Bevent Rasch RABC-VAV. - Fire /03/2018

Similar documents
Bevent Rasch BSKC6. - Fire /06/17

Bevent Rasch. FIDm. - Fire /11/2018

Bevent Rasch. FIDs. - Fire /05/18

ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

KOMFORT EC DB Suspended heat recovery air handling units

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

TopMaster Air Handling unit. Technical data

AIR HEATING UNIT HEATMASTER ACJB INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

TURBO HOODS. Product Brochure

Fire/Smoke damper EKO-SRBG2

iq Star LYRA II chilled beam cassette

iq Star LYRA II chilled beam cassette

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

Gas-fired unit heaters for indoor installation

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

BSK-RPR Fire Damper. Additional operating instructions according to

... UDSA - UDSBD Gas fired unit heaters...

UV-TURBO HOODS. Product Brochure

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

Orion-LØV LØV-R with Sirius

Fire damper ETPR Instructions for Installation, Operation and Maintenance 10/2016

Fire damper DESIGN GENERAL FIRE CELL DIVISION DISTRIBUTION OF RESPONSIBILITIES FIRE PROTECTION DOCUMENTATION HAGAB FIRE DAMPER DESIGN

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

Orion-Opus LØV-R with Sirius

HOTEL CHILLED BEAM IQ STAR SILENCIA

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

Orion-LØV LØV-R with Sirius

EC Motor Fan Coil Units. IMD-Y Series l/s

Smoke Fire Damper Interface (230V)

TopMaster Air Handling Unit

FAN POWERED VAV TERMINALS

Series VENTS VUT R WH ЕС

ROOFMASTER STEF-HT ROOF FAN

TTC. TTC Active supply air diffuser. Product description. Introduction SUPPLY AIR DIFFUSER - ACTIVE [CEILING MOUNTED] Simplicity

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Smoke Damper Interface (230V)

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

Type TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

SECTION DUCTWORK

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Vibracon LVL-A* Level limit switch for liquids, compact design

Emergency power automatics MS-2. High resistance to shock, vibrations and transients. All output are 2A relay contacts

CONDOR. Supply air ceiling QUICK FACTS

ADRIATIC VF. Active chilled beam with cooling, heating and ventilation QUICK FACTS

CE-marked ESAD - Smoke Control Duct System Installation instructions 08/2013

Orion-PTV LØV-R with Sirius

Multi-Gas-Controller MGC2

Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU

GLEC exhaust FAN. Air Comfort. Air movement. Duct & Box Fans

Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD. Type ADD

Circular Fire Damper Cartridge

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

Ceiling swirl diffusers

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Ceiling swirl diffusers

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

COMPACT Air & Heat. Contents

Bypass Terminal Units. DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) BYPASS TERMINAL UNITS

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

TTC. TTC Active supply air diffuser. Product description SUPPLY AIR DIFFUSER - ACTIVE [CEILING MOUNTED] Introduction. Simplicity

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

THERMA FUSER SIDEWALL LINEAR VAV DIFFUSER

BKA-EN Fire Damper. Additional operating instructions according to

Fire Damper Interface (230V)

5, SE GÅNGHESTER,

! WARNING. Before using product, read and understand instructions.

TECHNICAL SPECIFICATION

Fire dampers. For diverse applications

Ceiling diffusers. Type DLQL

Instructions for the BASIC BCRW Fan, Sizes General

INSTALLATION MANUAL RHF025EE Series RHF035EE Series RHF050EE Series RHF080EE Series RHF100EE Series

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

WORKSHOP VENTILATION- PSYCHROMETRICS-AHU

Installation, operation and maintenance guide for window models

Installation Instructions Exhaust Fan With Light

Fire Damper Interface (24V)

Suxess Compact Top HEALTHY INDOOR ENVIRONMENT WITH ENERGY EFFICIENT VENTILATION

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

ACTIVA SERIES ROOF TOP Air Conditioners 017/040

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

AIR CURTAIN HX RECESSED RANGE

Duct Air Quality Sensors

REVIEW OF TECHNICAL STANDARDS AND CALCULATION METHODS FOR DIMENSIONING OF SMOKE AND HEAT CONTROL SYSTEMS IN CASE OF FIRE IN UNDERGROUND CAR PARKS

VL120. Multi blade smoke evacuation damper 120' C-NT-V24-A 01/2016

IRBB Inert gas damper

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

Control Panel Basics Volume 1

Instructions. Duct Mount Accessory Q Rev: 11/

MANUAL INTELLIVENT CELSIUS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Transcription:

