PROFESSIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA

Similar documents
INDUSTRY STANDARD OF THE PEOPLE S REPUBLIC OF CHINA

GB/T / IEC 60529:2013

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

Electronic controller of household gas burning appliances

GB/T / IEC 62423:2009

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

GB Translated English of Chinese Standard: GB

GB Translated English of Chinese Standard: GB

TB/T Translated English of Chinese Standard: TB/T RAILWAY INDUSTRY STANDARD

AQ Translated English of Chinese Standard: AQ WORK SAFETY INDUSTRY STANDARD

1st City Issues Tongji International Symposium City & Real Estate Risk Management 2010

QC/T Translated English of Chinese Standard: QC/T

YY / IEC :2004

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. QB/T Translated English of Chinese Standard: QB/T

GB/T / ISO/IEC :1992

GB/T / ISO/IEC :1992

GB/T Translated English of Chinese Standard: GB/T NATIONAL STANDARD OF THE

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YY Translated English of Chinese Standard: YY

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB/T Translated English of Chinese Standard: GB/T

Experimental Research of Air Source Heat Pump Frosting and Defrosting in a. Double Stage-Coupling Heat Pump

7th International Conference on Performance-based Fire and Fire Protection Engineering (ICPFFPE 2015)

Wet alarm valve stations

(ICPFFPE 2013) 2013 International Conference on Performance-based Fire and Fire Protection Engineering. Wuhan, China 16 November 2013

Code for Design of Clean Room

2nd International Symposium on Integrative Plant Biology (1st announcement)

WORLD TRADE ORGANIZATION

Design of the Fiber-optic Fence Warning System with Distributed Video Real-Time Display Function Qiang-yi YI and Zheng-hong YU *

Development of Bionic Air Cooler Used in High Temperature Coal Mine

Design and Realization for the Environmental Protection Type of Pig-Farm Model Based on the Sensor Technology

Simulation of Evacuation Process in a Supermarket with Cellular Automata

Two-Pipe Fiber Bragg grating Temperature Sensor Applied in Cable Trench and Cable Pit

GB/T Translated English of Chinese Standard: GB/T

State Grid Zhejiang Electric Power Corporation Electric Power Research Institute, Hangzhou, , China

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

Outdoor radon concentration in China

Modeling and Simulation on Temperature Control System of Farm Products Baking Equipment. Liu Jun, Jia Zhenwei, Guo Rongxing

Analysis of Eccentric Wear of Sucker Rod and Design of Multi-Stage Flexibility Stabilizer

The design of clothing washable labels based on NFC

2010 STUDENT LANDSCAPE ARCHITECTURE DESIGN COMPETITION PRIZE WINNERS

Classification for burning behavior of building materials and products

Research on the Monitor and Control System of Granary Temperature and Humidity Based on ARM

Luminaires Part 2-4: Particular requirements Portable general purpose luminaires

BS 5163 EN 1074 EN 1171 ISO 7259 AS 2638 FM UL

Experimental Study of Fouling Performance of Air Conditioning System with Microchannel Heat Exchanger

National Standard of the People's Republic of China

38-SDMS-01 SPECIFICATIONS FOR FAULT INDICATORS FOR UNDERGROUND DISTRIBUTION NETWORKS

INTERNATIONAL STANDARD NORME INTERNATIONALE

Design and Research of the Commercial Digital VRV Multi-Connected Units With Sub-Cooled Ice Storage System

Study on Intelligent Fire Fighting System for Large External Floating-roof Tank

Available online at ScienceDirect. Procedia Engineering 135 (2016 )

Investigation, Analysis and Solution of Higher Noise of Heat Pump Water Heater

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

HD 6/13 C. Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle. 3 Accessory storage

INTERNATIONAL STANDARD

COHERE DESIGN COMPANY LIMITED ALBERT CHENG CHAK LAM FOUNDER & MANAGING DIRECTOR

NEMA Standards Publication ICS (R 2007) Adjustable Speed Electrical Power Drive Systems

INTERNATIONAL STANDARD

AS/NZS :2003 Luminaires - Part 1: General requirements and tests


USER S MANUAL DN-2. Drain pump

INTERNATIONAL STANDARD

Research Progress on Plant Selection of Roof Greening. Shuang Liu+*, Chang-Cun Yuan +,Ting Xuan and Zi-Ya Chen

GB/T / ISO :2005

Part 2-55: Medical electrical equipment. Particular requirements for the basic safety and essential performance of respiratory gas monitors

