HAVE A SAMPLING AND ANALYSIS PLAN (SAP)

Similar documents
R I T Title: Manual Processing Bench #2 Semiconductor & Microsystems Fabrication Laboratory Revision: C Rev Date: 08/05/2008

General Acids/Bases Bench Right and Left SOP

Operation of heat exchangers

Fleck 5600 Carbon Filter Installation & Start Up Guide

Laboratory Glassware Cleaning and Storage

Scale Stopper Plus Installation & Start-Up Guide

R I T Title: RCA Bench #2

EQUIPMENT CLEANING Indira Pindi Watershed Monitoring September 20, 2017

CWS Plus Sediment Filter Installation & Start Up Guide

Watch Water USA Green Chemical Technology

Well Disinfection. Safety Concerns. Electrical. Chemical

Up-Flow Carbon Installation & Start-Up Guide

5000 Series Bottled Water System by.

AC40 & AC40BAutomatic Water Softener Operation and Recharging

The Cameron Clean Room

Water Distillation System Instruction Manual Nutriteam TC-501

Certified according to ISO 9001:2008 and ISO 14001:2004

The Heidelberg Integrated 14 CO 2 Sampler Institute of Environmental Physics, ICOS CRL

Sinks A clog, low water pressure a nonfunctioning sink can practically shut

Installation, Operation and Maintenance Manual

What If No Water? Children, nursing mothers, and sick people may need more water.

phd Countertop UltraWater Owner s Manual Delicious Great Tasting Antioxidant Alkaline Energized

Entertainment Faucet with Remote Valve

Lead in Priority Area Sampling Report Naval Air Station Patuxent River

Is my water safe to drink? How do I determine the quality of my water? Common Questions about Discolored Water: Cloudy or milky water

Laboratory SAFETY RULES

SELF-CONTAINED FLAKER

LAB SAFETY FOR CUSTODIANS

EDISON DUAL HANDLE VESSEL SINK FAUCET

Safety Lab Goggles are required! Apron is optional!

NBSeries Installation Operation & Maintenance

Iron Air Charge MangOx 2510 SXT Installation & Start Up Guide

Installation, Operation and Maintenance Manual

DUKE UNIVERSITY CONSTRUCTION STANDARDS

Chanson Water USA, INC. Installation Guide for SCF-3000/SCF-6000

475 PRO SERIES Reverse Osmosis System Installation & Operation Manual

Wet Bench Standard Operating Procedures

Series # 17 3-Hole Widespread Faucet with Push Drain

Science Department Safety Training Notes

CAOL VESSEL SINK FAUCET INSTALLATION

Instructions for Use A-dec Self-Contained Water System

Owners Manual for the Rainmaster Water Recycling System

Installation, Operation and Maintenance Manual

Hoshizaki America, Inc.

7500-S Sediment Backwash Filter Guide

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

Before using your machine, you must familiarize yourself with all of its components.

AUBEREE CENTERSET FAUCET INSTALLATION

Owners Guide ScaleSolver Residential System

What Is Retrofit? Most retrofit devices will reduce your water and sewer bill enough to pay for themselves within six months.

Clean Water Made Easy

Target Monobloc Kitchen Mixer Chrome

Installation & Operation Instructions

Useful Equations and Conversions

INSTALLATION INSTRUCTIONS. Uptown Contempo Widespread Faucets Part # s: 8880-****, 8881-****

A few simple steps to ensure perfect water, every time.

Owners Manual For The Rainmaster Water Recycling System

C. EWFs shall deliver the quality and quantity of water that is satisfactory for emergency washing purposes.

STUDENT SAFETY RULES

WATER SAVING TIPS SAMPLE. for Your Home

Water Quality in Hydronic Systems April 16, 2015 with Guest Speaker Jim Poehling, P.E., LEED AP Q&A Documentation

1. Conduct yourself in a responsible manner at all times in the laboratory.

ispring Whole House Water Filter Systems USER S MANUAL

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

MENZA CENTERSET FAUCET INSTALLATION

Safety procedures: Wear your PPE. Gloves and goggles when filling the chemical bottle, using the machine, and cleaning the machine.

