Installation Instructions

Similar documents
Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

C7 Series Split System Uncased Indoor Coils

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

Cased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

INSTALLATION INSTRUCTIONS TXV Coils EBU, EBA

INSTALLATION INSTRUCTIONS TXV Coils EBD, EBA

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

Installation Instructions

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

User s Information and Installation Instructions

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

Installation Instructions

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

EVAPORATOR COILS Installation Manual CCG, VCG, MCG M Series Coils

INSTALLATION INSTRUCTIONS TXV Coils EDM, EDD, EDA

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

2/4TXCC037BC3HCA 2/4TXCB042BC3HCA 4TXCC044BC3HCA 2/4TXCC043BC3HCA 2/4TXCB048BC3HCA

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

Cased Aluminum "Convertible" Coils 4TXCB003CC3HC** 4TXCB004CC3HC** 4TXCC005CC3HC** 4TXCC006CC3HC**

Installation Instructions

GAM SERIES INSTALLATION & OPERATING INSTRUCTIONS MULTI-POSITION AIR HANDLER (ELECTRIC HEAT)

TABLE OF CONTENTS INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.

GAW SERIES INSTALLATION & OPERATING INSTRUCTIONS VERTICAL WALL MOUNT AIR HANDLER (ELECTRIC HEAT)

Evaporator Coil. Installation Instructions GENERAL

PL Series Premier Indoor Plenum Coils

INSTALLATION & OPERATING INSTRUCTIONS AAW SERIES VERTICAL WALL MOUNT AIR HANDLER (ELECTRIC HEAT)

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL WARNING WARNING FULL-CASED UPFLOW/COUNTERFLOW FOR COOLING/HEAT PUMPS FULL-CASED MULTI-POSITION FOR COOLING/HEAT PUMPS MODELS: CF

UPFLOW/DOWNFLOW COILS

Evaporator Coil. Installation Instructions GENERAL

Installation Instruction

INSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP

INSTALLATION INSTRUCTIONS

Installation Instructions

NOT DESTROY. PLEASE READ CAREFULLY AND KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.

Upflow/Downflow A-Coil Specifications

User s Information/Installation Instructions

R-410A. Installer s Guide WARNING: 18-GE04D2-5

INSTALLATION MANUAL LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: SAFETY UIM-C-0214

INSTALLATION MANUAL UN-CASED A COILS UPFLOW FOR COOLING/HEAT PUMPS FLEX COILS FOR FIELD INSTALLED TXV MODELS: UC LIST OF SECTIONS LIST OF FIGURES

CBX32MV (HFC-410A) SERIES UNITS

INSTALLATION INSTRUCTIONS

Installer s Guide Convertible Air Handlers 1-1/2 5 Ton

Installation Instructions

INSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP MODELS: TABLE OF CONTENTS LIST OF FIGURES

Installation Instructions

INSTALLATION & OPERATING INSTRUCTIONS AAC & AEC SERIES CEILING MOUNT AIR HANDLER (ELECTRIC HEAT)

INSTALLATION MANUAL LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: SAFETY

INSTALLATION INSTRUCTIONS

EL SERIES INSTALLATION INSTRUCTIONS

Installation Instructions Replacement R-22 A-Coil Model RCTA- 8060

INSTALLATION INSTRUCTIONS

INSTALLER S GUIDE WARNING: TWE-IN-2A 18-GE02D1-3. Convertible 1 ½ - 5 Ton Air Handlers WARNING HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING

RCTA Horizontal Evaporator Coil Installation Instructions

INSTALLATION INSTRUCTIONS FOR RCQD COILS

Installation Instructions

INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER

INSTALLATION GUIDE. AAM and AEM Series - Multi-Position Air Handler (Electric Heat) ! WARNING ! CAUTION. 1. Safety Instruction. 2.

INSTALLATION GUIDE. AEC & AAC Series - Ceiling Mount Air Handler (Electric Heat) 1. Safety Instruction. 2. Introduction !

Fig. 1--Typical Coil Installation

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT

1. Air Handier Specifications Unit Dimensions Installation Requirements... 5 Minimum Ampacity and Maximum Overcurrent Protection...