Tail-end valve stations

ScienceDirect. Development progress of critical equipment in the CSNS cryogenic hydrogen system

ISO INTERNATIONAL STANDARD. Road vehicles Alarm systems for buses and commercial vehicles of maximum authorized total mass greater than 3,5 t

Beyond Expectation CHINA

ISO 7183 INTERNATIONAL STANDARD. Compressed-air dryers Specifications and testing. Sécheurs à air comprimé Spécifications et essais

INTERNATIONAL STANDARD

Specification for Design of Combustible Gas and Toxic Gas Detection and Alarm for Petrochemical Industry

ISO INTERNATIONAL STANDARD. Testing of valves Fire type-testing requirements. Essais des appareils de robinetterie Exigences de l'essai au feu

This document is a preview generated by EVS

Test Report No.: Page 2 of 14

Study on the North China Rural Water Supply Project O&M Cost Standard Rating

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

38-SDMS-03 SPECIFICATIONS FOR LV DIGITAL PANEL METERS

Fire Situations and Prevention Measures of residential building

INTERNATIONAL STANDARD

HD 5/12 C Plus. Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle.

Invitation to the 16th China Retail Industry Convention

Development and Application of Micro Channel Heat Exchanger for Heat Pump

TIANJIN UNIVERSITY CURRICULUM VITAE

Design of Humidity Monitoring System Based on Virtual Instrument

HD 5/12 C + Mobility. Accessory storage

SCOPE OF ACCREDITATION

This document is a preview generated by EVS

INTERNATIONAL STANDARD

The Application of Double-deck Inorganic Composite Fire Resisting Shutters in Constructional Engineering Bai-Xia ZHOU*

(GBOD 2012) Table of Contents

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

CATHAY-LINKS PRODUCT CATALOGUE MMII

A Study into the Standardization of Using Fire Detectors in Rail Vehicles for China

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 16: Sound system control and indicating equipment

ISO 9152 INTERNATIONAL STANDARD. Aerospace Bolts, with MJ threads, in titanium alloys, strength class MPa Procurement specification

INTERNATIONAL STANDARD

Automatic Waste Water Lifting Unit. Ama-Drainer-Box Mini. Type Series Booklet

SOUTH AFRICAN NATIONAL STANDARD

Transcription:

Translated English of Chinese Standard: JG/T285-2010 Translated by: www.chinesestandard.net Wayne Zheng et al. Email: Wayne@ChineseStandard.net; wr.zheng@gmail.com PROFESSIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA JG JG/T 285-2010 Douche to wash anus 坐便洁身器 How to BUY & immediately GET a full-copy of this standard? 1. www.chinesestandard.net; 2. Search --> Add to Cart --> Checkout (3-steps); 3. No action is required - Full-copy of this standard will be automatically & immediately delivered to your EMAIL address in 0~60 minutes. 4. Support: Sales@ChineseStandard.net. Wayne, Sales manager Issued on July 29, 2010 Implemented on January 1, 2011 Issued by Ministry of Housing and Urban-Rural Development of the People's Republic of China www.chinesestandard.net Page 1 of 18

Table of Contents Foreword...3 1 Scope...4 2 Normative references...4 3 Terms and definitions...4 4 Classification and type...5 5 Service conditions...6 6 Requirements...6 7 Test method...8 8 Inspection... 15 9 Marking, packaging, storage, transport and operation instructions... 17 www.chinesestandard.net Page 2 of 18

