USER INSTRUCTION MANUAL SAPPHIRE SERIES 1100 & 1100EC

Similar documents
USER INSTRUCTION MANUAL SAPPHIRE SERIES 800

User Instruction Manual

User Instruction Manual

User Instruction Manual

User Instruction Manual

Baros Comfort Turn Mattress

User Instruction Manual

CANAIR Products Available from Sunrise Medical

SERVICE PROCEDURES. Mattress 2 Pipe Overlay or Replacement

DELUXE ALTERNATING PRESSURE SYSTEM USER GUIDE

AIR EXPRESS LAL. P1500 LOW AIR LOSS THERAPY SYSTEM REF C1500 Control Unit REF M1500 Mattress. Operator s Manual P/N /03

Anti-Decubitus Air Alternating Pressure Mattress System Operation Manual

PRELUDE. User Manual. PA3500 Mattress Overlay System. Guarantees and Warranty. 1.1 General Information 1.2 Intended Use. 3.1 Unpacking 3.

MULTI-FUNCTIONAL PORTABLE ROTATION SYSTEM P4000 P4001 C4000 Series Control Unit M4000 Series Mattress. Operator s Manual P/N Rev B 10/10

Med-Aire 8 Alternating Pressure Mattress Replacement System With Low Air Loss OPERATOR S MANUAL

AMBIENCE Low Air Loss Mattress Replacement System

User Manual standard for Medical Electrical. Control Number 95CG. Classified by. Underwriter s Laboratory Inc. for UL

Med-Aire Assure 5 Air + 3 Foam Base Alternating Pressure and Low Air Loss Mattress System

Enhance DX. Mattress Replacement System. User Manual

English 1 AIR ALTERNATING PRESSURE MATTRESS REPLACEMENT SYSTEM

Dyna-Form Air. Alternating Pressure Relief Overlay System

The FAWSsit USER CARE GUIDE

User s Manual. Alternating Air Mattress Model No.: MA-6100

E N T E R P R I S E S, L L C. Innovative health solutions

Convertible Powered/ Non-Powered Dynamic Mattress System. Operation Manual. Distributed by:

Delta Plus. PA8900 Bariatric Mattress Replacement System. User Manual

APH166 Morpheus Air USER MANUAL. Issue 3-24/05/2017. Apollo Healthcare Technologies Ltd. Holme Street, Liversedge, West Yorkshire, WF15 6JF.

User manual CuroCell S.A.M. Static Antidecubitus Mattress. User manual item number:

User Manual. Invacare APM Model CG9900 Mattress

Mobile Evaporative Cooler. Use & Care Guide MC37 / MC61 INDEX

Safety Information Contents List Odorox Boss XL3 Unit Operational Guidelines Operating The Odorox Boss XL3... 4

AIR. Low-Air Loss Combined with. Advanced Wound Therapy & Fall Prevention in a Non-Powered Mattress. Non-Powered Therapy

User manual CuroCell Neo CX13 CuroCell Neo CX19 Alternating pressure mattress. Item number user manual:

Mobile Evaporative Cooler. Use & Care Guide MC18M INDEX

Mason Air AS8800/ AS8800-RR/AS Instruction Manual. Low air loss/alternating pressure mattress

Decon Scrubber Owner s Manual

User manual CuroCell S.A.M. Switch Static Antidecubitus Mattress. User manual item number:

Energedry Eliminator 52K

WINDSOR ACTIVE REPLACEMENT

Energedry Elite Eliminator Pest Control Electric Heat System

Manual Parts Washer. Operating Instructions & Warranty Information

DIRECTHEALTHCAREGROUP.COM. Air Suresse. Service Manual

INDUSTRIAL - SOLVENT PARTS CLEANER CM200 (115V OR 230V PUMP)

BIOVAC 500 SMOKE EVACUATOR

MODEL SF-420. Fabric Steamer. by Top Innovations, Inc. Please read all instructions before use. Mail in your warranty registration card.

Rapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times

Energedry Elite 52K. Operations Manual. Pest Control Electric Heat System. For Professional use only. EPA EST. No AZ-001

DOC AP Lo50 Owner's Manual REV 001 Page1

SERVICE PROCEDURES. Control Unit 220DIO 4 pipe

OPAL ACTIVE OVERLAY SYSTEM

Service Manual DIRECTHEALTHCARESERVICES.CO.UK

V 02/09 AN SS RE OWNM

CLOSEDRIER USER GUIDE

Compression therapy device & accessories Model 701A User manual

With Remote Control. English

WA A Aqua Sub Bottom-load Water Cooler

Canister Vacuum. OWNER S MANUAL Models CV520HB/HR/HY 120V., 60Hz., 10 Amps

Juna Ceiling Fan JU54. Installation Instructions Instrucciones de instalación Instructions d installation

Instruction Manual Item No.: V~, 60Hz

C-Box 100, H-Box 200 & H-Box 500

Manual for MC91 SETUP INSTRUCTIONS

FagronLab NP-1 UV. Negative pressure workbench. User Manual

Model: SF-450 PROFESSIONAL STYLE STEAMER

NP317W

Manual update 2016 MC37/MFC3600

Bag-In-A-Box Oil System Instruction Manual Model #2257EX & 2257DX For Export Bag-In-Box Pumps Made After March 2003

Manual for MC37/MFC3600

OPERATING and MAINTENANCE INSTRUCTIONS Models: H138NPSCLCMCQRL Merchandising Hot Cabinets

ELECTRIC UNDER BLANKET QUEEN FLEECY FITTED MODEL NO: TT-1101XQF INSTRUCTION MANUAL

Operator s Manual CAYENNE HEAT N SERVE 4/3 RECTANGULAR RETHERMALIZER ENGLISH

2001 Smith Eastern Corporation

PUMP. General User/ Safety Guide HARVEST 1 PUMP. E

PRESSURE WASHER. OWNER'S MANUAL Model VPW49HA 120V., 60 Hz., 13 Amps.

Manual for MC21A SETUP INSTRUCTIONS

FLCH4R Garage and Utility Electric Heater

User Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858)

8070 Mytee Lite. Instructions for. Please read before use. Register your product at support/register.

Instruction Manual Item No.: V~, 60Hz

Instructions for Installation and Use

Owner s Guide. Powerhead Canister Vacuum Cleaner

5300, 5300CH, 5300EX, 5300FN

K Specifications. Max. Water Volume

OPERATION MANUAL AND WARRANTY ELECTRONIC INFRARED ZONE HEATING SYSTEM

Service Manual Models CPH2 & CPH3

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

WALL MOUNTED ELECTRIC FIREPLACE HEATER. Model # : Onyx Ivory Mirror OWNER S MANUAL. AC V 60Hz 1500W

18 MaxxAir Portable Evaporative Cooler Owner s Manual This Manual covers the EC18DVS MaxxAir Portable Evaporative Cooler.

Instruction Manual. Nacho Cheese Dispenser and Warmer

Operator s Manual. Model G14TC-3 Disinfection Soak Station for Transesophageal Ultrasound Probes

10QT AND 6QT BACKPACK VACUUMS

Full Size Canister Service Manual Riccar Models 1700 / 1800 Power Nozzles RPB-100 / RPB-220 / RPB-224 / RPB-250

Operating Manual. Theraflow. Alternating Mattress Replacement Systems. Model MRS-TFW-001 Standard

Read instructions before operating. Retain for future reference.

