Development of a meter-scale U-shaped Oscillating Heat Pipe for GAPS

Similar documents
VISUAL STUDY ON TWO-PHASE FLOW IN A HORIZONTAL CLOSED-LOOP OSCILLATING HEAT PIPE , Thailand , Thailand

EXPLORING POSSIBILITIES WITH THE DEVELOPMENT OF THE LOOP HEAT PIPE TECHNOLOGY. Roger R. Riehl

Effect of Inclination Angle on Performance Limit of a Closed-End Oscillating Heat Pipe

Experimental Analysis on Effect of Design Parameters on the Performance of Single Loop Pulsating Heat Pipe

Internal flow Patterns of the Horizontal Heat Mode Closed-Loop Oscillating Heat Pipe with Check Valves (HHMCLOHP/CV)

Effect of Parameters on Internal Flow Patterns of a Top Heat Mode Closed-loop Oscillating Heat Pipe with Check Valves (THMCLOHP/CV)

MINIATURE HEAT TRANSPORT SYSTEMS WITH LOOP HEAT PIPES

Experimental Study And CFD Based Simulation of Closed Loop Pulsating Heat Pipe Using of Refrigerants (R-134a)

0Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe

Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions

Thermal performances of a meter-scale cryogenic pulsating heat pipe.

Measurement of internal pressure and thermal performance in a closed-loop oscillating heat-pipe with check valves (CLOHP/CV)

TWO-PHASE MICRO-CHANNEL HEAT SINK FOR SPACE CRAFT THERMAL CONTROL

American International Journal of Research in Science, Technology, Engineering & Mathematics

Thermal Performance of a Loop Thermosyphon

EVALUATING LOOP HEAT PIPE PERFORMANCE IMPROVEMENT USING CIRCUMFERENTIAL GROOVES. Nadjara dos Santos, Roger R. Riehl

Operating Characteristics of Multiple Evaporators and Multiple Condensers Loop Heat Pipe with Polytetrafluoroethylene Wicks

Heat Transfer in Evacuated Tubular Solar Collectors

Integration of a Pulsating Heat Pipe in a Flat Plate Heat Sink

Experimental Investigation on the Effection of Flow Regulator in a Multiple Evaporators/Condensers Loop Heat Pipe with Plastic Porous Structure

Experimental Study on Waste Heat Recovery from the Pyrolysis Stack using Heat Pipe

Experimental study of hybrid loop heat pipe using pump assistance for high heat flux system

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Experimental Investigation of Closed Loop Oscillating Heat Pipe as the Condenser for Vapor Compression Refrigeration

Sodium Heat Pipes for Spacecraft Fission Power Generation

The Variable Effective Surface Radiator

Development of the Micro Capillary Pumped Loop for Electronic Cooling

Closed Loop Pulsating Heat Pipe with a Hydrocarbon as Working Fluid: A Review

Niti KAMMUANG-LUE *, Phrut SAKULCHANGSATJATAI, and Pradit TERDTOON

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

Compression of Fins pipe and simple Heat pipe Using CFD

High Temperature Water-Titanium Heat Pipes for Spacecraft Fission Power

COOLING SYSTEM FOR HERMETIC COMPRESSOR BASED ON THE LOOP THERMOSYPHON

Heat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a

Operation of a Two-Phase Reverse Loop Thermosyphon

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

PERFORMANCE EVALUATION OF THE MINIATRIZED CATALYTIC COMBUSTION TYPE HYDROGEN SENSOR

High Temperature Water Heat Pipes for Kilopower System

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Smoldering Propagation Characteristics of Flexible Polyurethane Foam under Different Air Flow Rates

A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

International Engineering Research Journal Experimental Investigation of Effect of length on Performance of Axially Grooved Heat Pipe.

Variable Thermal Conductance Link for Lunar Landers and Rovers

Keywords: slope stability, numerical analysis, rainfall, infiltration. Yu. Ando 1, Kentaro. Suda 2, Shinji. Konishi 3 and Hirokazu.

International Engineering Research Journal

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Impact of TXV and Compressor in the Stability of a High-End Computer Refrigeration System

Keywords: ECM, suction tool, auxiliary electrode, current density, machining characteristics

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Diode Heat Pipes for Long-Lived Venus Landers

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION

Temperature Oscillation of mlhp with Flat Evaporator

Performance Study of Solar Heat Pipe with Different Working Fluids and Fill Ratios

Full and Partial Load Performances of RAC and CAC Heat Pump using R-32

MINIMISING THE RISK OF WATER HAMMER AND OTHER PROBLEMS AT THE BEGINNING OF STAGNATION OF SOLAR THERMAL PLANTS- A THEORETICAL APPROACH

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Evaluation of Liquid Water Content in Thermal Efficient Heating Mechanism Using Water Vapor for Industrial Furnace

Experimentation of Heat Pipe Used In Nano-Fluids

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

Benefits and Drawbacks of Using Two-Phase Cooling Technologies in Military platforms

EFFECT OF WATER RADIATOR ON AIR HEATING SOLAR COLLECTOR EFFICIENCY

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

EXPERIMENTAL STUDY ON THE LOOP HEAT PIPE OPERATING UNDER HORIZONTAL ORIENTATION

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

LAMINATION AND CHARACTERIZATION OF A POLYETHYLENETEREPHTHALATE FLEXIBLE MICRO HEAT PIPE

MICRO HEAT PIPE SYSTEM FOR SPACE AVIONICS

Transmissivity of a Nonwoven Polypropylene Geotextile Under Suction

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Variable far infrared radiation (VFIR) technique for cubic carrot drying

Performance Study of Triple Concentric Pipe Heat Exchanger

Characterization of a Heat Sink with Embedded Heat Pipe with Variable Heat Dissipating Source Placement for Power Electronics Applications

Performance Analysis of Heat Pipe using Different Screen Mesh Sizes Manikandan.K * 1, Senthilkumar.R 2,

Feasibility Study of Use of Elevators in Fire Evacuation in a High-rise Building

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

Passive cooling of telecommunication outdoor cabinets for mobile base station

Performance Analysis of a Thin Tube Water Heater for Egerton University Using Comsol

Optimization of Various Thermal Management Techniques for High Thermal Loads

Properties of a two stage adiabatic demagnetization refrigerator

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

PERFORMANCE OF WATER FILLED THERMOSYPHONS BETWEEN OC

FABRICATING A HEAT PIPE STRUCTURE WITHIN A RADIATING PLATE FOR ELECTRONICS FAN-LESS COOLING

Experimental Investigation of Two Phase Closed Thermosyphon Using Propylene Glycol As A Working Fluid

Basic CFD model of heat pipe

Performance of Water-in-Glass Evacuated Tube Solar Water Heaters

To investigate the surface properties for increasing efficiency of solar water heater

Design of Miniature Loop Heat Pipe

APPLICATION OF MINI HEAT PIPES FOR THERMAL MANAGEMENT OF OPTO-ELECTRONIC INSTRUMENTS

Welcome to the World of Aavid Heat Pipes

HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS?

COOLING OF DESKTOP COMPUTER USING HEAT PIPES

Review on Closed Loop Oscillating Heat Pipe

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

Transcription:

42nd International Conference on Environmental Systems - 19 July 12, San Diego, California AIAA 12-3499 Development of a meter-scale U-shaped Oscillating Heat Pipe for GAPS Shun Okazaki 1, Hideyuki Fuke 2, Hiroyuki Ogawa 5 Japan Aerospace Exploration Agency (JAXA), Kanagawa 2-521, Japan and Downloaded by Japan Aerospace Exploration Agency (ISAS/JAXA) on January 2, 13 http://arc.aiaa.org DOI: 1.14/6.12-3499 h p H p C g Takuma Okubo 3, Yoshiro Miyazaki 4 Fukui University of Technology, Fukui 91-855, Japan Thermal performance of a 6m-long Oscillating Heat pipe (OHP) for balloon-borne General Anti-Particle Spectrometer (GAPS) experiment has been investigated. The developed OHP is a closed loop type and U-shaped due to the mission detector requirements. R41A is selected as the working fluid for the use at low temperature. We achieved a thermal conductance of 18.7 W/K for W heat input with 16 turns at + deg-c. We also found for the first time that this large-scale OHP can be operated at low temperatures when the cooling section is cooled from + deg-c to -6 deg-c. In addition to the well-known advantages of OHP that it can be simply fabricated and has low sensitivity to the orientation, it is found that the OHP has an adjustability and flexibility to 3-dimensional alignment and wide temperature range. Nomenclature = pressure head = vapor pressure of the heating section = vapor pressure of the cooling section = density of the working fluid = gravitational acceleration I. Introduction HE thermal performance of a meter-scale Oscillating Heat Pipe (OHP) for General Anti-Particle Spectrometer T(GAPS) has been investigated. GAPS is a balloon-borne project, which aims to contribute to solve the dark matter mystery through highly sensitive cosmic-ray observation[1]. Due to the balloon flight environment different from spacecraft, the GAPS thermal control system has to work in gravity. The biggest challenge of the GAPS thermal control system is to cool the core detectors. The feature of the heat source is large amount of heat and low heat flux. The detectors are spread over a wide area of 2m x 2m x 2m and their total heat dissipation is about 8 W. The detector must be cooled down to lower than - deg-c. Therefore, the working fluid must be suitable for the low temperature. The heat must be transported to the radiator attached to the payload sidewall which is 2 m apart from the detectors on average. The heat transfer route is required to be U-shaped; the two vertical sides of U-shape correspond to the heat input section and the radiator section, and the horizontal side corresponds to the adiabatic section. In our present design of GAPS heat transfer device using OHP, the number of OHP turn is about 1 in total. Since the radiator is expected to be cooled down to around -5 deg-c, a heat transport capability per turn larger than 1 Engineer, Institute of Space and Astronautical Science, 3-1-1 Yoshinodai. 2 Assistant Professor, Institute of Space and Astronautical Science, 3-1-1 Yoshinodai. 3 Graduate Student, Department of Electrical, Electronic and Computer Engineering. 4 Professor, Department of Electrical, Electronic and Computer Engineering. 5 Associate Professor, Institute of Space and Astronautical Science, 3-1-1 Yoshinodai, AIAA Member. 1 Copyright 12 by the, Inc. All rights reserved.

8 W and a temperature difference between the heating section and the cooling section less than 1 deg-c are required. Since the OHP has been researched mainly to understand its physical phenomena, most of the OHPs studied in the past were desktop-scaled less than 1 m with a flat shape and were operated at room temperature. For the basic study, we developed a scaled U-shaped OHP with a turn length of 1 m, and we could confirm that the OHP has a capability to satisfy the GAPS thermal requirements such as the U-shaped 3-dimensional routing and the cold temperature operation [2]. Based on this basic study, we have developed an OHP with an actual size of 6 m turn length. This paper reports the experimental results of the 6m-long U-shaped OHP. Downloaded by Japan Aerospace Exploration Agency (ISAS/JAXA) on January 2, 13 http://arc.aiaa.org DOI: 1.14/6.12-3499 II. Oscillating Heat Pipe (OHP) An oscillating heat pipe (OHP) consists of a meandering capillary tube that does not need an internal wick. The capillary tube goes back and forth several times between a heating section and a cooling section. The OHP operation relies on the oscillation and/or circulation of vapor plugs and liquid slugs in the capillary tube. Vapor bubbles are generated and grow in the heating section, and then collapse in the cooling section. The generation and the collapse of vapor bubbles pump the liquid slugs, which cause the pressure and temperature fluctuations. The feature of the OHP is simple fabrication, lower sensitivity to orientation than conventional heat pipes, capability of large amount of heat transfer, and adjustability to the low heat flux[3]. The OHP can enhance its potential by utilizing it as the temperature controllable OHP with liquid reservoir[4]. The temperature of the heating section may be controlled by the temperature of the liquid reservoir. It is also expected that the reservoir is useful to keep the amount of effective working fluid by compensating for the leak. We consider that OHP is a suitable thermal control device for GAPS. As previously described, we have investigated the thermal performance of a U-shaped OHP with 1m turn length. We succeeded in operating the 1m U-shaped OHP in low temperature by using R41A as the working fluid. III. Experimental Set-up Figure 1 illustrates the set up of the tested OHP and the locations of the thermocouples. The test specimen consists of an OHP and a liquid reservoir. The reservoir connection point, the working fluid, the tube diameter, and locations of check valves are determined to be same as the 1m-length U-shaped OHP described in the previous sections. The reservoir is connected to the OHP adiabatic section close to the heating section. The OHP is a closed loop type and U-shaped. The lengths of the heating, cooling, and adiabatic sections are 2m each. R41A is used as the working fluid. The inner and outer diameters of copper capillary tubes are 1. and 1.6 mm, respectively. The number of tubes turn between the heating section and cooling section is scaled down to sixteen. Sixteen check valves are installed in the adiabatic section to force the working fluid flow in one direction. The capillary tubes at the heating and adiabatic sections are insulated by a Styrofoam cover. At the cooling section, the tubes where the working fluid rises are insulated and the tubes where the working fluid falls are not insulated. The vapor from the heating section should push the working fluid at the cooling section. Therefore, we considered that the working fluid which flows against gravity should be vapor because the density of the vapor is lower than the liquid. Thirteen heater sheets are attached to the heating section to simulate the heat source distribution of the GAPS detectors. The liquid reservoir is a stainless steel tank with a volume capacity of ml. A Kapton heater is attached to the reservoir for the temperature control. A feedback controller is used to control the heat input to the reservoir heater. The temperatures measured by thermocouples are monitored every second. All tests were conducted in a temperature controllable room at atmospheric pressure. 2

mm mm Heating section TC 2 TC5 TC 1 Heater line (13 layers) TC6 TC 3 Downloaded by Japan Aerospace Exploration Agency (ISAS/JAXA) on January 2, 13 http://arc.aiaa.org DOI: 1.14/6.12-3499 Cooling section TC7 TC4 Reservoir Fig. 1 Schematic illustration of the experimental OHP with thermocouples. IV. Experimental Result A. Performance at room temperature The liquid reservoir temperature was controlled to be 1 deg-c higher than the temperature at the bottom of cooling section. The power consumption of the reservoir for the temperature control was less than 1 W. Figure 2 shows the temperature profile at the start-up with a heat input of 5 W. The cooling section temperature was kept to be deg-c. After a steep increase of the vapor line temperature, the heating section temperature shows a start-up of oscillation. However, it was observed that the OHP operated only intermittently with the 5 W heat load. Figure 3 shows the temperature profile when the heat input to the heating section was once set to 1 W for the start-up, then increased to W in 5 W increments, and again decreased to 1 W in decrements of 5 W. It was observed that the steep increase of the heating section temperature is followed by a sharp descent to around deg- C, and then the OHP operates stably. It is considered that the pressure of the vapor pushes up the liquid in the cooling section against the gravity, and thus the working fluid starts oscillation and circulation. When the heat input is increased to W, the temperature of the top of heating section raises. This might indicate that a local dry-out occurs in the capillary tube around the top of the heating section. This local dried-out area seems to expand to the middle of the heating section when the heat input is increased to W. From these results, we could confirm for the first time that the 6m-length U-shaped OHP can be operated in room temperature. The OHP shows a good repeatability with no temperature hysteresis in the heat input range of 1 W, which corresponds to 6 1 W per 1 turns. TC8 3

Temperature[deg-C] Heat input[w] Temperature[deg-C] Heat input[w] 45 1 4 TC 1 (H_Middle) TC 4 (Adiabatic) TC 2 (H_Top) 1 8 TC 8 (Reservoir) 6 Downloaded by Japan Aerospace Exploration Agency (ISAS/JAXA) on January 2, 13 http://arc.aiaa.org DOI: 1.14/6.12-3499 TC 3 (H_Bottom) 4 Heat input TC 5 (C_Top) TC 6 (C_Middle) TC 7 (C_Bottom) 1 4 Time[sec] Fig.2 Temperature profile at the start up with 5 W heat input. 55 TC 2 (H_Top) 5 TC 1 (H_Middle) 45 TC 3 (H_Bottom) 4 Heat input TC 8 (Reservoir) TC 4 (Adiabatic) 1 5 TC 5 (C_Top) TC 6 (C_Middle) TC 7 (C_Bottom) 5 1 Time[sec] Fig.3 Temperature profile when the heat input is varied between 1 and W in steps. B. Performance at low temperatures down to -6 deg-c Figure 4 shows a result of the temperature profiles when the cooling section temperature was decreased from + deg-c to -6 deg-c at a constant heat input of W. It can be said that the OHP operates and shows a good thermal conductance above - deg-c. However, the thermal conductance of the OHP decreased down to 1 W/K with decreasing the cooling section temperature. This result indicates that the performance of the OHP is not good enough at low temperatures under the present configuration conditions. 4

Temperature[deg-C] Conductance[W/K] 4 1-1 Downloaded by Japan Aerospace Exploration Agency (ISAS/JAXA) on January 2, 13 http://arc.aiaa.org DOI: 1.14/6.12-3499 - Heating section Ave. -5 Cooling section Ave. T Reservoir Conductance -7 1 5 7 Time[min] Fig.4 Variations of temperatures and heat conductance when the cooling section is cooled from deg-c to -6 deg-c. C. Performance of cold start-up at each temperatures We have carried out the cold start-up test of the OHP at various temperatures. A heat load of 1 W was applied at first, and then was increased to W followed by W. At anytime, the liquid reservoir temperature was controlled 1 deg-c higher than the cooling section temperature. The amount of the heat leak from heating section to the surroundings was measured by a blank test without working fluid. Figure 5 shows the conductance of OHP with cooling section temperatures at each temperature. The thermal conductance of the OHP with a liquid reservoir is expected to show an increase with the increasing heat input to keep the heating section temperature constant as is shown by 1 W and W data.[4] However, at all temperatures, the thermal conductance did not increase when the heat input was increased from W to W. It is supposed that the operating mode changes between W and W, since the temperature profile suggests a local dry-out around the top and middle of the heating section. At -4, -5 and -6 deg-c, the thermal conductance was only 4 W/K, which is almost same as the conductance of blank test. This result shows that the OHP did not work as a heat transfer device. When the heat input was increased to W, the OHP started up at -4 and -5 deg-c. The thermal conductance of the OHP increases with increasing the cooling section temperature at every heat input. The OHP starts up at +, and - deg-c with 1 W heat load. Since the vapor pressure is low at low temperature, it is considered that the vapor generated in the heating section cannot push the liquid up into the cooling section. The pressure head generated between the heating section and the cooling section can be expressed by where,, and g are the pressure, the density of the working fluid, and the constant of gravitation, respectively. The suffixes H and C indicate the heating section and the cooling section. The OHP is expected to start oscillation when the heating section is heated up to around the reservoir temperature, which is controlled to be 1 deg-c higher than the cooling section temperature. To realize the start-up of the OHP operation, the vapor of the heating section should sweep the liquid into the cooling section through the adiabatic section. Since the height of the U-shaped OHP is 2 m, the pressure head should be higher than 2 m. Figure 6 shows the pressure head calculated from the previous equation assuming that the temperature difference is 1 deg-c and the working fluid is R41A. The saturated vapor pressure and the density of R41A are taken from Ref. [5]. According to this calculation, even at the low temperatures around -6 deg-c, the pump head is higher than 2 m. Therefore we had expected that the OHP can operate at low temperatures. However, in practice, the OHP didn t start up at all at -4 deg-c and didn t start up efficiently at - 1 5 5

Pressure head [m] Conductance [W/K] deg-c with W heat input. It is considered that some additional factor (such as the friction loss of tube flow and check valve) has to be taken into account to judge the capability of OHP start-up. Downloaded by Japan Aerospace Exploration Agency (ISAS/JAXA) on January 2, 13 http://arc.aiaa.org DOI: 1.14/6.12-3499 4 1 5-6 deg-c -5 deg-c -4 deg-c - deg-c deg-c deg-c Blank TEST 5 1 Heat input [W] Fig.5 Thermal conductance after start-up at various temperatures and with various heat inputs. 4 38 36 34 32 28 26 24 22 18 16 14 12 1 8 6 4 2-6 -5-4 - - -1 1 Environment temperature[deg-c] Fig.6 Calculated pressure head of R41A assuming a 1 deg-c temperature difference between the heating and cooling sections. 6

Downloaded by Japan Aerospace Exploration Agency (ISAS/JAXA) on January 2, 13 http://arc.aiaa.org DOI: 1.14/6.12-3499 V. Conclusion Thermal performance of the 6m-length U-shaped Oscillating Heat Pipe developed for General Anti-Particle Spectrometer has been investigated. We found for the first time that this large-scale OHP operates at deg-c with a sufficient heat conductance that satisfies the design conditions required by the GAPS mission instruments. The test results can be summarized as follows; 1) The OHP starts up at deg-c. The thermal conductance of 18.7 W/K for W heat input meets the GAPS design requirement. 2) The OHP can operate in low temperatures down to -6 deg-c, when the cooling section is cooled from deg-c with a constant heat input of W. The performance of the OHP becomes worse when the cooling section temperature is below around - deg-c. 3) The thermal conductance of the OHP decrease with the low cooling section temperature. Although the developed OHP has achieved the mission requirements partly for now, we still consider that the OHP is a useful thermal control device for practical use and has a potential to fully meet the GAPS requirements. Through further studies, we are going to make improvements such as optimizing of the tube diameter and seeking for more suitable working fluid material. Once this large-scale OHP is realized, OHP is expected to be utilized for many applications. References 1 Hailey, C.J., Aramaki, T., Boggs, S.E., v.doetinchem, P., Fuke, H., Gahbauer, F., Koglin, J.E., Madden, N., Mognet, S.A.I., Ong, R., Yoshida, T., Zhang, T., Zweerink, J.A., Antideuteron based dark matter search with GAPS: Current progress and future prospects Advances in Space Research (to be published). 2 Deveropment of the Cooling System for GAPS detectors Okazaki, S., Fuke, H., Miyazaki, Y., Okubo, T., Ogawa, H., Development of the Cooling System for GAPS detectors Space Science Symposium, P4-438, Jan. 12.(in Japanese) 3 Akachi, H., Polasek, H., Strulc, P., Pulsating Heat Pipes, Proceedings of the 5 th International Heat pipe Symposium, Melbourne, Australia, Royal Melbourne Inst. of Technology, Melbourne, Austria, 1996, pp. 8-217. 4 Iwata, I., Ogawa, H,. Miyazaki, Y., Temperature Controllable Oscillating Heat Pipe, Journal of Thermophysics and Heat Transfer, Vol. 22, No. 3, 11, pp. 386-392. 5 Nagashima, A. (eds), Thermophysical Properties Handbook, Japan Society of Thermophysical Properties Series, Yokendo, Tokyo Japan, 8, pp. 448-446. 7