CB X 32 mv

Similar documents
DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal

MERIT SERIES Up Flow / Horizontal

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

DAVE LENNOX SIGNATURE COLLECTION Humiditrol Whole-Home Dehumidification System

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

13 GEP A L P - 1 A

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

icomfort Residential Communicating Control System Equipment Interface Module (EIM)

RGE 13 A T - 1 A

CBX32MV (HFC-410A) SERIES UNITS

C22 Bulletin # October 1993 Supersedes May 1993

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

XC17. DAVE LENNOX SIGNATURE COLLECTION R-410A - SilentComfort Technology. SEER up to to 5 Tons Cooling Capacity - 21,800 to 59,000 Btuh

MERIT Series R-410A. SEER up to HSPF up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016

C22FC Bulletin # October 1993 Supersedes May 1993

LRP14AC. SEER to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Optional Electric Heat - 5 to 20 kw. Residential - R-410A

Heating Capacity - 23,700 to 220,000 Btuh Nominal Add-On Cooling - 2 to 5 Tons WATER HEATING / BOILERS CBWMV. Residential Hot Water Heat Air Handler

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

2 shp 13 lc 1 36 t - 1 a

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

CBX32MV WARNING CAUTION. Service Literature CBX32MV (R410A) SERIES UNITS

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

T P A 120 S 4 S N 1 Y

DAVE LENNOX SIGNATURE COLLECTION PureAir S Air Purification System

ELITE Series Variable Capacity

ELITE SERIES Downflow - High Efficiency Blower Motor

MERIT SERIES Downflow

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Two-Stage Heat - Variable Speed Blower

15CHPX. DAVE LENNOX SIGNATURE COLLECTION Residential - R-410A - Variable Speed Blower

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

ELITE Series Variable Capacity

14 AC x

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

T S A 048 S 4 N 4 1 T

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

Performance and Reliability. CB*, C* and TA* Models

13HPD MERIT SERIES R 22 H E A T P U M P O U T D O O R U N I T S

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

TOUCHSCREEN. COMFORTSENSE Day Programmable Thermostat. 4 Heat / 2 Cool Universal Multi Stage MODEL NUMBER IDENTIFICATION L U FEATURES

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Variable Capacity - Variable Speed Blower

8+* Bulletin No November 1997

T CLASS SPLIT SYSTEM UNITS Standard Efficiency - R-410A - 60 HZ

Air Handlers and Indoor Coils Up to 20 Tons. CB* and C* Models. True performance and rugged durability

DAVE LENNOX SIGNATURE COLLECTION WITH SILENTCOMFORT TECHNOLOGY

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

HIGH EFFICIENCY AIR HANDLER

Bosch BVA Series Air Handler

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ

DUAL ZONE CONTROL PANEL Zone Control For Residential Heating/Cooling Systems

ELITE Series R-410A - Two-Stage Compressor

CONTROLS WI-FI THERMOSTAT. icomfort Wi-Fi Flex Thermostat PRODUCT SPECIFICATIONS

T P A 048 S 4 N 4 1 T

HIGH EFFICIENCY AIR HANDLER

G34M Bulletin #69/ August 2003

Gas Valve. Combustion Air Intake. Supply Air Blower AM30. Typical Applications

DAVE LENNOX SIGNATURE COLLECTION R-410A - Two-Stage Compressor - SilentComfort Technology

HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER

INSTALLATION INSTRUCTIONS

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

Visit us at For the latest technical information,

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

Rheem High Efficiency Air Handler

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

AVPTC Multi-Position, Internal Txv

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

V8MS Mode Selection Box for VRA Heat Recovery - 60HZ

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

AVPTC. Air Handler 1½ to 5 Tons

DuralokPlus Aluminized Steel Heat Exchanger G 32 V

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

T CLASS SPLIT SYSTEM UNITS Standard Efficiency R HZ Bulletin No March 2009 Supersedes April 2008

TECHNICAL SPECIFICATIONS B6VMMX

Transcription:

PRODUCT SPECIFICATIONS AIR HANDLERS CBXMV DAVE LENNOX SIGNATURE COLLECTION R-0A Ready - Multi-Position - Variable Speed Bulletin No. 0 October 0 Supersedes July 0 Nominal Capacity -. to + Tons Optional Electric Heat -. to kw MODEL NUMBER IDENTIFICATION CB X mv - 06-0 - 6-0 Unit Type CB = Air Handler Refrigerant Type X = R-0A Series Configuration MV = Multi-Position, Variable Speed Blower Motor Nominal Cooling Capacity - Tons 08/0 =. to tons 0/00 = to. tons 06 = tons 08 = tons 060 = tons 068 = + tons Minor Revision Number Refrigerant Metering Device = Fixed Orifice = TXV - Bleedport (indoor unit) = TXV - Non-bleedport (indoor unit) = TXV - Non-bleedport (outdoor unit) 6 = TXV - R-0A Non-bleedport (indoor unit) Voltage 0 = 08/0V-60hz-ph

FEATURES Contents Blower Data...9 Dimensions - Downflow...0 Dimensions - Upflow...9 Electrical Data...7 Electric Heat Data... Features... Installation Clearances With Electric Heat...7 Model Number Identification... Optional Accessories...7 Replacement Circuit Breakers...8 Specifications...7 Warranty All covered components - Limited ten years in residential applications, one year in non-residential applications. Refer to Lennox Limited Warranty Certificate included with each unit for additional details. Approvals Tested with matching air conditioners and heat pump units in the Lennox Research Laboratory environmental test room in accordance with AHRI Standard 0/0. Optional electric heaters are rated in accordance with US Department of Energy (DOE) test procedures and Federal Trade Commission (FTC) labeling regulations. Blower performance data according to unit tests conducted in Lennox air test chamber. Air handlers are UL Listed to US and Canadian safety standards and components within are bonded for grounding to meet safety standards for servicing required by CEC and NEC. ISO 900 Registered Manufacturing Quality System. Applications. to + ton nominal sizes. Multi-position (upflow, downflow or horizontal) applications. Applicable to expansion valve systems in R-0A cooling applications and check and expansion valve systems in R-0A heat pump applications. Applicable to Lennox Harmony III zoning system. Wide-range check and expansion valve is factory installed. See bulletins in section Air Conditioners for cooling capacities. See bulletins in section Heat Pump Outdoor Units for cooling and heating capacities. Optional field installed electric heaters available in several sizes for additive heating capacity. Zoning Applications Units can be used with certain zoning systems. Zone control panel MUST be able to interface and communicate with the variable speed motor in the unit. Lennox Harmony III zoning system has this capability. CBXMV / Page B J D G B REFRIGERANT SYSTEM C H Copper Tube/Enhanced Fin Indoor Coil Lennox designed and fabricated twin coils. Assembled in A configuration. I F Provides extra large surface and contact area, excellent heat transfer and low air resistance for maximum efficiency. Precise circuiting for uniform refrigerant distribution. Precisely spaced ripple-edged aluminum fins fitted to durable seamless copper tubes. Fins are strengthened to resist bending and are equipped with collars that grip tubing for maximum contact area. Lanced fins provide maximum exposure of fin surface to air stream. Long life copper tubing is easy to service. Rifled tubing provides superior heat transfer. E Flared shoulder tubing joints and silver soldering provide tight, leakproof joints. Coil thoroughly factory tested under high pressure to insure leakproof construction.