Green & Clean Program Hair Salon Application

APEX Water Filters MODEL RO 5. Treat your body to pure goodness with Apex filtered water INSTRUCTION MANUAL. pure water in every drop

1. Conduct yourself in a responsible manner at all times in the laboratory.

Clean Water Made Easy

The plating industry

INSTALLATION & SERVICE MANUAL

Water Softener & Single Tank Triple Treat System Installation Overview. Using 1850 Metered Valves

Washroom care programs

CAUTION: EYE IRRITANT. Economy Size 32 FL OZ NET 1 QT (32 FL OZ) 946 ml KEEP OUT OF REACH OF CHILDREN SEE BACK PANEL FOR PRECAUTIONARY STATEMENTS

AGITATOR V DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

Fresh Water Availability

Karbon Kitchen Sink Tap

AQUA ONE. Reverse Osmosis System Model ARO5000. Installation and Service Guide PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

Clean Water Made Easy

Chemistry Materials Separation Processes

How to Use Water Safely in Acute Health Care Sites During a Boil Water Advisory

AQUAVOLTA MOSES 7. Alkaline Water Ionizer SM-V112TL USER MANUAL. presents. Use acidic water that is:

Hoshizaki America, Inc.

Southwest Florida Water Management District. Fix It for Less

7800 Neutralizer Installation & Start-Up Guide

AC39 Manual Water Softener Operation and Recharging

Read Only Document Not For Distribution

Sink faucet Kohler 2007 X 5:

SELF-CONTAINED CRESCENT CUBER

PrimePour TM Operation Manual

Clean Water Made Easy. Fleck 7000 Tannin Filter Installation & Startup Guide. Questions?

Standard Operating Manual. Ultra Fab Wet Station F Non-standard Processing Station

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

AUC Cell Washer. User Manual

Operation and Maintenance Manual Sondex All-Welded Heat Exchangers (SAW)

APP Environmental Services P/L.

Descaler & Prevention

CHAMPION PUMP OWNER S MANUAL

MICRO CLEANER. OPERATOR MANUAL Advance MODEL /10 Rev E Document Number

Transcription:

THE HOW TO OF SAMPLING, TRANSPORTING, AND DELIVERY HAVE A SAMPLING AND ANALYSIS PLAN (SAP) INCLUDE SAMPLING LOCATIONS NUMBERS AND TYPES OF SAMPLES TO BE COLLECTED QUALITY CONTROL REQUIREMENTS OF THE PROJECT 1

THINGS TO CONSIDER WHEN CHOOSING TIME AND SAMPLING SITES CONSIDER THE WEATHER- AVOID COLLECTING SAMPLES WHEN IT IS RAINING OR SNOWING CONSIDER THE LOCATION- AVOID FAUCETS THAT ARE EXCESSIVELY DIRTY, IN NEED OF REPAIR OR CLOSE TO THE GROUND. SAMPLE FROM A COLD WATER FAUCET THAT IS HIGH ENOUGH TO PUT A BOTTLE UNDERNEATH WITHOUT TOUCHING THE FAUCET FREE FROM SCREENS, AERATION DEVICES, HOSES, PURIFICATION DEVICES OR SWIVELS THE GOAL IS TO AVOID CONTAMINATING THE SAMPLE BEFORE SAMPLING CONTACT YOUR CONFIRM DATE OF SAMPLING CONFIRM ANALYSIS REQUIRED PICK UP REQUIRED BOTTLES PICK UP REQUIRED PRESERVATIVES PICK UP CHAIN OF CUSTODY (COC) 2

GETTING READY TO SAMPLE OPEN THE FAUCET AND FLUSH FOR A FEW MINUTES WHILE FLUSHING GET BOTTLES READY LABEL TAKE THE CL2 AND PH RECORD ON COC PUT ON GLOVES AND SAFETY GLASSES REDUCE FLOW TO A STEADY STREAM WITHOUT SPLASHING GENERAL SAMPLING FILL SAMPLE BOTTLES MAKING SURE NOT TO TOUCH THE FAUCET. COLLECT ENOUGH SAMPLE ADD PROPER PRESERVATIVE IF NEED RECORD PRESERVATIVE USED, LOT NUMBER AND EXPIRATION ON THE COC PLACE SAMPLES ON ICE COMPLETE COC WITH SITE LOCATION, NAME OF SAMPLER, DATE AND TIME OF COLLECTION AND ANALYSIS REQUESTED GET SAMPLES TO THE AS SOON AS POSSIBLE 3