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

Instruction Manual. Astro Staging Cabinet

True Hepa Shark Plus Canister Vacuum Model EP238 Use and Care Instructions

Instruction Leaflet. Heater with Adjustable Thermostat PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

Burn Easy Installation Instructions LP or Natural Gas Fired Units. Cremator Setup:

OPERATOR S MANUAL & PARTS LIST

Thanks for shopping with Improvements! Quartz Comfort Furnace Heater Item #470295

Transcription:

USER INSTRUCTION MANUAL SAPPHIRE SERIES 1100 & 1100EC Read Entire Manual Before Operating Device OI-S1100401-401.5 Uncontrolled Document Rev. 6.0-06/23/2006 1

SAPPHIRE SERIES 1100 & 1100EC PLEASE NOTE: It is important that the user read the entire manual before operating this device. USER ASSISTANCE INFORMATION: If you have questions or need assistance with this product, call the company from whom it was purchased, or contact Sunflower Medical L.L.C. at 1-888-321-3382 Table of Contents Page User Assistance 2 General Warnings and Precautions 3 Purposes of the Device 3 Description of the Device 4 Unpacking/Parts Breakdown 4 Operating Instructions 5 Key Pad Quick Reference 7 Mattress and Blower Unit Cleaning 8 Maintenance 9 Storage 9 Troubleshooting 9 Frequently Ordered Parts 10 Return/Exchange Goods Policy 11 Warranty Provisions 11 Technical Description of the Equipment: The two principle components of the Sunflower Medical Sapphire Series 1100 & 1100EC Mattress System are a specialized air inflatable bladder (Air Mattress) and an electrically powered, Air Blower/Control Unit. 2

GENERAL WARNINGS AND PRECAUTIONS WARNINGS WARNING: DO NOT use this device if the power cord is cut, frayed or loosely connected to the device. WARNING: Make sure power cord is plugged into a properly grounded A/C 110V outlet. PRECAUTIONS CAUTION: DO NOT use around an open flame. CAUTION: The housing of the master control unit should only be opened by qualified technical personnel. Before opening the housing, make sure the unit is turned off and unplugged from its power source. CAUTION: Electric Powered Mechanism. Electrical Hazard may occur if device is plugged into inadequate electrical outlet. To avoid electrical shock hazard, make sure unit is plugged into a grounded A/C 110 Volt outlet. PURPOSE OF THE DEVICE The purpose of the Sapphire Series 1100 & 1100EC Mattress System is to provide therapeutic benefit to patients at risk or suffering from pressure ulcers. The active component that has contact with the patient is a specialized, multi-cell air mattress sized to fit a standard medical bed frame. The air mattress serves to replace the original mattress and is equipped with 4 air hoses with connectors that mate with the Air Blower/Control Unit. The Control Unit is a self contained, totally enclosed module that hangs by retractable hooks on the bed frame at the foot of the bed or sits on the floor under the bed. It is provided with a hospital grade electrical cord and a control panel that has selector switches and indicator lights. The switches and indicators are protected under a flexible membrane to keep out liquid spills and enhance clean-up and sanitation. Inside the Control Unit is a variable output blower, a valve motor and air valves that allow the air mattress to operate in static mode or provide alternating pressure variations within the mattress. There is also a printed circuit board, which provides the electrical controls. The Control Unit has one user replaceable 250v 5.0 amp fuse near the AC Power Cord Entry. 3

DESCRIPTION OF THE DEVICE: The Sapphire Series 1100 & 1100EC Mattress Replacement System consists of a control unit, power cord, a Low Air Loss Mattress and a waterproof, vapor permeable, easy-to-clean cover. UNPACKING / PARTS BREAKDOWN: Parts - Air Blower/Control Unit - Power Cord (hospital Grade) - True Low Air Loss Mattress Replacement - Mattress Cover Air Blower/Control Unit and Power Cord True Low Air Loss Mattress and Cover Tools Required: NONE Unpacking instructions: Remove the products from the packing material and examine for shipping damage. If damage is detected in shipping, contact the freight company and file a damage complaint immediately. Directions for Mattress Placement: Replace the existing bed mattress with True Low Air Loss Mattress. Secure Air Mattress to the bed frame with straps provided. Warning or Safety Instructions relating to setup: WARNING: Make sure the power cord is plugged into a properly grounded A/C 110 Volt outlet. 4

