Product Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616

Similar documents
Product Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616

Product Tests Report

CERTIFICATE OF ACCREDITATION

STS Directory Accreditation number: STS 0009

DRAFT TANZANIA STANDARD

COMITÉ EUROPÉEN DES ASSURANCES

ANSI-ASQ National Accreditation Board/ACLASS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

64 Max IR Thermometer

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Audible warning devices for external alarm

INTERNATIONAL STANDARD

62 MAX/62 MAX + Infrared Thermometer

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

62 MAX/62 MAX + Infrared Thermometer

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

64 Max IR Thermometer

Procedure for the Approval of New Fire Detection and Alarm Technologies

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CLETEF-786. Infrared Thermometer Instruction Manual

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage

Supplement. Title: 365 Users Supplement Issue: 8 Part Number: Issue Date: 7/16 Print Date: August 2010 Page Count: 6 Revision/Date:

62 MAX/62 MAX + Infrared Thermometer. Users Manual

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

ENVIRONMENTAL TEST REPORT

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CNBOP-PIB Standard Fire Protection

ISO INTERNATIONAL STANDARD. Agricultural engineering Electrical and electronic equipment Testing resistance to environmental conditions

23" PANEL MOUNT INDUSTRIAL MONITOR REVISION C PRODUCT RELIABILITY TEST REPORT

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

Report No 288/ Part 1 of 2 This report consists of 22 pages. Maxitone ZAMT Type A Addressable Sounder. See Assessment Summary for details

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

MT4 MAX/MT4 MAX + Infrared Thermometer

Type approval qualification of Photovoltaic Modules Procedures and test experiences

LC1 Modular Ceiling Loudspeaker Range. en Installation note

This annex is valid from: to Replaces annex dated: Prolonged until

17" UNIVERSAL MOUNT INDUSTRIAL MONITOR REVISION E, F & G PRODUCT RELIABILITY TEST REPORT

62 MAX/62 MAX + Infrared Thermometer

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current. Output Voltage Range

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

62 MAX/62 MAX + Infrared Thermometer. Users Manual

CERTIFICATE of QUALITY TEST

Installation instructions

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

ETSI TS V1.2.1 ( )

S R 8 Circular LED Engine Product Specification

Infrared Flame Detectors

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

QPM21 Series Duct CO 2 and Air Quality Sensors

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 3: Audible alarm devices

/Mar/2014 Rev A

safety & regulatory information

VdS SCHADENVERHÜTUNG. VdS-Rules for Intruder Alarm Systems

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. F2 LABS Peters Road Middlefield, OH Wendy Fuster Phone: Ext.

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

ISO INTERNATIONAL STANDARD

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Pyroelectric Infrared Sensors

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current

TECHNICAL REPORT Crimp Splice Protection -250M/P150 mark 2

EMI/RFI Filters. Motor Protection

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

3kW 6kW, QUBE Fiber Lasers

CERTIFICATE OF ACCREDITATION

Australian Standard. Fire detection and alarm systems. Part 6: Carbon monoxide fire detectors using electro-chemical cells

Electromagnetic compatibility (EMC)

This is a preview - click here to buy the full publication INTERNATIONAL ELECTROTECHNICAL COMMISSION

UN Test Report - ASM P/N 45N1010 (Nom. 94Wh, 11.1V)-

UN Test Report - ASM P/N 45N1028 (Nom. 94Wh, 11.1V)-

Pyroelectric Infrared Sensors

Test Report. Appliance EMF Testing

CERTIFICATE OF ACCREDITATION

E-17 Flammable Gas Detection and Alarm System

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Road vehicles Environmental conditions and testing for electrical and electronic equipment Part 4: Climatic loads

This document is a preview generated by EVS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SpeedDome Ultra Camera Dome Outdoor Housing

MaxiCompressor. Limited Warranty. High Performance 50 PSI Compressor 501-S

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Duct Air Quality Sensors

Type approval testing of miscellaneous smoke and heat detectors for marine applications

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)

Power Factor (2) 350 ma 90 ~ 132 Vac Vdc 35 W 86% 0.95 LLC-040S035RSP. Efficiency (2)

Test Methods for Consideration Into Radio Standard

Enhance DX. Mattress Replacement System. User Manual

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

Transcription:

