Laboratory Gas Sensor Solutions

Similar documents
aspida User Manual T: +44 (0) F: +44 (0) W: E:

Aspida. User Manual. Commercial in Confidence

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

10yr O2NE & Safe-Ox. User Manual

IGD.CO.UK

Dräger PointGard 2100 Detection of toxic gases and vapours

Ax60+ Multi-Gas. Service Manual

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Polytron 5720 IR Detection of carbon dioxide

CellarSafe. Carbon Dioxide and Oxygen Safety Monitor

Personal & Portable Gas Monitors

Dräger Pac 6000 Single-Gas Detection Device

Selection Guide To Temperature Controllers

APPLICATION DATA SHEET

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger X-am 7000 Multi-Gas Detection

Dräger Pac 7000 Single-Gas Detection Device

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Pac 8000 Single-Gas Detection Device

AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

Analox Safe-Ox/Safe-Ox He

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Pac 8500 Single-Gas Detection Device

Oxygen Monitor Operating Manual

Dräger X-am 2500 Multi-Gas Detection

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

P R O D U C T D ATA S H E E T

Ammonia Detection System Codes and Design Specifications

GAS ANALYSIS / DETECTION Gas Detector

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Inc Series Digital Gas Detector/Controller. Operation Manual

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Dräger QuadGard Control System

Dräger X-am 5000 Multi-Gas Detection

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger X-am 2500 Multi-Gas Detector

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

Danfoss gas detection unit Type GD Heavy Duty

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 8700 IR Detection of flammable gases and vapors

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

APPLICATION DATA SHEET

Dräger X-am 7000 Multi-Gas Detection

Oxygen (O2) Single-Point Gas Detection System

Monitores Personales. Personal Monitor

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Dräger PIR 3000 Detection of flammable gases and vapours

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

APPLICATION DATA SHEET

R-Series Wiring Devices

Recalibrate the way you look at gas detection

ANALOX 3000 Carbon Monoxide Monitor

EXAMPLES OF HOW TO ORDER

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

EXAMPLES OF HOW TO ORDER

Dräger PIR 7200 Detection of toxic gases and oxygen

1 of 7 UNIVERSAL FIRE ENGINEERING (ALOR SETAR) SDN BHD. EN3 Water & Foam Type Fire Extinguisher. Portable Carbon Dioxide Fire Extinguisher

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Dräger Pac 5500 Single-Gas Detection Device

English US User s Manual

Dräger Pac 6000 Single-Gas Detector

CO2 & Oxygen Monitor Operating Instructions Model: RAD

Polytector III G999 for Ex zone 0

Electrical Installations Design, Selection, Erection and Inspection

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Version Inc Series Digital Gas Detector/Controller. Operation Manual

Dependable Solutions for Gas Detection

Unipoint controller. The Unipoint, a simple DIN rail mounted controller

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Products and performance

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

PERSONAL COMBUSTIBLE GAS DETECTOR

For the Safety of Your

ANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

PROCESS ANALYSERS. SERVOFLEX Micro i.s. (5100is) Gas Analyser. Operator Manual. Revision:

Dräger Polytron 8200 Stationary gas detector (CatEx)

P R O D U C T D ATA S H E E T

PROCESS ANALYSERS. SERVOFLEX MiniMP (5200) Gas Analyser. Operator Manual. Part Number: A Revision: 8 Language: UK English

Dräger Bump Test Station Calibration and Bump Testing

Single Gas Monitor 777

KANE-ALERT-CO 2 Monitor with Temperature

R.I.S. (Remote Intelligent Sensor)

Understanding the practicalities of using gas detectors in confined spaces

Dräger X-am 5000 Multi-Gas Detector

Multi-Gas-Controller MGC2

Danfoss gas detection units

MK10 CO Safety System Connected to Central Unit

Transcription:

Laboratory Gas Sensor Solutions

Ax60+ Multi-gas CO₂ & 0₂ Safetry Monitor The Ax60+ is a wall-mountable, multi-gas safety device for monitoring carbon dioxide and oxygen. Based on the popular Ax60 CO2 detector, the new Ax60+ can also be supplied with O2 sensor modules which provides an early warning of both oxygen depletion and oxygen enrichment. The CO2 and O2 sensors are interchangeable and can be fully integrated as part of a multi-point, multi-gas detection and alarm system. Central Display The CO2 sensor is set by default to trigger a low-level alarm at 1.5% CO2, an evacuation alarm at 3% CO2 and a time-weighted average alarm of 0.5% CO2 measured over eight hours. The O2 sensor is set by default to trigger low-going alarms at both 19.5% and at 18% and a high-going alarm at 23%. The alarm setpoints can be changed by the user. Warnings are announced by high-visibility strobe lights and high-volume sounders. System Warm-up time: 40 seconds Operating temperature range: -5 C to +50 C, +23 F to +122 F Approvals: CE, EN50270, IEC 61010 (UL), DIN 6653 (TUV) * You can have 4 alarms per sensor, to a maximum of 8 alarms per system. 175mm x 67mm x 106mm (LxWxH) Display: LCD dot matrix (backlit) Relays: 2 x configurable relays, rated for 1 A/30 V AC/DC IP Rating: IP54 Maximum power consumption: <24W Power supply accepts inputs from: 100-200V ~ 1A Alarm CO₂ Sensor O₂ Sensor 72mm x 45mm x 132mm (LxWxH) Strobe: white LED strobe > 100 cd (optional blue, red and amber filters) Sounder: min 80 dba @ 3 m (9.8 feet) IP Rating: IP55 72mm x 52mm x 132mm (LxWxH) Gas detected: carbon dioxide Measurement technique: infrared Range: 0.1% to 5% Default alarm setpoints: 0.5% (8hour TWA), 1.5%, 3.0% IP Rating: IP55 Response time: (T₉₀) <30 seconds 72mm x 52mm x 132mm (LxWxH) Gas detected: oxygen Measurement technique: electrochemical cell Range: 0.1% to 25% Default alarm setpoints: 18.0% (low going), 19.5% (low going), 3.0% (high going) IP Rating: IP55 Response time: (T₉₀) <30 seconds 02

O₂NE+ Oxygen Depletion Monitor The O2NE+ is a simple to use and maintain ambient oxygen depletion monitor and sensor, ideal for monitoring oxygen levels where inert gases such as N2, Ar or He pose a risk of depleting O2 levels in ambient air. It comprises of a wall mounted main sensor unit and a repeater. It is ranged from 0 to 25% O2 and has 2 audio/ visual alarms. The sensor is long life and calibration adjustment is only required once the unit is initially installed and following a cell replacement and can be achieved using certified air*. We recommend a proof test is carried out every 12 months. The instrument uses an electrochemical cell together with state of the art technology, built in an IP65 splash proof housing and is designed to provide long, trouble free service, with minimum maintenance. The O2NE+ has two pre-set alarm levels at 19.5% and 18% O2. The oxygen sensor used is not cross sensitive to helium so will measure correctly in the presence of a helium atmosphere. This means that the sensor can be safely used to detect oxygen displacement by helium gas leaks. The O2NE+ is installed in areas where an inert gas is being used or stored to provide a warning should the oxygen levels deteriorate to an unsafe level. The repeater is located at the entrance to the room, highlighting the danger to personnel before they enter. * The O2NE+ is a precision instrument and needs to be handled with care Oxygen Monitor Alarm Repeater O2 range: 0.1 to 25% Sensor accuracy: better than ± 0.75% O2 over 5.0 to 25.0% O2 Response time (T90): <60 seconds Operating temperature: 0 to +40 C (+32 to +104 F) Temperature effect: 0.2% of reading/ C or 0.1115% of reading/ F Atmospheric pressure range: 811 to 1050 mbar absolute Warm up time: 10 seconds to normal operation, prior to calibration allow 2 hours to achieve full accuracy Dimensions: central unit = 175 x 105 x 75 mm, alarm repeater = 155 x 72 x 45 mm Weight: central unit = 600g, alarm repeater = 150g IP rating: IP65 for central unit and alarm repeater, unless the alarm repeater is quick connect then it is IP43 Sensor type: electrochemical cell Sensor life: up to 7 years in air Display: 4 digit LCD Alarms: 2 x alarm visual indicators, 1 x system fault indicator, 1 x status indicator, common audible alarm Alarm Sounder: min 75dBA Relays: one or two optional alarm relays with changeover contacts assigned to alarm 1, alarm 2 or system fault. Contact rating 240 V AC or 30 V DC at up to 2 A, contacts are non-latching fail-safe Output: 2 wire, 4 to 20 ma (max load 150 Ω) Power supply options: 210 to 250 V AC supply, 110 to 120 V AC supply, 9-24 V DC supply 03