Foreword This Standard is proposed by the Standard quota Institute, the Ministry of Housing and Urban-Rural Development. This Standard is under the jurisdiction of the Housing Parts Standardization Technical Committee of the Ministry of Housing and Urban-Rural Development. This Standard is responsibly drafted by organizations: The Policy Research Center of the Ministry of Housing and Urban-Rural Development, Institute of kitchen and bathroom, China Real Estate and Housing Research Committee, China Building Sanitary Ceramics Association, Beijing Dulong Science and Technology Development Co., and Shanghai Hayes Sheng Electric Co., Ltd. Participating organizations of drafting this Standard: Xi'an Sanhua Liangzhi Electric Co., Ltd. Wenzhou Fuhuan Electronic Technology Co., Oulu Sha Limited, Zhejiang Yingshili Sanitary Ware Co., Hai Wei Electronic Sanitary Ware Co., Ltd. Zhejiang Star Bianjiebao Ltd., Hefei Rongshida Electronics Co., Ltd., Ningbo Shun Sanitary Ware Co., Ltd., Hai Kele Electronic Technology Co., Ltd. Shen Ying Pacific Group Ltd., Taizhou Simma Sanitary Ware Co. Ltd. Suzhou Ina Building Materials, TOTO (China) Co., Ltd., Zhejiang Special Intelligent Sanitary Ware Co., Ltd. Xiamen Water Bath, Zhongshan Mito Plastics Industry Ltd., Tangshan Ceramics (Group) Co., Ltd., Hangzhou Home Intelligent Sanitary Ware Co., Ltd. Wenzhou Positrons, Shanghai Weichu Technology Co., Ltd., Shenzhen Bo Electronics Co., Ltd., Fujian Beacon Sanitary Ware Co., Ltd., Shenzhen Ou Feng Electric Co., Ltd. Guangdong Continental Baths, Panasonic Home Appliances (Hangzhou) Co., Ltd., Foshan Shiwan Eagle Ceramics Co., Ltd. Beijing Rui Jian Kitchen Technology Research Center, and Ningbo Kitchenware Limited. The main drafters of this Standard: Lin Runquan, Tan Wanjiang, Mao Zhong, Jin Hongnian, Lin Tao, Pan Dingguo, Miao Bin, Liu Jun, Chen Fuhuang, Sun Zhitao, Ruan Chunyou, Yu Zhihong, Zeng Zhaoyuan, Xiao Fengsheng, Ma Zhonghui, Yao Jianqiang, Hong Guangming, Liu Rizhi, Xuan Jianqing, Jiang Haiying, Xu Haihong, Lin Xiaoyun, Huang Haojia, Wang Huiwen, Feng Liang, Yang Zhenchu, Cai Shijie, Li Wenming, Xiao Zhiyong, Huang Min, Chen Fang Qing, Zhou Bin, and Mai Zhuorong. www.chinesestandard.net Page 3 of 18

Douche to wash anus 1 Scope This Standard specifies the terms and definitions, classification, requirements, test methods, inspection, marking, packaging, storage, transport and operation instructions of the douche to wash anus (hereinafter referred as the douche). This Standard applies to douche to wash anus used in collocation with pedestal pan in toilet. 2 Normative references The articles contained in the following documents become part of this Standard when they are quoted herein. For the dated documents so quoted, all the modifications (excluding corrections) or revisions made thereafter shall not be applicable to this Standard. For the undated documents so quoted, the latest editions shall be applicable to this Standard. GB/T 191 GB/T 1019 Packaging - Pictorial marking for handling of goods (ISO 780: 1997, MOD) General requirements for the package of household and similar electrical appliances GB/T 2829-2002 Sampling procedures and tables for periodic inspection by attributes (Apply to inspection of process stability) GB/T 3768-1996 Acoustics-Determination of sound power levels of noise sources using sound pressure-survey method using an enveloping measurement surface over a reflecting plane GB 4208-2008 Degrees of protection provided by enclosure (IP code) (IEC 60529: 2001, IDT) GB 4706.53 Household and similar electrical appliances - Safety - Particular requirements for toilets GB 5749 GB 6952 Standards for drinking water quality Sanitary wares JC/T 764-2008 WC seats 3 Terms and definitions For the purpose of this Standard, the terms and definitions defined hereunder and in GB/T 4706.53 apply. 3.1 Douche to wash anus www.chinesestandard.net Page 4 of 18

Performance of toilet cover and seat ring shall comply with JC/T 764-2008, in addition to mechanical strength (including the opening/closing test, slow-fall life-span test, static load, etc.). 6.11 Safety performance 6.11.1 Safety performance shall comply with the requirements of GB 4706.53; in which the requirements on mechanical strength, reliability and structure shall be replaced with those specified in 6.11.2, 6.11.3 and 6.11.4. 6.11.2 Mechanical strength 6.11.2.1 Strength of seat ring After the test specified in 7.12.2.1, the douche shall have no crack, breakage, deformation, disconnection and other abnormalities. 6.11.2.2 Strength of toilet cover After the test specified in 7.12.2.2, the douche shall have no crack, breakage, deformation and other abnormalities. 6.11.3 Reliability After the test specified in 7.12.2, all parts of the douche shall run normally. 6.11.4 Structure a) The douche shall be able to be installed on pedestal pan specified in GB 6952; b) In maintenance and repair, all parts shall be easy to remove, replace. Under normal service condition and good maintenance management, the douche shall have good durability without leakage; c) Nominal diameter of inflow port of the douche shall be DN15 or DN20, and connecting thread shall be G1/2 or G3/4 ; d) The douche shall be equipped with anti-dry heating equipment; e) For the douche with water tank heated, it shall be installed with non-operational drainage device; f) Location of nozzle shall meet the requirements of washing, and it shall also meet the requirement that it shall not be tainted by falling dirt under normal service condition, and it shall also have self-cleaning function. 7 Test method 7.1 Test conditions Test conditions of douche shall comply with the following provisions: www.chinesestandard.net Page 8 of 18

