KEEP THE FIRE FROM SPREADING

Similar documents
Iv. 5. FIRE-RESISTANT GLASSES Introduction Pyrobel and Pyrobelite Pyropane 372

fire protection glass

fire protection glass

Fire Protection. Fire-resistant glasses. Pilkington Pyrostop Fire Resistance Glass Pilkington Pyrodur Fire Protection Glass

ProdUCT SeleCTo. Clear Fire resistant Glass

STOPLINE FIRE RATED GLAZED

Questions related to specific materials, methods, and services will be addressed at the conclusion of the presentation.

SGG CONTRAFLAM LITE SAINT-GOBAIN GLASS PROTECT

Schueco Fire and Smoke Protection Systems

GENERAL FIRE SAFETY TERMS & DEFINITIONS

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

PYRAN PYRANOVA NOVOLAY secure PYRANOVA secure

Objectives. To review updated IBC and fire test requirements when designing for life safety.

Loss Prevention Standards

Limiting Distance. National Building Code of Canada and Ontario s Building Code. CAN4 S-106. Is a cost effective

NOVOLAY secure. PYRANOVA secure. Special glass types with outstanding safety properties

Fire protection documentation. CFPA-E Guideline No 13:2015 F

Fire Protection. Fire-resistant Glass Range. Pilkington Pyrostop. Pilkington Pyrodur

Fire Risk Assessment 2017

- CONSTRUCTION FIRE SAFETY STANDARDS

Introduction of MSBC Secure India Pvt Ltd. Manufacturer & Installer of Fire Resistance Timber Doorsets

Fire Protection. Fire-resistant glasses. Pilkington Pyrostop. Pilkington Pyrodur

Life Safety and Fire Resistant Glazing Systems

Unit 2 Fire Safety (Zone 1)

PYRAN PYRANOVA NOVOLAY secure PYRANOVA secure

FP-PGN-14 Part of NTW(O)41 Fire Policy

The Role of Glass in Fire Protection

- CONSTRUCTION FIRE SAFETY STANDARDS

Keller Minimal Windows, Solarlux, Renson, Reynaers, Hawa, RP Technik, KL Megla, Promat, PBA, Franz Nusing wooden, acoustic glazed fire doors SEA

SGG CONTRAFLAM SAINT-GOBAIN GLASS PROTECT

PART 1 GENERAL 1.01 SUMMARY

Loss Prevention Standard

Active & Passive Fire Protection System. Page 1 Kalidasan S BT IN SSP-OP

IFE Level 4 Certificate in Fire Science and Fire Safety

The Passive Fire Protection Handbook

Date and Time of Incident. Feb. 13, 1964 Breakout at15:33 (approx.) Noticed at 15:27 Notified by emergency call. Extinguished by 21:07

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY)

TYPE 1 FIRE RISK ASSESSMENT REVIEW (NO DESTRUCTIVE AUDIT)

Protect human life against hazards at refineries and other sensitive. Complete cabin protected against blast, gas, fire and smoke

The Physical Environment Portal: Module 5, LS Leadership

Fire Enforcement Report

Pilkington K Glass. Pilkington K Glass

Pilkington K Glass Range

Fire resistance. Appendix E. E.1 Fire resistance. Appendix. (A copy of this Appendix is available on /)

Design Guidelines Fire Safety in New and Refurbished Buildings

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE EMERGENCY PLAN

The Association for Specialist Fire Protection. Understanding Best Practice in passive fire protection

FIRE DEPARTMENT - RULES FOR FIRE PROTECTION IN AUSTRIA

Passive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection

The following translation is for informative purposes only. The legally binding text is found in the Boverket s Code of Statutes (

Fire Safety Checklist

161 Rosebery Avenue, London, EC1 Fire Safety Management Plan & Evacuation Procedures

Are we using the wrong design fires for tall building fire strategies, in light of recent full height fires?