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHX SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

FG7T (C and L Series)

GBW SERIES INSTALLATION & OPERATING INSTRUCTIONS VERTICAL WALL MOUNT AIR HANDLER (HYDRONIC HEAT)

AVS Series Air Handlers Installation Manual for CLASSIC SERIES SYSTEMS Models SC, SD, and SDH

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS B6VMMX

USER'S MANUAL/INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR / AHE SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

STELLAR 2000 SINGLE PIECE AIR HANDLERS INSTALLATION INSTRUCTION Supersedes: N2Y (795) N2Y (1195)

Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE. GBM Series - Multi-Position Air Handler (Hydronic Heat) 1. Safety Instruction

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

AHG**-0B Series Hydronic Air Handling Units

GFM SERIES INSTALLATION & OPERATING INSTRUCTIONS HIGH EFFICIENCY X13 MULTI-POSITION AIR HANDLER (HYDRONIC HEAT)

INSTALLATION INSTRUCTION

SPLIT-SYSTEM EVAPORATOR BLOWER (AIR COOLED) INSTALLATION INSTRUCTION Supersedes: Nothing N4C-0500

INSTALLATION GUIDE. GBT/GBS Series - Cased/Uncased Ceiling Mount Hydronic Heat Dx Cool Air Handler ! WARNING. 1. Safety Instruction

Cooling/Heat Pump Convertible Air Handlers

INSTALLER'S GUIDE. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

Transcription:

Split System Indoor Coils Installation Instructions! CAUTION: Read the Installation Instructions supplied with furnace/air handler and observe all safety requirements outlined in instructions and/or furnace/air handler markings before proceeding with installation of the coil These instructions are primarily intended to assist qualified individuals experienced in the proper installation of this appliance. Some local and national codes require licensed installation/ service personnel for this type of equipment. Read all instructions carefully before starting the installation.

Table of Contents 1. General Information... 3 2. Coil Specifications... 4 3. Coil Installation... 5 Upflow Furnace Downflow Furnace Horizontal Furnace Horizontal Ready Coils for Horizontal Left Installation Horizontal Ready Coils for Horizontal Right Installation 4. Refrigerant Line Connections... 6 5. Completing the Installation... 7 Condensate Drain Air Filters Close-off Plates and Panels Refrigerant Charging 6. Maintenance and Service... 8 2

1. GENERAL INFORMATION Standard cased coils are designed for upflow/ downflow applications or horizontal applications when used in conjunction with our horizontal drain pan kit (See page 5). Accessory kits are not required for factory ready horizontal coils. Coils are equipped with braze type refrigerant connections for easy installation. Read the installation manual supplied with the outdoor unit for refrigerant line connection procedure, required line sizes, and other information pertaining to the system installation. 1. Make certain that the air delivery of the furnace/air handler is adequate to handle the static pressure drop of the coil, filter, and duct work. 2. Check the orifice size of the coil s expansion device and confirm that it is suitable for application with the intended outdoor unit. NOTE: Some C4 series coils (R-410A refrigerant) employ a thermostatic expansion valve (TXV) as the metering device (See page 4). 3. Where precise forming of the refrigerant lines is required, a copper tubing bender designed for the size lines used is recommended. Avoid sharp bends and contact of the refrigerant lines with metal surfaces. 4. Refrigerant lines should be wrapped with pressure sensitive neoprene or other suitable material where they pass through the raw edges of holes. 5. Coil must be level for proper condensate drainage. NOTE: Optional cooling/heating equipment must be properly sized and installed in accordance with the furnace manufacturer s specifications and approved recommendations. Heating only furnace air circulators may have to be replaced with multi-speed Heating/Cooling blowers to upgrade the air delivery (CFM) when an add-on coil is installed. Refer to Coil Specifications for recommended CFM and allow for pressure drop across the coil and filters. 19 3 /4" A 3/4" H 13 3 /8" 15 5 /8 " 16 5 /8" 20 3 /4" W Figure 1. 3