7.8 Test of water impact prevention performance Under normal service condition of the douche, fill the device with water, as shown in Figure 2, with water at hydrodynamic pressure of 0.15MPa (as indicated on pressure machine 1) for 30s, then quickly turn off water-valve mechanism of the douche, and measure pressure at this point (as indicated on pressure machine 2). Range of pressure gauge: 0-2MPa, 0-2.5MPa or 0-3.5MPa. Nominal diameter Φ40mm Nominal diameter Φ15mm 1 Pressure machine; 2 Measuring point for temperature; 3 Regulating valve; 4 Air compressor; 5 Feed water pump; 6 Douche. Figure 2 Water impact performance test device 7.9 Performance of backflow prevention Mount backflow prevention device of douche at the position as shown in Figure 3, apply 2 10 4 Pa pressure at outlet of backflow prevention device, and then observe the backflow of backflow prevention device after 1min. www.chinesestandard.net Page 11 of 18

1 Plywood; 2 Rubber plate. Figure 7 Strength test of toilet cover 7.12.3 Reliability test After passing the test specified in 7.12.1, douche shall be tested for a total of 20000 cycles, of which each cycle is consisted of - the anus washing for 15s, local washing for 15s, and warm-up drying for 30s. The appearance quality shall be checked and tested for withstanding the electric strength, after the test is completed. 7.12.4 Structure The nominal diameter of douche water inlet is measured by the graduated caliper with accuracy of 1mm, while other items are checked visually. 8 Inspection 8.1 Inspection classification The inspection is classified into exit-factory inspection and type inspection. 8.2 Exit-factory inspection Exit-factory inspection items are shown in Table 2. 8.3 Type inspection 8.3.1 Type inspection item Type test items are shown in Table 2. 8.3.2 Type inspection shall be conducted in case of one of the following conditions: a) When the new products are verified for its trial-manufacture and final design; www.chinesestandard.net Page 15 of 18

Performance of water pressure resistance 6.6 A Performance of water impact prevention 6.7 A Performance of backflow prevention 6.8 A Performance of negative pressure 6.9 A Toilet cover and seat ring 6.10 A Related items in GB 4706.53 6.11.1 A Safety Strength of seat ring 6.12.2.1 A performance Strength of toilet cover 6.12.2.2 B Reliability 6.11.3 A Structure 6.11.4 A Note: Only "Leakage current and electric strength" in GB 4706.53 shall be the exit-factory inspection item. 9 Marking, packaging, storage, transport and operation instructions 9.1 Marking Product markings shall include at least the following contents: a) Product name and type; b) Name and trademark of the manufacturer; c) Rated voltage or rated voltage range, unit: volt (V); d) Rated frequency or rated frequency range, unit: hertz (Hz); e) Rated power, unit: watt (W); f) IP code of waterproofing grade. 9.2 Packaging Upon inspection, the qualified product packaging shall meet relevant provisions of GB/T 1019; exit-factory inspection certificate, operation instructions, attachments, warranty card, maintenance record card and contact information of manufacturer shall be accompanied in the packing container. The packaging mark diagram outside the packaging container shall comply with the provisions of GB/T 191. 9.3 Storage and transport 9.3.1 Storage The storage warehouse for products shall have flat ground, good ventilation and have no corrosive gases. Products of different specifications and types shall be stacked up separately and orderly. 9.3.2 Transport Inclination, inversion, rain, snow and severe collision shall be avoided during transport, and throwing is www.chinesestandard.net Page 17 of 18

forbidden during loading and unloading. 9.4 Operation instructions The operation instructions of the douche shall include the following contents: a) Performance, function introduction of the product; b) Related matters on installation methods; c) Related matters on operation methods; d) Matters that require special attention in operation; e) Related matters on routine maintenance inspection; f) Fault repair and other contact matters; g) Safety precautions. www.chinesestandard.net Page 18 of 18