Safe-Ox+ Oxygen Depletion & Enrichment Monitor The Safe-Ox+ is an ambient oxygen enrichment and depletion monitor which is simple to use and maintain. The Safe-Ox+ consists of a wall mounted main sensor unit and a repeater. It is ranged from 0 to 25% O2 and has 1 low and 1 high audio/visual alarm. The sensor has a long life and calibration adjustment is only required once the unit is initially installed and following a cell replacement and can be achieved using certified air*. We recommend a proof test is carried out every 12 months. Industries that store and operate with high levels of O2 need to detect and monitor the levels of oxygen - should there be a leak of enriched O2 this could prove to be a fire risk. Enriched oxygen is used in a variety of industries and applications such as: commercial dive systems, hyperbaric oxygen therapy (HBOT), gas production and gas blending stations, medical and laboratory gases such as nitrous oxide/oxygen mixes, sulphuric and nitric acid manufacture, mining, steel manufacture and metal refining, aquaculture and glass manufacture. The Safe-Ox+ provides a high O2 alarm ideal if you are using pure oxygen, to protect you from O2 enrichment. If there is a leak or build up of inert gas such as nitrogen, argon or helium the Safe-Ox+ can also warn of oxygen depletion. The Safe-Ox+ can be wall mounted at normal working head height in the gas storage room, or where enriched O2 is piped. The unit comes with one repeater as standard which is located at the entrance to the room. The Safe-Ox+ has an integral pressure sensor that allows the device to automatically compensate for local pressure changes. Oxygen Monitor Alarm Repeater O2 range: 0.1 to 25% Sensor accuracy: better than ± 0.75% O2 over 5.0 to 25.0% O2 Response time (T90): <60 seconds Operating temperature: 0 to +40 C (+32 to +104 F) Temperature effect: 0.2% of reading/ C or 0.1115% of reading/ F Atmospheric pressure range: 811 to 1050 mbar absolute Warm up time: 10 seconds to normal operation, prior to calibration allow 2 hours to achieve full accuracy Dimensions: central unit = 175 x 105 x 75 mm, alarm repeater = 155 x 72 x 45 mm Weight: central unit = 600g, alarm repeater = 150g IP rating: IP65 for central unit and alarm repeater, unless the alarm repeater is quick connect then it is IP43 Sensor type: electrochemical cell Sensor life: up to 7 years in air Display: 4 digit LCD Alarms: 2 x alarm visual indicators, 1 x system fault indicator, 1 x status indicator, common audible alarm Relays: one or two optional alarm relays with changeover contacts assigned to alarm 1, alarm 2 or system fault. Contact rating 240 V AC or 30 V DC at up to 2 A, contacts are non-latching fail-safe Output: 2 wire, 4 to 20 ma (max load 150 Ω) Power supply options: 210 to 250 V AC supply, 110 to 120 V AC supply, 9-24 V DC supply 04

