma @ 4VDC, 7.0 AMP Batteries for 4 hour standby - 60mA @ 4VDC, 8.0 AMP Batteries for 90 hour standby (FM Requirement) Alarm -.5 AMP MAX. @ 4VDC All Zones. Battery Charger Specifications: 7 VDC @.ma trickle; Amp fast charge. AH Battery maximum, sealed rechargeable type. Outputs System Remote Signaling Relay contacts rated A, 0VDC (resistive) for Alarm, Supervisory & Trouble. Auxiliary Power - 4VDC regulated. Rated 00mA max. Power-limited. (Resettable) 6

9.87.06 4..00 Ø0.8.06 Ø0.6 Ø0.8 ENCLOSURE DIMENSIS IMPORTANT: The stated dimensions are for the enclosure back box only and do not account for the overall dimensions of the enclosure with the door installed. To account for the enclosure door and hinges add an additional 0.4 to the back box width, and 0.08 to the depth. 0.60 Caution: Do not drill through the top of the enclosure for conduit entry. Metal filings will damage system components and voids factory warranty. Use knockouts provided and seal all conduit openings to prevent water ingress. 4..75.06 0. 0. FRT VIEW BACK VIEW 7

ENCLOSURE DIMENSIS IMPORTANT: The stated dimensions are for the enclosure back box only and do not account for the overall dimensions of the enclosure with the door installed. To account for the enclosure door and hinges add an additional 0.4 to the back box width & height, and 0.08 to the depth. Caution: Do not drill through the top of the enclosure for conduit entry. Metal filings will damage system components and voids factory warranty. Use knockouts provided and seal all conduit openings to prevent water ingress..5.5.0. 4.6 TOP/BOTTOM VIEW.5.5 4.5.0 0.88. 0.88 KNOCKOUTS 7.5 0...5 0.88 4.5.0.5 LEFT/RIGHT SIDE VIEW 8

ENCLOSURE DIMENSIS 4.40 0.64 0.40 DOOR FRT/SIDE VIEW 9

OUT. DISC. SUPVISRY AC GND FLT BATT TRO COM GENERAL ZE ZE ZE ZE SUPVRY. PANEL MOUNTING - Panel shall be located in a clean, dry, vibration free environment. Panel shall not be subjected to extreme temperatures or humidity. 4 4 FIRE CTROL PANEL - Panel shall be wall mounted only, with the top of enclosure at a height of 6 feet. Secure the panel using the mounting holes provided. - The panel must be easily accessible for maintenance with no physical obstructions blocking it s access or visual operation. - The panels hinged door requires an additional 6 inches of free space. This additional space allows the front door to be fully swung open. - Do not drill through the top of the enclosure for conduit entry. Metal filings will damage system components and voids factory warranty. Use knockouts provided and seal all conduit openings to prevent water ingress. - Once panel has been mounted connect all required conduit, field wiring, detection circuits, audible devices and/or solenoid valves. Lastly connect input and battery back-up power. 9.8.8 0.60.0.6 - Follow the Installation, Testing and Maintenace procedure for complete testing and operations of installed system. 0 0.8 0

- CIRCUIT BREAKER BATTERY TRANSFORMER DISC. WARNING HIGH VOLTAGE 0-0V OUT. DISC. SUPVISRY AC GND FLT BATT TRO COM AC INPUT GENERAL 4 REMOVE DISPLAY PLATE FOR PROGRAMMING ACCESS ZE ZE ZE ZE 4 OP - OP - OP - OP4-4V - PUSH TO READ POINT SUPVRY AL PT LOCATOR METER ZE ZE - - 4 SUPVRY. INPUT ZES ZE - - PT PT PT PT 4 SUPERV. - GND BATTERY CABINET MOUNTING - The Battery Cabinet should be mounted directly below the SRP-4x4 Panel. The Battery wiring is classified as Non- Power-Limited. Therefore the wiring must be segregated from Power-Limited wiring with a minimum of two cable entry openings and a /4 spacing between the two conductors. G N L SRP-4X4 FIRE CTROL PANEL ZE 4 L OUT FIRE CTROL PANEL RTN ZE 4 - Batteries are connected to the Fire Control Panel by using 6 AWG wire to the supplied PWSC splicing connector (50740) and passed thru closed nipple rigid metal conduit. CIRCUITS CAUTI DE-ENERGIZE UNIT PRIOR TO SERVICING RESET - Battery wire leads should be color coded with respect to supplied battery wiring of the panel. Caution: Always observe polarity when connecting up batteries. Improper connection will cause the battery fuse to blow. See Page 4 for proper Battery Calculation Sizing. PWSC SPLICING CNECTOR (50740) SRP-4x4 Caution: Batteries contain sulfuric acid which can cause severe burns to the skin and eyes. If contact is made with sulfuric acid, immediately flush skin or eyes with water for 5 minutes and seek immediate medical attention. CLOSED NIPPLE CDUIT CNECTOR 6 AWG WIRE 6 AWG WIRE 6 AWG WIRE - - VOLT BATTERY VOLT BATTERY (BATTERY CABINET E-.5) BATTERY CABINET DIMENSIS 7.00 SEE DETAIL "A" 0.5 0.00.00.50.4 R.87.00 9.50.5.50 DETAIL "A" 8.00.8 PL - Battery Cabinet can be purchased in two colors, red (E-.5) or beige (E-.5B)

SRP-4x4 Fire Alarm Control Panel Typical Panel Wire Routing Detail When bringing field wires to and from the control panel you must maintain segregation between Power Limited and Non-Power Limited wiring. Use the illustration below as a guideline for routing wire within the system enclosure. Also reference the field wiring sections of this manual to determine which field connections are Power Limited and which are Non-Power Limited N-POWER-LIMITED CIRCUITS POWER-LIMITED CIRCUITS TRANSFORMER G N L AC INPUT PUSH TO READ POINT ZE ZE - - ZE ZE 4 - - SUPERV. - CIRCUIT BREAKER WARNING: HIGH VOLTAGE 0-0V ZE 4 AL PT LOCATOR METER L OUT RTN PT PT PT PT 4 OUT. DISC. SUPVISRY AC GND FLT BATT TRO COM GENERAL 4 ZE ZE ZE ZE 4 FIRE CTROL PANEL 4 SUPVRY. INPUT ZES SUPVRY REMOVE DISPLAY PLATE FOR PROGRAMMING ACCESS CAUTI DE-ENERGIZE UNIT PRIOR TO SERVICING RESET - BATTERY CIRCUITS GND DISC. OP - OP - OP - OP4-4V - SRP-4x4 POWER-LIMITED CIRCUITS POWER-LIMITED CIRCUITS BATTERIES: N-POWER-LIMITED CIRCUITS NOTE: ALL N-POWER-LIMITED WIRING MUST BE SEGREGATED FROM POWER-LIMITED WIRING WITH A MINIMUM OF TWO CABLE ENTRY OPENINGS AND /4"SPACING BETWEEN THE TWO CDUCTOR TYPES DRY CTACTS FROM COMM, COMM & RELAY CNECTIS ARE LY CSIDE POWER-LIMITED WHEN CNECTED TO A POWER LIMITED SOURCE

NOTIFICATI APPLIANCE CIRCUIT WIRE SIZE ESTIMATOR To insure that all notification appliance circuits will be supplied with adequate power to operate, it is necessary to use the correct size cable for the distance and current requirements of each circuit. Follow the steps below to calculate the correct wire size for your application. The calculations are based on a maximum line loss (voltage drop) of.0 volts.. Calculate the required alarm device current. (Number of Devices) X (Device Current) = Total Alarm Device Current (AMPS). Determine the wire run distance in feet from the panel to the last alarm device.. Find the load current (AMPS) on Table that best matches the required alarm device current. If the device current is in between two values, use the higher value. 4. Find the wire run distance to the right of the device current value chosen in step which is greater than your requirement. 5. The gauge at the top of the distance column is what will be required to insure a maximum line loss of less than volt, or ohm max. fully loaded. EXAMPLE: If the total alarm device load is.680 AMPS; select.750 AMPS. If the measured distance is 400 feet; select 55 feet which is in the 4 AWG column. TABLE - COPPER WIRE RESISTANCE DEVICE MFGR MODEL AMPS HORNS MOTOR S STROBE HORN/ STROBE TABLE - COMPATIBLE 4VDC POLARIZING SIGNALING DEVICES AMESCO H4W 0.05 HW-4 0.05 WHEELOCK MIZ 0.04 FEDERAL 450 0.5 AMESCO MBA-6-4 0.0 MBA-8-4 0.05 WHEELOCK MB 0.00 AMESCO WHEELOCK SLW4W 0.0 SAD4 0.50 AHWP 0.00 ASWP 0. FEDERAL LP SERIES 0. AMESCO SHW4W 0.088 SHP4 0.50 WHEELOCK NS4 0.6 STROBE/ BUZZER FEDERAL AVST 0.9 AV 0.98 FOR COMPLETE LIST OF NOTIFICATI APPLIANCE DEVICES AND THEIR CORRESPDING CURRENT DRAW SEE APPENDIX A TOTAL DEVICED LOAD (AMPS) AWG = AMERICAN WIRE GAUGE GAUGE (AWG) OHMS PER,000 FT. SINGLE CDUCTOR 0.08.69 4.575 6 4.094 8 6.50 TABLE - INDICATING CIRCUIT WIRE SIZE FOR 4VDC POLARIZING DEVICES FEET OF CDUCTOR WIRE 8 AWG 6 AWG 4 AWG AWG 0 AWG 0.060 560 4070 6470 090 670 0.5 5 950 65 4940 7855 0.50 60 975 550 470 95 0.75 405 650 05 645 65 0.500 05 485 765 5 960 0.65 45 90 60 985 570 0.750 00 5 55 80 05.000 50 40 85 65 980.50 0 95 0 490 785.500 00 60 55 40 650.750 85 5 0 50 560.000 75 0 90 05 490 NOTE: The maximum alarm indicating circuit resistance is calculated for a line loss of volt divided by the maximum alarm device current.

FIELD WIRING SUPERVISED INITIATING DEVICE CIRCUITS CLASS A (NFPA STYLE D) / CLASS B (NFPA STYLE B) Use the following compatible devices approved by The Protectowire Co., Inc. - UP TO 0,000 FEET OF PROTECTOWIRE (May be placed after last detector) - UP TO (5) 0.045mA TWO-WIRE HOCHIKI SMOKE DETECTORS NOTES: Maximum feed cable resistance = 00 OHMS to last smoke detector. Feed cable may consist of any combination of PROTECTOWIRE or copper wire. Hochiki Smoke detectors PRO SERIES #SLR-4 (Photoelectric), #SIJ-4 (Ionization) Detector Identifier - HD- Base Identifier - HB-. Also, #SLR-4H Photo/Heat Smoke Detector Identifier HB-. Per UL 864 9th edition stipulation has been added that two wire smoke detectors of different models are not to be mixed or matched on a system. Note: Power-limited field wiring must be isolated from non-power-limited field wiring. Use 4-8 AWG wire UL Listed for Application. TYPICAL CLASS B DETECTI (NFPA STYLES B) TYPICAL CLASS A DETECTI (NFPA STYLES D) ZB-4-QC-MP ZE BOX PROTECTOWIRE LINE HEAT DETECTOR UP TO ADD'L 9,500 FT. (0,000 FT. TOTAL) ZE BOX (ZB-4-QC-MP) WITH /W SMOKE DET. 00 OHMS MAX. FEED CABLE RESISTANCE TO LAST DETECTOR ZB-4-QC-MP ZE BOX PROTECTOWIRE LINE HEAT DETECTOR UP TO 500 FT. MAXIMUM ZB-4-QC-MP ZE BOX CLASS B SW. CIRCUITS () /W MAXIMUM AMOUNT OF FEED CABLE / PROTECTOWIRE CANNOT EXCEED 00 OHMS WHEN UTILIZING SMOKE DETECTORS PROTECTOWIRE LINE HEAT DETECTOR UP TO 500 FT. SMOKE DET. SPOT HEAT DET. 00 OHMS MAX. FEED CABLE RESISTANCE TO LAST DETECTOR NOTE: POWER LIMITED FIELD WIRING MUST BE ISOLATED FROM N POWER LIMITED FIELD WIRING. ZB-4-QC-MP ZE BOX ZB-4-QC-MP ZE BOX SMOKE DET. ZE ZE ZE 4 SWITCH READ POINT PROTECTOWIRE FEED CABLE ZE () OUT (-) OUT () OUT (-) OUT () OUT (-) OUT () OUT (-) OUT () OUT SWITCH (-) OUT PROTECTOWIRE FEED CABLE READ POINT () OUT () RET. ZE (-) RET. (-) OUT NOTE: UP TO 0,000 FT OF PROTECTOWIRE ZE ZE ZE 4 PER ZE, WHEN NO SMOKE DETECTORS ARE UTILIZED 4 AL PT LOCATOR METER *UPPER RIGHT CORNER OF BOARD L OUT L RTN PT PT PT PT 4 GND 4 AL PT LOCATOR METER *UPPER RIGHT CORNER OF BOARD L OUT L RTN PT PT PT PT 4 GND Note: The panel is supplied with - Ohm Resistors on all Initiating circuits. When wiring detection zone in a Class B configuration, these resistors must be removed and placed at the end of each detection circuit and mounted in a Protectowire Zone Box (ZB-4-QC-MP). See above illustration. ZE BOX ZB-4-QC-MP ZE DESIGNATI: VALUE: DATE: INSTALLER: 4

FIELD WIRING SUPERVISED NOTIFICATI, SOLENOID RELEASE CIRCUITS & N-SUPERVISED AUXILIARY 4V USAGE NOTE: CIRCUIT # USED FOR NOTIFICATI PURPOSES LY WHILE CIRCUITS # thru #4 MAY BE USED FOR EITHER NOTIFICATI AND/OR RELEASING - NOTES: Output circuits OP thru OP4 are all power-limited circuits and must be segregated from non-power-limited circuits with a minimum spacing of two cable entry openings and /4 spacing between the two conductor types. See wire routing detail for layout. To provide proper supervision of solenoid coils, the ELD must be installed in the same junction box as the solenoid. Auxiliary 4 V output is power-limited, with a maximum current draw of 00mA. It is an un-supervised circuit, therefore it can only be used for three purposes per UL 864 requirements. ) As a bell, register or similar indicating device included as part of the control-unit assembly. ) As an alarm bell installed in the same room as the control unit provided the bell circuit conductors are to be installed in conduit or have equivalent protection. ) Or as a supplemental signal annunciator, signal-sounding appliance, motor stop, or similar appliance, provided that neither a short circuit, a break, or a ground fault will not prevent normal operation other than the omission of the supplementary feature. Use 0-4 AWG wire, UL listed for application. 5

PDM-000-4 PROTECTOWIRE POINT LOCATI METER DESCRIPTI: The PDM-000-4 PROTECTOWIRE Digital Alarm Point Location Meter is designed to help locate a heat actuated point on a PROTECTOWIRE line heat detector circuit. This meter identifies the distance in feet or meters (preset at the factory) along the detector from the start of the run to the actuated point. Note: The PDM-000-4 is calibrated at the factory and only requires adjustment to compensate for field cable resistance at the time of installation. OPERATI: When an alarm signal is received at the main control panel, depress the meter switch (see illustration below) of the zone in alarm. The meter will then display the distance to the actuated portion of the PROTECTOWIRE line heat detector circuit. CALIBRATI: The copper feed wire between the control panel and the zone (junction) box at the start of the PROTECTOWIRE run has an inherent resistance. This resistance although small compared to that of the PROTECTOWIRE, will introduce an error in the digital meter reading. The longer the feed wire, the greater the error. Adjust the meter per the following procedure to compensate for field wiring resistance.. Disconnect all alarm and/or releasing devices connected to the control panel and apply power to the system before proceeding.. Connect a jumper wire across the detection circuit at the beginning of the PROTECTOWIRE run (at the zone box). Caution: This will trip the detection circuit into an alarm condition.. At the control panel press the meter read switch for the appropriate zone in alarm. The meter will display the feed cable error. 4. To cancel out (zero) this value, adjust the corresponding PT# potentiometer on the main panel for the zone in alarm by using a small screwdriver to turn the potentiometer until the meter reads zero (see below). Note: the positive () and negative (-) indicator will fluctuate when zeroed. 5. Repeat this procedure for all other zones containing PROTECTOWIRE line heat detector. Note: The PROTECTOWIRE digital meter is designed for reading lengths of PROTECTOWIRE line heat detector cable installed at an ambient temperature of 70º F. Since the inner conductors of PROTECTOWIRE consists of two steel wires, the inherent cable resistance is subject to change proportionally to temperature. For each 0º F change in temperature a % change in total measure cable length can be expected. Using #4 AWG or larger copper feed wire in detection circuits that have PROTECTOWIRE will minimize meter reading error. ZE METER SWITCHES FIELD ADJUSTMENT FOR PWM-D MAIN PANEL (UPPER RIGHT CORNER OF BOARD) PUSH TO READ POINT ZE E - - E Z - - SUPERV. - ZE 4 AL PT LOCATOR METER METER RELAY L OUT METER RELAY METER RELAY METER RELAY L RTN PT PT PT PT 4 GND 6