TO WHOM IT MAY CONCERN Product Test report Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616 Product name: BOSCH FLEXIDOME IP outdoor 4000 HD/IR BOSCH FLEXIDOME IP outdoor 5000 HD/MP/IR Model numbers: Material No. CTN Description F.01U.296.223 NDN-41012-V3 IP Dome 720p IP66 FLEXIDOME IP outdoor 4000 HD F.01U.296.224 NDI-41012-V3 Infrared IP Dome 720p IP66 FLEXIDOME IP outdoor 4000 IR F.01U.296.219 NDN-50022-A3 IP Dome 1080p IP66 AVF FLEXIDOME IP outdoor 5000 HD F.01U.296.220 NDI-50022-A3 Infrared IP Dome 1080p IP66 AVF FLEXIDOME IP outdoor 5000 IR F.01U.296.221 NDN-50051-A3 IP Dome 5M IP66 AVF FLEXIDOME IP outdoor 5000 MP F.01U.296.222 NDI-50051-A3 Infrared IP Dome 5M IP66 AVF FLEXIDOME IP outdoor 5000 IR The above mentioned Bosch Security Systems products have been tested in accordance and were found to comply with the tests listed below which were carried out during the development phase of the product. ENVIRONMENTAL TEST EN50130-5:1999 Alarm systems Part 5: Environmental test methods 1) till 7) is Introduction 8) Dry heat (Operational) IEC60068-2-2:1974 + A1:1993 + A2:1994 9) Dry heat (Endurance) IEC60068-2-2:1974 + A1:1993 + A2:1994 10) Cold operation (Operational) IEC60068-2-1:1990 + A1:1993 + A2:1994 11) Temperature change (Operational) IEC60068-2-14:1984 + A1:1986 12) Damp heat, steady state (Operational) IEC60068-2-2:1988 13) Damp heat, steady state (Endurance) IEC60068-2-3:1969 + A1:1984 14) Damp heat, cyclic (Operational) IEC60068-2-30:1980 + A1:1985 Specific Test description >>class IV, outdoor in general, fixed equipment>> Temp. +70 C (158 F), Duration 16 hours. Temp. +70 C (158 F), Duration 21 days. Temp. -25 C (-13 F), Duration 16 hours. Tested at more severe condition: -40 C (-40 F). Only for portable equipment, no test for fixed equipment. No test for class IV product. Temp. +40 C (104 F), Relative humidity 93%, Duration 21 days. Temp. +25 C~+55 C (77 F~131 F), Relative humidity 93%, 24 hr/cycle, 2 cycles. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany Template: AT18-Q1616 Product Test report version 7.5 Date: 06 Dec. 2007 Page 1 of 5

15) Damp heat, cyclic (Endurance) IEC60068-2-30:1980 + A1:1985 16) Water ingress (Operational) IEC60529 Edition 2.2: 2013 17) Sulphur Dioxide SO 2 (Endurance) IEC60068-2-42:1982 18) Salt mist, cyclic (Endurance) IEC60068-2-52:1996 19) Shock (Operational) IEC60068-2-27:1987 20) Impact (Operational) IEC60068-2-75:1997 21) Free fall (Operational) IEC60068-2-32:1975 + A1:1982 + A2:1990 22) Vibration sinusoidal (Operational) IEC60068-2-6:1995 23) Vibration sinusoidal (Endurance) IEC60068-2-6:1995 24) Simulated solar radiation Temperature rise (Operational) IEC60068-2-5 Edition 2.0: 2010, Procedure A 25) Simulated solar radiation Surface degradation (Endurance) IEC60068-2-5 Edition 2.0: 2010, Procedure C 26) Dust tightness (Endurance) IEC60529 Edition 2.2: 2013 Tested at more severe condition: 6 cycles. Temp. +25 C~+55 C (77 F~131 F), Relative humidity 93%, 24 hr/cycle, 6 cycles. Covered by 14) IEC60529 IPX4 Tested at more severe condition: IPX6 with an installed camera unit (mounted on a board). Sulphur Dioxide 25 ppm, Temp. 25 C (77 F), Relative humidity 93%, Duration 21 days Total 28 days, 4 cycles. Salt mist exposure: NaCl 5%, Temp. +15 C~35 C(59 F~95 F), Duration 2 hr/cycle. Damp heat exposure: Temp. 40 C (-13 F), Relative humidity 93%, Duration 166 hr/cycle. Half sine wave 6 ms, Acceleration = 100G, Shock direction ±X ±Y ±Z, 3 shocks/axis. Impact energy 1.0 Joule, 3 impacts per point Tested at more severe condition: IK10, 20 Joule No test for Fixed equipment Freq. Range 10~150Hz, 5 m/s², X Y Z axes, Sweep rate 1 octave/min, 1 sweep/axis Tested at more severe condition: Freq. Range 10~150Hz, 10 m/s², X Y Z axes, Sweep rate 1 octave/min, 20 sweep/axis Freq. Range 10~150Hz, 10 m/s², X Y Z axes, Sweep rate 1 octave/min, 20 sweep/axis Covered by 22) Temp. +25ºC~+40ºC (77 F~104 F), 2 days 8 hrs irradiation & 16hrs dark per 24hrs cycle Irradiance: 1120W/m² at 300~3000nm Temp. +40ºC (104 F), 10 days 24 hrs irradiation per 24hrs cycle Irradiance: 1120W/m² at 300~3000nm IEC60529 IP6X Page 2 of 5

