TECHNICAL DATA. * Metric K-factor measurement shown is in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0.

Similar documents
freedom residential concealed pendent sprinkler vk474 (K5.8)

freedom residential concealed pendent lead free sprinkler

FREEDOM RESIDENTIAL CONCEALED PENDENT LEAD FREE SPRINKLER VK4570 (K4.9) TECHNICAL DATA

freedom residential concealed pendent sprinkler VK488 (K3.0)

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK498 (K5.8) TECHNICAL DATA

TECHNICAL DATA. The Viking Corporation s Web site at Overall Length (Sprinkler Body): 2-5/16 (59 mm)

FREEDOM RESIDENTIAL CONCEALED HORIZONTAL SIDEWALL SPRINKLER VK480 TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK457 (K4.9) TECHNICAL DATA

Page 1 of 7. Form No. F_ Rev Replaces Form No. F_ Rev 17.1 (added 205deg version)

TECHNICAL DATA OBSOLETE

Page 1 of 7. Replaces Form No. F_ Rev 16.3 (Added 16X22 and 18X20 coverage areas)

freedom residential concealed pendent Sprinkler vk458 (K7.4)

MIRAGE EC/QREC OH-ELO CONCEALED PENDENT SPRINKLER VK538 (K11.2) TECHNICAL DATA

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) TECHNICAL DATA

TECHNICAL DATA vk470 (K3.0)

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK479 (K3.0) TECHNICAL DATA

freedom residential pendent sprinkler vk466 (K5.2)

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202.

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

Standard Spray concealed horizontal sidewall sprinkler VK481

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

STANDARD/quick. Sprinkler 42o. August 8, 2011

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK486 (K4.0) TECHNICAL DATA

Quick response concealed horizontal sidewall sprinkler VK481

TECHNICAL DATA. Cover Plate Assembly must be ordered separately:

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK460 (K5.8) TECHNICAL DATA

TECHNICAL DATA. Page 1 of 5

sprinkler vk538 (K11.2)

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

HORIZON MIRAGE QUICK RESPONSE LARGE ORIFICE CONCEALED PENDENT SPRINKLER VK406 TECHNICAL DATA

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

mirage standard response concealed pendent sprinkler vk492 (K5.6)

freedom residential Upright sprinkler vk467 (k4.9)

December 14, 2015 Page 1 of 7 TECHNICAL DATA

FREEDOM RESIDENTIAL PENDENT LEAD FREE SPRINKLER VK4700 (K3.0) TECHNICAL DATA

Form No. F_ Rev 14.1 Page 1 of 6 TECHNICAL DATA

freedom residential flush pendent sprinkler vk476 (K4.9)

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

freedom residential horizontal sidewall lead free sprinkler VK4840 (k4.2)

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

TECHNICAL DATA. Viking Technical Data may be found on Minimum Operating Pressure: Refer to the Approval Chart.

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

HORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA

QUICK RESPONSE DRY CONCEALED PENDENT SPRINKLER VK194 TECHNICAL DATA

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

quick response sprinkler vk194 Sprinkler 104j January 1, 2011

TECHNICAL DATA OBSOLETE

standard response Fusible Link Upright sprinkler VK204 (K8.0)

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

standard response/ quick response extended coverage

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA

TECHNICAL DATA. Page 1 of 6

standard response large orifice dry

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0)

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

freedom residential horizontal sidewall sprinkler Vk450 (k4.2)

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

quick response extra-large orifice upright sprinkler vk531 (storage-density/area)

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

standard response dry horizontal sidewall sprinklers

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

standard response elo upright sprinkler

standard response dry horizontal sidewall sprinklers

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA

quick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279)

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

TECHNICAL DATA. Refer to Approval Chart 1 and FM Design Criteria for FM Approval requirements that must be followed.

