ES860 OPTICAL TURNSTILE INSTALLATION AND OPERATION MANUAL PRESENT CARD

Similar documents
Bi-Directional Barrier Arm Turnstile

4040 FM 535 F :

OPTICAL TURNSTILE SYSTEM

SU2000-SM. model OPTICAL TURNSTILES DESCRIPTIVE SPECIFICATIONS TYPICAL INSTALLATION SITES COMMON APPLICATIONS ALVARADOMFG.COM

OPTICAL TURNSTILE SYSTEMS

ES880 GLASS BARRIER OPTICAL TURNSTILE INSTALLATION AND OPERATION

The following modes can be set when the units are installed, and/or can be changed later through use of a push button on the desktop controller:

Custom options such as housing finishes and design, lid have their presence felt. A combination of sleek, sophisticated

OptiStile 220. Swinging Barrier Arm Optical Turnstile

ARCHITECTURAL SPECIFICATIONS

Tailgate > Entry Sentry > ES5200

OptiStile 400. Non-Barrier Optical Turnstile

17.25 (438 mm) 37.5 (953 mm) 3.5 (89 mm) 3.0 (76 mm) 28 (711 mm) or 36 (915 mm)

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

SpeedStile FP. Full-Panel Speed Gate with Sliding Glass Barrier

SU5000. Optical Turnstiles. alvaradomfg.com

D A R A - 4. Data Aire Relay Auto-Changeover

Addendum for STI-6406 with Dual Access Control

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

ITEM # SAIL STREAM CEILING FAN MODEL #40048

MANUAL RESET ALARM RELEASE

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM

ERD97P21-U Receiver. Installation/ Operation Manual C939M-D (7/00)

The feedhorn heaters consist of heater wire attached to a strap and covered with heatshrink. They are attached to a rib on the feedhorn.

FLCH4R Garage and Utility Electric Heater

Computer Room Guard Model VM Manual and Installation Instructions

Exit Stopper. STI-6400 Series

TECHNICAL INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM

! WARNING. Before using product, read and understand instructions.

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

INFORMATION ONLY READ AND SAVE THESE INSTRUCTIONS SAFETY FIRST

Instruction Manual. Dogeroo, Super Dogeroo, and Mini Dogeroo

ETSA380MF SHOWN WARNING. shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Pump-Up Controller MODEL 4062

Exit Stopper. STI-6400 Series

TOUCHDOWN 48 CEILING FAN

Glendale 52 in Ceiling Fan Owner's Manual. Glendale Ventilador de Techo de 1.32 m Manual del Propietario

HI Industrial Utility Heater HI Soleus Air International

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Lifetime Limited Warranty

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

Installation Instructions

Pump-Down Controller MODEL 4052

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

ITEM # BUILDER S SERIES CEILING FAN MODEL #41391

MODEL RWM RADIATION WASTE MONITOR LUDLUM MODEL RWM RADIATION WASTE MONITOR INSTALLATION MANUAL

232xt Wiring Diagrams and Specifications SPECIFICATIONS: REV 1.01

ATS Annunciator - MODBUS

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Installation Instructions

Model: EF34. Owner's Guide & Installation Manual

Engineering Specifications

ITEM # , CARATUK RIVER CEILING FAN MODEL #40046, 40303

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

380 SERIES REMOTE SIREN ETSA380R

Ceiling PIR HS presence detector. Product Guide. Overview. Features

WATLOW ELECTRIC MFG CO. FIREBAR Screw Plug Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)

Combustible Gas Sample-Draw Detector Operator s Manual

INSTALLATION INSTRUCTIONS. WOOD BLINDS 1-3/8, 2 and 2-3/8 SLAT SIZES. COMPOSITE FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES

FIRERAY 5000 range USER GUIDE

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

Carbon Dioxide Sample-Draw Detector Operator s Manual

INSTALLATION INSTRUCTIONS

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

MANUAL RESET ALARM RELEASE

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

ITEM # SAIL STREAM CEILING FAN MODEL #41695

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

STRONG International FP-350 Operation and Installation Manual

ST. KITTS CEILING FAN

MODEL B2 INSTALLATION MANUAL

Heat Exchanger Block Replacement Instructions

Bedford Face Installation

"Pegaso" wireless alarm system

SUTTON 52 CEILING FAN

INSTALLATION, OPERATION AND MAINTENANCE

Static Pressure Control

ITEM # , , PAWTUCKET CEILING FAN MODEL #40958, 40959, 40047

Thermostats. Digital Programmable. GEAppliances.com

ELECTRIC FLAT PANEL FIREPLACE HEATER

PLL Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

Intelligent Swing Gate Turnstile Operating Manual CPW-322CS

52 CEILING FAN. Owner s Manual Models #50336, 50337

! WARNING. Before using product, read and understand instructions.