Aspida 0₂, CO₂ or Dual Portable Safety Monitor The Aspida is a robust, high specification personal CO2/O2 monitor which can be worn on a belt or even wall mounted as a backup to a primary safety system. Offering audio/visual alarms, data logging and a man down alarm for lone workers, it is an ideal solution to protect staff from the dangers of a leak of carbon dioxide or nitrogen. The Aspida is available as a stand-alone CO2 or O2 monitor, or as a dual CO2/O2 monitor, ideal where a combination of CO2/O2 and inert gases are used. It has a high resolution display which gives clear readings in all light conditions and is packed into a durable, water resistant enclosure. Standards such as EH40 in Europe mandate that employees are not exposed to potentially dangerous levels of CO2 as it is a highly toxic gas in relatively small quantities. The Aspida is an affordable, easy to operate CO2 monitor and is ideal for ensuring personal safety in the areas where gas is piped or stored. The same standards also require that consideration is given to asphyxiant dangers where inert gases such as nitrogen, argon or helium are used, a portable, personal monitor, like the Aspida, may be appropriate following a risk assessment. Users of the Analox Aspida will never need to worry about maintenance schedules again. The Aspida uses intelligent software which lets you know what requires maintenance and when - ensuring optimum performance of your unit. The software also allows 2 employees to share the unit, ideal for 24/7 split shift patterns. It is also the first gas alarm to incorpo- rate a man down/panic alarm. The man down alarm will sound a loud (110 db) audible alarm in the event of an employee collapsing. Alternatively, an employee can trigger the alarm manually in a panic situation. System O₂ Sensor Operating temperature: 5 C to +50 C Sensor type: electrochemical Display: high-visibility, Organic Light Emitting Diode (OLED) Range: 0.1% to 25% Alarm horn: 95dB @ 30cm (110db - man-down alarm) LED indicators: 1 x Green - OK, 1 x Amber - Fault, 1 x Red - Alarm Internal data log: 1 log every 30 seconds for at least 7 days of continuous use Batteries: 2 x NiMH 2100 mah AA batteries Battery discharge time: 15 hours under normal operation (passive atmospheric monitoring, minimal user interaction, no alarms) Accuracy (at standard temperature and pressure): ±3% of full scale between 0.1% and 25% Response time: T90 <30 seconds Sensor life span: 2 years (expected) Battery lifespan: 2 years Battery charge time: 4.5 hours (from flat) Charge power supply rating: 9 V DC - 0.55A Electronics warranty: 2 years CO₂ Sensor IP rating: IP65 Sensor type: Analox infrared MIR Dimensions: 127 x 44 x 80 mm (LxDxW) Range: 0.1% to 5% Weight: Dual 335g, O2, 350g, CO2 335g Accuracy (at standard temperature and pressure): ±2% of full scale between 0.01% and 2.5%, ±3% of full scale between 2.5% and 5.0% Response time: T90 <60 seconds Sensor life span: 5 years 05

Example Laboratory O₂NE+ He, N₂, Ar Ax60+ Pure O₂ Safe-OX+ 06 CO₂

Singapore Malaysia Myanmar No.52 Senang Crescent, Singapore 416619 KL Office: Unit B-1-10, Block B, No. 2, Jalan PJU 1A/7A, Oasis Square, Ara Damansara, 47301 Petaling Jaya, Selangor Darul Ehsan, Malaysia. No(81/2), 7th Street, Than Thu Mar Road, (14/1)Quarter, South Okkalapa Township, 11091 Yangon, Myanmar. Advancelab (S) Pte Ltd Tel: +65 6448 8255 Fax: +65 6448 9833 Email: info@advancelab.com.sg Advancelab Sdn Bhd Tel: +603 7831 0188 Advancelab Scientific & Engineering Co., Ltd Tel: +95 (1) 572393 / +95 (9) 779753802 Fax: +95 (1) 572393 Fax: +603 78310588 Email: info-my@advancelab-global.com Email: info-mm@advancelab-global.com Johor Factory: No. 3388, Jalan Pekeliling Tanjung 27/2, Kawasan Perindustrian Indahpura, 81000 Kulaijaya, Johor, Malaysia. Tel: +607 660 8877 Fax: +607 660 8866 Email: info-my@advancelab-global.com Indonesia Thailand Advancelab (Thailand) Co., Ltd. Advancelab FZCO Jl. Boulevard Raya Blok QJ 5 No. 23 Kelapa Gading, Jakarta Utara, 14240 Indonesia 147 / 170-171 Baromrajchonnanee Road, Arunamarin Bangkoknoi, Bangkok 10700, Thailand. No.FZJOAB1310 Fax: +6221 45854570 Fax: +66 2 884 6441 PT. Advancelab Saintifik Tel: +6221 45854569 / +6221 45854570 Email: info-id@advancelab-global.com Tel: +66 2 884 9480 U.A.E (Dubai) Jafza One, Jebel Ali Dubai United Arab Emirates Email: info@advancelab.com.sg Email: primasci@advancelab-global.com Vietnam Advancelab Pte Ltd 83/10 Bach Dang Street, Ward 2, Tan Binh District, Ho Chi Minh City 700000, Vietnam Tel: +84 8 2244 6300 Fax: +84 8 3845 1974 Email: info@advancelab.com.sg Singapore Malaysia Myanmar Indonesia Thailand U.A.E Vietnam