GENERAL STAND BUILDING REGULATIONS AND INFORMATION

Agency for Health Care Administration

fire resistance testing

Health, Safety and Wellbeing Management Arrangements. Core I Consider I Complex. Fire Safety. Health, Safety and Wellbeing Service

P.O. Box NL-2665 ZN Bleiswijk Brandpuntlaan Zuid 16 - NL-2665 NZ Bleiswijk The Netherlands

HEALTH, ENVIRONMENT AND SAFETY MANAGEMENT FOR FACILITIES MANAGERS COURSE OUTLINE

FIRE DOORS RHUL REQUIREMENTS

The following are the Proposed Amendments to 2015 edition of the Life Safety Code (NFPA 101):

Automatic Sliding Door Systems

BRE: Stay-put or Evacuate? Carl Sherwood BRE Fire Safety Group 22 nd July Part of the BRE Trust

Product Selector. Clear Fire Resistant Glass for the Marine

Transaction Windows and Security Entrances

Academic and Administrative Buildings

AFEC FIRE ENGINEERING TEMPLATE FOR CLIENTS INTERNALLY COMPLETED RISK ASSESMENT

Fire Risk Management Policy. UK September 2017

SMOKE & FIRE THE LEADING EDGE IN. Smoke & Fire Curtains

Fire Risk Assessment. ABC Car Workshop. Prepared for. Redacted

Fire Safety Audit: Part B - Questionnaire (Questionnaire Devised By Mr.R.R.Nair) Yes No x

Specifying Security Hardware for Doors

PART 1 GENERAL 1.01 SUMMARY

8.1. Fire and Heritage. The maintenance series. Information sheet. Guidelines on Fire Safety in Heritage Buildings

Chapter Nursing Homes

technical specification smoke venting systems

INSPECTOR I SKILLS ADMINISTRATION

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

ISLE OF WIGHT FIRE & RESCUE SERVICE

F.R.A.M.E. EVENT NETWORKS used in "FRAME".

The Social Accountability International (SAI) Fire Safety Checklist

Charlotte Building, 17 Gresse Street, London W1T 1QL

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

Fire Safety Log Book. Safety through knowledge East Coast Safety Training. Kevin James (Proprietor) 99 Johnson Estate Wheatley Hill Durham DH6 3LH

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

Fire Certificate. An issue of Maintenance from the Technical and Legal perspective

Fire and Security Products and Services

CEN/TC 33 - Doors, windows, shutters, building hardware and curtain walling. EN 107:1980 Methods of testing windows - Mechanical test 89/106/EEC

Fire Rated Door Assemblies: Compliant Designs

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

UCL PRINCIPAL CONTRACTOR SITE FIRE SAFETY RISK REVIEW & MITIGATION MEASURES

Fire Safety Strategy

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE

The Passive Fire Protection Handbook

UK Product Guide. Fire Doors.

FIRE SAFETY LOG BOOK

Fire Risk Assessment 2016

Slight Harm Moderate Harm Extreme Harm Low Trivial Risk Tolerable Risk Moderate Risk Medium Tolerable Risk Moderate Risk Substantial Risk

Crosswalk of 2014 HFAP Standards against HFAP Standards Acute Care Hospital Manual

Welcome to the. Firestop Seminar. Hilti Technical and Engineering Support

Transcription:

KEEP THE FIRE FROM SPREADING

Fire might be a symbol of man s development in the world, but when it is out of control it could cause enormous damage to the surroundings. Especially when it comes to fire hazards in buildings, the occurrence of fire can be unpredictable and disastrous. It could spread wildly and cause significant threat to life and property. Therefore it is critical that fire-safety materials and fire-resistant products measure up to the highest possible standards of performance. In today s building design and construction, glass has become an integral part of architecture and interior design. The right type of glass product used under proper norms and guidelines, can help reduce the destructive effects of fire significantly and save lives. This is where AIS Pyrobel comes in. 1

Importance of Fire Protection Systems A small spark is enough to cause a huge incident. By establishing a fire prevention plan for your building, you can avoid fatalities and costly damages. Fire-prevention systems can broadly be classified into two categories: Active Fire Protection and Passive Fire Protection. Active Fire Protection (AFP) systems require a certain motion and response to combat fire and can be either automatic or manual. These systems require periodic maintenance and audits to verify their workability and response to fire. Passive Fire Protection (PFP) systems prevent the spread of fire by creating barriers to its passage for a limited time, enabling occupants to move to a safe environment. PASSIVE FIRE PROTECTION Constructional Escape Routes Compartmentation Behaviour of Construction Materials in Case of Fire FIRE PROTECTION SYSTEM Technical Sprinkler Systems Extinguishers Flues Hypoxic Air Suppression ACTIVE FIRE PROTECTION Organisational Ordinances of Workplaces Instructions to Occupants Fire Safety Regulations Fire Safety Drills and Audits Public Fire Department Water Supply Emergency Calls Fire Alarms Regulations Around the World for Passive Fire Protection Country Europe Germany UK USA India Standards Institute Test DIN EN 1363 DIN 4102 BS 476 UL 9 efectis \ TNO Impact and Fire Test DIBt Warrington Hose Stream Test EN 1363/UL 9/ BS 476 CBRI Impact, Fire, and Hose Stream Test 2