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

RR-PM1200 OPERATING AND PROGRAMMING GUIDE

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

Camarillo 52 Ceiling Fan

Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual

Torrena 42 Ceiling Fan

Vari-Cyclone Ceiling Fans

Transcription:

ES860 OPTICAL TURNSTILE INSTALLATION AND OPERATION MANUAL

To accommodate unique architectural arrangements of these bollards, their design and construction will allow their being installed in an arc shape, while maintaining full functionality of a DSI Optical Turnstile system. Site Preparation - Layout the arc and determine spacing and placement location for each bollard. Conduit should be routed to correspond with the hole in center of each bollard s base plate. Installation - Become familiar with the Components, their location, Wiring requirements, Alignment requirements, and Assembly/Disassembly steps before beginning the Installation process. Then: Disassemble the Bollard for installation Mount and orient the Base Plate / Internal Assembly Perform Wiring, Alignment and Initial Testing of unit Reassemble the bollard. Perform Final Test Configuration - Determine mode of operation. Free Exit, or Card In/Card Out. Configure for Free Exit if applicable. Considerations - In planning the final assembly, allow for alignment of sensors through Plexiglas panes in stainless steel exterior, avoiding interruption of light path by stainless steel pane dividers. Slots in mounting base plate allow for rotational adjustment of bollard. Cable path (conduit) between adjacent bollards is required for Exit Light Array cable. DESIGNED SECURITY INC 800 272 3555 Fax 512 321 9181 2 02 Hawthorne St., Bastrop, Texas 78602

Using the Suction Cup (included); Remove the Light Array Plexiglas cover by pulling it up and away from the top of the bollard. It is secured with magnetic tape and should require little force to remove. Using the same technique, remove the Light Array assembly. It is retained using double-sided tape. BOLLARD DISASSEMBLY / ASSEMBLY Disconnect the wiring from the Light Array. Note there are two cables attached with RJ-style connectors. One cable comes from the electronics below, the other is a longer cable which connects to the adjacent bollard s electronics which controls the Light Array s Exit functions. (End Bollards will only have one cable, Entry or Exit only) Place the Light Array in a safe place. Looking through the hole in the top of the bollard, you may now see the bolt which attaches the top to the internal structure. Remove this bolt. The top may now be lifted off the top of the bollard assembly. Note the alignment pin and corresponding notch for reference when re-assembling the unit. The top may have a tight fit, pull it straight up from underneath by reaching through the hole. Place the top in a safe place. The round external shell may now be removed. It is HEAVY, at least two persons should be used to lift it straight up in order to safely remove it and avoid damage to either the internal structure or the exterior shell. During assembly, note that the alignment pin should be oriented in such a way that, when facing from the Reflector/Electronics side of the bollard structure, the pin is centered on the left end of the top panel. 800 272 3555 Fax 512 321 9181 DESIGNED SECURITY INC 02 Hawthorne St., Bastrop, Texas 78602 3

Component Locations - The following photos will be used to define various points of reference which will be used throughout this document. The photos will also show detail regarding how to disassemble and reassemble each bollard. This photo shows the Internal parts of the bollard as seen from the Reflector/Electronics side. The Base Plate has a hole in the center for conduit access and Mounting Slots for securing and orienting the bollard in relationship to the adjacent bollards. The Reflectors are on a plate that may be adjusted to align with the Infrared Beams coming from the Sensors on the opposite bollard. (See Adjustment Photo for more Detail) The Electronics/MPU section is where all Input/Output terminations are made for Control signals, Alarm sensing and the Light Array operation. REFLECTOR SIDE The Sensor Side photo of the Internal structure shows the Sensors which generate and detect the IR Signals. These signals are monitored to provide access control. Their optical alignment may be adjusted by gently bending the Sensor mounting bracket and by loosening the screws for making minor vertical adjustments. (See Adjustment Photo for more Detail) SENSOR SIDE DESIGNED SECURITY INC 800 272 3555 Fax 512 321 9181 4 02 Hawthorne St., Bastrop, Texas 78602

