Fire Control Panels. Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control

Similar documents
Fire Control Panels. Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control

Specification/ Data Sheet

Release Control Fire Alarm Systems

Z-20 Fire Control Panels

TrueAlert Addressable Notification Appliances

TrueAlert Notification Appliances

LifeAlarm Fire Alarm Controls

Releasing System Peripherals

TrueAlarm Analog Sensing

TrueAlert Addressable Notification Appliances

TrueAlert ES Addressable Notification Appliances

TrueAlert Addressable Notification Appliances

TrueAlert Multi-Candela Notification Appliances

TrueAlert Addressable Notification Appliances

TrueAlert Multi-Candela Notification Appliances

LifeAlarm Fire Alarm Control Panels

TrueAlarm Analog Sensing

Doc. No Part No Rev. U * T*

TECHNICAL DATA OBSOLETE

Multi-Point Peripherals

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

Multi-Point Peripherals

TrueAlarm ES Analog Sensing

System Accessories, LCD Annunciators

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Conventional Releasing Control Panel

TrueAlert Addressable Notification

4100U City and Relay Cards Installation Instructions

4007ES Fire Control Panels

TrueAlarm Fire Alarm Controls

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi 50 CONTROL PANEL

Booster Power Supply Manual

AND ARCHITECT SPECIFICATIONS

TrueAlarm Addressable Fire Alarm Control Panels

FireFlex DUAL Double Interlock, Self-contained system

TrueAlarm Analog Sensing

Commercial and Light Industrial Fire Alarm Control Panel

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions

Panel Remote Annunciators Installation Instructions

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description.

PFC-7500/PFC-7501 Installation Manual

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features

30.45 Electric Release PDRP-2001

IDNet and MAPNET II Addressable Devices

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE CHEETAH Xi 50 CONTROL PANEL SYSTEM

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

PSN-1000 & PSN 1000(E) Installation Manual

4007ES Fire Control Panels

SLVMC - Oncology & Infusion Remodel & Add 17D /4/2017

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM

MR-2602 Two Zone Fire Alarm Control Panel

Installation Guide. XR5FC and XR5SL

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

Remote Booster Power Supplies

An introduction to... Sigma

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

ADDENDUM to IFC-640 for Factory Mutual Applications

July 14, 1999 DF C-100.

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

Multi-Application Peripherals and Accessories

4007ES Fire Control Panels

as required for residential sprinklers intended for use in dry pipe systems.

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

TrueAlarm Smoke Detectors

Signature Series Auto-Sync Output Module (CC1S)

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPUSLE VALVE, Fike FK AGENT & SHP PRO CONTROL PANEL

AL800ULADA. NAC Power Extender. Installation Guide

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

SECTION TOTAL FLOODING ECARO-25 CLEAN AGENT FIRE EXTINGUISHING SYSTEM

Multi-Application Peripherals

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

/9308 External Battery Chargers Installation Instructions

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

DCP-FRCME - FAST RESPONSE CONTACT MODULE

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPULSE VALVE, FK AGENT & CHEETAH Xi CONTROL PANEL

AL600ULADA. NAC Power Extender. Installation Guide

SIGA-CC1 Single Input Signal Module Installation Sheet

INSPECTION AND TESTING FORM

Fire Alarm System Accessories

Network Display Unit Installation Instructions

N2 BLAST Datasheet SUREFIRE double interlock c/w N 2 Blast Nitrogen generating system Self contained unit

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

June 10, 2002 DF C S2424

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

EST2. Life Safety Systems Control Panels. Analog Control Panel. Standard Features. Overview

/5121/5122 TrueAlert Power Supply Installation Instructions

FIRE ALARM SYSTEM INSPECTION

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT

The TC-4F. Time Control Module C P/N 15972:C ECN For the Sensican 2000 Fire Alarm Control Panel

Addressable Fire Alarm Control Panel

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPULSE VALVE, FK AGENT & CHEETAH Xi 50 CONTROL PANEL

Transcription:

MANUAL RELEAE - IDNET IN + +IDNET IN - R E D N A C + N A C - C O IL U P E R V I IO N MOD U L E ( 2 A MP ) 2 8-9 4 6 IN T A L L A T ION IN T R U C T ION 5 7 4-4 3 7 R E V Y E L MA IN T A IN /4 " E P A R A T ION B E T W E E N P O W E R L IMIT E D ( R E D / ) A N D N ON P O W E R L IMIT E D ( Y E L / ) W IR IN G D A T E C O D E : 5 9-9 5 8 NORMAL IM P L E X T IM E R E C O R D E R C O.G A R D N E R M A.U A CAUTION: This Control Unit has been arranged for releasing service. Disable all releasing device circuits prior to servicing. Fire Control Panels UL, ULC, CFM Listed; FM Approved MEA (NYC) Acceptance* Features Releasing control using the implex 4E (or 4U) Fire Alarm Control Panel to provide**: Coverage for multiple areas of Automatic Extinguishing Release and/or Deluge and Preaction prinkler ystem Release including audible escalation of events Control of compatible Listed/Approved 24 VDC automatic control actuators, one per circuit; or two 2 VDC actuators in series per circuit Releasing appliance circuits (RACs) by connecting Notification appliance circuits (NACs) to uppression Release Peripherals for actuator supervision and control Audible Escalation of Events: Temporal or 2 bpm March Time pattern for first cross-zone alarm 2 bpm March Time pattern to indicate releasing timer active On steady to indicate releasing timer expired and actuator is activated NOTE: Requires NACs dedicated to conventional horn control (not martync operation) with strobes controlled on separate NACs 49-95/-96 uppression Release Peripheral (RP) with Dual Command Control: Dual command control requires that both IDNet communications commands and an activated NAC are present to initiate the desired release NAC provides wiring supervision to the actuator including monitoring of coil continuity and short circuit supervision to the coil supervision module uppression Release Peripheral control features: An on-board DC-DC regulator compensates for voltage drops to the peripheral and ensures proper control circuit voltage over a wide operating range Provides a single RAC for control of actuators for up to 2 A using a 3 A NAC input ( A using a 2 A NAC input) Related system components: 4E eries control panel with Releasing Appliqué Dedicated NAC output from 4E (or compatible NAC Extender) Coil supervision module, one per RAC Maintenance witch, one per RAC Abort witch connected via an addressable interface module UL listed to tandard 864 * This product has been approved by the California tate Fire Marshal (CFM) pursuant to ection 344. of the California Health and afety Code. ee CFM Listings 765-26:25 and 73-26:33 (RP) for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Additional listings may be applicable; contact your local implex product supplier for the latest status. Listings and approvals under implex Time Recorder Co. are the property of Tyco afety Products Westminster. Automatic Extinguishing, Deluge and Preaction prinkler ystem Releasing Control Actuator Control Circuit Agent source Maintenance Disconnect witch (with indicator lamp) uppression Release Peripheral Typical addressable initiating devices Actuator FIRE RELEAING DEVICE Agent discharge path Coil supervisory module UPPREION RELEAE PANEL Release appliance circuit 4E Control Panel with uppression Release Appliqué Power for indicator lamp (if required) IDNet communications Dedicated NAC circuit 4E eries Releasing Control Typical Block Diagram Introduction When combined with uppression Release Peripherals, the 4E series fire alarm control panel provides actuator supervision and control for use in automatic extinguishing, and deluge or preaction releasing systems. Hazard area initiating and notification devices are controlled using either conventional or addressable circuits per standard 4E capabilities. The necessary releasing system logic is implemented within the 4E control panel as required for the local application. ** Release Control operation described in this document is also available with 4U Control Panels with software revision.5 or higher. Refer to data sheet 4-3 for model 4E control panel details including IDNet communications information. 4-4-5

