ICS Integrated Cryocooling System

Similar documents
ICS Integrated Cryocooling System

ICS Integrated Cryocooling System

MÖBIUS Recycler Condensing Liquid Nitrogen HPGe Detector Cooling System

MÖBIUS Recycler. Condensing Liquid Nitrogen HPGe Detector Cooling System

ORTEC DSPEC LF. High-Performance Digital Signal Processor for Gamma Spectroscopy. ... in a compact package at an economical price.

ORTEC ICS-P4 TM. Integrated Cryocooling System for ORTEC PopTop TM Capsules. User Manual

DSP EC Pro. Advanced, Digital Gamma-Ray Spectrometer for HPGe Detector Systems

Performance of a New Type of Electrical Cooler for HPGe Detector Systems

X-Cooler III Mechanical Cooler for HPGe Detectors

North American Technical Services

ORTEC. Detective-Remote. Multiple Instrument Remote Monitoring and Control Software. The right software, the right solution, the right answer!

XPIN -XT X-ray Detector Operation Manual

dewar or an electrically powered cooler. The sensitive detector surfaces are thus protected from moisture and condensable contaminants.

Liquid Helium Level Instruments

Unattended Radiation Sensor Systems for Remote Terrestrial Applications and Nuclear Nonproliferation

Remote Helium Cooling Loops for Laboratory Applications

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

NEW COOLING OPTION FOR DETECTORS

V * V V V V V-25L-230* V * V *

INNOVATIVE WATER VAPOR CRYOPUMP TECHNOLOGIES PRODUCT CATALOG

Variable Temperature Microprobe Systems

High performance dry leak detectors ASM 182 TD+ ASM 192 T2D+ HELIUM LEAK DETECTORS 297 > 308

Portable Instruments For First Response & In-Situ Analysis of Radiation

Highlights of Germanium Detector technology

PHOENIX L300i New Standards in Helium Leak Testing The next Generation

Variable Temperature Options for Optical Experiments

junctioncrew.com FR28 INNOVATIVE PERFORMANCE MADE SIMPLE SUREFIRE SUREFIRE BLOCK HEATER THE INDUSTRY S STRONGEST WARRANTY HOSE HEATER

10 K Airborne Cryocooler and

LUDLUM MODEL ALPHA, BETA, GAMMA HAND DETECTOR. June 2016 Serial Number and Succeeding Serial Numbers

Gas condensing boiler (wall mounted) TopGas

Lead-Lined Cabinetry. 7 Vreeland Road, Florham Park, NJ or

AM-806. Waste/Door Radiation Monitor OPERATIONS MANUAL

Victoreen & 660-8

Continuous and Point Level Measurement. Radiometric Sensors for Liquid and Solid Level Measurement

275HVD NON-CONTACT, HIGH VOLTAGE DETECTOR DETECTOR DE ALTA TENSIÓN SIN CONTACTO

GAMMA RAY DETECTION PROBE MODEL SO16

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

SCFM REFRIGERATED COMPRESSED AIR DRYERS. CRN Series

XRD XRD-1500 High-Temperature Oven. Innovation in Material Science...

Setting the Benchmark

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

MULTI-POINT DENSITY ARRAY FIXED-POINT INTERFACE PROFILING MEASUREMENT

Hotplates, Magnetic Stirrers and Stirring Hotplates

The Art and Science of Being Cool

5900 SERIES Low Energy Power Operator

Rotary Screw Vacuum Systems

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

TIMS TIMS. Thermal Ionisation Mass Spectrometry.