PFP is an essential fire safety strategy for any building. If proper planning, installation, and maintenance are implemented, passive fire protection can save lives and the building itself. While PFP may not provide a complete fire safety solution, when combined with AFP, they can make a big difference in case of an emergency. Types of Regulated Openings Rated Doors Rated Windows Rated Glazing Access doors Accordion / folding doors Bi-parting doors Conveying system doors Chute doors Dutch doors Floor fire doors Hoist-way doors Horizontal doors Casement windows Double hung windows Glass Block Hinged windows Pivot windows Side lights Stationary windows Tilting windows Transom windows Clear ceramics Insulated glass Laminated glass Light diffusing plastic Light transmitting plastic Fire-rated Glazing Tempered glass Transparent ceramics Wire glass 3

4

AIS Pyrobel AIS Pyrobel is a high-end fire-resistant glass range, specially engineered to withstand extreme levels of heat, restrict heat transfer, and prevent the smoke and flames from spreading. It can easily replace a traditional brick wall in terms of fire-rating property. This helps enhance the aesthetics of the room, and at the same time provides a clear vision of the other side. In case of a fire outbreak, AIS Pyrobel can play a pivotal role in containing damage to life and property caused by fire, and give enough time for the occupants to implement a safe evacuation plan. It is designed to meet the fire protection ratings specified by national building regulations. Pyrobel: From AGC to AIS Pyrobel is a proven and tested product of AGC. AGC has had a strong influence in promoting technologically advanced glass products in India through AIS. With an increase in fire outbreaks in India, the need for worldclass fire-resistant glass products has become the need of the hour. Therefore, to enhance the design and safety standards of buildings in India, Pyrobel is brought to you by AIS. 5

Features and Benefits Provides safety against fire, heat, and smoke for extended periods Ensures protection against radiation and conductive heat transfer Double-sided fire-resistant glass, thus provides protection on both the sides Rated EW 30, EW 60, EW 120, EI 30, EI 60, EI 90, and EI 120 Safety glass according to EN 12600 (3B3, 2B2, or 1B1 according to product type) and BS 6206 (class C, B, or A according to product type) Approved in wooden, steel, and aluminium framing systems Approved in frameless systems (butt-joint) named PYROBEL VISION LINE Available as single internal glazing, single external glazing with a UV filter (EG type), and double glazing unit (DGU) in combination with any other AIS glass product Additional Benefits Provides excellent noise reduction of up to 49 decibels Resists high loads of pressure, making it almost unbreakable Inspires architects and designers to create a safe and aesthetically pleasing environment It can also be used in double glazing for exterior façades which provides solar and thermal protection with higher light transmission value 6

7

8

Fire-Resistant Glass Types AIS Pyrobel presents a comprehensive range of fire-resistant glass products, tested and approved according to Indian and international standards. They provide a unique combination of light, transparency, and fire protection for all building applications, framing types, and fire-resistance classes and durations. Class E: The glass prevents flames, smoke, and hot gases from passing through. The fire remains contained. Class EW: Integrity and Low Heat Radiation or the ability of the element to prevent the passage of flames and to limit the level of heat transfer through the element. Class EI: Integrity and Insulation or the ability of the element to prevent the passage of flames and to block heat transfer through the element. The required fire protection rating is specified by the respective national building regulations following a risk assessment based on the building characteristics and the location of the fire-rated element (façade, partitioning walls, stairways, etc.) Fire Protection Ratings Class / Duration 15 mins 20 mins 30 mins 45 mins 60 mins 90 mins 120 mins DH - - DH30 - - - - E - E20 E30 - E60 E90 E120 EW - EW20 EW30 - EW60 EW90 EW120 EI EI15 EI20 EI30 EI45 EI60 EI90 EI120 9