Automatic Extinguishing Release ystems These systems automatically activate electrically controlled actuators for the release of a fire extinguishing agent (such as dry chemical, water spray, foam, CO 2, or clean agent) in response to fire detection device inputs as determined by programming of the host fire alarm control panel. Automatic Extinguishing Release ystem Panels are required to have a minimum of 24 hours of standby power. Initiating devices must be Listed/Approved for the application, and may be wired either Class A or B. Control actuators must be electrically compatible with the control panel circuits and power supplies, and are wired Class B to provide coil supervision. Deluge or Preaction prinkler ystems These systems automatically activate water control actuators in response to fire detection device inputs. Deluge prinkler ystems employ open sprinkler heads and provide water flow when the fire detection system activates a common automatic water control actuator. They are used to deliver water simultaneously through all of the system sprinkler heads. This type of system is applicable where the immediate application of large quantities of water over large areas is the proper fire response. Preaction prinkler ystems are similar to deluge systems except that normally closed sprinkler heads are used and supervisory air pressure is maintained in the pipe. Operation requires both an activated sprinkler head and an activated fire alarm initiating device with specific programming determined at the host fire alarm control panel. Releasing ystem Requirements. Releasing actuators are controlled from a uppression Release Peripheral (49-95 or 49-96). Connections are 2-wire, Class B releasing circuits with only one 24 VDC actuator per circuit. Where applicable, two, 2 VDC actuators in series, or one 2 VDC actuator with manufacturer supplied resistor may be used. 2. Coil upervision Module 28-946 must be wired electrically before the actuator and located in the actuator wiring junction box. (Refer to diagram on page 5.) The connected RAC provides continuity supervision of the actuator coil and wiring and provides short circuit supervision to the coil supervision module. 3. Cross-zoning or other alarm initiation logic per system requirements, is to be implemented by programming at the fire alarm control panel. 4. UL Listed Automatic Extinguishing Releasing operation requires that: battery standby must be a minimum of 24 hours with 5 minutes of alarm and that listed actuators are used, refer to list on page 6. Releasing ystem Requirements (Continued) 5. FM Approved Automatic Extinguishing Release requires secondary standby to be a minimum of 24 hours with 5 minutes of alarm. Actuators must be electrically compatible. 6. FM Approved Deluge and Preaction prinkler operation requires that: initiating device circuits be Class A and wired to Listed/Approved devices; standby power capacity must be a minimum of 9 hours with minutes of alarm; and that compatible Automatic Water Control Valves must be used. (Refer to actuator list on page 7.) 7. Maintenance witches, one per RAC, are required per NFPA 72, the National Fire Alarm Code (22 Edition, Chapter 6) to allow the system to be tested or serviced without actuating the fire suppression systems. Their use may not be allowed in some jurisdictions, always confirm local requirements. When used, implex Maintenance witches are required to ensure that operation initiates a supervisory condition. 8. Abort witches are available when abort operation is required. When used, connect to an addressable upervised IAM model 49-9 or similar addressable adapter module. The implex abort switch and the IAM mount in a single gang box, 2-/2 minimum depth. 9. Addressable Manual Releasing tations are used to initiate activation of the releasing actuators with the appropriate time delay implemented by the fire alarm control panel.. Notification Requirements. Each hazard area typically requires general audible and visible fire alarm notification and additional dedicated NACs for area releasing status notification. uppression releasing is compatible with conventional panel mounted NAC modules as well as for use with the 49 IDNet NAC Extender.. Additional uppression Release Peripheral Reference. Refer to Installation Instructions 579-385. Additional Releasing ystems Reference For additional information, refer to Factory Mutual Research Corporation (FMRC) FMRC Approval Guide, FM Approval standard Deluge ystems and Preaction ystems. Please note that proper operation of releasing control systems requires that the system design, installation, and maintenance be performed correctly and in accordance with all applicable local and national codes, and equipment manufacturer s instructions. No liability for total system operation is assumed or implied. 2 4-4-5

Product election 4E Releasing Control ystem Modules Model Description Reference 28-946 Coil upervision Module Required, one per RAC, mounts in the releasing actuator wiring junction box; see specifications section for details 28-eries* Maintenance witches One per RAC; flush or surface mount; indicator lamp models require separate 24 VDC wiring 28-956* Flush mount 28-957* urface mount Abort witch As required, connects via an IDNet addressable interface module; mounted on a single gang stainless steel plate; installation requires a single gang box, 2-/2 (64 mm) minimum depth * Refer to data sheet 28- for Abort and Maintenance switch details. Releasing Appliqués, Required for 4E uppression Releasing Applications Model Description 4-983 English uppression Releasing Appliqué; field applied (same appliqué as is used on the 4-983CAF French implex model 4 uppression Release Panel) uppression Release Peripheral and Accessories Model Description Reference 49-95 49-96 Basic uppression Release Peripheral on mounting plate uppression Release Peripheral mounted in red box; required for ULC listing 2975-9227 Red mounting box; required for 49-95 49-982 Red LED IDNet communications indicator option kit; mounts on door of 2975-9227 box Requires mounting box 2975-9227, ordered separately Includes LED indicator on front of door These items are included with model 49-96 Additional Product Data heet Reference ubject Data heet ubject Data heet Releasing ystem Abort and Maintenance witches Addressable Manual tations for Releasing Applications Addressable Manual tations for tandard Applications 28-499-2 4 eries, Panel Mount 24 Point I/O and Annunciator Modules 4 eries, Remote Mount 24 Point I/O and Annunciator Modules 4-32 4-5 499- TrueAlarm ensors and Bases 498-9 4E Basic Control Panels 4-3 TrueAlert Electronic Horns 49- upervised IAM 49- TrueAlert Non-Addressable trobes (V/O) 496- Addressable Zone Adapter Modules 49-3 TrueAlert Non-Addressable 4-Wire Horn/trobes (A/V) 493- Contact your local implex product supplier for additional information on compatible IDNet addressable devices and TrueAlert notification appliances. 3 4-4-5