Thermal Shock Chamber TSE 11

HPIC Meeting - Austin

86 C freezers. New Benchmark. New Brunswick sets the standard for extraordinary freezer quality, support, and energy savings

5900 Series X-in Low Energy Power Operator

CHECKFIRE 210 Detection and Actuation System

Spiralair SPR 2-30 TECHNOLOGY YOU CAN TRUST

Lochinvar Leadership. Innovative High-Efficiency Water Heating Products

OTF5000 Cryostat. At the cutting edge of sectioning technology

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Controls Surface mounted pushbuttons Suitable for gloved use. Buttons Side - On/Off Front Menu Scroll Pin Hole Setup access

Techne Dri-Block range. Premium products at affordable prices. Adjustable safety cut-out. 230V and 115V variants. New 5-digit LED display

MODEL 951 RADIATION DETECTOR

ELD500 PRECISION LEAK DETECTOR

AcoustiFlo Fans: Retrofit Solutions and Beyond

GP SERIES Packaged Chillers

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

Distributed by ECO LIGHT PRODUCT OVERVIEW. Hazardous Area Luminaires

PORTABLE or FIXED PERSONNEL & VEHICLE MONITOR

Victoreen Primalert 35 Area Radiation Monitor

Air-cooled Screw Chillers Model RTAF G Process

E-16 Main Engine Remote Control System

BUDERUS. Quality. Versatility. Efficiency. Superior Design. Comfortable. Efficient. Intelligent Heating. Conventional Gas Boilers

AIR or STACK MONITOR NOBLE GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE. Optional Alpha, Tritium, Carbon-14

MOBILE CALL GSM Alarm System User s Manual

Technical Manual Ionisation Chamber MUSIC80

NON-CYCLING REFRIGERATED AIR DRYERS. RNC Series

LUDLUM MODEL and PANCAKE CLUSTER DETECTORS. June 2016

The Majorana Demonstrator Update and Detector Technologies

Rotary Screw Compressors SK Series

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

Modules and Accessories. Table of Contents. Theta Optical Tensiometer. I - Mandatory modules 2. II - Accessories 4

Oil-Free Compressors. Oil-Free Compressors. Quincy QOF Series Oil-Free Air Compressors QOF 2-30 HP

Can one cool the MICE magnets and the Hydrogen Absorbers with Small Coolers? Michael A Green Oxford University Physics Oxford OX1 3RH, UK

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

Rotary screw Air compressors. Fixed Speed 5 15HP

MetRad1 Handheld Metal/Gamma Detection Unit. Operation Manual. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since 1963 BNC

Rotary Screw Compressors SM Series

Temptek Auxiliary Equipment

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Flexibility right from the start. PAVIRO Public Address and Voice Evacuation System with Professional Sound Quality. boschsecurity.

Technologies, Solutions, and Applications. Radiation-based Level

800 MHz US 2 NMR system

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

Rotary Screw Compressors. SK Series With the world-renowned SIGMA PROFILE Flow rate 0.53 to 2.70 m³/min, Pressure 5.5 to 15 bar

When reliability is vital. Alemite Carbon Shield TM Systems deliver

Users Manual. LAURUS Systems, Inc. - Ph: Fax:

LUDLUM MODEL AND LUDLUM MODEL ALPHA, BETA, & GAMMA DETECTORS

Model ID-441-C InGaAs Near Infrared Detector with Preamplifier and Thermoelectric Cooler Operating Instructions

Transcription:

ICS Integrated Cryocooling System ORTEC s most advanced Integrated Cryocooling System offers premium detector resolution and LN 2 -free operation, for excellence in performance, safety, reliability and value.

ICS The newest integrated electro-mechanical cooling system for HPGe radiation detectors from ORTEC exploits the latest generation in cryogenic technology to provide LN 2 free operation with no loss of detector performance. Incorporating a unique hardened cryostat, ICS delivers enhanced benefits for users desiring state-of-the-art electro-mechanical cooling solutions. ICS is a highly reliable, maintenance free, electro-mechanically cooled cryostat delivering superior performance for HPGe radiation detectors. Using a Sunpower 1 industry proven Stirling cooler, ICS is more efficient and reliable than pulse tube designs. Increased efficiency means improved cooling with proportionally less heat generation and lower power consumption. With a cooler Mean-Time- To-Failure (MTTF) of over 200,000 hours, ICS operational reliability is unmatched. ICS incorporates AVC (Active Vibration Cancellation) technology, and is designed to virtually eliminate vibrational and audible noise levels. This provides resolution performance comparable to LN 2 cooled systems in all operational orientations, and making it the choice for customers seeking premium resolution and versatility in a vast array of HPGe applications. ICS is designed with a vacuum hardened cryostat This feature eliminates the need to fully thermal cycle the detector in the event of a partial warm-up, a common deficiency in other types of electro-mechanical or LN 2 cryostats. Additionally, ICS does not require the use of gas filters or lines used in older generation Joule-Thomson or Klemenko cycle coolers eliminating their associated maintenance issues. As a result, ICS delivers significant improvements in operational up time and maintenance free ease-of-use. Simplicity in Concept and Simplicity in Use ICS delivers superior performance in a compact footprint that reduces weight and eliminates the need for an external control box present in other, more cumbersome electro-mechanical cooling systems. ICS supports high resolution spectrometry with LN 2 free operation for legacy system upgrades as well as new HPGe radiation detector systems. 1 Sunpower is a part of AMETEK Advanced Measurement Technology (AMT), a division of AMETEK s Electronic Instruments Group (EIG). 2