C D E FEATURES REFRIGERANT SYSTEM (CONTINUED) Refrigerant Line Connections Suction (vapor) and liquid lines have sweat connections that extended outside of the cabinet for ease of connection. See dimension drawings for locations. Check and Expansion Valve Furnished For use with R-0A systems. Wide range valve with Chatleff style fitting. Factory installed on all models, internal to cabinet. Cabinet Constructed of heavy-gauge galvanized steel. Completely insulated with thick fiberglass insulation. Pre-painted steel cabinets have mildly textured enamel finish with primer coat on unpainted side of all panels. Units are shipped in one piece but may be disassembled into two separate sections for ease of installation in tight applications. See dimension drawings. Thick rubber gasket between sections of the two piece cabinets provides an air tight seal. No external screw heads on sides of cabinet for tight installations without damage to walls or woodwork. Removable panels provide complete service access. Electrical inlets provided in sides and top of cabinet. See dimension drawings for locations. Low Leakage Cabinet All models have less than % air leakage and meet ANSI/ASHRAE Standard 9-00 Method of Test for Determining the Air Tightness of HVAC Equipment. Multi-Position Capability Shipped for upflow and horizontal right-hand discharge. Quickly converted to downflow or left-hand, horizontal air discharge. Easily converts to downflow position with furnished coil support rails and filter support rack. Dual Position Drain Pans Drain pans designed for upflow, downflow or horizontal applications. Deep, corrosion resistant plastic drain pans have dual pipe drains. See dimension drawings. F G OPTIONS Downflow Combustible Flooring Base Base is required for models with electric heat installed in downflow position on combustible floors. Horizontal Support Frame Kit (Not for -068) Provides support of unit in horizontal applications. Consists of () x -/ x - in. and () x x -7/8 in. painted heavy gauge cold rolled steel support channels with assembly and suspending holes. Bolts and nuts furnished for field assembly. Suspending rods must be field provided. Side Return Unit Stand (Upflow Only, Not for -068) Raises unit 6 in. above floor for side return air duct connection. Eliminates need for wooden platform construction. All aluminum construction. Two adjustable frames fit -08/0 thru -060 models. Wall Hanging Bracket Kit (Upflow Only) Allows unit to be hung on wall at any height. Consists of heavy-gauge steel support brackets (one for air handler, one for wall mount). Screws furnished for fastening one bracket to unit. Bolts for fastening one bracket to wall are field provided. BLOWER Variable-Speed Blower Motor High efficiency multi-speed blower motor maintains specified air volumes up to a maximum of 0.8 in. w.g. total external static. Multi-speed operation is achieved by the use of an ECM (Electronically Commutated Motor) motor. Allows cooling ramping profiles (field selectable) for enhanced dehumidification. Motor accelerates and decelerates gradually, reducing start-up and shut-down sound. Leadless blower motor features simple plug-in connections. Motor is controlled by the icomfort control that allows blower to operate at two of eight air volumes or speeds available. Speeds may be field selected on icomfort control depending on size of air handler and air volume desired. See blower performance tables. Blower Assembly Lennox designed and built, direct drive blower. Each blower is statically and dynamically balanced as an assembly before installation in the unit. Blower motor is resiliently mounted to blower assembly. Blower slides out of cabinet for servicing. CBXMV / Page

H FEATURES CONTROLS icomfort Control Advanced control board communicates information about various operating parameters in the air handler to the optional icomfort Wi-Fi Thermostat to constantly maintain the highest level of comfort, performance and efficiency available. Auto Configuration - On start-up the control board automatically sends a description of the unit to the optional icomfort Thermostat to automatically configure the number of stages and features available. Connections for connecting a conventional heating/ cooling thermostat are also provided on the board. Board also features: Lennox Humiditrol Whole Home Dehumidification System (EDA) compatible. EEPROM storage of all local configurations. Non-volatile memory storage of 00 alarm codes with display of last 0 codes for troubleshooting. Connections for optional outdoor temperature sensor (communicates temperature on RSBUS to thermostat). Controls evaporator humidity by controlling blower and compressor staging on two-stage outdoor units. Two stages - HEAT and COOL (with four different air volume selections for each) are made by simple jumper pins on board. ADJUST jumper pin allows approximately 0% higher, normal or 0% lower motor speed selection within HEAT and COOL speeds selected for fine tuning air volume. DELAY jumper pin allows selection of blower motor de-humidification profiles during cooling mode. Option - Motor runs at 00% of capacity until demand met. Once demand is met, motor ramps down to stop. Option Cooling: When cool demand is initiated, motor ramps up to 00% and runs at 00% until demand is satisfied. Once demand is met, motor runs at 00% for seconds, then ramps down to stop. Heat Pump: When heat pump demand is initiated, 0 second motor on delay starts. After the motor on delays expires, motor ramps up to 00% and runs at 00% until demand is satisfied. Once demand is met, motor runs at 00% for seconds, then ramps down to stop. Option - Motor runs at 8% of capacity for approximately 7. minutes, then 00% capacity (if needed) until demand is satisfied. Once demand is met, motor ramps down to stop. CBXMV / Page Option - Motor runs at 0% capacity for 0 seconds, then 8% capacity for approximately 7. minutes. If demand is not satisfied, motor runs at 00% capacity until demand is met. Once demand is met, motor runs at 0% capacity for 0 seconds, then ramps down to stop. Display LED - Seven segment LED displays alphanumeric information related to diagnostics as well as system operation and status. Diagnostic codes are held in non-volatile memory, immune from power interruptions. Holds up to ten diagnostic codes in order of occurrence for recall on demand. Port on blower door allows for easy viewing. Dehumidification (Active or Humiditrol Option) - A jumper on the control board must be clipped to enable active dehumidification and/or operation with a Humiditrol Whole-Home Dehumidification System. A humidity controlling thermostat or device is also required. During a call for cooling, air volume is automatically reduced, forcing humidity removal by the air conditioner or heat pump system. After the humidity has reached the desired set-point the cooling air volume returns to its designed rate. A dehumidification signal from the thermostat reduces the cooling cfm to 70% of the requested cooling cfm. Electric Heat Operation - Control for up to three electric heat stages. EvenHeater Electric Heat Control - Up to four electric heat stages are available when utilizing the EvenHeater control feature furnished on the icomfort control. EVENHEAT jumper position on control board determines target discharge air temperature of 8 F, 00 F, F or 0 F. Default setting is 8 F. An optional Discharge Air Sensor is required. Heat Pump Operation - A jumper on the control board must be clipped to enable operation with a single or two-stage heat pump. The indoor blower is started without delay when a call for heat is received. Two Stage Cooling Operation - A jumper on the control board must be clipped to enable operation with a two-stage air conditioner. The cooling blower speeds for first and second stage cooling will be dictated by the applicable DIP switch settings. Lennox System Operations Monitor Connection - Monitors outdoor unit operation. (communicating mode). Continuous Blower Speed - Adjustable continuous blower speed is a percentage of the high cooling speed selection. There are four selectable options (via DIP switch settings) of 8%, 8% (default setting), 70% and 00%. Transformer - 70VA transformer furnished as standard. Factory installed in the unit control box. Accessory Terminals - Two accessory terminals are furnished for additional power supply requirements for 0 volt (less than amp) power humidifiers and powered air cleaners. One volt humidifier output is furnished for non-powered humidifiers. Control board is factory installed in the unit control box.

FEATURES CONTROLS (CONTINUED) OPTIONS icomfort Wi-Fi Thermostat (part of the icomfort Residential Communicating Control System) The icomfort Wi-Fi Thermostat recognizes and connects to all icomfort enabled products to automatically configure and control the heating/cooling system (based on user-specified settings) for the highest level of comfort, performance and efficiency. Also recognizes model and serial number information for icomfort -enabled products to simplify system installation. Wi-Fi remote temperature monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets. Service alerts and reminders sent via text message or e-mail. Dealer Dashboard features online real-time monitoring of installed icomfort systems. A simple easy-to-use touchscreen allows complete system configuration. Scheduled maintenance alerts, system warnings and troubleshooting are also displayed on thermostat screen. Easy to read 7 inch color screen (measured diagonally). Conventional outdoor units (not icomfort -enabled) can easily be added and controlled by the icomfort Wi-Fi Thermostat. Installer setup screens allow quick and simple system configuration without a manual, Installer can also run tests on complete system or individual components for easy maintenance and troubleshooting. Serial communications bus (RSBus), with less wiring than a conventional heating/cooling system, allows system communication. Uses -wire, 8-gauge standard thermostat wiring. See the icomfort Wi-Fi Thermostat Product Specifications bulletin in the Controls section for more information. ComfortSense 7000 Touchscreen Thermostat Electronic 7-day, universal, multi-stage, programmable, touchscreen thermostat. Heat/ Cool. Auto-changeover. Controls humidity during cooling mode. Offers enhanced capabilities including humidification / dehumidification / dewpoint measurement and control, Humiditrol control, and equipment maintenance reminders. Easy-to-use, menu driven thermostat with a back-lit, LCD touchscreen. Remote outdoor temperature sensor (optional) allows the thermostat to display outdoor temperature. Required in dual-fuel and Humiditrol applications. See the ComfortSense 7000 Product Specifications bulletin in the Controls section for more information. Outdoor Temperature Sensor Used with icomfort thermostats and ComfortSense 7000 thermostat. When installed outdoors, sensor allows thermostat to display outdoor temperature. Sensor is auto-detected when connected to thermostat. NOTE - Sensor is required for Humiditrol applications. Thermostat Thermostat (icomfort thermostats or programmable/ non-programmable) is not furnished with unit. See Thermostat bulletins in Controls Section and Lennox Price Book for selection. Hot Water Heat Kit INDOOR RH 6% WED AN :AM Air handler kit to control a third-party hot water boiler with a hot water heating coil installed downstream from the air handler. Kit contains all necessary relays and plug-in wiring harness to control boiler. NOTE - This kit is only approved for use in systems using either the ComfortSense 7000 or icomfort -enabled thermostats. MODE SCHED HOME SCHEDULE OPTIONS AUTO ON SET AT HEAT SET AT COOL CBXMV / Page