2. COIL SPECIFICATIONS 060C-C 060C-C 048C-C (5) 050C- 048C- 048C- 042C- 042C- 036C- 036C- 030C- 043C-A 036C-A 036C-A 030C-A 030C-A 024C-A Coil Model (1) 024C-A R - 22 Units Nominal Capacity TUH (2) 24,000 24,000 30,000 30,000 36,000 36,000 43,000 30,000 36,000 36,000 42,000 42,000 48,000 48,000 48,000 48,000 60,000 60,000 Nominal Airflow 900 900 1100 1100 1200 1200 1400 1100 1350 1350 1500 1500 1500 1500 1500 1500 1800 1800 Installed Orifice Size (3) 0.060 0.060 0.063 0.063 0.067 0.067 0.080 0.063 0.067 0.067 0.075 0.075 0.080 0.080 0.080 0.080 0.093 0.093 Width (in.) W 14 1/4 14 1/4 14 1/4 14 1/4 14 1/4 14 1/4 14 1/4 19 3/4 19 3/4 19 3/4 19 3/4 19 3/4 19 3/4 19 3/4 19 3/4 22 1/2 22 1/2 22 1/2 Height (in.) H 20 20 20 26 20 26 26 20 20 26 20 26 20 26 26 20 26 26 Top F 12 7/8 12 7/8 12 7/8 12 7/8 12 7/8 12 7/8 12 7/8 18 3/8 18 3/8 18 3/8 18 3/8 18 3/8 18 3/8 18 3/8 18 3/8 21 1/8 21 1/8 21 1/8 Connections (in.) Liquid Line 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Suction Line 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 7/8 3/4 7/8 7/8 Horizontal Drain Kit 914633-917492 - 917492-914634 917492 917492-917492 - 917492-914634 914633 914634 - Coil Case Adapter (4) - - - - - - - 913963 913963 913963 913963 913963 913963 913963 913963 913964 913964 913964 C4H-X60C- C C4A-X60C- C C4H-X48C- C C4A-X48C- C C4H-X36C- C4A-X36C- C4H-X24C- C4A-X24C- Coil Model (1) (6) R - 410A Units Nominal Capacity TUH (2) 24,000 24,000 36,000 36,000 48,000 48,000 60,000 60,000 Nominal Airflow 900 900 1350 1350 1500 1500 1800 1800 Metering Device TXV TXV TXV TXV TXV TXV TXV TXV (1) Refer to sales specification sheets for Listed/ Certified combinations of equipment and required accessories. (2) Refer to the current ARI Directory for certified ratings of split systems. (3) Orifice size is for 10 SEER systems. Additional orifices may be supplied with the coil. (4) Allows application of larger coil cases to smaller furnace cabinet. (5) This coil is for 4 ton 12 SEER match. (6) An X in the model description designates factory installed TXV. Width (in.) W 19 3/4 19 3/4 19 3/4 19 3/4 22 1/2 22 1/2 22 1/2 22 1/2 Height (in.) H 20 26 26 26 29 29 29 29 Top F 18 3/8 18 3/8 18 3/8 18 3/8 21 1/8 21 1/8 21 1/8 21 1/8 Connections (in.) Liquid Line 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Suction Line 3/4 3/4 7/8 7/8 7/8 7/8 7/8 7/8 Horizontal Drain Kit 917492-914634 - 917188-917188 - Coil Case Adapter (4) 913963 913963 913963 913963 913964 913964 913964 913964 4

3. COIL INSTALLATION! WARNING: Electric furnaces may be connected to more than one supply circuit. Upflow Furnace 1. Disconnect all electrical power to the furnace. 2. If needed, use one of the coil case adapter kits to match the coil to the furnace air discharge opening. Refer to the Coil Specifications Section for proper kit numbers. 3. Install the coil and level it as needed to ensure proper condensate drainage. (See Figure 2) 4. Seal the enclosure as required to minimize air leakage. 5. Connect the refrigerant lines as outlined in the Refrigerant Lines section. Downflow These coils may be installed in downflow applications. Installation of the coils in these applications only require that the furnace and coil cabinets are securely mounted together before setting in place. Fossil fuel applications require coil to be placed in the supply air stream only. Horizontal Standard coils may also be installed in horizontal applications. Installation of the standard coils in these applications only Figure 2. Upflow Furnace Application require that the furnace and coil cabinets are securely mounted together and that a horizontal drain pan kit be installed. Refer to the Specifications Section for proper kit numbers. To Configure Horizontal Ready Coils for Horizontal LEFT Installations: 1) Remove the coil access door. 2) IMPORTANT: Remove the plug from one of the threaded holes in the horizontal drain pan. Completely remove the webbing located in the threaded holes of the horizontal drain pan. If webbing is not removed, the drain will not function properly and ceiling damage may occur. 3) Insert a plug (from the horizontal drain pan) into the open and unused drain hole in the drain pan at the bottom of the unit to block bypass air. 4) Remove the corresponding drain line knockout from the coil access door to allow access to the horizontal drain. 5) Replace the door. NOTE: Install drainpan extension (supplied) on C3H060 models. To Configure Horizontal Ready Coils for Horizontal RIGHT Installations: 1) Remove the coil access door. Unscrew the line-set tube close-off plate from the front left cabinet rail. 2) Slide the coil and drain pan assembly out of the unit. 3) IMPORTANT: Remove the plug from one of the threaded holes in the horizontal drain pan. Completely remove the webbing located in the threaded holes of the drain pan. If webbing is not removed, the drain will not function properly and ceiling damage may occur. 4) Remove the sheet metal hairpin covers (if supplied) from the back of the coil and discard. 5) Place the horizontal drain pan on the opposite side of the coil. On units with 2 sets of knockouts, remove the other set of knockouts in the coil spacing plates and insert support rod. 6) Insert a plug (from the horizontal drain pan) into the open and unused drain hole in the drain pan at the bottom of the unit to block bypass air. 7) Slide the coil and the horizontal drain pan assembly back into the unit. Reattach the tube close off plate. 5