MANUAL RELEAE MANUAL RELEAE - IDNET IN + +IDNET IN - - IDNET IN + +IDNET IN - CAUTI O N : This Cont r ol Unit has been ar r anged f or r eleasing ser vice. Disable al r eleasing device cir cuit s pr ior t o ser vicing. RE D NA C+ N AC - BL K RE D NA C+ N AC - BL K C OIL UPE R VI ION MO DU L E ( 2 A MP ) 2 8-9 4 6 IN T A L L A T ION IN T R UC T IO N 5 7 4-4 3 7 RE VYEL MAIN T A IN /4 " E P AR AT ION B E T W EE N PO W ER L IMIT E D ( R ED / ) A ND NO NP O W E R L IMIT E D ( YE L /BL K) W IRIN G D AT E C OD E: 5 9-9 5 8 IM P L E X T IM E R E C O R D E R C O.G A R D N E R M A.U A C OIL UPE R VI ION MO DU L E ( 2 A MP ) 2 8-9 4 6 IN T A L L A T ION IN T R UC T IO N 5 7 4-4 3 7 RE VYEL MAIN T A IN /4 " E P AR AT ION B E T W EE N PO W ER L IMIT E D ( R ED / ) A ND NO NP O W E R L IMIT E D ( YE L /BL K) W IRIN G D AT E C OD E: 5 9-9 5 8 IM P L E X T IM E R E C O R D E R C O.G A R D N E R M A.U A 4E Releasing ystem One-Line Connection Reference HAZARD AREA 2 49-95/-96 uppression Release Peripheral FIRE RELEAING DEVICE Maintenance Disconnect witch NORMAL Actuator Control Circuit Coil supervisory module Agent source Actuator Class B NAC wiring; dedicated to uppression Release Actuator IDNet communications NAC for horn control NAC for strobe control Agent discharge path Use separate NACs for horn and strobe control to implement audible escalation of events HAZARD AREA 24 VDC for Maintenance Disconnect status indicator (if required) Actuator Control Circuit IDNet communications (shown as Class B wiring) FIRE RELEAING DEVICE NORMAL Coil supervisory module Agent source Actuator upervised IAM with optional Abort witch IDNet Addressable devices Class B NAC wiring; dedicated to uppression Release Actuator Agent discharge path UPPREION RELEAE PANEL NAC for horn control NAC for strobe control Use separate NACs for horn and strobe control to implement audible escalation of events uppression Release Appliqué wording: 4E Control Panel with uppression Release Appliqué UPPREION RELEAE PANEL CAUTION: This Control Unit has been arranged for releasing service. Disable all releasing device circuits prior to servicing. 4 4-4-5