I FEATURES OPTIONAL Electric Heat Field install internal to unit cabinet. Available in several voltages and kw sizes. See Electric Heat tables. Helix wound nichrome heating elements exposed directly in air stream resulting in instant heat transfer, low element temperatures and long service life. Each element equipped with accurately located limit control with fixed temperature off setting and automatic reset. Supplemental thermal cutoff limit control, provides positive protection in case of excessive temperatures. Thermal sequencer relay brings elements on and off line, in sequence and equal increments, with time delay between each. Initiates and terminates blower operation. Heating control relay(s) furnished as standard. Control box and access cover constructed of heavy gauge galvanized steel. Factory assembled with controls installed and wired. Electric heat low voltage controls plug-in to air handler. Circuit Breaker Models The following heaters are equipped with circuit breakers for overload and short circuit protection: ECB0-CB, -CB, -6CB, -8CB, -9CB, -.CB, -CB, -0CB and -CB (08/0V-ph) ECB0-CB, -0CB and -CB (08/0V-ph Factory wired and mounted on electric heat unit. Current sensitive and temperature actuated. Manual reset. Circuit breakers qualify as disconnect means at unit in many areas, eliminate the need for field provided disconnect. Consult local electrical code in your area. OPTIONS Circuit Breaker Cover Kit Flexible plastic cover protects circuit breaker. Recommended in areas with high humidity or unconditioned areas to prevent nuisance tripping. Single-Point Power Source Control Box Control Box may be used with optional electric heat when single power supply is connected to multi-circuit electric heat. Field installs external to the unit cabinet on either side or top. Constructed of heavy gauge steel, baked enamel finish, prepunched mounting holes, electrical inlet knockouts, and terminal strip. Removable cover provides easy access. Dimensions (H x W x D) - 7 x 7 x in. J INDOOR AIR QUALITY Air Filter Tool-less access to filter area for quick and easy servicing. Disposable frame type filter furnished and factory installed in rails in cabinet. See Specifications tables for sizes. OPTIONS Healthy Climate Germicidal UVC Light Germicidal lamp emits C-Band ultra-violet (UVC) energy at.7 nanometers, which is proven to be effective in reducing microbes such as viruses, bacteria, yeasts, and molds. This process either destroys the organism or controls its ability to reproduce. UVC germicidal light greatly reduces the growth and proliferation of mold and other bioaerosols (bacteria and viruses) on illuminated surfaces (particularly coil and drain pan). Surfaces must be cleaned prior to UVC light being installed. Available in volt and 0/0V-ph models. Air handlers have a factory provided knockout in the coil delta plate for mounting light within coil area. Shielding baffle is required when installing light above a non-uvc resistant component, such as a filter. Baffle must be ordered separately. CBXMV / Page 6

SPECIFICATIONS General Data Model Number CBXMV-08/0 CBXMV-0/00 CBXMV-06 Connections in. Indoor Coil Nominal tonnage. to to. Refrigerant R-0A R-0A R-0A Suction / vapor (o.d.) line - sweat / / Liquid line (o.d.) - sweat /8 /8 /8 Condensate drain - in. (fpt) () / () / () / Net face area - ft..6..0 Tube outside diameter - in. /8 /8 /8 Number of rows Fins per inch Blower Data Wheel nominal diameter x width - in. 0 x 7 0 x 8 0 x 8 Motor output - hp / / / Filters Number and size - in. () x 0 x () 0 x 0 x () 0 x 0 x Shipping Data - Package - lbs. 6 8 ELECTRICAL DATA CONTROLS Voltage - phase - 60hz 08/0V-ph 08/0V-ph 08/0V-ph Maximum overcurrent protection (unit only) Minimum circuit ampacity (unit only) icomfort Wi-Fi Thermostat 88W8 88W8 88W8 Remote Outdoor Sensor (for dual fuel and Humiditrol ) X68 X68 X68 Discharge Temperature Sensor 88K8 88K8 88K8 ComfortSense 7000 Thermostat Y09 Y09 Y09 Remote Outdoor Sensor (for dual fuel and Humiditrol ) X68 X68 X68 OPTIONAL ACCESSORIES - order separately Circuit Breaker Cover Kit 8W0 8W0 8W0 Downflow Combustible Flooring Base J7 K K Electric Heat Healthy Climate Germicidal Light See Electric Heat Data tables UVC-V (V) X9 X9 X9 Shielding Baffle (required) Y7 Y7 Y7 UVC-W-S (0/0v- ph) X9 X9 X9 Shielding Baffle (required) Y7 Y7 Y7 Horizontal Support Frame Kit 6J8 6J8 6J8 Hot Water Heat Kit 90W8 90W8 90W8 Side Return Unit Stand (Upflow) K K K Single-Point Power Source Control Box H9 H9 H9 Wall Hanging Bracket Kit (Upflow) K0 K0 K0 Disposable frame type filter. HACR type circuit breaker or fuse. Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Remote Outdoor Sensor may be used with an icomfort -enabled outdoor unit for a secondary (alternate) sensor reading. Sensor may also be used with a conventional outdoor unit. Optional for EvenHeater electric heat operation and service diagnostics. INSTALLATION CLEARANCES WITH ELECTRIC HEAT Cabinet To Plenum To Outlet Duct within feet (9 mm) 0 inch (0 mm) inch ( mm) inch ( mm) Floor See Note # Service / Maintenance See Note # Units installed on combustible floors in the downflow position with electric heat require optional downflow combustible flooring base. Front service access - inches (60 mm) minimum. NOTE - If cabinet depth is more than inches (60 mm), allow a minimum of the cabinet depth plus inches ( mm). CBXMV / Page 7

SPECIFICATIONS General Data Model Number CBXMV-08 CBXMV-060 CBXMV-068 Nominal tonnage + Refrigerant R-0A R-0A R-0A Connections in. Indoor Coil CBXMV / Page 8 Suction / vapor (o.d.) line - sweat 7/8 7/8 -/8 Liquid line (o.d.) - sweat /8 /8 /8 Condensate drain - in. (fpt) () / () / () / Net face area - ft. 7. 7. 7.77 Tube outside diameter - in. /8 /8 /8 Number of rows Fins per inch Blower Data Wheel nominal diameter x width - in. x 9 x 9 x 9 Motor output - hp Filters Number and size - in. () 0 x x () 0 x x () 0 x x Shipping Data - Package - lbs. ELECTRICAL DATA Voltage - phase - 60hz 08/0V-ph 08/0V-ph 08/0V-ph Maximum overcurrent protection (unit only) 0 0 0 Minimum circuit ampacity (unit only) CONTROLS icomfort Touch Communicating Thermostat 9W9 9W9 9W9 Remote Outdoor Sensor (for dual fuel and Humiditrol ) X68 X68 X68 Discharge Temperature Sensor 88K8 88K8 88K8 ComfortSense 7000 Thermostat Y09 Y09 Y09 Remote Outdoor Sensor (for dual fuel and Humiditrol ) X68 X68 X68 OPTIONAL ACCESSORIES - order separately Circuit Breaker Cover Kit 8W0 8W0 8W0 Downflow Additive Base K K K Electric Heat See Electric Heat Data tables Healthy Climate Germicidal Light UVC-V (V) X9 X9 X9 Shielding Baffle (required) Y7 Y7 Y7 UVC-W-S (0/0v- ph) X9 X9 X9 Shielding Baffle (required) Y7 Y7 Y7 Horizontal Support Frame Kit 6J8 6J8 N/A Hot Water Heat Kit 90W8 90W8 90W8 Side Return Unit Stand (Upflow) K K N/A Single-Point Power Source Control Box H9 H9 H9 Wall Hanging Bracket Kit (Upflow) K0 K0 K0 Disposable frame type filter. HACR type circuit breaker or fuse. Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Remote Outdoor Sensor may be used with an icomfort -enabled outdoor unit for a secondary (alternate) sensor reading. Sensor may also be used with a conventional outdoor unit. Optional for EvenHeater electric heat operation and service diagnostics. REPLACEMENT CIRCUIT BREAKERS Voltage Description Catalog No. 08/0V - Phase amp, pole K 0 amp, pole 7K70 amp, pole 7K07 0 amp, pole 9K amp, pole 7K7 0 amp, pole K 60 amp, pole 7K7 08/0V - Phase 0 amp, pole 6W7 amp, pole K 0 amp, pole K6 amp, pole 8M86 0 amp, pole K 60 amp, pole K7