Choose your AIS Pyrobel Safety Rating on Fire Rating Building Application FR Glass Approved Sizes (1) Product (2) EN 13501-2 EN 12600 3B3 Medium PYROBELite 7 EW 30 2B2 Medium PYROBELite 10 1B1 Medium PYROBELite 9 EG Interior Doors & Screens Single Glass EW 60 2B2 Medium PYROBEL 16 PYROBELite 12 EW 120 1B1 Medium PYROBEL-T EW 120-16 EI 30 2B2 1B1 Large PYROBEL 16 Large PYROBEL 16 EG EI 60 1B1 Large PYROBEL 25 & 25 EG EI 90 1B1 Large PYROBEL 30 EI 120 1B1 Large PYROBEL 53N EI 30 2B2 1B1 Large Large PYROBEL 16 Vision Line PYROBEL 16 EG Vision Line Interior Screens Butt-Jointed Single Glass EW 120 1B1 Medium PYROBEL T EW 120-16 Large PYROBEL 25 Vision Line EI 60 1B1 Large PYROBEL 25 EG Vision Line EI 120 1B1 Large PYROBEL 53N Vision Line EW 30 1B1 Medium PYROBELite 9 EG IGU Outside Windows & Curtain Walls Double Glass EI 30 1B1 Large PYROBEL 16 EG IGU EI 60 1B1 Large PYROBEL 25 IGU EI 90 1B1 Large PYROBEL 30 IGU EI 120 1B1 Large PYROBEL 53N IGU Horizontal Floors & Ceilings Single Glass EI 30 1B1 Medium PYROBEL 19 H EI 60 1B1 Medium PYROBEL 28 H (1) For more information about the approved framing systems and sizes, please refer to the respective Product Data Sheets (2) Pyrobel(ite) in IGU structure can be either 6 - air - Pyrobel(ite) EG or Laminated glass 33.2 - air - Pyrobel(ite), all combined with or without all types of coatings All Pyrobel(ite) EG structures can be combined with Stratobel approved Anti-bandit (EN 356) or Anti-bullet (EN 1063) glasses. 10

11

Technical Specifications Parameters Technology Pyrobelite 7 EW 30 Multilayer Clear Intumescent Interlayer Pyrobelite 12 EW 60 / EI 20 Multilayer Clear Intumescent Interlayer Pyrobel-T EW 120-16 / EI 20 Tempered Gel filled Pyrobel 16 EW 60 / EI 30 Multilayer Clear Intumescent Interlayer Pyrobel 25 EI 60 Multilayer Clear Intumescent Interlayer Pyrobel 30 EI 90 Multilayer Clear Intumescent Interlayer Pyrobel 53N EI 120 Multilayer Clear Intumescent Interlayer Glazing Type* Single Single Single Single Single Single Single Application * Interior Interior Interior / Exterior Interior Interior Interior Interior Nominal Thickness 7.9 mm 12.3 mm 16mm 17.3 mm 26.6 mm 30.0 mm 52.7 mm Thickness Tolerance ± 0.9 mm ± 1 mm ± 1 mm ± 1 mm ± 2 mm ± 2.5 mm ± 3 mm Weight 17 Kg/Sq.m 27 Kg/Sq.m 36 Kg/Sq.m 40 Kg/Sq.m 60 Kg/Sq.m 69 Kg/Sq.m 122 Kg/Sq.m Dimension Tolerance ± 2mm ± 2mm ± 2mm ± 2mm ± 2mm ± 2mm ± 3mm Light Transmission (EN410) 89% 86% 87% 84% 81% 83% 75% Ug Value (EN 673) 5.7 W/Sq.m K 5.6 W/Sq.m K 5.4 W/Sq.m K 5.4 W/Sq.m K 5.2 W/Sq.m K 5.1 W/Sq.m K 4.5 W/Sq.m K "Safety Rating (BS6206) (EN 12600)" "Sound Reduction Rw Index 9EN12758)" "Class C 3B3" "Class B 2B2" "Class A 1B1" "Class B 2B2" "Class A 1B1" "Class A 1B1" 34 db 36 db 37 db 39 db 40 db 42 db 48 db Cuttable Yes Yes No Yes Yes Yes Yes *For fire resistance glass of high performance parameter, to be used as exterior façade, please get in touch with our sales team "Class A 1B1" 12