RB-4 AUXILIARY RELAY MODULE Description - Auxiliary signaling relays are often needed to provide an interface to other systems for annunciation and/or electrical shutdown. The RB-4 Relay Module provides 4 individually zone activated sets of Form C contacts in one module. Operation - The RB-4 relays are normally de-energized. Each relay ( 4) is activated by an alarm of its corresponding input circuit ( 4). Indicators L through L4 (Red) illuminate when the corresponding relay is activated. RB-4 Form C Contacts Electrical DC Contact Rating - AMP @ 4VDC (Resistive) Contact Configuration (4) - SPDT Coil Rating each (4) - 0.0 AMPS @ 4VDC Terminal Wire Capacity - 8-4 AWG Solid/Braid Indicator - Red LED Mounting Diagram FRT VIEW WIRING HARNESS H JP SRP-4x4 SIDE VIEW STANDOFFS 6 PLACES WIRING HARNESS H WIRING HARNESS H JP SRP-4x4 RB-4 7

CLASS A NOTIFICATI APPLIANCE CIRCUIT ADAPTER Description: The AM-9- Alarm Notification Appliance Circuit Adapter Module converts the two Class B system Alarm Notification Appliance Circuits from the Main Board to Class A type circuits. This provides four wire alarm notification appliance circuits in lieu of the standard wire circuits. Operation: The two wire Class B circuits are wired into the module input terminals (TB). The AM-9- then conditions and converts the circuits to four wire Class A alarm notification appliance circuits. This Alarm notification appliance output circuit is fully supervised with the reverse polarity current flow. A short or open in the field wiring is detected by the system controls. Once an alarm is initiated the circuit immediately reverses polarity and the 4V FWR power is supplied to the alarm notification appliance devices. If a single break occurs in the circuit all devices will still be supplied power in an alarm state due to the nature of a Class A wiring configuration. Voltage 4V regulated Full wave rectified (FWR) with battery standby AMPS per circuit. AMPS maximum combined. Current Maximum conductor copper feed cable resistance may not exceed OHM (see below) #0 AWG Maximum of 500 (feet) Reference DS-9066 # AWG Maximum of 00 (feet) Reference DS-9066 #4 AWG Maximum of 00 (feet) Reference DS-9066 AM-9- Class A Alarm Notification Appliance Circuit Adapter Module (-) OUT SUPERVISED CLASS A SIGNAL CIRCUIT # S SUPERVISED CLASS A SIGNAL CIRCUIT # LAST LAST ST ST (-) RETURN () RETURN () OUT (-) OUT (-) RETURN () RETURN () OUT AM-9- SUPERVISED CLASS B TB (SRP-4x4) SIGNALING CIRCUIT # () OP SUPERVISED CLASS B SIGNALING CIRCUIT # (-) () (-) OP Note: Polarity of Notification Appliance Circuits shown in Alarm Condition 8

SRP 4x4 STANDARD RELEASE PANEL INSTALLATI, TESTING & MAINTENANCE Installation & System Power Up.. Carefully unpack system and inspect for any visual damage from shipping. Bench testing of panel for proper operation prior to installation is recommended.. Mount the system in a clean, easily accessible, stable area with four (4 ) /4 screws. The system enclosure should be mounted to allow clear visibility of the systems control indicators and easy access to the systems control switches.. Wire the system according to this manual. Wiring should be in accordance with applicable National and/or Local Electrical and Fire Alarm Codes. Warning: Conduit entry through the electrical enclosure must be made using knockouts provided. When making conduit entries, take preventative measures to ensure metal drill filings and debris does not enter the components of the system. All conduit entries should be sealed to avoid water entering from the conduit system into the system enclosure. Failure to comply with the above will void the factory warranty. Special Note: All supervised circuits are conditioned at the factory with an end-of-line resistor (-) or dummy load resistor across the circuit field terminals. The end-of-line resistors must be removed when field wiring is connected to the circuit terminations. Class B supervised circuits require the to be connected at or after the last device on the circuit. Class A supervised circuits do not require an. Output Circuits are conditioned with a dummy resistor across the field connections when shipped from factory. The resistor must be removed when field wiring is connected at the field terminals. Refer to field wiring diagram for proper selection and installation of end-of-line devices. 4. Slide Output Disconnect Switch to the left (disconnect) position to prevent accidental activation of output circuits - 4. Note that Output is NOT disconnected through this switch. Disconnect Output by removing field wiring. 5. Connect AC power according to the systems rating as identified on the model ID tag mounted on the inside of the enclosure door. a) Load connection AC INPUT TB Terminal L b) Neutral connection AC INPUT TB Terminal N c) Ground connection AC INPUT TB Terminal G 6. When applying power to systems with output circuits disconnected; the system will be in a trouble condition due to the disconnection of the output circuits in step 4. Silence the system by pressing the System Silence button. 7. Disconnect dummy battery load.k resistor from the system battery connectors and connect standby batteries. Allow 48 hours for batteries to charge to full capacity. 8. Verify that no trouble indicators are illuminated except under the following conditions. The disconnect switch is in the left (disconnect) position and the OUT. DISC. SUPVISRY indicator is illuminated. The batteries connected to the system are not pre-charged and the BATT TRO indicator is illuminated. If any other trouble lights are illuminated determine the problem with those circuits using the troubleshooting guide in this manual and repair them before continuing. 9. Only after the system has been cleared from any erroneous alarm or trouble signals, bring the disconnected output circuits on line by sliding the Output Disconnect Switch to the right (connected) position. The AC indicator should be the only system indicator illuminated. 0. Test the system per the Test and Maintenance procedure in this manual. 9