BLOWER DATA CBXMV-08/0 BLOWER PERFORMANCE 0 through 0.80 in. w.g. External Static Pressure Range ADJUST Setting HEAT Speed COOL Speed cfm cfm cfm cfm cfm cfm cfm cfm + 7 8 000 0 6 690 900 00 NORM 670 770 900 0 60 8 90 80 700 800 90 8 60 7 80 NOTES - The effect of static pressure, filter and electric heater resistance is included in the air volumes listed. First stage cooling air volume is 70% of COOL speed setting. Continuous fan speed is approximately 8%, 8%, 70% and 00% ( selectable) of the same second-stage COOL speed selected, minimum 0 cfm. Lennox Harmony III Zone Control applications - minimum blower speed is 0 cfm. CBXMV-08/0 BLOWER MOTOR WATTS AT + (Plus) SETTING ( Adjust at + Setting) 0 0. 0. 0. 0. 0. 0.6 0.7 0.8 HEAT Speed Tap 00 6 7 90 06 0 Tap 76 97 7 60 78 9 0 Tap 7 60 89 0 7 6 7 90 Tap 8 6 79 09 7 7 6 06 COOL Speed Tap 6 7 6 7 8 9 06 8 Tap 89 0 8 9 6 77 97 07 Tap 8 98 9 8 66 90 07 7 Tap 66 9 0 9 7 90 0 AT NORM SETTING ( Adjust at NORM Setting) 0 0. 0. 0. 0. 0. 0.6 0.7 0.8 HEAT Speed Tap 77 96 06 0 0 6 78 0 Tap 8 6 77 89 7 6 Tap 8 98 8 6 8 07 Tap 6 8 00 6 67 8 06 90 COOL Speed Tap 0 6 76 86 9 06 Tap 7 8 0 8 6 66 8 Tap 7 8 76 99 9 8 7 96 Tap 9 7 9 8 67 AT (Minus) SETTING ( Adjust at Setting) 0 0. 0. 0. 0. 0. 0.6 0.7 0.8 HEAT Speed Tap 9 7 89 06 0 6 7 Tap 9 06 8 6 7 8 00 Tap 8 7 86 8 66 8 Tap 9 7 9 8 0 6 9 COOL Speed Tap 7 7 9 7 77 88 9 06 Tap 7 6 8 9 0 9 8 66 Tap 0 7 76 88 Tap 8 70 9 07 0 8 7 8 06 CBXMV / Page 9

BLOWER DATA CBXMV-0/00 BLOWER PERFORMANCE 0 through 0.80 in. w.g. External Static Pressure Range ADJUST Setting HEAT Speed COOL Speed cfm cfm cfm cfm cfm cfm cfm cfm + 800 9 070 0 660 880 00 0 NORM 7 80 97 00 600 800 000 00 6 76 880 990 0 70 900 080 NOTES - The effect of static pressure, filter and electric heater resistance is included in the air volumes listed. First stage cooling air volume is 70% of COOL speed setting. Continuous fan speed is approximately 8%, 8%, 70% and 00% ( selectable) of the same second-stage COOL speed selected, minimum 0 cfm. Lennox Harmony III Zone Control applications - minimum blower speed is 0 cfm. CBXMV-0/00 BLOWER MOTOR WATTS AT + (Plus) SETTING ( Adjust at + Setting) 0 0. 0. 0. 0. 0. 0.6 0.7 0.8 HEAT Speed Tap 6 90 0 8 0 0 0 7 Tap 9 0 8 0 6 0 6 Tap 0 90 0 90 0 0 0 0 Tap 0 8 0 90 0 80 0 COOL Speed Tap 60 90 0 0 6 8 00 Tap 80 0 6 0 0 8 Tap 0 9 60 9 0 70 6 Tap 6 0 00 0 8 60 AT NORM SETTING ( Adjust at NORM Setting) 0 0. 0. 0. 0. 0. 0.6 0.7 0.8 HEAT Speed Tap 0 7 00 80 9 0 Tap 80 0 0 00 6 9 0 Tap 0 0 7 00 7 0 0 90 Tap 0 0 70 90 60 0 60 COOL Speed Tap 0 80 0 0 0 0 6 80 Tap 6 90 0 90 0 0 60 8 Tap 0 7 0 0 8 70 0 Tap 00 7 00 8 0 70 AT (Minus) SETTING ( Adjust at Setting) 0 0. 0. 0. 0. 0. 0.6 0.7 0.8 HEAT Speed Tap 6 90 0 0 0 6 90 9 Tap 60 8 0 7 00 0 Tap 8 0 0 6 0 80 0 0 Tap 7 0 0 80 70 90 COOL Speed Tap 0 0 70 90 00 0 6 Tap 7 00 8 90 0 Tap 8 7 0 9 0 Tap 7 80 0 0 CBXMV / Page 0

BLOWER DATA CBXMV-06 BLOWER PERFORMANCE 0 through 0.80 in. w.g. External Static Pressure Range ADJUST Setting HEAT Speed COOL Speed cfm cfm cfm cfm cfm cfm cfm cfm + 0 900 80 NORM 0 00 80 7 00 00 8 00 6 70 000 6 NOTES - The effect of static pressure, filter and electric heater resistance is included in the air volumes listed. First stage cooling air volume is 70% of COOL speed setting. Continuous fan speed is approximately 8%, 8%, 70% and 00% ( selectable) of the same second-stage COOL speed selected, minimum 0 cfm. Lennox Harmony III Zone Control applications - minimum blower speed is 0 cfm. CBXMV-06 BLOWER MOTOR WATTS AT + (Plus) SETTING ( Adjust at + Setting) 0 0. 0. 0. 0. 0. 0.6 0.7 0.8 HEAT Speed Tap 0 6 90 0 60 8 6 Tap 8 0 0 80 0 0 0 7 Tap 6 0 0 8 70 Tap 70 9 0 60 7 9 60 COOL Speed Tap 90 0 80 9 0 0 0 Tap 6 90 0 0 70 9 0 Tap 0 0 90 0 7 0 Tap 70 9 0 60 7 9 60 AT NORM SETTING ( Adjust at NORM Setting) 0 0. 0. 0. 0. 0. 0.6 0.7 0.8 HEAT Speed Tap 8 0 6 8 00 Tap 70 9 70 90 Tap 7 90 0 7 00 0 6 Tap 0 7 0 60 8 0 COOL Speed Tap 00 0 0 0 8 90 0 0 Tap 60 90 0 0 6 90 0 0 6 Tap 70 9 0 7 00 0 Tap 0 7 0 60 8 0 AT (Minus) SETTING ( Adjust at Setting) 0 0. 0. 0. 0. 0. 0.6 0.7 0.8 HEAT Speed Tap 0 6 8 0 6 00 Tap 0 6 9 70 00 Tap 8 0 0 6 8 0 0 60 8 Tap 90 0 80 0 0 COOL Speed Tap 6 90 0 60 8 90 Tap 0 0 60 8 7 9 Tap 60 90 0 7 9 0 0 80 Tap 90 0 80 0 0 CBXMV / Page