Where can AIS Pyrobel be used? Partitions Fire-rated glass serves as an exceptional material of choice for creating these compartments due to its transparency, longevity, and almost zero-maintenance. Fully Glazed Fire Doors A glass-glazed option to regular fire-doors provides complete transparency and better aesthetics. Façades and Windows When used in façades, they stop the fire from transmitting inside-out or outside-in. Floors Fire-safe floors utilize glass and other glazing materials to stop the flow of fire between floors. Data Storage and Server Room Enclosures Preservation of electronic data against risk of fire is critical and almost all server and data room enclosures are now designed with fire-rated glass products. Stair Enclosures Staircases are the fastest and safest exit routes in most constructions and it is important to protect their access points with fire-rated doors with inbuilt vision panels. These vision panels greatly assist in understanding the extent of fire and help facilitate coordinated getaways from fire-affected areas. Lift Doors and Enclosures Fire-rated glass doors help in identifying potential survivors on either side as the glass is transparent throughout the fire and can greatly help rescue efforts. 13

Compliance Fire resistance glass products are only part of overall fire-resistant elements. It is the responsibility of the installer to ensure that the fire-resistant element as a whole satisfies the regulations and / or to obtain the approval from the competent authorities. AIS does not accept any liability should the fire-resistant glass be installed in systems that do not comply with regulations. A visible stamp should be placed on the glass in order to identify the product with its classification and position in the structure. AIS Pyrobel is a 2 sided fire-resistant glass. For correct installation in case of UV radiation, the stamp must be readable from the inside of the building. Storage and Handling Instructions On racks, Fire-Resistant Glass Products must be stored slightly inclined (6 to 10 from the vertical) and fully supported A soft spacer must be placed between each glazing Do not pile up more than 20 sheets per rack 14 Must be stored in dry and ventilated conditions, at temperatures ranging between -40 C and +50 C.

Installation and Glazing Instructions AIS Pyrobel cannot be cut on site and the edge protection tape must not be removed nor damaged Before installation, AIS Pyrobel must be checked to ensure that it is not damaged, especially along the edges Do not allow any contact of the glazing s edges with water Avoid all glass-to-metal contact Do not exercise any restraint on the glazing Do not install AIS Pyrobel in locations where the temperature might exceed +50 C Always refer to the fire test report details For external applications, or in case of direct solar radiation on the glazing, AIS Pyrobel is available as an external grade (EG), with a UV filter Pyrobel External Grade must be correctly oriented with its stamp readable from the UV opposed side Uncompromising Quality The quality and performance of the AIS Pyrobel range is carefully controlled at each step of production. Due to the nature of the special intumescent interlayers, they may exhibit or develop some minor imperfections such as small inclusions and bubbles, a slight distortion, and a light haze. These features do not affect the free vision nor shall the fire resistance of the glazing be considered defective, provided the variation of haze and light transmission does not exceed 5%. 15

AIS Pyrobel Projects Butt-jointed Partition Pyrobel 16+6 EG VL EI 30 Pyrobel 25 EG with Opaque Film Butt-jointed Partition Pyrobel 16 EG VL EI 30 Butt-jointed Screen, EI 30 with angle 45 Pyrobel 16+6 EG VL Pyrobel 25 IGU 16

Butt-jointed Screen EI 60 Pyrobel 25 EG Vision Line Pyrobel 25 for Interior Doors and Fixed Partitions Pyrobel 25 IGU Pyrobel 25 Vision Line 17

When it comes to ensuring safety of your building and the occupants, you can t afford to take any chances. The investment in high quality architectural design ensuring fire safety in buildings is the best solution for new building projects in order to protect human life and financial investment. With AIS Pyrobel, it s time you prepare for the unexpected fire breakout in your buildings and minimize the fatality. We at AIS, have been trusted and relied on by builders, architects, and designers for our glass solutions over the last several years. Whatever your requirements, we re dedicated to providing multifunctional, specialised glass solutions for safe, secure, and comfortable living. For more information on giving your building the ideal protection along with enhanced aesthetics, get in touch with our experts. Asahi India Glass Ltd. (AIS) Unit No. 305 to 308 and 312 to 314, 3rd Floor, Platinum Techno Park, Sector - 30A, Vashi, Tal & Dist - Thane, Navi Mumbai 400 705 seemore@aisglass.com www.aisglass.com