NORMAL MANUAL RELEAE - IDNET IN + +IDNET IN - IM P L E X T IM E R E C O R D E R C O.G A R D N E R M A.U A uppression Release Peripheral Wiring Reference Maximum Release Appliance Circuit (RAC) Wiring Distances from uppression Release Peripheral to the Valve olenoid (based on a total drop of.6 V) RAC Output Current Distance (refer to solenoid rating) 8 AWG 6 AWG 4 AWG Total Line Resistance.5 A 74 ft 23 m 8 ft 36 m 88 ft 57 m.6.75 A 5 ft 5 m 79 ft 24 m 26 ft 38 m.7. A 37 ft m 59 ft 8 m 94 ft 29 m.53.25 A 3 ft 9 m 47 ft 4 m 75 ft 23 m.6.5 A 25 ft 7.6 m 39 ft 2 m 63 ft 9 m.7.75 A 2 ft 6.4 m 34 ft m 54 ft 6 m.53 2. A 9 ft 5.8 m 3 ft 9 m 47 ft 4 m.53 Metric wire equivalents: 8 AWG =.82 mm 2 ; 6 AWG =.3 mm 2 ; 4 AWG = 2.8 mm 2 NORMAL Maintenance Disconnect witch Yel Red + + Out In - - Blk Blk Listed/approved actuator or Deluge and Preaction Automatic Water Control Valve; one if 24 VDC (or 2 in series if 2 VDC) per RAC Valve wiring junction box 49-95/-96 uppression Release Peripheral Coil upervision Module 28-946 24 VDC power for indicator lamp (2 wires) FIRE RELEAING DEVICE Release appliance circuit COIL UP E RV I ION MODUL E ( 2 A MP ) 2 8-9 4 6 R E D IN T A L L A T ION IN T RUCT ION 5 7 4-4 3 7 RE V Y E L N A C + MA INT A IN /4 " E P A RA T ION B E T W E E N P OW E R L IMIT E D ( R E D / ) A N D N ON P OW E R L IMIT E D ( Y E L / ) W IRING DA T E CODE : 5 9-9 5 8 N A C - Addressable devices Class B NAC wiring dedicated to uppression Release Peripheral upervised IAM with optional Abort witch IDNet communications, Class A or Class B To 4E, 4U or 49 IDNet NAC Extender Maximum Notification Appliance Circuit (NAC) Wiring Distances to a uppression Release Peripheral (.5 A to.75 A drop is based on a total drop of 3.4V; 2 A drop is based upon a total drop of.2 V) RAC Output Current Distance (refer to solenoid rating) 8 AWG 6 AWG 4 AWG Total Line Resistance.5 A 25 ft 76 m 399 ft 22 m 635 ft 94 m 3.58.75 A 67 ft 5 m 266 ft 8 m 423 ft 29 m 2.39. A 25 ft 38 m 99 ft 6 m 37 ft 97 m.79.25 A ft 3 m 59 ft 48 m 254 ft 77 m.43.5 A 84 ft 26 m 33 ft 4 m 22 ft 65 m.9.75 A 72 ft 22 m 4 ft 35 m 8 ft 55 m.2 2. A 25 ft 7.6 m 39 ft 2 m 63 ft 9 m.36 Metric wire equivalents: 8 AWG =.82 mm 2 ; 6 AWG =.3 mm 2 ; 4 AWG = 2.8 mm 2 28-956/-957 Abort witch (as required) 5 4-4-5

pecifications uppression Release Peripheral 49-95 and 49-96 Communications RAC Output Rating NAC Power Requirements NOTE: 4E NACs are rated at 3 A; 49 IDNet NAC Extender NACs are rated at 2 A, Extender expansion NACs are rated.5 A Wire Connections IDNet Wiring Distance Reference IDNet, one address with 4E/4U 2 A maximum with 49 IDNet NAC Extender A maximum upervisory Current Alarm Current Reference (RAC current = actuator current) Voltage 6 to 32 VDC (nominal 24 VDC) At nominal 24 VDC, regulated; refer to NAC Power Requirements for more detail No additional current required, circuit appears as standard end-of-line (EOL) NAC loading RAC Current NAC Current RAC Current NAC Current.5 A.845 A.25 A 2.4 A.75 A.28 A.5 A 2.56 A.87 A.5 A.75 A.7 A 2 A crew terminals for input and output wiring, 8 to 2 AWG wire (.82 mm 2 to 3.3 mm 2 ) Up to 25 ft (762 m) from the IDNet source module Up to, ft (348 m) total Class B wiring distance including T-Taps Compatible with implex 28-944 Overvoltage Protectors Dimensions ee installation reference on page 8 Operating Temperature 32 to 2 F ( to 49 C) indoor operation only Operating Humidity Range to 9% RH at 9 F (32 C) Coil upervision Module 28-946 Construction Dimensions Wiring Current Rating Epoxy encapsulated -3/8 W x 2-7/6 L x -/6 H (34 mm x 62 mm x 27 mm) 8 AWG (.82 mm 2 ) wire leads, color coded 2 A Maximum; internally fused at 3 A, non-replaceable 3 A Compatible UL Listed Valves and Actuators MFG. Model Number Coil Details MFG. Model Number *AUTOMAN II-C Assembly; solenoid 7728; coil 25924 2 VDC, 458 ma ANUL kinner AUTOMAN II-C Explosion-Proof Releasing Device; solenoid 3492; coil 3438 *AUTOMAN II-C Assembly; solenoid 68739; coil 25924, olenoid Electric Actuator; solenoid 73; coil 7397 *CV9 HF Electric Actuator 73327; may use 7366 in-line resistor for 2 VDC 24 VDC, 467 ma 82A7 (9767-5D coil) /2 NP, 5/8 orifice, 24 VDC 82G27 (2383 coil) /2 NP, /2 orifice 2 VDC, 458 ma ACO 82A7 (9767-5D coil) 24VDC 24 VDC, A HV262857 (238 coil) N.C. /2 NP, /2 orifice 9 VDC max, 45 ma HV264858 (238 coil) N.O. /2 NP, /2 orifice R82A7 (9767-5D coil) /2 NP, 5/8 orifice LP CO2 w/aco solenoid 422934, 24 VDC, 442 ma T82A7 (9767-5D coil) /2 NP, 5/8 orifice LP CO2 double action solenoid 43948 LP CO2 3-way selector valve solenoid 43349 Electric Actuator 24 VDC solenoid 57537 24 VDC, 438 ma 7395N2ENJNOHC2 (kinner coil HC2) /4, NP, /6 7322BN4TNNOCC2 (kinner coil CC2) /2, 5-3 psi 7322BN4TNLVNOC322C2 (kinner coil C322C2) /2, NP,.92 A, 25 psi 7328BN4UNLVNOHC2 (kinner coil HC2) 7328BN4UNLVNOCC2 (kinner coil CC2) /2, NP, 5/8 in. orifice ECH Electrical Control Head (552) 24 VDC, 438 ma Pyro- Explosion-Proof Electric Actuator (5747) Chem 24 VDC, 25 ma Removable Electric Actuator (5729).2 A * 2 VDC coils, either wire two in series for 24 VDC activation, or, if available from manufacturer, use series resistor 6 4-4-5