SRP 4x4 STANDARD RELEASE PANEL INSTALLATI, TESTING & MAINTENANCE Testing and Maintenance Quarterly testing is advised to help insure system controls are functioning properly. Testing should be performed by competent personnel having jurisdiction over the protective signaling system. The following instructions should be observed in conjunction with the System Operational Outline contained in this manual when testing this equipment. Testing Note:. Notify the applicable local fire department and/or alarm receiving station.. Inform all personnel in the facility that testing is in progress, start of testing to finish.. Disconnect any and all auxiliary alarm devices (solenoids, system shutdowns, etc.). 4. TEST, slide Output Circuit Disconnect switch to left (disconnect) position to prevent accidental activation of output circuits,, & 4. Place a jumper across each detection/initiating circuits field terminations. 5. Press the System Reset button located on the control panel to return to standby condition. 6. SUPERVISI TEST, Open supervised circuits (Detection, Switch Supervisory, Alarm Notification Appliance Circuits, Solenoid, Waterflow Detection, etc.) by removing one wire lead from the field terminal for each individual circuit one at a time. Replace each wire before moving on to the next circuit. Momentarily short each output circuit with jumper wire to verify trouble condition. Remove short prior to testing next circuit. The following LED indications will occur in addition to the system ground fault trouble when the respective circuit is connected to earth ground with a resistance up to.k ohms. a) The indicator will illuminate if the positive or negative leg of a detection circuit is connected to the earth ground. b) The Output Circuits respective indicator along with the indicator will illuminate if the positive leg of the circuit is connected to earth ground. Only the indicator will illuminate if the negative leg of the circuit is connected to earth ground. c) The indicator will illuminate if the positive or negative leg of the Switch Supervisory Circuit is connected to earth ground. These indications are an adverse effect caused by ground faults but can prove useful in identifying the location of a ground fault when they occur. WARNING FATAL ELECTRIC SHOCK AND EQUIPMENT DAMAGE MAY RESULT FROM FAILURE TO REMOVE AND LOCK OUT ALL POWER PRIOR TO SERVICING 0

SRP 4x4 STANDARD RELEASE PANEL INSTALLATI, TESTING & MAINTENANCE Operational Outline:. Normal Standby Condition a) AC Indicator (Green) illuminated.. Power Supervision AC power source failure: a) AC Indicator (Green) OFF. b) System trouble buzzer - Press button to silence. c) Indicator (Yellow). d) Restore AC power to resume standby condition. DC power source failure: a) Indicator (Yellow). b) BATT TRO Indicator (Yellow). c) System trouble buzzer - Press button to silence. d) Restore DC power to resume standby condition.. Initiating Device Circuits (Input) Short in detection loop/device = Alarm Condition: a) ZE Indicator (Red). b) Respective Indicator (Red) (Reflects panel operation logic). c) Respective Output Circuits activated - Press button to silence, indicator (Yellow). d) Restore Detection Circuit or Initiating Device. Press RESET button to return to standby condition. Open in Detection Loop - Zone Trouble/System Trouble: a) Indicator (Yellow). b) ZE Indicator (Yellow). c) System trouble buzzer - Press button to silence. d) Clear Detection Circuit to return to standby condition. 4. Output Circuits Short in Output Circuit loop: a) Indicator (Yellow). b) Respective Indicator (Yellow). c) System trouble buzzer - Press button to silence. d) Clear (repair) short in circuit to return to standby condition. Open in Circuit loop: a) Indicator (Yellow). b) Respective Indicator (Yellow). c) System trouble buzzer - Press button to silence. d) Clear (repair) short in circuit to return to standby condition. 5. Switch Supervisory Zone Short in Switch Supervisory Circuit - Supervisory Alarm: a) Indicator (Yellow). b) System trouble buzzer - Press button to silence. c) Restore Supervisory Circuit or initiating device. Press RESET button to return to standby condition.

SRP 4x4 STANDARD RELEASE PANEL INSTALLATI, TESTING & MAINTENANCE Operational Outline Continued: 5. Switch Supervisory Zone Continued Open in Switch Supervisory Circuit - Supervisory Trouble/System Trouble: a) Indicator (Yellow). b) Indicator (Yellow). c) System trouble buzzer - Press button to silence. d) Repair Open to return to standby condition. 6. Ground Fault Detection Circuit When undesirable current flows to ground from the system DC power supply, either positive or negative: a) Indicator (Yellow). b) GND FLT Indicator (Yellow). c) System trouble buzzer - Press button to silence. d) Repair Ground Fault and allow 5 seconds for system to restore to standby condition. 7. Output Disconnect Supervisory - Slide Output disconnect switch to the left position. a) OUT. DISC. SUPVISRY Indicator (Yellow). b) System trouble buzzer - Press button to silence. c) Restore switch to normal right position to clear.

SRP 4x4 STANDARD RELEASE PANEL SHOOTING Primary BASIC SHOOTING GUIDE FOR THE SRP 4x4 STANDARD RELEASE PANEL INDICATOR STATUS AC Indicator OUT SYS. TRO. Indicator Trouble buzzer FAULT CDITI AC Power source failure COURSE OF ACTI Check AC power source connections & voltage. Reset Circuit breaker CB. ALTERNATE ACTI Check secondary voltage from transformer across st two pins of JP = 0V approx. Standby Power Output Circuits AC Indicator SYS. TRO. Indicator BATT. TRO Indicator Trouble Buzzer AC Indicator SYS. TRO. Indicator BATT. TRO Indicator Trouble Buzzer AC Indicator SYS. TRO. Indicator Respective Trouble Indicator Trouble Buzzer Backup Power source failure Batteries disconnected or overcharged Backup Power source failure Batteries undercharged or drained below acceptable voltage level. Output Circuit fault. A short or an open exists in the Output Circuit field wiring. Check battery connections Check battery fuse F Check the battery voltage and be sure to allow at least 48 hours for charging of new or drained battery sets. If batteries do not charge replace them. Remove the Output Circuit field wiring from the field terminals and replace with an end-of-line resistor - ohm. If the condition clears the fault is in the field wiring. Find and replace short, or repair open. Check battery voltage with charger connected. Voltage should read between 6-8 volts. Replace batteries if needed. If condition still exists, consult factory. If condition still exists, consult factory. Ground Fault AC Indicator SYS. TRO. Indicator GND FLT Indicator Trouble Buzzer A ground fault exists. Either a Positive or Negative connection exists to the earth ground in the system or its field wiring. All field wiring must be tagged and removed from the field terminals until the condition clears or all wiring has been isolated. If condition clears after removing a field wire, the fault/s exist in that wire. Repair fault and reconnect all field wiring. If after all field wiring is isolated from the panel the condition still exists, consult factory. Detection Circuits AC Indicator SYS. TRO. Indicator ZE TRO. Indicator Trouble Buzzer (includes detection, waterflow, and switch supervisory zones) Open in zone circuit field wiring. Class B - Remove the Zone Circuit field wiring from the field terminals and replace with an end-ofline resistor - ohm across the () and (-) out terminals. Class A - Place jumpers across the field terminals in a Class A configuration. If the condition clears the fault is in the field wiring. Find and repair open. If the circuit does not clear when conditioned as stated previously, consult the factory.