LEAD AND COPPER COMPLIANCE SAMPLING COLLECT SAMPLE FROM COLD FAUCET THAT IS FREE OF WATER SOFTENERS OR POINT OF USE FILTERS DO NOT REMOVE ANY SCREENS OR AERATION DEVICES IF COLLECTING A FIRST FLUSH ALLOW WATER TO SIT UNDISTURBED FOR 6 HOURS BEFORE COLLECTING SAMPLE DO NOT INTENTIONALLY FLUSH BEFORE COLLECTING THE SAMPLE OPEN THE FAUCET AND COLLECT THE FIRST WATER OUT OF THE TAP INTO A WIDE-MOUTH 1 L BOTTLE GET THE SAMPLES TO THE FOR ANALYSIS BIOLOGICAL SAMPLING BOTTLES STERILE 125 TO 150 ML PLASTIC BOTTLES PRESERVATIVE SODIUM THIOSULFATE COOL TO < 10 C (< 50 F) DO NOT FREEZE HOLD TIME IS VERY SHORT DELIVER SAMPLES TO LAB THE DAY OF COLLECTION SAMPLING INSTRUCTIONS --- 4

BIOLOGICAL SAMPLING INSTRUCTIONS REMOVE ANY ATTACHMENTS ON THE FAUCET AND FLUSH FOR 5 TO 6 MINUTES AND REDUCE FLOW TO STEADY STREAM WEAR GLOVES AND BREAK THE STERILITY SEAL DO NOT RINSE THE BOTTLE OPEN BOTTLE, HOLDING CAP BY THE EDGE AND DO NOT SET IT DOWN- DO NOT TOUCH THE INSIDE OF THE SAMPLE BOTTLE OR CAP FILL JUST ABOVE THE 100ML LINE WITH COLD WATER TAKING CARE NOT TO TOUCH THE FAUCET AND CAP IMMEDIATELY PLACE ON ICE AND DELIVER TO ON THE SAME DAY THINGS TO AVOID WITH BIOLOGICAL SAMPLING OUTDOOR FAUCETS FAUCETS CONNECTED TO CISTERNS, SOFTENERS, PUMPS, PRESSURE TANKS OR HOT WATER HEATERS NEW PLUMBING AND FIXTURES OR THOSE REPAIRED RECENTLY FAUCETS THAT ALLOW BOTH HOT AND COLD WATER TO COME THROUGH THREADED TAPS SWING SPOUTS FAUCETS POSITIONED CLOSE TO SINK OR GROUND LEAKY FAUCETS 5

UNPRESERVED CLASSICAL CHEMISTRY SAMPLING BOTTLES PLASTIC OR GLASS BOTTLE BUT PLASTIC IS PREFERRED PRESERVATIVE PLACE SAMPLE ON ICE 4 C ( 39.2 F) HOLDING TIME IS SHORT DELIVER TO THE THE SAME DAY SAMPLING INSTRUCTIONS RINSE THE BOTTLE WITH THE SAMPLE WATER AND FILL BOTTLE. PLACE ON ICE AND DELIVER TO THE PRESERVED CLASSICAL CHEMISTRY ANALYSIS BOTTLES PLASTIC OR GLASS BOTTLE BUT PLASTIC IS PREFERRED PRESERVATIVE SULFURIC ACID (H2SO4) PH <2 HOLDING TIME 28 DAYS PROTECTION. IF BOTTLES CONTAINS PRESERVATIVE- DO NOT RINSE JUST FILL WITH SAMPLE. OTHERWISE RINSE BOTTLES WITH SAMPLE, FILL AND ADD PRESERVATIVE. PLACE ON ICE AND DELIVER TO THE 6