Bevent Rasch - Fire - RABC-VAV 26/03/2018 Fire damper and VAV-damper combined RABC-VAV Fire resistance class E60 Sizes from 100 mm to 630 mm Prefitted safety actuator 24V Installation in ducts Available in MagiCAD CE-marked building product according to 15650:2010 www.bevent-rasch.com

Fire damper RABC-VAV E60 Quick facts Fire resistance class E60 Sizes from 100 mm to 630 mm Prefitted safety actuator 24V Installation in ducts Available in MagiCAD CE-marked building product according to 15650:2010 CE-certified fire damper and VAV-damper combined RABC-VAV is both a CE-certified fire damper E60 and a variabel-/constant flow damper. This combination of two functions solves both fire separation and VAV-flow control in the same damper. This saves both time, space and money when installed in for example hotels, office- and retail complexes, where both functions is needed. RABC-VAV consists of a damper unit, measuring unit, regulator and actuator. Use Combustion gas function CE-certified fire damper preventing combustion gases from spreading where ventilation ducts pass through fire cell separating building elements or for placement after air handling units, serving more than one fire cell. Performance EC certificate according to EN 15650:2010 0402-CPD-SC0058-13 VAV function Variable air volume reduces energy consumption for fans, heating, cooling and reduces filter costs. The dampers are controlled by 2-10V/0-10V signal from for example temperature or CO2 sensors. Max and min air flows or constant air flow is calibrated and verified before delivery. The controll gives an output signal of 2-10V/0-10V depending on air flow. 2-10V is a default setting. To controll the damper by 0-10V, this needs to be stated when ordering. Size Ø100 630 mm. Design RABC-VAV is supplied complete with factory mounted, maintenance-free, 24V electric safety actuator with thermal sensor featuring built-in signal contacts to indicate the damper position. RABC-VAV is prepared to be over insulated 50 mm. Controll signal from regulator giving 2-10V/0-10V DC output. At power failure (fire), the damper closes using the actuator spring return. Material and surface treatment Casing and components of galvanized steel sheet according to environmental class C3. EPDM spiral duct connections. For higher demands on environmental class, the damper can be manufactured in stainless AISI 3041 EN 1.4301 or Stainless AISI 316L EN 1.4404. Classification of fire resistance according to EN 13501-3 E60 (ve ho i < > o) For complete classification, see the Declaration of Performance. 2 BORÅS Tel +46 (0)33-23 67 80 STOCKHOLM Tel +46 (0)8-54 55 12 70

E60 Fire damper RABC-VAV Activation Smoke detectors are verified according to SS-EN 54-7 to activate dampers. The mandatory thermal sensor closes the damper at 72 C according to ISO 10294-4. Control and monitoring When the damper is used to prevent the spread of fire and combustion gases it must be closed via impulses from the smoke detector. This must be fitted in the ventilation duct in the proximity of the damper or in another suitable location. Smoke detectors are monitored by means of Bevent Rasch s MRB system or the like. The MRB monitoring system also performs automatic operating checks on the damper every 48 hours and is designed so that faults are indicated immediately and the damper closes. See www.bevent-rasch.com for further details. The following monitoring units from Bevent Rasch can be used: MRB3 with RCTC/RCTU PLEASE NOTICE: RCTU unit must be factory fitted. Installation RABC-VAV is installed in horizontal or vertical ducts that pass through fire cell separating building elements, according to the adjoining installation instructions. When installed as the termination device, the damper must be fitted with protective grilles. Specification Example: Fire damper RABC-VAV - 250-1 - 1 Size Nom. diameter Ød, mm Connection Spiro = 1 Material Galvanized sheet steel = 1 Stainless AISI 3041 EN 1.4301 = 2 Stainless AISI 316L EN 1.4404 = 3 Note. Factory fitted actuator always included. Accessories MRB3 with RCTC/RCTU RCKD/RCRD TR24-M T-Sense Monitoring & function testing of system with up to 236 dampers. Smoke detectors Room regulator Air quality sensor Actuator In accordance to the certification, RABC-VAV is always supplied with an electric safety actuator 24V with spring return, closed when power off. The actuator has micro switches for closed and open positions. Miscellaneous All data refers to dampers in normal design. Dimensions and weight 500 Ø d max 80 50 Size Ø d A B Weight *) kg 100 316 396 6,2 125 316 396 6,4 160 316 396 6,6 200 316 396 7,6 250 316 396 7,8 315 316 396 9,2 400 435 515 11,2 500 435 515 13 630 500 580 15,6 A B *) Excl. controller and actuator d = Swedish Standard SS 2609 (spiral connection) BORÅS Tel +46 (0)33-23 67 80 STOCKHOLM Tel +46 (0)8-54 55 12 70 3