SRP 4x4 STANDARD RELEASE PANEL SHOOTING CTINUED Detection Circuits BASIC SHOOTING GUIDE FOR THE SRP 4x4 STANDARD RELEASE PANEL INDICATOR STATUS AC Indicator SYS. Indicator Zone Indicator FAULT CDITI Short in zone circuit field wiring or initiating device in alarm, i.e. Smoke detector, Linear heat detector, etc. COURSE OF ACTI Class B - Remove the zone circuit field wiring from the field terminals and replace with an end-ofline resistor - ohm across the () and (-) out terminals. Class A - Place jumpers across the field terminals in a Class A configuration. Depress the RESET button. If the condition clears fault is in the field wiring. Find and repair short of initiating device. ALTERNATE ACTI If the circuit does not clear when conditioned as stated previously, consult the factory. 4

5 5 TRANSFORMER YEL. ORG. WIRING DIAGRAM PROGRAM # SINGLE RELEASE, THREE ZES WITH E WATERFLOW ZE AND ZE WITH / CIRCUIT LOW WHT. BLK. EARTH GROUND - GREEN NEUTRAL - WHITE LOAD - PROTECTOWIRE LINEAR HEAT DETECTOR WHEN CNECTING SMOKE DETECTORS M WF MANUAL STATI M WATER FLOW SW. AIR & VALVE TAMPER SW. LA VT LOOP RETURN WIRING CIRCUIT BREAKER G N L WARNING: HIGH VOLTAGE: 0-0V AC INPUT BUZZER PUSH TO READ POINT ZE 4 ZE ZE ZE ZE 4 OUT. DISC. SUPVISRY AC GND FLT BATT TBL ZE ZE ZE ZE 4 4 FIRE CTROL PANEL 4 SUP. INPUT ZES COM SUPVRY DS DS DS OFF OFF OFF TYPICAL CLASS A WIRING NOT USED IN CLASS A CIRCUIT 4 4 5 4 SEE NOTE BELOW SIGNAL RESET BATTERY PROGRAMMING ACCESS SIGNALING CIRCUITS OP - OP OP OP4 REMOTE SIGNALING RELAY S S OP,&4 DISC. 4V - GND S CDITI PANEL PROBLEM LOSS OF AC LOSS OF BATTERY WIRING PROBLEM CDITI HEAT DET. SMOKE DET. PULL STATI WATERFLOW LOW AIR VALVE TAMPER - V BATT. V BATT. GENERAL ELD ASSY RELEASE SOLENOID CIRCUIT WATER FLOW SUPV./ Description: Single release - three zone Inputs: () IDC zones, () manual pull zone, () waterflow zone, () supervisory zone. Outputs: () general alarm bell, () solenoid release, () waterflow bell, () supervisory bell. Operation: Activation of either IDC zone or manual pull zone will operate the release circuit and general alarm output circuit. Activation of the waterflow zone will operate the waterflow bell output circuit. Activation of the supervisory zone will operate the supvry./trouble bell #4 output circuit. A trouble condition (low/disc. battery,wire problem, etc.) will operate the supv./trouble bell. When either Zone, or is in alarm - Output # (general alarm) and Output # (solenoid release) will operate. When Zone 4 is in alarm - Output # will operate the waterflow bell circuit. When the supervisory zone is activated - Output #4 will operate supervisory bell only. Note: DS SW5 & 8 placed to the "" position for Output #4 to activate on either supervisory or trouble signals. Supervisory bell must provide a distinct sound which is different than alarm bells. revised --008 5

5 5 WIRING DIAGRAM PROGRAM # SINGLE RELEASE, TWO ZES (CROSS-ZED), E MANUAL PULL STATI ZE, E WATERFLOW ZE AND E ZE WITH / CIRCUIT TRANSFORMER YEL. ORG. WHT. BLK. EARTH GROUND - GREEN NEUTRAL - WHITE LOAD - PROTECTOWIRE LINEAR HEAT DETECTOR WHEN CNECTING SMOKE DETECTORS ZES & CROSS-ZED M WF MANUAL STATI M WATER FLOW SW. LOW AIR & VALVE TAMPER SW. LA VT LOOP RETURN WIRING CIRCUIT BREAKER G N L AC INPUT PUSH TO READ POINT WARNING: HIGH VOLTAGE 0-0V ZE 4 BUZZER OUT. DISC. SUPVISRY ZE AC ZE GND FLT ZE BATT TBL ZE 4 4 COM SUPVRY DS DS DS OFF OFF OFF FIRE CTROL PANEL ZE ZE ZE ZE 4 SUP. 4 INPUT ZES TYPICAL CLASS A WIRING NOT USED IN CLASS A CIRCUIT BATTERY S OP,&4 DISC. 4 4 5 4 PROGRAMMING ACCESS SIGNALING CIRCUITS OP - OP S OP OP4 RESET 4V - CDITI PANEL PROBLEM LOSS OF AC LOSS OF BATTERY WIRING PROBLEM SEE NOTE BELOW REMOTE SIGNALING RELAY S CDITI HEAT DET. SMOKE DET. PULL STATI WATERFLOW GND LOW AIR VALVE TAMPER Note: Multiple detector applications require min. of detectors in each protected space with reduced linear spacing of 0.7 times listed linear spacing in accordance to NFPA 7 - V BATT. V BATT. GENERAL ELD ASSY RELEASE SOLENOID CIRCUIT WATER FLOW SUPV./ Description: Single release, cross-zoned with manual station override. Inputs: () IDC zones (cross-zoned), () manual pull zone, () waterflow zone, () supervisory zone Outputs: () general alarm bell ckt, () solenoid release, () waterflow bell, () supervisory/trouble bell ckt. Operation: Activation of both IDC zones at the same time, or activation of the manual pull zone will operate the release output and the general alarm output circuit. Activation of one IDC zone will operate the general alarm output. Activation of the waterflow zone will operate the waterflow bell output circuit. Activation of the supervisory zone will operate the supervisory/trouble bell output circuit. A trouble condition (low/disc. battery, wire problem, etc.) will operate the supv./tro. bell. When Zone, or is in alarm - Output # will operate (general alarm bell). When Zone is in alarm - Outputs # (solenoid release) and # (general alarm) will operate. When Zones and are in alarm at the same time - Output # will operate (solenoid release). When Zone 4 is in alarm - Output # will operate the waterflow bell circuit. When the supervisory zone is activated - Output #4 will operate the supervisory only bell. Note: DS, SW5 & 8 placed to the "" position for Output #4 to activate on either supervisory or trouble signals. Supervisory bell must provide a distinct sound which is different than Alarm bell. revised --008 6