ADDITIONAL ENVIRONMENTAL FUNCTIONAL BOSCH TESTS Environmental test methods Specific Test description MTBF calculation of used components Based on: Siemens SN 29500, or FIT figures manufacturer. Theoretical MTBF = 895,533 hrs FMEA (failure Mode and Effect Analysis) Design and Process analyses based on Bosch template. HALT (Highly Accelerating Life Test) Overstress test to Fail, Operational, LOL = -40 C (-40 F), HOL = +80 C (176 F), Vibration OL > 50Grms Combined Environment Stress: Temp. -40 C~+80 C (-40 F~176 F), with 4/8/12/16/20/25 Grms for each cycle. Type plate test Rubbing by hand with water and 95% industrial alcohol, Duration 15s. Hot spots on components. With Infra red scanner at room temperature Temp. 25 ±5 C (+77 F). Temperature of Hot spots components With thermocouples at room temperature Temp. 50 ±5 C (+122 F). Bump Non operating Half sine wave, Acceleration 10G, Duration IEC 60068-2-27 Ea 16ms, 1 bump/sec, 1000 bumps/axis, X,Y,Z axes, total 6000 bumps Cold start test At -40 C (-40 F). Transport tests acc. AV18-Q0681 ISTA-2A: 2011 1. Conditioning Pre-conditioning: Temp. +25 C, 43%RH, Duration 6 hours. Conditioning: Temp. +38 C, 85%RH, Duration 72 hours. Temp. +60 C, 30%RH, Duration 6 hours. 2. Compression Top to Bottom, Apply and Hold, Duration 60min. Calculated test load = 972 lbs 3. First vibration test Frequency 232CPM, Duration 62 min. ; Number of Impact (cycle): 14200 cycles 4. Drop test after 1 st vibration test Height depending of weight of product. Drop height (inch): 32; drop times: 10 5. Second vibration test Frequency 232CPM, Duration 62 min. ; Number of Impact (cycle): 14200 cycles Page 3 of 5

Approvals Safety, EMC and Environmental EMC Europe Description EN 55022:2010 / AC:2011 Information Technology Equipment- Radio EN 55024:2010 disturbance characteristics Limits and Methods of measurement. Class B EN 50130-4:2011 Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder and social alarm systems. EN 50121-4:2006 / AC:2008 Railway EMC EN 61000-3-2:2006 + A1:2009 + A2:2009 Mains harmonics Part 3-2: Limits - Limits for harmonic current emissions EN 61000-3-3:2013 Voltage fluctuations Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public lowvoltage supply systems. EMC USA CFR 47 FCC part 15 Class B Conducted + Radiated Emission based on VERIFICATION procedure Australian Product market with BOSCH supplier code AS/NZS CISPR 22 equal to CISPR 22 N663 Japan EMC certification for Japan. VCCI: V-2/2012.04 & V-3/2013.04 Safety Europe EN 60950-1:2006 + A11:2009 + A1:2010 + Information technology equipment Safety A12:2011 + A2:2013 EN 60950-22:2006 + A11:2008 Part 1: General requirements IEC 62471: 2008 (Only for IR version) Eye Safety Safety USA + Canada UL 60950-1 & -22 UL listing + cul listing. First edition dated April CAN/CSA-C22.2 No.E60950-1 & -22 1, 2003. Information technology equipment Safety Part1: General requirements Environmental Prohibited and declarable substances in products, Bosch internal environmental standard. components, materials and preparations. Manufacturer s declaration database based on N 2580-1. Restriction of Hazardous Substances RoHS compliant. Page 4 of 5

The product is produced by a manufacturing organization, which is certified on ISO9001 and ISO14001 standards. Data subject to change without notice. Eindhoven, June 2015. Page 5 of 5