Fire damper RABC-VAV E60 Air flow areas The diagrams show the relationship between nominal flow and the output signal (U 5 ) for each size. Installation See installation examples. RABC-VAV, size 315-500 RABC-VAV, size 100-250 U 5 V 100% 10 9 Size 100 125 160 200 250 75% 66% of nom. flow 8 7 Example 50% 6 5 33% of nom. flow 25% 4 3 unreliable area 0% 2 0 100 200 300 400 500 Air flow, l/s U 5 V 100% 10 9 75% 8 Size 315 400 500 630 7 50% 25% 0% 6 5 4 3 unreliable area 2 0 500 1000 1500 2000 2500 Air flow, l/s Operation range Size Nom. flow l/s Max. flow l/s Min. flow l/s 100 70 21-70 12-70 125 100 30-100 20-100 160 160 50-160 35-160 200 300 90-300 50-300 250 420 130-420 90-420 315 600 180-600 120-600 400 1000 300-1000 200-1000 500 1530 460-1530 300-1530 630 2490 750-2490 470-2490 Max. adjustable air flow is 30-100% of nom. air flow. With min. air flow below the recommended min. air flow, the measuring uncertainty increases. Example: Prerequisites: Air flow, max. 200 l/s, min. 100 l/s Select size 200. Nom. air flow = 300 l/s Max. air flow (66% of nom. air flow) = 200 l/s Min. air flow (33% of nom. air flow) = 100 l/s (all the above air flows are set at the factory) The min. and max. air flow is always set as a % of nom. air flow. The output signal U 5 is not affected by the V max and V min settings. Vmin Set min. air flow % Vmax 33% of nom. air flow = 100 l/s 40 50 60 30 70 20 80 10 0 V min % 90 100 Vmax l/s 300 200 100 Set max. air flow 66% of nom. air flow = 200 l/s 40 50 30 60 70 80 V max % 90 100 0 2 4 6 8 10 V W control signal The max. air flow can be regulated between 100-30 % of the nom.air flow. 4 BORÅS Tel +46 (0)33-23 67 80 STOCKHOLM Tel +46 (0)8-54 55 12 70

E60 Fire damper RABC-VAV Installation examples Alt. 1. Installation of separate VAV devices The control signal from the room regulator or DUC controls the VAV-device. The actual value signal can be forwarded for external monitoring of the actual flow. Wiring diagram AC 24V DC 24V M w1 DC 2...10V Input. Control signal from room regulator GT Room regulator U 5 DC 2...10V Actual value output 1 2 3 4 5 6 7 VRD3-BT Alt. 2. Supply and exhaust air are controlled in parallel The control signal from the room regulator or DUC, controls the supply air and exhaust air devices in parallel. The air flow for the devices can be set individually. The actual value signal from each device can be forwarded for external monitoring of the actual flow. Wiring diagram AC 24V DC 24V w1 DC 2...10V Input. Control signal from room regulator U 5 DC 2...10V Actual value output M GT Room regulator M 1 2 3 4 5 6 7 VRD3-BT U 5 DC 2...10V Actual value output 1 2 3 4 5 6 7 VRD3-BT Caution! When connecting several VAV-devices to the same transformer, it is important that all system phases are connected to ( ) and all system neutrals are connected T to ( ). In case of alarm and function tests, the 24V supply must be disconnected! BORÅS Tel +46 (0)33-23 67 80 STOCKHOLM Tel +46 (0)8-54 55 12 70 5

M M Fire damper RABC-VAV E60 Alt. 3. The exhaust air is slave controlled by the supply air The control signal from the room regulator or DUC, controls the master device (RABC-VAV master). The slave device (RABC-VAV slave) is controlled by the master device s control signal (U 5 output signal). The slave follows the master. The flow relationship between slave and master is dependent on the set maximum flow of the slave (normally 100%). The actual value signal from each device can be forwarded for external monitoring of the actual flow. Wiring diagram AC 24V DC 24V 1 2 3 4 5 6 7 w1 DC 2...10V U 5 DC 2...10V master VRD3-BT Input. Control signal from room regulator Actual value output master GT Room regulator slave U 5 DC 2...10V Actual value output slave 1 2 3 4 5 6 7 VRD3-BT This option must be made known before delivery of the VAV devices. Alt. 4. Constant supply air flow RABC-VAV maintains a constant flow that is preset at the factory, which is why the damper is not normally controlled by any external control signal. The output signal can be forwarded for external monitoring of the actual flow. RABC- VAV can be mechanically operated for a range of operational alternatives. M Wiring diagram AC 24V DC 24V U 5 DC 2...10V Actual value output 1 2 3 4 5 6 7 VRD3-BT Constant supply air flow, basic or forced flow A timer or monitor controls the supply air device (RABC-VAV) to force the supply air to a constant set max. flow when the room is used. When the room is not in use RABC-VAV works with the basic flow. Wiring diagram AC 24V s Timer EP Function s V min V max 1 2 3 4 5 6 7 VRD3-BT 6 BORÅS Tel +46 (0)33-23 67 80 STOCKHOLM Tel +46 (0)8-54 55 12 70