5 5 WIRING DIAGRAM PROGRAM # DUAL COMBINED RELEASE, TWO ZES, E MANUAL STATI ZE, E WATERFLOW ZE, AND E ZE WITH / CIRCUIT PROTECTOWIRE LINEAR HEAT DETECTOR MANUAL STATI WATER FLOW SW. LOW AIR & VALVE TAMPER SW. TRANSFORMER YEL. WHT. ORG. BLK. EARTH GROUND - GREEN NEUTRAL - WHITE LOAD - WHEN CNECTING SMOKE DETECTORS M WF M LA VT LOOP RETURN WIRING CIRCUIT BREAKER G N L WARNING: HIGH VOLTAGE: 0-0V AC INPUT BUZZER PUSH TO READ POINT ZE 4 ZE ZE ZE ZE 4 OUT. DISC. SUPVSRY ZE AC ZE GND FLT ZE BATT TBL ZE 4 4 COM SUPVRY DS DS DS OFF OFF OFF FIRE CTROL PANEL 4 SUP INPUT ZES TYPICAL CLASS A WIRING NOT USED IN CLASS A CIRCUIT 4 4 5 4 SEE NOTE BELOW SIGNAL RESET BATTERY PROGRAMMING ACCESS SIGNALING CIRCUITS OP - OP OP OP4 REMOTE SIGNALING RELAY S S OP,&4 DISC. 4V - GND S S CDITI PANEL PROBLEM LOSS OF AC LOSS OF BATTERY WIRING PROBLEM CDITI HEAT DET. SMOKE DET. PULL STATI WATERFLOW LOW AIR VALVE TAMPER - V BATT. V BATT. GENERAL ELD ASSY ELD ASSY RELEASE RELEASE SOLENOID SOLENOID CIRCUIT CIRCUIT SUPV./ Description: Dual combined release - three zones Inputs: () IDC zones, () manual pull zone, () waterflow zone, () supervisory zone Outputs: () general alarm bell ckt, () solenoid release ckts, () supervisory trouble bell ckt. Operation: Activation of either IDC zone or manual pull zone will operate both solenoid release outputs and the general alarm output bell. Activation of the waterflow zone will operate the general alarm bell. Activation of the supervisory zone will operate the supervisory/trouble bell output circuit. A trouble condition (low/disc. battery, wire problem etc.) will operate the supv./tro. bell. When either Zone, or is in alarm - Output # (general alarm) and outputs # and # (solenoid release) will operate. When Zone 4 is in alarm - Output # (general alarm) will operate. When the supervisory zone is activated - Output #4 will operate supervisory only bell. Note: DS, SW5 & 8 placed to the "" position for Output #4 to activate on either supervisory or trouble signals. Supervisory bell must provide a distinct sound which is different than alarm bell. revised --008 7

5 WIRING DIAGRAM PROGRAM #4 DUAL SPLIT RELEASE, TWO (IDC) ZES, E WATERFLOW ZE, AND TWO ZES WITH / CIRCUIT WATER FLOW SW. SUPV. SUPV. LOW AIR & VALVE TAMPER SW. PROTECTOWIRE LINEAR HEAT DETECTOR TRANSFORMER YEL. WHT. ORG. BLK. EARTH GROUND - GREEN NEUTRAL - WHITE LOAD - MANUAL STATI WHEN CNECTING SMOKE DETECTORS M M WF S S LA VT LOOP RETURN WIRING CIRCUIT BREAKER G N L WARNING: HIGH VOLTAGE: 0-0V OUT. DISC. SUPVISRY AC GND FLT BATT TBL COM AC INPUT BUZZER ZE 4 4 PUSH TO READ POINT ZE ZE ZE ZE SUP DS DS DS OFF OFF OFF 4 FIRE CTROL PANEL ZE ZE ZE ZE 4 4 SUP INPUT ZES TYPICAL CLASS A WIRING NOT USED IN CLASS A CIRCUIT 4 4 5 5 4 SEE NOTE BELOW SIGNAL RESET BATTERY PROGRAMMING ACCESS SIGNALING CIRCUITS OP- OP OP OP4 REMOTE SIGNALING RELAY S S OP,&4 DISC. 4V - GND S S CDITI PANEL PROBLEM LOSS OF AC LOSS OF BATTERY WIRING PROBLEM CDITI HEAT DET. SMOKE DET. PULL STATI WATERFLOW LOW AIR VALVE TAMPER - V BATT. V BATT. GENERAL ELD ASSY ELD ASSY RELEASE RELEASE SOLENOID SOLENOID # CIRCUIT # CIRCUIT SUPV./ Description: Dual split release - two zones Inputs: () IDC zones, () waterflow zone, () supervisory zones Outputs: () general alarm bell ckt, () solenoid release ckts, () supervisory/trouble bell ckt. Operation: Activation of IDC Zone # will operate solenoid release # (Output #) and the general alarm bell. Activation of IDC Zone # will operate solenoid release # (Output #) and the general alarm bell. Activation of the waterflow zone will operate the general alarm bell. Activation of either supervisory zone will operate the supervisory/trouble bell. A trouble condition (low/disc. battery,wire problem etc.) will operate the supv./tro. bell. When Zone is in alarm - Output # (general alarm) and Output # (solenoid #) will operate. When Zone is in alarm - Output # (general alarm) and Output # (solenoid #) will operate. When Zone is in alarm (waterflow) - Output # (general alarm) will operate. When either Zone 4 or the supervisory zone are activated - Output #4 (supv.) will operate. Note: DS, SW5 & 8 placed to the "" position for Output #4 to activate on either supervisory or trouble signals. Supervisory bell must provide a distinct sound which is different than alarm bell. revised --008 8