TECHNICAL DATA OBSOLETE

microfast quick response Pendent sprinkler VK302 (K5.6)

TECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

EC/QREC ORDINARY HAZARD UPRIGHT SPRINKLER VK570 (K14.0) TECHNICAL DATA

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA

TECHNICAL DATA OBSOLETE

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA

micromatic Standard response Horizontal Sidewall sprinkler

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

microfast sr/qr extended coverage pendent sprinkler

Microfast quick response Fusible element hsw sprinkler

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

micromatic standard response Upright sprinkler VK100 (K5.6)

Transcription:

Page 1 of 6 Telephone: 269-95-9501 Technical Services: 77-3-56 Fax: 269-1-0 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Freedom Residential Concealed Pendent Sprinkler VK7 is a small high-sensitivity solder link and lever residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 5. (3.6 metric*), allows the sprinkler s efficient use of available water supplies for the hydraulically designed fire-protection system. The fast response operating element and special deflector combine speed of operation and areas of coverage to meet residential sprinkler standards. The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile small-diameter cover assembly installed flush to the ceiling. The twopiece design allows installation and testing of the sprinkler prior to installation of the cover plate. The push-on, thread-off design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to ½ (12.7 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS UL Listed (C-UL-US-EU): Category VKKW Refer to the Approval Charts on pages and Design Criteria for C-UL-US-EU Listing requirements that must be followed. 3. Specifications: Available since 2009. Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (3.5 bar). Thread size: 1/2 (15 mm) NPT Nominal K-Factor: 5. U.S. (3.6 metric*) * Metric K-factor measurement shown is in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C00 or QM Brass Viking Technical Data may be found on Deflector: Phosphor Bronze UNS-C51000 Deflector Pins: Stainless Steel UNS-S30200 The Viking Corporation s Web site at Button: Brass UNS-C36000 http://www.vikinggroupinc.com. Seat Assembly: Brass UNS-C300 The Web site may include a more recent Compression Screw: Brass UNS-C36000 edition of this Technical Data Page. Fusible Element Assembly: Beryllium Nickel, coated with black acrylic paint Levers: Stainless Steel UNS-S300 Lever Bar: Copper Alloy UNS-C72500 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel UNS-G1000, Finish: Clear Chromate over Zinc Plating Shipping Cap: Polyethylene Cover Plate Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C2600 Spring: Beryllium Nickel Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Freedom Residential Concealed Pendent Sprinkler VK7 and Cover Plate Assembly must be ordered separately: Sprinkler: Part Nos. 15790AC for Brass finish and 15790JNC for ENT finish (includes a 5 F (7 C) rated sprinkler with a protective plastic cap covering the unit). (Added EU Listing)

Page 2 of 6 Telephone: 269-95-9501 Technical Services: 77-3-56 Fax: 269-1-0 Email: techsvcs@vikingcorp.com Cover Plate Assemblies: Base Part No. 1350 (2-3/ diameter), Base Part No. 1362 (3-5/ diameter), or Base Part No. 1539 (square cover plate, 3-5/ diameter) Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/I, Painted Black = /B Temperature Suffix: 135 F (57 C) = A For example, cover 1350 with a Polished Chrome finish and a 135 F (57 C) temperature rating = 1350FA. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Sprinkler Accessories section of the Viking data book.) Sprinkler Wrenches**: A. Heavy Duty Part No. 13623W/B (available since 2006), or B. Head Cabinet Wrench Part No. 13619*** (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 112 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 167 (available since 2007) **Requires a ½ ratchet (not available from Viking). ***Also optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971). INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the fusible element to disengage releasing the sealing assembly. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pressure at the sprinkler to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK7 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation.. GUARANTEE For details of warranty, refer to Viking s current list price schedule or contact Viking directly. Sprinkler Temperature Classification TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Nominal Temperature Rating 1 Maximum Ambient Ceiling Temperature 2 Required Cover Assembly Temperature Rating Cover Plate Base Part No. 3 Large Cover Plate Base Part No. 3 Square Cover Plate Base Part No. 3 Ordinary 5 F (7 C) 100 F (3 C) 135 F (57 C) 1350 1362 1539 Sprinkler Finishes: Brass and ENT Cover Plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Corrosion Resistant Coatings : ENT 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed.