1) Remove standard mattress from the bed. Sapphire Series 1100 & 1100EC Operating Instructions: 2) Replace standard mattress with the Sapphire Series 1100 or 1100EC mattress. (Be sure air tubing is at the foot end of the bed.) 3) Strap air support mattress to bed frame on all four sides. 4) Place control unit on the footboard of the bed using the two retractable hooks located on the back of the unit. (If no footboard is available, put blower on the floor away from traffic.) To avoid blocking the air intake, DO NOT lay control unit on its back. CPC 5) Attach the air tubing to the blower unit, being sure it snaps in tight. (Be sure air tubing is not kinked and is unobstructed.) 6) Plug unit into grounded A/C 110 volt outlet. Air Tubing Connection 7) Turn master power switch, located on the side of the unit, on. 8) At this time the control unit will automatically go into static mode. 9) Press the Autofirm button for quick inflation. 10) Placed the patient on the bed after inflation to insure the air cells do not become twisted or kinked. 11) To get the control unit out of Autofirm mode, press Autofirm button again. 12) Static Mode a. Press the Static Mode button b. Set the desired comfort level with the Soft/Firm buttons 5

13) Alternating Mode a. Press the Alternating Mode button b. Set the desired cycle time with Cycle Time buttons (3-20 minutes) c. Set the desired comfort level with the Soft/Firm buttons. 14) Lock-out Feature a. After 3 minutes, if there are no changes to the blower settings, the lockout feature will activate. b. Press and hold the Lock-out button for 5 seconds to disengage the lock-out feature. 15) For quick deflation or for CPR use: a. Turn power off b. Twist CPR plug to open it c. Remove the hoses from the control unit. Notice: The mattress is equipped with a 2-inch foam pad in the mattress base for patient support and transportation. 6

Alternate Enables alternation with pressure sensors regulating airflow. Alternation times are preset at 3 min and can be increased by cycle time. Mode - Press to switch between Alternate and Static operations. Static Enables static low-air-loss therapy. Soft/Firm Settings Firm - Adjusts surface toward firmer level. Increases airflow. Soft - Adjusts surface toward softer level. Decreases airflow. CONTROL PANEL ILLUSTRATION Cycle Time Increases or decrease the time of cycle between 3 to 20 minutes. Refer to this page as needed for quick reference to the control panel functions. Shows control panel layout for the blower unit. Lock-out - Locks out all other functions automatically after 3 minutes or when pressed. Provides individual button illustration and function description. For more detailed directions refer back to the operating instructions starting on page 5. FOR INQUIRIES CALL 1-888-321-3382 AutoFirm - Quickly inflates mattress to maximum firmness. Unit times out after 20 minutes to previous setting. 7

MATTRESS CLEANING INSTRUCTIONS: CAUTION: A. It is recommended that gloves and protective clothing be worn at all times during cleaning and disinfecting B. Hypercarbonate and phenol based solutions should not be used. During Operation: For normal soil, wipe down cover and interior sacs with a standard cleaning disinfectant and wipe off excess moisture with a towel. Laundering Mattress: 1. Disconnect the power and deflate the interior sacs. 2. Disassemble cover, interior sacs, connecting hoses and base. Place them in different laundering baskets. 3. Spray disinfectants and wipe down interior sacs. Air-dry sacs. DO NOT expose to heat. 4. Spray disinfectants and wipe down foam cover. 5. Place cover and base in washing machine. 6. Use standard hospital disinfectant/detergent. 7. Set washing cycles as recommended below: Regular Cycle a) Pre-soak with disinfectant/detergent with diluted bleach in cold water (10 minutes.) b) Main wash for 15 minutes (Time depending on soil level). c) Rinse Cycle: 5 minutes minimum. d) Spin/Drain Cycle: 5 minutes minimum. e) Air-dry or place in dryer at very low or no heat. 8. After the cover, interior sacs, and base are dry, store them in a sterilized bag and seal for next use. Notice: DO NOT use water temperatures greater than 150 F (65 C). BLOWER CLEANING INSTUCTIONS: CAUTION: A. It is recommended that gloves and protective clothing be worn at all times during cleaning and disinfecting B. Hypercarbonate and phenol based solutions should not be used. C. Make sure unit is turned off and unplugged before cleaning. For normal soil, wipe down with a standard cleaning spray and wipe off excess moisture with a towel. Spray with a disinfectant and let it stand for a few minutes before wiping down. Check corners and creases for soil build-up. Look to see if any external parts are damaged or need replacing such as: hooks, foot pads and filter. Replacement parts can be purchased. See last page for parts listing. 8