Benefit Performance Resolution Versatility Environmental Friendly Safety Reliability Cost Effective Low Cost of Ownership Availability Compatibility Feature Supports all ORTEC GEM detectors. Consult the factory for compatibility with GMX and Profile detectors. LN 2 free operation with LN 2 equivalent resolution AVC TM technology Vibration dampeners Multi-orientation operation Wide operating temperature range ( 10 C to 40 C) Quiet, less than 60 db (A) at 1 meter below 30 C ambient LN 2 free operation High Voltage Shutdown Full 2-year warranty on the cryocooler Long service life, MTTF > 200,000 hours cooler LN 2 free operation Low power consumption (Sunpower cooler) Long service life, MTTF > 200,000 hours cooler No maintenance (no gas lines or filters) Vacuum hardened cryostat (no molecular sieve, no need for thermal cycling) Small footprint and light weight (integrated controller, no external box) Select the cooling rod length at the time of the order. Lengths are available from 2 12 inches (51 305 mm) in.5 inch increments. Spectroscopic Performance When purchasing a new ORTEC detector with an ICS, resolution performance is based on the specifications in the detector configuration guide for your selected detector type. ICS cool down time depends on the detector size and starting temperature. For example, typical cool down time for a 60% relative efficiency coaxial detector from room temperature is approximately six hours. Return to the factory is required when upgrading an existing LN 2 or electro-mechanical system, ORTEC or other, to an ICS. Performance of an upgraded detector is warranted to be within 10% of the combined resolution and efficiency of the HPGe detector at the time of the upgrade determined at the factory before reconfiguration. An example of combined relative efficiency and resolution is a 5% increase in resolution and a 5% decrease in relative efficiency, or a 10% increase in resolution and 0% decrease in relative efficiency. 3

Typical Applications Commercial, Government and Environmental Labs The ICS is a superb choice due to no compromise of resolution performance and low audible noise. There is no requirement for refilling the LN 2 on a regular basis, providing increased cost savings, detector availability, and minimizing work hazard. Nuclear Power and Industrial Plants The ICS provides an advantage in deployments where power failures are frequent. The hardened cryostat increases detector availability by eliminating the need for thermal cycling and reduces equipment down time. With no need for regular maintenance and LN 2 filling, personnel spend less time in radiation hot zones. The compact size of the ICS allows easy installation into new or existing counting setups. Research Facilities/Universities Similar to Lab applications, the ICS is an excellent choice due to no compromise of resolution performance and low audible noise. No need for LN 2 gives the ICS a low cost of ownership. Waste Management Hardened cryostat specification makes the ICS an excellent choice for applications requiring maximum up time. Health Physics Low heat generation, low audible noise and no compromise on resolution performance give the ICS an edge for HPGe systems in the field of health physics, whether as an upgrade or as a new HPGe system. Field Remediation, Mobile or Remote Monitoring The ICS is an unmatched solution in these applications due to a combination of unique features: the hardened cryostat which eliminates the need to fully thermal cycle the detector in the event of a partial warm-up, low power consumption and the use of a universal power supply. Key Attribute Commercial, Government and Environmental Labs Nuclear Power and Industrial Plants Major Market Benefits Research Facilities/ Universities Waste Management Health Physics Field Remediation, Mobile or Remote Monitoring LN 2 Free P P P P P P High Resolution P P P Quiet Operation P P P Compact Size P P P P Hardened Cryostat P P P Low Power Consumption P P Wide Operating Temperature P P P All Attitude Operation P P P P 4