BLOWER DATA CBXMV-08 and cbxmv-060 BLOWER PERFORMANCE 0 through 0.80 in. w.g. External Static Pressure Range ADJUST Setting HEAT Speed COOL Speed cfm cfm cfm cfm cfm cfm cfm cfm + 80 960 090 0 6 80 0 NORM 70 800 900 00 6 80 00 60 6 70 770 0 7 7 NOTES - The effect of static pressure, filter and electric heater resistance is included in the air volumes listed. First stage cooling air volume is 70% of COOL speed setting. Continuous fan speed is approximately 8%, 8%, 70% and 00% ( selectable) of the same second-stage COOL speed selected, minimum 0 cfm. Lennox Harmony III Zone Control applications - minimum blower speed is 0 cfm. CBXMV-08 and cbxmv-060 BLOWER MOTOR WATTS AT + (Plus) SETTING ( Adjust at + Setting) 0 0. 0. 0. 0. 0. 0.6 0.7 0.8 HEAT Speed Tap 0 0 8 60 66 70 7 780 Tap 9 6 67 70 780 80 86 89 Tap 680 70 770 80 86 900 9 98 00 Tap 70 780 8 870 90 970 00 0 0 COOL Speed Tap 00 70 60 6 00 7 Tap 7 00 8 6 670 70 7 Tap 6 660 70 7 80 80 88 90 970 Tap 700 70 800 8 89 90 990 00 080 AT NORM SETTING ( Adjust at NORM Setting) 0 0. 0. 0. 0. 0. 0.6 0.7 0.8 HEAT Speed Tap 60 8 6 9 6 600 6 Tap 00 0 8 0 9 60 670 70 Tap 80 0 60 60 60 68 76 78 80 Tap 80 6 66 70 760 800 8 87 9 COOL Speed Tap 7 9 0 60 00 0 6 Tap 0 7 0 0 6 00 0 6 Tap 90 6 60 60 67 7 Tap 80 60 6 69 70 78 80 870 90 AT (Minus) SETTING ( Adjust at Setting) 0 0. 0. 0. 0. 0. 0.6 0.7 0.8 HEAT Speed Tap 6 0 0 70 0 0 60 0 0 Tap 0 0 9 0 0 7 80 Tap 7 0 70 7 60 6 Tap 00 80 9 60 670 700 COOL Speed Tap 0 70 9 0 7 00 60 Tap 00 0 60 8 8 0 Tap 80 0 80 6 0 0 Tap 7 0 0 7 0 7 60 6 CBXMV / Page

BLOWER DATA CBXMV-068 BLOWER PERFORMANCE 0 through 0.80 in. w.g. External Static Pressure Range ADJUST Setting HEAT Speed COOL Speed cfm cfm cfm cfm cfm cfm cfm cfm + 87 97 090 0 60 80 07 0 NORM 760 8 90 00 6 6 800 000 0 60 7 800 0 90 60 70 NOTES - The effect of static pressure, filter and electric heater resistance is included in the air volumes listed. First stage cooling air volume is 70% of COOL speed setting. Continuous fan speed is approximately 8%, 8%, 70% and 00% ( selectable) of the same second-stage COOL speed selected, minimum 0 cfm. Lennox Harmony III Zone Control applications - minimum blower speed is 0 cfm. CBXMV-068 BLOWER MOTOR WATTS AT + (Plus) SETTING ( Adjust at + Setting) 0 0. 0. 0. 0. 0. 0.6 0.7 0.8 HEAT Speed Tap 6 0 9 60 660 7 790 Tap 0 8 0 90 60 690 76 8 86 Tap 0 8 6 69 70 800 8 80 86 Tap 66 70 7 770 790 80 80 8 870 COOL Speed Tap 90 0 6 0 0 90 Tap 90 7 80 60 69 70 Tap 0 6 60 70 7 790 8 8 86 Tap 7 7 7 770 790 80 80 80 870 AT NORM SETTING ( Adjust at NORM Setting) 0 0. 0. 0. 0. 0. 0.6 0.7 0.8 HEAT Speed Tap 0 8 6 0 60 60 66 Tap 8 0 60 00 60 6 680 7 Tap 8 0 80 80 60 69 70 8 Tap 7 60 6 660 70 78 8 80 COOL Speed Tap 80 0 0 8 6 0 80 Tap 0 8 0 0 0 8 Tap 7 60 0 60 60 670 7 Tap 0 60 9 66 7 790 8 86 AT (Minus) SETTING ( Adjust at Setting) 0 0. 0. 0. 0. 0. 0.6 0.7 0.8 HEAT Speed Tap 8 7 60 9 0 Tap 9 70 0 60 0 80 Tap 9 0 7 9 9 600 660 Tap 70 00 0 0 600 660 70 COOL Speed Tap 0 70 0 70 00 0 70 Tap 60 8 00 6 0 Tap 80 0 70 0 60 0 Tap 90 00 90 9 60 CBXMV / Page

ELECTRIC HEAT DATA - CBXMV-08/0 SINGLE PHASE. kw lbs. kw lbs. kw lbs. 6 kw lbs. 8 kw lbs. 9 kw lbs. Model Number ECB0-. (W86) ECB0- (W89) ECB0-CB (W90) 0A Circuit breaker ECB0- (W87) ECB0-CB (W90) A Circuit breaker EB0-6 (W88) ECB0-6CB (W9) 0A Circuit breaker ECB0-8 (W89) ECB0-8CB (W9) 0A Circuit breaker ECB0-9CB (W9) 60A Circuit breaker No. of Stages Volts Input kw Input Btuh Input Blower Motor Full Load Amps Minimum Circuit Ampacity Maximum Overcurrent Protection 08.9 6,00.0 6 0 0. 7,00.0 7 0 0. 7,800.0 8 0 0. 8,00.0 8 0 08.0 0,0.0 0.,0.0 0.7,0.0 0.0,60.0 6 0 08.8,800.0 8 0 0.,00.0 9 0 0.6,700.0 0 0 0.0 7,00.0 08.,00.0 0.0 7,00.0 0. 8,800.0 0 6.0 0,00.0 6 0 08 6.0 0,00.0 0 6.7,900.0 0 7.,00.0 0 8.0 7,00.0 7 0 08 6.8,00.0 6 0 0 7.6,800.0 8 0 0 8. 8,00.0 0 60 0 9.0 0,700.0 60 NOTE - Circuit Minimum Circuit Ampacity includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 6. HACR type circuit breaker or fuse. CBXMV / Page

ELECTRIC HEAT DATA - CBXMV-0/00 SINGLE PHASE kw lbs. kw lbs. 6 kw lbs. 8 kw lbs. 9 kw lbs.. kw 0 lbs. kw lbs. Model Number ECB0- (W89) ECB0-CB (W90) 0A Circuit breaker ECB0- (W87) ECB0-CB (W90) A Circuit breaker EB0-6 (W88) ECB0-6CB (W9) 0A Circuit breaker ECB0-8 (W89) ECB0-8CB (W9) 0A Circuit breaker ECB0-9CB (W9) 60A Circuit breaker ECB0-.CB (W9) () 0A and () A Circuit breaker ECB0-CB (W9) () A and () 60A Circuit breaker No. of Stages Volts Input kw Input Btuh Input Blower Motor Full Load Amps Minimum Circuit Ampacity Maximum Overcurrent Protection CkT Ckt CkT Ckt Single Point Power Source Minimum Circuit Ampacity Maximum Overcurrent Protection 08.0 0,0.0 - - - - - - - - - - - - 0.,0.0 - - - - - - - - - - - - 0.7,0.0 - - - - - - - - - - - - 0.0,60.0 6 - - - 0 - - - - - - - - - 08.8,800.0 8 - - - 0 - - - - - - - - - 0.,00.0 9 - - - 0 - - - - - - - - - 0.6,700.0 0 - - - 0 - - - - - - - - - 0.0 7,00.0 - - - - - - - - - - - - 08.,00.0 - - - - - - - - - - - - 0.0 7,00.0 - - - - - - - - - - - - 0. 8,800.0 - - - - - - - - - - - - 0 6.0 0,00.0 6 - - - 0 - - - - - - - - - 08 6.0 0,00.0 - - - - - - - - - - - - 0 6.7,900.0 - - - - - - - - - - - - 0 7.,00.0 - - - - - - - - - - - - 0 8.0 7,00.0 7 - - - 0 - - - - - - - - - 08 6.8,00.0 6 - - - 0 - - - - - - - - - 0 7.6,800.0 8 - - - 0 - - - - - - - - - 0 8. 8,00.0 0 - - - 60 - - - - - - - - - 0 9.0 0,700.0 - - - 60 - - - - - - - - - 08 9.,000.0 8 0 6 70 0 0.,800.0 0 0 6 70 0. 9,00.0 6 0 68 70 0.,600.0 7 0 7 80 08. 8,00.0 8 0 7 80 0.6,000.0 9 8 0 0 77 80 0.8 7,000.0 0 0 0 0 80 80 0.0,00.0 60 8 90 NOTE - Circuit Minimum Circuit Ampacity includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 6. HACR type circuit breaker or fuse. CBXMV / Page