Page 3 of 6 Telephone: 269-95-9501 Technical Services: 77-3-56 Fax: 269-1-0 Email: techsvcs@vikingcorp.com Approval Chart 1 Viking VK7, 5. K-Factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to NFPA 13, 13R or 13D 2013 Editions Sprinkler Base Part Number 1 SIN NPT Thread Size Nominal K-Factor Inches mm U.S. metric 2 Maximum Water Working Pressure 15790AC VK7 1/2 15 5. 3.6 175 psi (12 bar) Max. Coverage Area 6 Width X Length Ft. X Ft. (m X m) Ordinary Temp Rating (5 F/7 C) Flow 6 GPM (L/min) Pressure 6 PSI (bar) Deflector to Ceiling Installation Type Listings and Approvals 3 NYC NSF Minimum Spacing Ft. (m) 12 X 12 (3.7 X 3.7) 1 X 1 (.3 X.3) X (.9 X.9) 1 X 1 (5.5 X 5.5) 19 (71.9) 10.7 (0.7) Refer to Figure 2 Concealed with Cover Plate Assembly See See Footnote 7 Footnote 5 and 9 -- (2.) 20 X 20 (6.1 X 6.1) 23 (7.1) 15.7 (1.1) 1 Part number shown is the base part number. For complete part number, refer to current Viking price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. Listed by Underwriter s Laboratories, Inc. for use in the U.S., Canada, and European Union. 5 Meets New York City requirements, effective July 1, 200. 6 For areas of coverage smaller than shown, use the Flow and Pressure for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum Flow and Pressure used. 7 Cover Temperature Rating is 135 F (57 C). Cover Part No. 1350 1, 1362 1 (large diameter), or 1539 1 (square cover plate). Other paint colors are available on request with the same listings as the standard finish colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. 9 Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black.

Page of 6 Telephone: 269-95-9501 Technical Services: 77-3-56 Fax: 269-1-0 Email: techsvcs@vikingcorp.com Approval Chart 2 Viking VK7, 5. K-Factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to NFPA 13, 13R or 13D 2013 Editions Sprinkler Base Part Number 1 SIN NPT Thread Size Nominal K-Factor Inches mm U.S. metric 2 Maximum Water Working Pressure 15790JNC VK7 1/2 15 5. 3.6 175 psi (12 bar) Max. Coverage Area 5 Width X Length Ft. X Ft. (m X m) Ordinary Temp Rating (5 F/7 C) Flow 5 GPM (L/min) Pressure 5 PSI (bar) Deflector to Ceiling Installation Type Listings and Approvals 3 C-UL-US- EU NYC NSF Minimum Spacing Ft. (m) 12 X 12 (3.7 X 3.7) 1 X 1 (.3 X.3) X (.9 X.9) 1 X 1 (5.5 X 5.5) 19 (71.9) 10.7 (0.7) Refer to Figure 2 Concealed with Cover Plate Assembly See 6,, and 9 -- -- (2.) 20 X 20 (6.1 X 6.1) 23 (7.1) 15.7 (1.1) 1 Part number shown is the base part number. For complete part number, refer to current Viking price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. Listed by Underwriter s Laboratories, Inc. for use in the U.S. and Canada. 5 For areas of coverage smaller than shown, use the Flow and Pressure for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum Flow and Pressure used. 6 Cover Temperature Rating is 135 F (57 C). Cover Part No. 1350 1, 1362 1 (large diameter), or 1539 1 (square cover plate). 7 Other paint colors are available on request with the same listings as the standard finish colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 7. 9 C-UL-US-EU Listed as corrosion resistant.

Page 5 of 6 Telephone: 269-95-9501 Technical Services: 77-3-56 Fax: 269-1-0 Email: techsvcs@vikingcorp.com DESIGN CRITERIA (Also refer to the Approval Charts.) UL Listing Requirements (C-UL-US-EU): When using Viking Residential Concealed Pendent Sprinkler VK7 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of coverage and minimum water supply requirements shown in the Approval Charts. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in the Approval Charts on data pages for NFPA 13D and NFPA 13R applications for each listed area of coverage, or Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the design area in accordance with sections.5.2.1 or.6.2.1.2 of NFPA 13. Minimum distance between VK7 residential sprinklers: ft. (2. m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT: Always refer to Bulletin Form No. F_0999 - Care and Handling of Sprinklers. Also refer to pages RES1-17 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Figure 1: Sprinkler Installation and Correct Use of Wrenches

Page 6 of 6 Telephone: 269-95-9501 Technical Services: 77-3-56 Fax: 269-1-0 Email: techsvcs@vikingcorp.com Figure 2: Sprinkler Dimensions and Cover Installation Figure 3: Identification of Custom Paint Color for Concealed Covers Figure : Square Cover Assembly 1539 (Added EU Listing)