Maintenance: Foam air filter on the back of the control unit must be cleaned weekly periodically with warm soap and water. Replacement of the foam filter is recommended every 6 months. Storage: Deflate mattress using the CPR valve until all air is exhausted completely. With the cover on, roll the mattress starting at the foot section. Secure with straps and keep mattress in a clean dry area away from heat or flames. The filter is easily removed and reinserted through the gap in the back housing. TROUBLE SHOOTING GUIDE If mattress is not inflating: - Make certain none of the hoses are punctured, kinked or disconnected. - Check for proper connections from the hoses to the pump. Make sure they are secure. - Check or clean intake filters. - Be sure CPR valve is closed. If there is power loss: - Check the ON/OFF switch. - Check to be sure that unit is plugged in. - Check the fuse located just under the power cord plug on the blower unit. 9

Frequently Ordered Parts The following is a list of parts that are frequently ordered for self replacement and repairs. To aid you in ordering parts, please use the provided product numbers given below for each part. The replacement of some parts not listed here may require sending in the unit to the manufacturer for repairs. 96065 Black Connector Connects from mattress to blower unit side panel. Allows air movement to inflate mattress. 95071 Filters Removes dust and other particles from the air as it is pulled into the blower unit. 96064 Male CPC (Chrome) Attached to blower unit side panel. Connects to Female CPC to remove exhaust air from unit to mattress. 96066 Female CPC Connects from mattress to Male CPC on blower unit. Removes exhaust air from unit to mattress. 96055 Power Cords (removable and fixed) Grounded power cord for providing power to the blower unit. 95031 Hooks Collapsible hooks that allow the unit to be hung on bed frame. Brackets Attach the hooks to the bottom case of the unit. N/A 10

Return/Exchange Goods Policy: Return of Goods: 18% Return Charge for a Restocking Fee for returned goods when customer makes a wrong order of items, still in original Packing. A Return Authorization Number (RAN) Form(s) will need to be filled out and processed through the Sunflower Medical LLC Customer Service Department. Once RAN is issued, customer must return all items placed on the RAN within five working days from the date of the RAN to Sunflower Medical LLC. Without an Authorized RAN, all items will be returned to the customer at the customer s expense. Repairs or Replacements are offered for defective items. Also a RAN action must be completed before any repairs or replacements can be completed. Sunflower Medical LLC: Replacement for wrong Items shipped, RAN form must also be completed, and then items will be replaced or repaired at no cost. WARRANTY PROVISIONS: Warranty: Sunflower Medical LLC; Warrants that all products provided under this agreement are free from defects in material and workmanship, for the following stated warranty period from the date of delivery. Sunflower Medical LLC guarantees all purchased equipment to be free from defects in material and workmanship as follows: Control Unit One (1) year; Mattress Two (2) years on air cell welds; One (1) year on Bottom Cover, Manifold & Foam Base; Top Cover Ninety (90) Days. All parts found defective within that period shall be repaired and/or replace, with the cost of repair and/or replacement, to be borne by Sunflower Medical LLC. The warranty is not valid and repairs and/or replacement will not be made free of charge, if the product has been misused or damaged by accident. Sunflower Medical LLC reserves the right to make this determination based upon the condition of product upon time of receipt. 11