CYANIDE SAMPLING BOTTLES PLASTIC OR GLASS BOTTLE BUT PLASTIC IS PREFERRED PRESERVATIVE 0.6 g ASCORBIC ACID if sample is chlorinated SODIUM HYDROXIDE (NaOH) PH >12 PLACE SAMPLE ON ICE 4 C ( 39.2 F) HOLDING TIME 14 DAYS PROTECTION. IF BOTTLES CONTAINS PRESERVATIVE- DO NOT RINSE JUST FILL WITH SAMPLE. OTHERWISE RINSE BOTTLES WITH SAMPLE, FILL AND ADD PRESERVATIVE. PLACE ON ICE AND DELIVER TO THE METAL ANALYSIS BOTTLES PLASTIC OR GLASS BOTTLE BUT PLASTIC IS PREFERRED PRESERVATIVE NITRIC ACID (HNO3) PH <2 HOLDING TIME 28 DAYS FOR MERCURY, 6 MONTHS FOR OTHER METALS PROTECTION. IF BOTTLES CONTAINS PRESERVATIVE- DO NOT RINSE JUST FILL WITH SAMPLE. OTHERWISE RINSE BOTTLES WITH SAMPLE, FILL AND ADD PRESERVATIVE. PLACE ON ICE AND DELIVER TO THE IF SAMPLES ARE NOT ACID PRESERVED, THEY MUST BE DELIVERED TO WITHIN 14 DAYS OF SAMPLING 7

OIL AND GREASE SAMPLING BOTTLES GLASS PICK UP FROM THE PRESERVATIVE HYDROCHLORIC ACID (HCl) HOLDING TIME 28 DAYS PROTECTION. IF BOTTLES CONTAINS PRESERVATIVE- DO NOT RINSE JUST FILL WITH SAMPLE. OTHERWISE RINSE BOTTLES WITH SAMPLE, FILL AND ADD PRESERVATIVE. PLACE ON ICE AND DELIVER TO THE HALOACETIC ACIDS (HAA5s) SAMPLING BOTTLES GLASS BOTTLE MUST BE USED PRESERVATIVE AMMONIUM CHLORIDE, PLACE ON ICE 4 C ( 39.2 F), KEEP SAMPLES ON ICE AND DO NOT FREEZE HOLDING TIME 14 OR 28 DAYS CHECK WITH PROTECTION. IF BOTTLES CONTAINS PRESERVATIVE- DO NOT RINSE JUST FILL WITH SAMPLE. OTHERWISE RINSE BOTTLES WITH SAMPLE, FILL AND ADD PRESERVATIVE. PLACE ON ICE AND DELIVER TO THE 8

CHLOROPHYLL SAMPLING BOTTLES PLASTIC BOTTLES ARE PREFERRED PRESERVATIVE PLACE ON ICE 4 C ( 39.2 F), KEEP SAMPLES IN THE DARK HOLDING TIME 48 HOURS SAMPLING INSTRUCTIONS RINSE THE BOTTLE WITH THE SAMPLE WATER AND FILL BOTTLE. PLACE ON ICE AND DELIVER TO THE TOTAL ORGANIC CARBON (TOC) SAMPLING BOTTLES GLASS PRESERVATIVE SULFURIC ACID (H2SO4) PH <2 HOLDING TIME 28 DAYS PROTECTION. IF BOTTLES CONTAINS PRESERVATIVE- DO NOT RINSE JUST FILL WITH SAMPLE. OTHERWISE RINSE BOTTLES WITH SAMPLE, FILL AND ADD PRESERVATIVE. PLACE ON ICE AND DELIVER TO THE 9

ORGANIC SAMPLING BOTTLES GLASS BOTTLE MUST BE USED PRESERVATIVE CHECK WITH THE, KEEP ON ICE 4 C ( 39.2 F), DO NOT FREEZE HOLDING TIME GENERALLY SHORT-CHECK WITH THE PROTECTION. IF BOTTLES CONTAINS PRESERVATIVE- DO NOT RINSE JUST FILL WITH SAMPLE. OTHERWISE RINSE BOTTLES WITH SAMPLE, FILL AND ADD PRESERVATIVE. PLACE ON ICE AND DELIVER TO THE 1. NAME DELIVERY TO THE WITH COC 2. ADDRESS 3. SAMPLER 4. DATE & TIME SAMPLE WAS COLLECTED 5. SAMPLE LOCATION 6. ANALYSIS REQUIRED 7. PRESERVATIVE USED 8. SIGNATURE, DATE AND TIME WHEN RELINQUISHED 1 2 3 4 5 7 8 6 10

REFERENCE EPA - QUICK GUIDE TO DRINKING WATER SAMPLE COLLECTION SECOND EDITION, UPDATE SEPTEMBER 2016 QUESTIONS 11