MOUNTING Verify that the bollards are mounted in correct orientation. When viewed from the Entry/Un-secure side, the rightmost Bollard will be the first "smart" Bollard (unit with electronics). The left-most bollard will have reflectors only. ENTRANCE SIDE SECURED AREA Take time to thoroughly understand all aspects of configuration and operation prior to physical mounting. LOCATION OF ALIGNMENT PIN ON TOP INSIDE OF CYLINDER Recommended mounting anchors are 1/2 diameter bolts. Run wires from Access Control System to the Electronics package via 3.5 x3.5 square hole in base plate. RADIANS FROM ARC FOR ALIGNMENT REFFERENCE CENTER OF ARC WIRING Refer to the drawing "Wiring Diagram" for Input, Output and Light array connection details. Connect N/O dry contact from Exit Valid Card" output of the access system to TB2-10 & 12 (Valid 1). Set hold time on this contact, for valid card input, to less than 0.5 second, or as near as possible. Connect N/O dry contact from Entry Valid Card" output of the access system to TB2-11 & 12 (Valid 2). Set hold time on this contact, for valid card input, to less than 0.5 second, or as near as possible. Connect N/O dry contact from "Invalid card" output of the access system to TB2-7 & 9 (Invalid). Set the hold time on this Input for Invalid, to less than 0.5 second, or as near as possible. This input is optional. Connect N/O lane Bypass from remote monitoring equipment to TB2-7 & 8 (Bypass) for bypassing the lane, or to reset the MPU. Connect N/O Alarm output from MPU, on TB2-5 & 6 to remote monitoring equipment detecting an alarm condition. Connect 12 VAC 6 amp power supply to TB2-13 &. Wire gauge should be AWG for a wire run of 50 feet or less and 12 AWG for 50-100 feet. Greater distances may require calculating the appropriate wire gauge necessary. FREE EXIT MODE ENABLE Enable Free Exit Mode by shorting the Sensor 4 and Common terminals found at TB1-11 & 12. 800 272 3555 Fax 512 321 9181 DESIGNED SECURITY INC 02 Hawthorne St., Bastrop, Texas 78602 5

INFRARED SENSOR BEAMS The Infrared beams from the sensors pass through IR-Passing Plexiglas and will not pass through ordinary glass. If the IR Plexiglas becomes damaged or needs replacement, please contact DSI for additional information or replacement parts. SENSOR/REFLECTOR ALIGNMENT Once the bollards are in place and the wiring is complete, the system may be powered up and checked for proper alignment of the IR optical sensors. IR optical sensor alignment may be verified by observing the bi-color LED on the end of each sensor. Red LED off and Green on indicates the sensor is aligned with a reflector and a Lock state is present. The plate which the Reflectors are attached to may be adjusted to align the reflectors with the opposite bollard s Sensor light path. The Sensors may only need adjustment by rotation of the Bollard on it s base plate mounts to face the Reflector. If necessary, the sensor alignment may be fine-tuned by adjusting the bracket the Sensor is mounted on. Observe the sensor LED for Lock indication (Red LED off and Green on). Reflector Adjustment TIP: During alignment, cover adjacent sensors and reflectors in order to prevent alignment with the wrong reflector. For precision alignment use a card with a penny-sized hole to cover the center of the reflector being used. This will focus the beam to a tighter tolerance before a Green LED is lit. Once the IR sensors are aligned, and connections to the access control system verified, the passageway should operate normally, allowing passage on a valid input for that direction, as well as sounding an alarm for an invalid passage, and provide remote control of the lane if the optional inputs are connected to remote switches. ADJUSTMENTS Adjustment P.1 (Alarm Reset) sets the delay on the Alarm Auto Reset (adjustable 1-20 seconds). This is the time the unit will remain in Alarm mode after a violation. Adjustment P.2 (Valid Access Delay) sets the time allowed for a valid card user to walk through the passageway before the system resets for the next user (adjustable 1-20 seconds). If a user does not walk through after being validated, this delay is how long the lane will wait before resetting for the next user. DESIGNED SECURITY INC 800 272 3555 Fax 512 321 9181 6 02 Hawthorne St., Bastrop, Texas 78602