ELECTRIC HEAT DATA - CBXMV-06 Model Number SINGLE PHASE kw ECB0- (W89) lbs. ECB0-CB (W90) A Circuit breaker kw lbs. 6 kw lbs. 8 kw lbs. 9 kw lbs.. kw 0 lbs. kw lbs. 0 kw 9 lbs. ECB0- (W87) ECB0-CB (W90) A Circuit breaker ECB0-6 (W88) ECB0-6CB (W9) 0A Circuit breaker ECB0-8 (W89) ECB0-8CB (W9) 0A Circuit breaker ECB0-9CB (W9) 60A Circuit breaker ECB0-.CB (W9) () 0A and () A Circuit breaker ECB0-CB (W9) () A and () 60A Circuit breaker ECB0-0CB (W96) () 60A Circuit breaker THREE PHASE 8 kw ECB0-8 (W98) lbs. 0 kw 6 lbs. kw lbs. 0 kw 9 lbs. ECB0-0 (W99) ECB0-CB (W00) 0A Circuit breaker ECB0-0CB (W0) () A Circuit breaker No. of Stages Volts Input kw Input Btuh Input Blower Motor Full Load Amps Minimum Circuit Ampacity Maximum Overcurrent Protection Ckt Ckt Ckt Ckt Single Point Power Source Minimum Maximum Circuit Overcurrent Ampacity Protection 08.0 0,0.0 - - - - - - - - - - - - 0.,0.0 - - - - - - - - - - - - 0.7,0.0 - - - - - - - - - - - - 0.0,60.0 6 - - - 0 - - - - - - - - - 08.8,800.0 8 - - - 0 - - - - - - - - - 0.,00.0 9 - - - 0 - - - - - - - - - 0.6,700.0 0 - - - 0 - - - - - - - - - 0.0 7,00.0 - - - - - - - - - - - - 08.,00.0 - - - - - - - - - - - - 0.0 7,00.0 - - - - - - - - - - - - 0. 8,800.0 - - - - - - - - - - - - 0 6.0 0,00.0 6 - - - 0 - - - - - - - - - 08 6.0 0,00.0 - - - - - - - - - - - - 0 6.7,900.0 - - - - - - - - - - - - 0 7.,00.0 - - - - - - - - - - - - 0 8.0 7,00.0 7 - - - 0 - - - - - - - - - 08 6.8,00.0 6 - - - 0 - - - - - - - - - 0 7.6,800.0 8 - - - 0 - - - - - - - - - 0 8. 8,00.0 0 - - - 0 - - - - - - - - - 0 9.0 0,700.0 - - - 60 - - - - - - - - - 08 9.,000.0 8 0 6 70 0 0.,800.0 0 0 6 70 0. 9,00.0 6 0 68 70 0.,600.0 7 0 7 80 08. 8,00.0 8 0 7 80 0.6,000.0 9 8 0 0 77 80 0.8 7,000.0 0 0 0 0 80 80 0.0,00.0 60 8 90 08.0,00.0 6 0 0 0 9 00 0 6.8 7,00.0 8 0 60 0 0 0 8. 6,700.0 0 0 60 0 0 0 0.0 68,00.0 7 60 60 09 0 08 6.0 0,00.0 6 - - - 0 - - - - - - - - - 0 6.7,900.0 7 - - - 0 - - - - - - - - - 0 7.,00.0 8 - - - 0 - - - - - - - - - 0 8.0 7,00.0 8 - - - 0 - - - - - - - - - 08 7.,600.0 - - - - - - - - - - - - 0 8. 8,700.0 - - - - - - - - - - - - 0 9.,00.0 - - - - - - - - - - - - 0 0.0,00.0 - - - 0 - - - - - - - - - 08. 8,00.0 - - - - - - - - - - - - 0.6,000.0 6 - - - 0 - - - - - - - - - 0. 7,000.0 8 - - - 0 - - - - - - - - - 0.0,00.0 0 - - - 0 - - - - - - - - - 08.0,00.0 6 0 7 60 0 6.8 7,00.0 8 0 6 70 0 8. 6,700.0 9 0 6 70 0 0.0 68,00.0 0 0 6 70 NOTE - Circuit Minimum Circuit Ampacity includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 6. HACR type circuit breaker or fuse. CBXMV / Page 6

ELECTRIC HEAT DATA - CBXMV-08 AND CBXMV-060 Minimum Circuit Ampacity Model Number SINGLE PHASE kw ECB0- (W89) lbs. ECB0-CB (W90) kw lbs. 6 kw lbs. 8 kw lbs. 9 kw lbs.. kw 0 lbs. kw lbs. 0 kw 9 lbs. kw 9 lbs. A Circuit breaker ECB0- (W87) ECB0-CB (W90) A Circuit breaker ECB0-6 (W88) ECB0-6CB (W9) 0A Circuit breaker ECB0-8 (W89) ECB0-8CB (W9) 0A Circuit breaker ECB0-9CB (W9) 60A Circuit breaker ECB0-.CB (W9) () 0A and () A Circuit breaker ECB0-CB (W9) () A and () 60A Circuit breaker ECB0-0CB (W96) () 60A Circuit breaker ECB0-CB (W97) () 60A and () A Circuit breaker THREE PHASE 8 kw ECB0-8 (W98) lbs. Terminal block 0 kw 6 lbs. kw lbs. 0 kw 9 lbs. kw 9 lbs. ECB0-0 (W99) Terminal block ECB0-CB (W00) 0A Circuit breaker ECB0-0CB (W0) () A Circuit breaker ECB0-CB (W0) () 0A and () 0A Circuit breaker No. of Volts kw Stages Input Input Btuh Input Blower Motor Full Load Amps Maximum Overcurrent Protection Ckt Ckt Ckt Ckt Ckt Ckt Single Point Power Source Minimum Maximum Circuit Overcurrent Ampacity Protection 08.0 0,0 7. 7 - - - - - - 0 - - - - - - - - - - - - 0.,0 7. 8 - - - - - - 0 - - - - - - - - - - - - 0.7,0 7. 9 - - - - - - 0 - - - - - - - - - - - - 0.0,60 7. 0 - - - - - - 0 - - - - - - - - - - - - 08.8,800 7. - - - - - - - - - - - - - - - - - - 0.,00 7. - - - - - - - - - - - - - - - - - - 0.6,700 7. - - - - - - - - - - - - - - - - - - 0.0 7,00 7. - - - - - - 0 - - - - - - - - - - - - 08.,00 7. 6 - - - - - - 0 - - - - - - - - - - - - 0.0 7,00 7. 8 - - - - - - 0 - - - - - - - - - - - - 0. 8,800 7. 9 - - - - - - 0 - - - - - - - - - - - - 0 6.0 0,00 7. - - - - - - - - - - - - - - - - - - 08 6.0 0,00 7. - - - - - - 0 - - - - - - - - - - - - 0 6.7,900 7. 7 - - - - - - 0 - - - - - - - - - - - - 0 7.,00 7. 9 - - - - - - 0 - - - - - - - - - - - - 0 8.0 7,00 7. - - - - - - 60 - - - - - - - - - - - - 08 6.8,00 7. 0 - - - - - - 60 - - - - - - - - - - - - 0 7.6,800 7. - - - - - - 60 - - - - - - - - - - - - 0 8. 8,00 7. - - - - - - 60 - - - - - - - - - - - - 0 9.0 0,700 7. 6 - - - - - - 60 - - - - - - - - - - - - 08 9.,000 7. 8 8 - - - 0 0 - - - 66 70 0 0.,800 7. 9 0 - - - 0 0 - - - 69 70 0. 9,00 7. 0 - - - 0 - - - 7 80 0.,600 7. - - - - - - 7 80 08. 8,00 7. - - - - - - 77 80 0.6,000 7. 8 - - - 0 - - - 8 90 0. 7,000 7. 0 - - - 0 - - - 8 90 0.0,00 7. - - - 0 60 - - - 88 90 08.0,00 7. 0 0 - - - 0 0 - - - 00 00 0 6.8 7,00 7. - - - 60 60 - - - 0 0 8. 6,700 7. - - - 60 60 - - - 09 0 0.0 68,00 7. 6 7 - - - 60 60 - - - 08 8.8 6,00 7. 7 8 8 0 0 0 0.0 7,700 7. 9 0 0 0 0 0 9 0 0.0 78,00 7. 60 0 0.0 8,00 7. 60 0 08 6.0 0,00 7. 0 - - - - - - - - - - - - - - - - - - 0 6.7,900 7. - - - - - - - - - - - - - - - - - - 0 7.,00 7. - - - - - - - - - - - - - - - - - - 0 8.0 7,00 7. - - - - - - - - - - - - - - - - - - 08 7.,600 7. - - - - - - 0 - - - - - - - - - - - - 0 8. 8,700 7. 7 - - - - - - 0 - - - - - - - - - - - - 0 9.,00 7. 8 - - - - - - 0 - - - - - - - - - - - - 0 0.0,00 7. 9 - - - - - - 0 - - - - - - - - - - - - 08. 8,00 7. 8 - - - - - - 0 - - - - - - - - - - - - 0.6,000 7. - - - - - - 60 - - - - - - - - - - - - 0. 7,000 7. - - - - - - 60 - - - - - - - - - - - - 0.0,00 7. - - - - - - 60 - - - - - - - - - - - - 08.0,00 7. 6 - - - 0 0 - - - 6 70 0 6.8 7,00 7. 7 8 - - - 0 0 - - - 6 70 0 8. 6,700 7. 8 9 - - - 0 0 - - - 67 70 0 0.0 68,00 7. 9 0 - - - 0 - - - 70 70 08 8.8 6,00 7. - - - - - - 7 80 0.0 7,700 7. - - - - - - 78 80 0.0 78,00 7. 6 - - - 0 0 - - - 8 90 0.0 8,00 7. 7 8 - - - 0 0 - - - 8 90 NOTE - Circuit Minimum Circuit Ampacity includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 6. HACR type circuit breaker or fuse. CBXMV / Page 7

ELECTRIC HEAT DATA - CBXMV-068 No. of Volts kw Model Number Stages Input Input SINGLE PHASE kw ECB0- (W87) lbs. ECB0-CB (W90) 6 kw lbs. 8 kw lbs. 9 kw lbs.. kw 0 lbs. kw lbs. 0 kw 9 lbs. kw 9 lbs. A Circuit breaker ECB0-6 (W88) ECB0-6CB (W9) 0A Circuit breaker ECB0-8 (W89) ECB0-8CB (W9) 0A Circuit breaker ECB0-9CB (W9) 60A Circuit breaker ECB0-.CB (W9) () 0A and () A Circuit breaker ECB0-CB (W9) () A and () 60A Circuit breaker ECB0-0CB (W96) () 60A Circuit breaker ECB0-CB (W97) () 60A and () A Circuit breaker THREE PHASE 8 kw ECB0-8 (W98) lbs. Terminal block 0 kw 6 lbs. kw lbs. 0 kw 9 lbs. kw 9 lbs. ECB0-0 (W99) Terminal block ECB0-CB (W00) 0A Circuit breaker ECB0-0CB (W0) () A Circuit breaker ECB0-CB (W0) () 0A and () 0A Circuit breaker Btuh Input Blower Motor Full Load Amps Minimum Circuit Ampacity Maximum Overcurrent Protection Ckt Ckt Ckt Ckt Ckt Ckt Single Point Power Source Minimum Maximum Circuit Overcurrent Ampacity Protection 08.8,800 7. - - - - - - - - - - - - - - - - - - 0.,00 7. - - - - - - - - - - - - - - - - - - 0.6,700 7. - - - - - - - - - - - - - - - - - - 0.0 7,00 7. - - - - - - 0 - - - - - - - - - - - - 08.,00 7. 6 - - - - - - 0 - - - - - - - - - - - - 0.0 7,00 7. 8 - - - - - - 0 - - - - - - - - - - - - 0. 8,800 7. 9 - - - - - - 0 - - - - - - - - - - - - 0 6.0 0,00 7. - - - - - - - - - - - - - - - - - - 08 6.0 0,00 7. - - - - - - 0 - - - - - - - - - - - - 0 6.7,900 7. 7 - - - - - - 0 - - - - - - - - - - - - 0 7.,00 7. 9 - - - - - - 0 - - - - - - - - - - - - 0 8.0 7,00 7. - - - - - - 60 - - - - - - - - - - - - 08 6.8,00 7. 0 - - - - - - 60 - - - - - - - - - - - - 0 7.6,800 7. - - - - - - 60 - - - - - - - - - - - - 0 8. 8,00 7. - - - - - - 60 - - - - - - - - - - - - 0 9.0 0,700 7. 6 - - - - - - 60 - - - - - - - - - - - - 08 9.,000 7. 8 8 - - - 0 0 - - - 66 70 0 0.,800 7. 9 0 - - - 0 0 - - - 69 70 0. 9,00 7. 0 - - - 0 - - - 7 80 0.,600 7. - - - - - - 7 80 08. 8,00 7. - - - - - - 77 80 0.6,000 7. 8 - - - 0 - - - 8 90 0. 7,000 7. 0 - - - 0 - - - 8 90 0.0,00 7. - - - 0 60 - - - 88 90 08.0,00 7. 0 0 - - - 0 0 - - - 00 00 0 6.8 7,00 7. - - - 60 60 - - - 0 0 8. 6,700 7. - - - 60 60 - - - 09 0 0.0 68,00 7. 6 7 - - - 60 60 - - - 08 8.8 6,00 7. 7 8 8 0 0 0 0.0 7,700 7. 9 0 0 0 0 0 9 0 0.0 78,00 7. 60 0 0.0 8,00 7. 60 0 08 6.0 0,00 7. 0 - - - - - - - - - - - - - - - - - - 0 6.7,900 7. - - - - - - - - - - - - - - - - - - 0 7.,00 7. - - - - - - - - - - - - - - - - - - 0 8.0 7,00 7. - - - - - - - - - - - - - - - - - - 08 7.,600 7. - - - - - - 0 - - - - - - - - - - - - 0 8. 8,700 7. 7 - - - - - - 0 - - - - - - - - - - - - 0 9.,00 7. 8 - - - - - - 0 - - - - - - - - - - - - 0 0.0,00 7. 9 - - - - - - 0 - - - - - - - - - - - - 08. 8,00 7. 8 - - - - - - 0 - - - - - - - - - - - - 0.6,000 7. - - - - - - 60 - - - - - - - - - - - - 0. 7,000 7. - - - - - - 60 - - - - - - - - - - - - 0.0,00 7. - - - - - - 60 - - - - - - - - - - - - 08.0,00 7. 6 - - - 0 0 - - - 6 70 0 6.8 7,00 7. 7 8 - - - 0 0 - - - 6 70 0 8. 6,700 7. 8 9 - - - 0 0 - - - 67 70 0 0.0 68,00 7. 9 0 - - - 0 - - - 70 70 08 8.8 6,00 7. - - - - - - 7 80 0.0 7,700 7. - - - - - - 78 80 0.0 78,00 7. 6 - - - 0 0 - - - 8 90 0.0 8,00 7. 7 8 - - - 0 0 - - - 8 90 NOTE - Circuit Minimum Circuit Ampacity includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 6. HACR type circuit breaker or fuse. CBXMV / Page 8

DIMENSIONS - INCHES (MM) UPFLOW / (9) / (9) -/6 (8) D LINE VOLTAGE INLETS (Top and Left Side) TOP VIEW SUPPLY AIR OPENING / (9) LOW VOLTAGE INLETS (Top and Right Side) -/8 (9) SUCTION LINE () -/8 (7) LIQUID LINE -/ (70) DETAIL OF PIPING PLATE -/ () -/8 () -/ (89) CONDENSATE DRAINS () (Horizontal) CONDENSATE DRAINS () (Upflow and Downflow) B (6) C AIR FLOW G OPTIONAL ELECTRIC HEAT (Field Installed) BLOWER Note Units are shipped in one piece but may be disassembled into two separate sections for ease of installation. A PIPING PLATE H SUCTION LINE COIL LIQUID LINE Return Air F FRONT VIEW (6) (6) FILTER ACCESS FILTER () Return Air E SIDE VIEW (6) Model No. CBXMV-08 CBXMV-08/0 CBXMV-0/00 CXMV-06 CBXMV-068 CBXMV-060 inch mm inch mm inch mm inch mm inch mm A -/ 9 9-/ 9 8-/ 86 6 6 B 6-/ -/ 0 -/ 0 -/ 0 -/ 0 C 0-0- - 878-7/8 6 6-67 D -/ 7 9-/ 0 9-/ 0 9-/ 0 9-/ 0 E 9 8 9 8 8 6 F 8 0 08 0 08 0 08 0 08 G - 6-6 6-/ 60 7-7/8 708 -/8 8 H 0- - 6-6 0-778 - 89 CBXMV / Page 9

DIMENSIONS - INCHES (MM) DOWNFLOW DETAIL OF PIPING PLATE (6) E (6) F RETURN AIR OPENING (6) -/8 (9) SUCTION LINE () - (9) LIQUID LINE -/8 () CONDENSATE DRAINS () (Horizontal) CONDENSATE DRAINS () (Upflow and Downflow) () TOP VIEW () -/ () -/ (89) B FILTER ACCESS C FILTER H PIPING PLATE SUCTION LINE COIL LIQUID LINE AIR FLOW G A OPTIONAL ELECTRIC HEAT (Field Installed) LOW VOLTAGE (Right Side) LINE VOLTAGE (Left Side) BLOWER / (9) Supply Air D FRONT VIEW / (9) (6) Supply Air -/6 (8) SIDE VIEW (6) NOTE - Units are shipped in one piece but may be disassembled into two separate sections for ease of installation. Model No. CBXMV-08 CBXMV-08/0 CBXMV-0/00 CXMV-06 CBXMV-068 CBXMV-060 inch mm inch mm inch mm inch mm inch mm A -/ 9 9-/ 9 8-/ 86 6 6 B 6-/ -/ 0 -/ 0 -/ 0 -/ 0 C 0-0- - 878-7/8 6 6-67 D -/ 7 9-/ 0 9-/ 0 9-/ 0 9-/ 0 E 9 8 9 8 8 6 F 8 0 08 0 08 0 08 0 08 G - 6-6 6-/ 60 7-7/8 708 -/8 8 H 0- - 6-6 0-778 - 89 CBXMV / Page 0

DIMENSIONS - INCHES (MM) HORIZONTAL DETAIL OF PIPING PLATE RIGHT-HAND AIR DISCHARGE -/8 (7) () LIQUID LINE FILTER SUCTION LINE -/ (6) CONDENSATE DRAINS () (Upflow and Downflow) (6) -/ () -/ (8) -/8 (9) -/8 () CONDENSATE DRAINS () (Horizontal) LIQUID LINE COIL SUCTION LINE H TOP VIEW A BLOWER OPTIONAL ELECTRIC HEAT (Field Installed) G C Note Units are shipped in one piece but may be disassembled into two separate sections for ease of installation. (6) LINE VOLTAGE INLETS (Top and Right Side) -/6 (8) / (9) / (9) E (6) F RETURN AIR OPENING () PIPING PLATE AIR FLOW B SUPPLY AIR OPENING D (6) END VIEW FILTER ACCESS FRONT VIEW LOW VOLTAGE INLETS (Bottom and Right Side) END VIEW / (9) LEFT-HAND AIR DISCHARGE FILTER DETAIL OF PIPING PLATE C BLOWER COIL -/8 () Note Units are shipped in one piece but may be disassembled into two separate sections for ease of installation. OPTIONAL ELECTRIC HEAT (Field Installed) TOP VIEW SUCTION LINE LIQUID LINE -/8 (9) SUCTION LINE LIQUID LINE () -/8 (7) / (9) / (9) -/6 (8) LOW VOLTAGE INLETS (Top and Left Side) (6) G A H (6) / (9) D SUPPLY AIR OPENING END VIEW LINE VOLTAGE INLETS (Bottom and Left Side) B AIR FLOW FRONT VIEW -/ () PIPING PLATE -/ (6) FILTER ACCESS CONDENSATE DRAINS () (Horizontal) -/ (8) () E RETURN AIR OPENING F (6) END VIEW CBXMV-08 Model CBXMV-08/0 CBXMV-0/00 CXMV-06 CBXMV-068 CBXMV-060 No. inch mm inch mm inch mm inch mm inch mm A -/ 9 9-/ 9 8-/ 86 6 6 B 6-/ -/ 0 -/ 0 -/ 0 -/ 0 C 0-0- - 878-7/8 6 6-67 D -/ 7 9-/ 0 9-/ 0 9-/ 0 9-/ 0 E 9 8 9 8 8 6 F 8 0 08 0 08 0 08 0 08 G - 6-6 6-/ 60 7-7/8 708 -/8 8 H 0- - 6-6 0-778 - 89 (6) CBXMV / Page

DIMENSIONS - INCHES (MM) AIR FLOW PIPING PLATE AIR FLOW B B AIR FLOW PIPING PLATE A (6) RIGHT-HAND AIR FLOW B (6) (6) A LEFT-HAND AIR FLOW B AIR FLOW A Model No. A B in. mm in. mm CBXMV-08/0 -/ 9 6-/ PIPING PLATE A CBXMV-0/00 9-/ -/ 0 PIPING PLATE CBXMV-06 9 -/ 0 CBXMV-08 CBXMV-060 8-/ 86 -/ 0 CBXMV-068 6 6 -/ 0 AIR FLOW UPFLOW DOWNFLOW (6) SIDE RETURN UNIT STAND (Upflow Only) 6 (06) 6 () -08/0-6-/ -/() -0/00 (0) thru -060 - -/ (0) ADJUSTABLE 0 (08) to (6) ALL UNITS CBXMV / Page

DIMENSIONS - INCHES (MM) DOWNFLOW COMBUSTIBLE FLOORING BASE Catalog No. - J7 - () AIR HANDLER - () -/8 (89) SUPPLY AIR OPENING (8) -/ (9) - () TOP VIEW A -/8 (6) (6) -/ () Opening DOWNFLOW COMBUSTIBLE FLOORING BASE SIDE VIEW (76) Catalog No. K - () - () 0 (08) TOP VIEW -/8 (89) / (9) Break off extended width at pre-perforated line to fit specific air handler application. NOTE - Width of base includes an additional in. ( mm) for air handler positioning adjustment. - () SUPPLY AIR OPENING (6) -/ () Opening SIDE VIEW (76) BA BC CD E D No modification required. Model CBXMV-08 CBXMV-08/0 CBXMV-0/00 CBXMV-06 No. CBXMV-060 CBXMV-068 in. mm in. mm in. mm in. mm in. mm A -/8 6 - - - - - - - - - - - - - - - - - - - - - - - - B - - - - - - - 7 - - - - - - - - - - - - - - - - - - C - - - - - - - - - - - - - 6 - - - - - - - - - - - - D - - - - - - - - - - - - - - - - - - 6-676 - - - - - - E - - - - - - - - - - - - - - - - - - - - - - - - 8-77 CBXMV / Page

REVISIONS Sections Blower Data Description of Change Revised Continuous Fan Only Speed minimum cfm. Visit us at www.lennox.com For the latest technical information, www.lennoxdavenet.com Contact us at -800--LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 0 Lennox Industries, Inc.