5 5 WIRING DIAGRAM PROGRAM #5 SINGLE RELEASE WITH - TWO ZES, MANUAL PULL STATI ZE, E WATERFLOW ZE, AND E ZE MANUAL STATI LOW WATER FLOW SW. AIR & VALVE TAMPER SW. PROTECTOWIRE LINEAR HEAT DETECTOR TRANSFORMER YEL. WHT. ORG. BLK. EARTH GROUND - GREEN NEUTRAL - WHITE LOAD - WHEN CNECTING SMOKE DETECTORS M WF M LA VT LOOP RETURN WIRING CIRCUIT BREAKER G N L WARNING: HIGH VOLTAGE: 0-0V AC INPUT BUZZER PUSH TO READ POINT ZE 4 ZE ZE ZE ZE 4 OUT. DISC. SUPVISRY AC GND FLT BATT TRO COM ZE 4 4 ZE ZE ZE SUP DS DS DS OFF OFF OFF FIRE CTROL PANEL 4 SUP INPUT ZES TYPICAL CLASS A WIRING NOT USED IN CLASS A CIRCUIT 4 4 5 4 SIGNAL RESET BATTERY PROGRAMMING ACCESS SIGNALING CIRCUITS OP- OP OP OP4 REMOTE SIGNALING RELAY S S OP,&4 DISC. 4V - GND S CDITI PANEL PROBLEM LOSS OF AC LOSS OF BATTERY WIRING PROBLEM CDITI HEAT DET. SMOKE DET. PULL STATI WATERFLOW LOW AIR VALVE TAMPER DISC SWITCH - V BATT. V BATT. GENERAL ELD ASSY RELEASE SOLENOID CIRCUIT SUPV. Description: Single release - three zone with trouble bell. Inputs: () IDC zones, () manual pull zone, () waterflow zone, () supervisory zone Outputs: () general alarm bell ckt, () solenoid release ckt, () supervisory bell ckt, () trouble bell ckt. Operation: Activation of either IDC zone or manual pull zone will operate the release circuit and general alarm output bell. Activation of the waterflow zone will operate the general alarm bell. Activation of the supervisory zone will operate the supervisory bell. A trouble condition (low/disc. battery, wire problem, etc.) will operate the trouble bell. When either Zone, or is in alarm - Output # (general alarm) and Output # (solenoid release) will operate. When Zone 4 is in alarm - Output # will operate the general alarm bell. When the supervisory zone is activated - Output # (supervisory bell) will operate. When the panel is in trouble condition - Output #4 (trouble bell) will operate. Note: Output # Alarm & Trouble indicator will activate when disconnect switch is thrown. Supervisory bell must provide a distinct sound which is different than alarm bell. revised --008 9

WIRING DIAGRAM PROGRAM #6 SINGLE RELEASE, TWO (IDC) ZES, WITH E WATERFLOW ZE AND TWO ZES WITH / CIRCUIT WATER FLOW SW. SUPV. LOW AIR SUPV. VALVE TAMPER SW. PROTECTOWIRE LINEAR HEAT DETECTOR TRANSFORMER YEL. WHT. ORG. BLK. EARTH GROUND - GREEN NEUTRAL - WHITE LOAD - MANUAL STATI WHEN CNECTING SMOKE DETECTORS M M WF LA VT LOOP RETURN WIRING CIRCUIT BREAKER G N L WARNING: HIGH VOLTAGE: 0-0V OUT. DISC. SUPVISRY AC GND FLT BATT TBL COM AC INPUT BUZZER ZE 4 4 PUSH TO READ POINT ZE ZE ZE ZE SUP DS DS DS OFF OFF OFF 4 FIRE CTROL PANEL ZE ZE ZE ZE 4 4 SUP INPUT ZES TYPICAL CLASS A WIRING NOT USED IN CLASS A CIRCUIT 4 5 5 4 5 4 SEE NOTE BELOW SIGNAL RESET BATTERY PROGRAMMING ACCESS SIGNALING CIRCUITS OP- OP OP OP4 REMOTE SIGNALING RELAY S S OP,&4 DISC. 4V- GND S CDITI PANEL PROBLEM LOSS OF AC LOSS OF BATTERY WIRING PROBLEM CDITI HEAT DET. SMOKE DET. PULL STATI WATERFLOW LOW AIR VALVE TAMPER - V BATT. V BATT. GENERAL ELD ASSY RELEASE SOLENOID # CIRCUIT WATER FLOW SUPV./ Description: Single release - two zones / supervisory. Inputs: () IDC zones, () waterflow zone, () supervisory zones. Outputs: () general alarm bell, () solenoid release ckt, () waterflow bell, () supervisory/trouble bell ckt. Operation: Activation of either IDC zone will operate the solenoid release and the general alarm bell. Activation of the waterflow zone will operate the waterflow bell. Activation of either the low air zone or the supervisory zone will operate the supv./tro. bell. A trouble condition (low/disc. battery, wire problem etc.) will operate the supv./tro. bell. When either Zone or is in alarm - Output # (general alarm) and Outputs # (solenoid #) will operate. When Zone is in alarm - Output # (waterflow bell) will operate. When either Zone 4 or the supervisory zone are activated - Output #4 (supv. only) will operate. Note: DS, SW5 & 8 placed to the "" position for Output #4 to activate on either supervisory or trouble signals. Supervisory bell must provide a distinct sound revised --008 which is different than alarm bell. 0