E60 Fire damper RABC-VAV Electrical data RABC-VAV Sizing, max... 10 VA - BF24-V... Running time; motor opening... 120-300 s spring return, max... approx. 20 s Protection class... IP 54 Power supply... 24V~ ±20%, 6V ±1V (from VRD3), 50/60 Hz - Control signal Y... - Output signal U... Ambient temperature... End position contacts: - load 300 mw... min 1 ma/5v=, max 100 ma/250v~ After exceeding the above values it applies: - load > 300 mw... min 100 ma, max 3 A/250~ Sound level - when regulating... approx. 45 db(a) - with spring return... approx. 62 db(a) VRD3 3,5 VA DC 2-10 V DC 0-10 V (option) DC 2-10 V DC 0-10 V (option) 0-100% U nom. 0 till +50 C Installation An adequately sized straight duct and correct installation are essential for low measuring uncertainty when measuring the flow in a duct. The required straight duct following a bend is shown in the figures below. For other sources of interference such as union pieces, a straight duct of at least 5 x ØD is necessary before the device. NOTE! The measuring tube shall be fitted at 90 to the plane of the bends. Measuring tubes shall not be placed after two 90 bends in prependicular alignment. The duct s nom. diameter = ØD Method error, m 2 = 5%. 2 x ØD Measuring tube ØD 2 x ØD ØD BORÅS Tel +46 (0)33-23 67 80 STOCKHOLM Tel +46 (0)8-54 55 12 70 7

Fire damper RABC-VAV E60 Size chart Size - 100 Size - 125 Size - 160 Size - 200 Size - 250 Size - 315 8 BORÅS Tel +46 (0)33-23 67 80 STOCKHOLM Tel +46 (0)8-54 55 12 70

E60 Fire damper RABC-VAV Sound data Size - 400 Correction of sound power level, L Wok, in octave band L wok = L w + K ok Correction, K ok Size Ø mm Centre frequency Hz 63 125 250 500 1000 2000 4000 8000 100-5 -5-8 -13-21 -29-35 -39 125-6 -6-7 -15-19 -26-36 -27 160-5 -5-8 -14-17 -24-32 -28 200-5 -6-8 -15-21 -24-26 -30 250-4 -7-9 -14-20 -21-23 -23 315-4 -7-11 -15-20 -22-25 -22 400-5 -7-11 -16-20 -23-23 -24 500-3 -9-14 -18-19 -22-29 -25 630-3 -10-16 -20-21 -20-20 -23 Tol. ± db 2 2 2 2 2 2 2 2 Size - 500 Size - 630 BORÅS Tel +46 (0)33-23 67 80 STOCKHOLM Tel +46 (0)8-54 55 12 70 9

Fire damper RABC-VAV E60 Installation instruction Damper s fire resistance class: E60 (ve ho i < > o). EC-certificate 0402-CPD-SC0058-13 Option 1 Option 2 Repair using an approved method that meets the fire class e.g. caulking. Suspension as set out in section 1 Seal with fire stopping sealant, e.g. Intumex AN Repair using an approved method that meets the fire class e.g. caulking. Seal with fire stopping sealant, e.g. Intumex AN Suspension as set out in section 1 Options 1 and 2 1. Secure the damper in the duct and seal with fire stopping sealant, e.g. Intumex AN. 2. Install the duct system according to applicable requirements. Between the damper and the penetrated building element the maximum spacing between hangers is 1500 mm. Use M10 drop rods and cradles or equivalent. 3. Install the thermal sensor with the sensor body in the air stream without obstructing the movement of the damper blade. Minimum distance between dampers must be 100 mm. Minimum distance to joist structure/wall must be 75 mm. No openings between dampers and fire separating building elements. Optional installation of the damper spindle. 12-0528_ENG / March 2018 teamfront.se 10 BORÅS Tel +46 (0)33-23 67 80 STOCKHOLM Tel +46 (0)8-54 55 12 70