Specifications HPGe Compatibility Resolution Cooler All-Attitude Operation Hardened Cryostat Molecular Sieve Compatible Endcap Windows Weight Environmental Typical Power Consumption Electrical Supply Status Display Connectors Remote Preamp PopTop Compatible Low-Background Option Audible Noise Auxiliary Cooling Backup Battery Cooler Life Warranty Maintenance Stand Compatibility All ORTEC GEM detectors. Consult factory for compatibility with GMX, Profile or other manufacturer s detectors. New ORTEC detectors: Warranted equivalent to LN 2 with cooler running at room temperature (see detector configuration guide for specifications). AMETEK Sunpower with AVC (active vibration cancelation) technology. Yes Yes No Aluminum, Carbon Fiber, Beryllium. 40 lbs (18 kg) excluding the detector. Temperature range: 10 C to 40 C. Humidity: non-condensing. 70 W typical, 130 W maximum. 100 240 V AC (50/60 Hz) auto ranging. 4 LED lights indicate status: power ON/OFF, COLD, cooler On/OFF, preamp count rate. 4 each BNC (energy out, energy or timing out, HV Shutdown, test). 1 each SHV cable (high voltage in). 1 each 9 pin (preamp power). Note: 1) additional BNC is added for TRP preamp (-PL) option. 2) HV Shutdown out is converted to Temperature Readout in the SMART option. Yes No Yes Less than 60 db (A) at 1 meter fully operational, below 30 C ambient. Internal fan (vented). No built-in battery. ICS is compatible with commercial batteries and universal power supplies (UPS). ORTEC offers an optional UPS. >200,000 hours. 2 years on cryocooler, internal controller and active noise cancelation. 1 year on detector and preamplifier. Easily removable, washable inlet air filter. No other maintenance is required. Stand not included. Optional stand (ICS-STAND) is available. 5

Dimensions Dimensions listed in mm (inches) are for reference only and subject to change. If dimensional constraints are critical, contact the factory. Endcap Model (dia. mm) -70-76 -83-95 -108 % Efficiencies available in this endcap size Dim. Unit Tol. A BB CC LL mm (in) mm (in) mm (in) mm (in) 0.3 (0.01) 0.3 (0.01) 5 (0.2) 3 (0.1) 0 35 25 45 25 65 60 110 120 150 70 (2.75) 85 (3.4) 145 (5.7) 76 (3.0) 92 (3.6) 158 (6.2) 83 (3.25) 98 (3.9) 158 (6.2) 95 (3.75) 111 (4.4) 158 (6.2) 108 (4.25) 124 (4.9) 183 (7.2) Choose from 51, 64, 76, 89, 102, 114, 127, 140, 152, 165, 178, 191, 203, 216, 229, 241, 254, 267, 279, 292, or 305 NOTE: [102 mm (4 in.) is typical length] 6

Accessories The ICS-STAND is intended for single user installation of the ICS. It incorporates a multi-positional height selector to set overall operating height, and uses a pneumatic arm to raise and lower the ICS. This variable height selection accommodates most commercial shield tables. Rollers on the stand provide easy positioning of the ICS underneath the shields. Note, the ICS-STAND is for vertical orientation only. Caution: Since the ICS must be installed into a shield from below, the user must ensure the shield opening is greater than the detector seal-clamp diameter. (Dimension BB.)

Ordering Information See the GEM detector configuration guide. Consult the factory for ordering GMX and PROFILE detectors. ORTEC www.ortec-online.com Tel. (865) 482-4411 Fax (865) 483-0396 ortec.info@ametek.com 801 South Illinois Ave., Oak Ridge, TN 37830 U.S.A. For International Office Locations, Visit Our Website Specifications subject to change 091014