COMPONENTS LIGHT ARRAYS The Light Arrays provide visual cues to the user. The appropriate Light Array will be found on the User s right, regardless of direction of travel. All Exit-side Graphics are referenced as 1 (i.e.: Valid 1, Horizontal 1) on the MPU connections. All Exit side hardware (Light Array, Reader) are found on the right-hand side, when entering the lane from the EXIT or Secure side. This places these pieces of hardware in the bollard across the lane from the MPU/ Electronics Package for any given lane. The Long cable is used to connect this Light Array to the adjacent Bollard s MPU for that lane. All Entry-side Graphics are referenced as 2 (i.e.: Valid 2, Horizontal 2) All Entry side hardware (Light Array, Reader) are also found on the right-hand side, when entering the lane from the ENTRY or Un- Secure side. These pieces of hardware are mounted in the same bollard the MPU/Electronics Package is mounted in. The Short cable is used to connect this Light Array to the MPU in the same Bollard. The Horizontal Array has three modes; Present Card (Card Arrow is lit); Alarm or In Use (Bar is flashing or lit); and Proceed (Arrows) End bollards will consist of a Smart unit at one end (with MPU), and a Reflector only unit at the other end. The Smart end bollard will have only 1 light array connection via a 3 cable from Horiz 2 on the MPU in the same bollard. This array will be oriented towards the Entry, or un-secure, side. The Reflector only bollard at the other end of the installation will also only have 1 light array connection via a 15 cable to the Horiz 1 on the adjacent bollard s MPU controlling that lane. This Array will be oriented towards Exit side. All Center bollards have dual arrays (Entry and Exit) and connect with both a 3 local (Entry-Horiz 2) and 15 adjacent (Exit-Horiz 1) cable. 800 272 3555 Fax 512 321 9181 DESIGNED SECURITY INC 02 Hawthorne St., Bastrop, Texas 78602 7

OPERATION / USER INSTRUCTIONS Approaching the lane from the Entry (un-secure) side: Watch light array for prompt to. Scan Entry card, then wait for a beep and look for before proceeding. Move through the lane at a normal stride, keeping loose items in front of, or beside your body. Not swinging. If there is an alarm, wait for security personnel to respond. Approaching the lane from the Exit (secure) side: If Free Exit mode is enabled, the Light Array will display Green Arrows indicating that the user should proceed. If Card Out mode is enabled, the Light Array will prompt the user to Present Card. Scan Card, then wait for a beep and look for Green Arrows before proceeding. Move through the lane at a normal stride, keeping loose items in front of, or beside your body. Not swinging. If there is an alarm, wait for security personnel to respond. Alarm Conditions may be caused by: A user passing through the lane without validation. A user tailgating a valid user. A valid user swinging a briefcase, umbrella, coattail, etc. may appear to be a tailgater. A User entering the lane in one direction when validation has been given to a User coming from the opposite direction. An Alarm Output on TB2 5 & 6 An Invalid Input on TB2 9 & Common Alarm Conditions may be cancelled by: Auto reset timeout. (P1 adjustable 1-20 seconds) Bypass Input DESIGNED SECURITY INC 800 272 3555 Fax 512 321 9181 8 02 Hawthorne St., Bastrop, Texas 78602

SPECIFICATIONS Technical Data: (electrical) Inputs: Outputs: Power: 12VAC @ 4 Amp/Walkway Access Control: N/O Dry Contact from access control system for valid card (Entry & Exit) N/O Dry Contact from access control system for invalid card Shunt: N/O Dry Contact to Override lane operation Free Exit Mode Enable: Free Exit Mode may be enabled by placing a jumper across TB-1 Pins 11&12 Valid Access Delay: P1 adjusts 1-20 Seconds Alarm Auto Reset Delay: P2 adjust 1-20 Seconds N/O Alarm Contact N/O Invalid Card Contact - 500mA @ 30 VDC - 500mA @ 30 VDC Technical Data (mechanical): Size: Ht: 38 Dia: 13.5 Mounting: 3.5 x3.5 Conduit access; 3 ea. 1/2 mounting bolts. Finish: Top surface - DuPont Corian Pedestal - Stainless Steel WARRANTY The DSI Optical Turnstile Product you have purchased is warranted to be free of defects in material and workmanship when properly installed, used and maintained according to instructions. DSI will, for a period of three (3) years from date of purchase, repair or replace any part which, upon our examination, proves to be defective under normal use. DSI/DETEX SHALL NOT BE LIABLE FOR ANY DIRECT, INCIDENTAL OR CONSEQUENTIAL LOSS OR DAMAGE ARISING OUT OF THE FAILURE OF THIS DEVICE. 800 272 3555 Fax 512 321 9181 DESIGNED SECURITY INC 02 Hawthorne St., Bastrop, Texas 78602 9

DSI Power Wire-Run Gauge Calculator If used to calculate a: Use this form to determine the wire gauge of the power trunk for equipment. DAISY CHAIN application - one where all equipment is attached to the same trunk, you will need to calculate the total load and the total distance in wire run to the last load on the chain. HOME RUN application - where each piece of equipment is on a separate trunk returning to the central power supply, you use this form to determine the gauge for each run. 1. Specify total Current load of all devices sharing this trunk, in Amps. 2. Specify Distance of actual Wire Run (in feet) from power supply to most remote load. 3. Multiply figures from line 1 and line 2 4. Match final number to Table below to determine Wire Gauge needed to provide adequate Voltage. TABLE up to 45 22AWG 45 to 90 18AWG 90 to 170 16AWG 170 to 275 AWG 275 to 415 12AWG 415 to 680 10AWG If your result is greater than 680, make individual supply runs to each device, or sub-sets of devices, which are within the above parameters. EXAMPLE: 3 devices @.250,.500,.125 amps - total amps of.875 Distance of 150 ft. 150 times.875 = 131.25 131.25 falls into the category of 16 AWG wire. DESIGNED SECURITY INC 800 272 3555 Fax 512 321 9181 10 02 Hawthorne St., Bastrop, Texas 78602

TS - 1 TS - 1 TS - 1 ACCESS CONTROL 800 272 3555 Fax 512 321 9181 DESIGNED SECURITY INC 02 Hawthorne St., Bastrop, Texas 78602 11 SECURED / EXIT READER SIDE PEDESTAL #2 PEDESTAL #3 PEDESTAL #4 LANE #3 R S S R LANE #2 PEDESTAL #1 RETRO-REFLECTOR R 12 POWER VAC 4 SUPPLY AMPS 12VDC 4 AMPS PER PER LANE LANE (WALKWAY) LANE #1 S R S SENSOR POWER SUPPLY UNSECURED / ENTRANCE READER SIDE CABLING AND LAYOUT DIAGRAM REQ'D. PATH FOR CABLE BETWEEN BOLLARDS (CABLE SUPPLIED BY DSI) TYPICAL ILLUSTRATION FOR IN / OUT 3 LANE SYSTEM

4 7 9 10 11 1 5 6 7 SEE NEXT PAGE FOR LEGEND 2 3 4 8 9 10 1 5 6 11 11 11 12 13 13 13 15 16 17 18 1 2 3 19 19 5 6 8 12 19 20 21 21 21 22 EXPLODED DIAGRAM DESIGNED SECURITY INC 800 272 3555 Fax 512 321 9181 12 02 Hawthorne St., Bastrop, Texas 78602

LEGEND FOR EXPLODED DIAGRAM ITEM 1 2 3 4 5 6 7 8 9 10 11 12 13 PARTS LIST DESCRIPTION HGA SCREENED PLEXI-ES860 3" MAGNETIC TAPE STRIP HGA SUB ASSEMBLY 1 2" DOUBLE SIDE TAPE STRIP 1/4" x 4" CARRIAGE BOLT.307" ID x.749" OD FLAT AL WASHER 15' HGA CABLE 3' HGA CABLE ES860 TOP ES860 TOP MTG BRACKET 1 #8 x 1" WOOD SCREW ES860 ENCLOSURE ES860 PLEXI RETAINER 1 6-32 LOCK NUT ITEM 15 16 17 18 19 20 21 22 23 24 25 26 27 28 PARTS LIST DESCRIPTION TOP MTG BRACKET 2 #10 x 1/2" SOCKET HEAD CENTER SUB ASSMB, SENSOR CENTER SUB ASSMB, REFLECTOR ES860 PLEXI RETAINER 2 ES860 LANE LABEL #10 x 1/2" FH PHILLIPS ES860 BASE ES860 TOP PLEXI RING ES860 BOTTOM PLEXI RING SUCTION CUP READER DECAL 12 VAC 6 AMP TRANSFOMER PRODUCT INSTRUCTIONS TOP VIEW 800 272 3555 Fax 512 321 9181 DESIGNED SECURITY INC 02 Hawthorne St., Bastrop, Texas 78602 13

JUMPER TO ENABLE FREE EXIT MODE DESIGNED SECURITY INC. 1-800-272-3555 WIRING DIAGRAM DESIGNED SECURITY INC 800 272 3555 Fax 512 321 9181 02 Hawthorne St., Bastrop, Texas 78602

NOTES: 800 272 3555 Fax 512 321 9181 DESIGNED SECURITY INC 02 Hawthorne St., Bastrop, Texas 78602 15