8) Remove the corresponding drain line knockout from the coil access door to allow access to the horizontal drain. 9) Replace the door. Note: All condensate pans have primary and secondary drain connections to meet FHA requirements. If the application is located in or above a living space where damage may result from condensate overflow, a separate 3/4 inch drain must be provided from the secondary drain connection and a secondary drain pan must be installed under the entire unit. Run secondary drain lines to a place where they are noticeable if used. 4. REFRIGERANT LINE CONNECTIONS NOTE Move to instruction step #7 when installing a C4 series (R-410A refrigerant) coil with factory installed TXV valve. NOTE efore proceeding with the connection of refrigerant lines, confirm that the orifice size meets the requirements outlined in the outdoor unit installation manual. Factory-installed orifice sizes are listed in the Specifications section. If the orifice size is incorrect, it should be replaced, following the steps below: 1. Loosen the orifice/distributor body halves by applying two wrenches and squeezing them together, as shown in Figure 3, to turn the assembly nut counter-clockwise. 2. Continue to unscrew the assembly nut to separate it from the distributor body portion. 3. Insert a light-gauge wire hook between the distributor body and the orifice to lift the orifice out of the body. (See Figure 4) Remove the orifice being careful not to scratch either part. 4. Check the actual size of the new orifice (the size is stamped on the side of the orifice). Do not use pin gauges to measure the orifice diameter. Figure 3. Wrenches on Distributor ody and Assembly Nut 6 Figure 4. Removal of Orifice

Figure 5. Orifice Insertion in Distributor ody 5. Insert the new orifice in the distributor body rounded end down as shown in Figure 5. 6. After installing the orifice in the distributor body, realign the assembly nut to the distributor body. Mark a line along both bodies after hand tightening and then tighten an additional 1/4 turn. Caution: Do not overtighten! The misalignment of the two lines will show how much the nut is tightened. If a torque wrench is used, tighten to 10-12 ft. lbs. or 14-16 Nm. Line Connections: 7. Remove the protective caps from the coil and refrigerant line set and also remove the hole grommets and tube close-off insulation from around the tubes. 8. Cut the line set tubing to the proper length. e sure that the tubing has been sized in accordance with the outdoor unit specifications. 9. Inspect both refrigerant lines. The ends of the lines must be round, clean, and free of any burrs. 10. Insert the line set tubes into the coil tube stubs until they bottom out. 11. raze the individual connections with dry nitrogen flowing through the joints to eliminate internal oxidation and scaling. NOTE: On C4 (R-410A refrigerant) models which use a TXV, it is recommended to wrap a wet rag around the sensing bulb located on the suction line while brazing. 12. Check the assembly for leaks with dry nitrogen. 13. On horizontal applications of C4 (R-410A refrigerant) models with TXV valve, reposition the sensing bulb on the suction line so it is in the 10 o'clock to 2 o'clock position on the suction tube. 14. Replace the tube close-off insulation. 5. COMPLETING THE INSTALLATION Condensate Drain:! CAUTION: The indoor coil must be checked to ensure a level installation. Failure to do so may result in improper condensate disposal, causing structural damage, premature equipment failure, or possible personal injury. 1. The coil condensate pan is furnished with 3/4" NPSC drain connections. Use a PVC or similar material fitting to attach the drain line to the pan. The fitting should be hand tightened only. Overtightening may crack the drain pan and cause a condensate leak. 7

2. Connect the drain line and run to a suitable drain avoiding sharp bends and pinching of the line. Install a condensate trap and prime with water. 3. During the system checkout, inspect the drain line and connections to verify proper condensate disposal. Air Filter Air filters are not provided as an integral part of this coil, however, a filter must be installed upstream of the coil and inspected frequently. When the filter becomes clogged with dust or lint, it should be replaced (disposable type) or cleaned (washable type). The filter should be inspected and replaced or cleaned at least twice during the year, generally at the start of each heating and cooling season. Close-Off Plates and Panels Install the necessary air close-off plates around the refrigerant lines and drain line where required. Reinstall all inner and outer panels of the coil case and furnace that were previously removed to install the indoor coil. Refrigerant Charging These cased indoor coils are not factory charged with refrigerant. It will be necessary to evacuate the indoor coil and line set prior to charging. Refer to the outdoor unit installation manual for detailed charges and instructions. 6. MAINTENANCE AND SERVICE! WARNING: Ensure that all electrical power to the furnace and outdoor (condensing) unit is off before performing any maintenance or service on the system. To ensure optimum performance and to minimize possible equipment failure, the following periodic maintenance should be performed on this equipment: 1. The air filter installed with the system should be checked and cleaned or replaced twice per year. 2. Check the coil, drain pan, and condensate drain line for cleanliness at the start of each heating and cooling season. Clean as needed.! CAUTION: Do not operate the system without having a suitable filter in place in the return air duct system. Always replace the filter with the same size and type. INSTALLER: PLEASE LEAVE THESE INSTALLATION INSTRUCTIONS WITH THE HOMEOWNER 708360 708360 708360 (Replaces708360A) O'Fallon, MO Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A. (11/04)