FM Approved Water Control Valves FM Group Manufacturer Model Number Details A kinner LV2LBX25* 24 VDC, W, 458 ma, /2 inch NP, /2 inch orifice T82A7 B ACO R82A7 24 VDC, 6.8 W, 7 ma, /2 inch NP, 5/8 inch orifice 82A7 D ACO 82G27 24 VDC,.6 W, 44 ma, /2 inch NP, /2 inch orifice 7328BN4UNLVNOCC2* 24 VDC, W, 42 ma, /2 inch NP, 5/8 inch orifice E kinner 7322BN4TNNCC2 24 VDC, W, 42 ma, /2 inch NP, 5/8 inch orifice; 5-3 psi rated working pressure F kinner 7322BN4TNLVNOC322C2 24 VDC, 22 W, /2 inch NP, 92 ma, 25 psi (725 kpa), /2 inch orifice G kinner 7395N2ENJNOHC2 24 VDC, W, 42 ma, /4 inch NP, /6 inch orifice, 25 psi (725 kpa) rated working pressure I Vitaulic eries 753-E solenoid valve 24 VDC, 8.7 W, 2 inch NP, 364 ma, 3 psi (269 kpa), 2 inch orifice J Viking 59 and 592 Normally closed (NC) 595 and 596 Normally open (NO) Explosion proof solenoid valves, 24 VDC, W, 2 inch NP, 3 psi (269 kpa), 4. Cv K Viking 6 and 62 NC solenoid valve, 24 VDC, 9 W, 2 inch NP, 25 psi (725 kpa), 6.2 Cv * For new applications, LV2LBX25 has been replaced by model number 7328BN4UNLVNOCC2. 7 4-4-5

ON 2 3 4 5 6 7 8 uppression Release Peripheral Installation Reference Diagram 2975-9227 Box, red with white lettering (supplied with 49-96) Door hinges on left and lifts off for access 4 Knockouts, one each side Door height 8-/8" (26 mm) Door screw fastener 49-982 LED indicator option (supplied with 49-96) Door depth /2" (3 mm) Door width 6-/8" (56 mm) Box depth 4" (2 mm) Box depth with door 4-/6" (3 mm) 49-95 uppression Release Peripheral assembly (supplied with 49-96) NAC + NAC - IDNet+ IDNet- RAC - RAC + Box height 8" (23 mm) IDNET UPPREION RELEAE PERIPHERAL AY 566-4 Box width 6" (52 mm) Tyco is a registered trademark of Tyco International ervices GmbH and is used under license. implex, the implex logo, TrueAlarm, TrueAlert, martync, and IDNet are trademarks of Tyco International Ltd. and its affiliates and are used under license. Tyco afety Products Westminster Westminster, MA 44- UA 4-4-5 www.tycosafetyproducts-usa-wm.com 2 Tyco afety Products Westminster. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice.