NookBox Installation Guide Keypad. Installation Guide. NookBox Keypad (P / E )

Similar documents
Installation and Operation Guide EXTERNAL SIREN

Version 1.03 January-2002 USER S MANUAL

Wireless Keypad GKP-S8M

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

Wireless Keypads LKP(E)S8M Series

User s Information Guide R2A

Total Connect Box. User manual

Tomorrow s technology for today s security needs.

AXI LED USER MANUAL (REV. 1.0)

SA 2650 Kit User Manual

Voice Board. Installation and Programming Guide. Runner 4/8,PowerWave 4/8/16 &, Elite64. Add-on Board For Storing Recorded Voice Messages

BENTEL SECURITY srl reserves the right to modify the technical specifications of this product without prior notice.

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

Contents. Glossary

NESS 5000 SERIES DIALLER

Watchguard WGAP864 User Manual

X64 Wireless Training

IDS816 User Manual H Issued January 2009

User's MANUAL A$ Rev 1.4

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

General Purpose IO Technical Manual

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

NO ONE DARES COME CLOSE O WNER S GUIDE 7756V

Ref. 1067/024 Ref. 1067/032A Ref. 1067/052A

Security System. User Guide for the LED Command Center

HILLS Series LED Code Pad User Manual

Proudly Designed and Manufactured in New Zealand. By Arrowhead Alarm Products Ltd

HARDWIRED CONTROL PANELS

Solution Ultima 862 Operators Manual ISSUE 1.10

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

ELT-KLED EliteSuite LED Keypad Installation Manual

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Ultra-8D. ControlPanel. Operators Manual. Advanced DigitalControls CP108-0M-V1

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

9000P Wireless Alarm Owner s Manual

Condominium Security Management System

Ethernet General Purpose

5000 SERIES 8 ZONE INSTRUCTION MANUAL

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

3 User s settings. 3.3 Internal clock setting

Solution 880 Operators Manual. Issue 1.00

GV2 Series Control Panels

Control Panel. Operators Manual TO SUIT AS216 KEYPAD. AS216-OM-6.2. Advanced Digital Controls

Important information. Government Regulations and Safety information. Your Warranty. Replacement remote controls

Protégé Eclipse LED Keypad User Manual PRT-KLES

Solution Ultima Series Operators Manual ISSUE 1.00

l 02-April-2010 For INSTANT CARE

Power Wave LCD Keypads. Users Operating and Programming Guide Version 2.00

Q3200 Smart Home Alarm. Kit Content and Installation Guide

L900 series USER MANUAL

ECo8x Ness ECO8x AlARm CONtROl panel InstallatIon & programming manual Revision 1.5 A$15.00

RUNNER 8/64. 8/64 Zones Control Panel. Program Summary Guide

Easy Fit Touch Screen alarm system (EF-Panel)

Q3000 Smart Home Alarm. Kit Content and Installation Guide

SA 2700 Kit User Manual

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Using Your. Security System With LED Keypad S5030, S5031, S5032

Sync. Smart Home Alarm

Protégé EliteSuite Eclipse LED Keypad Installation Manual ELT-KLES

HSA % wirefree security alarm system. Installation Programming Operating. Helpline Intelligent Security & Fire Ltd

O WNER S GUIDE M O D E L

Solution 844 Operators Manual ISSUE 1.10

JA-63 Profi User manual

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

Security System. User s Guide for the Text Command Center

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Solution 6+6 Wireless - AE Operators Manual ISSUE 1.10

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

Solution 4+4 Operators Manual ISSUE 1.25

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

D1265. User's Guide. Touchscreen Keypad

Ness D8x / D16x ALARM CONTROL PANEL USER'S MANUAL. Revision 5.0 A$15.00

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom


Total Protection Alarm System

RE6100 Series Helix Security and Automation Platform

Digiplex LED Keypads User s Manual

MEGA WAY LCD 4-CHANNEL MOTORCYCLE ALARM SECURITY SYSTEM. Operation Manual MEGATRONIX CALIFORNIA, U.S.A. MEGA 3100 OPERATE 1

AdvisorOne Quick Operation Guide

Advisor Advanced User Guide

USER GUIDE HARDWIRED CONTROL PANELS

Elite S Version 8-16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Control Panel-Based Alarm System Installation Programming Operating Keep this manual safe for reference and future maintenance

Sirène flash. Sirena con lampeggiante DP8406 DP8407 DP8408. Alarmsirene mit Blitzlampe. Siren and flashing. p. 19

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

IDM4 CARAVAN ALARM. Operating instructions

USER GUIDE HARDWIRED CONTROL PANELS

Kwêbeam GSM/Interface/Repeater Module

Security Alarm System Owner's Guide 8 sector CDS Dialler 8-24 sector Control Dialler 8-24 sector Control Securitel Version 1.0 lcopm.

U ser's Guide PC6010

5 Sounds and Indications

HSA6500 GSM alarm. Installation Programming Operating. Keep this manual safe for reference and future maintenance. Contents

M2M Services Ltd. RControl Alarm - Installer Manual V 1.0

LED Keypads D720 Series User s Guide

USER GUIDE HARDWIRED CONTROL PANELS

Power864. User s Guide. Now classified in accordance with ANSI/SIA CP (SIA-FAR)

Vehicle Security System

WIRING DIAGRAM AND INSTRUCTIONS

Transcription:

1 Installation Guide NookBox Keypad (P119010 / E6309744)

2 NookBox Keypad (P119010 / E6309744)

3 Parts Identification 1. Active LED 2. Status LED 3. Fault Display LED 4. Arm Key 5. Home Key 6. Key Check Control Panel Status 7. Disarm Key 8. # Key 9. Key Enter KP Pin Code + Key to enter Test Mode 10. Dual Key Learning Press both # and keys together to send learn Code 11. Medical Alarm (if enabled) press both 7 and 9 to trigger medical alarm 12. Fire Alarm (if enabled) press both 4 and 6 to trigger fire alarm 13. Panic Alarm (if enabled) press both 1 and 3 to trigger panic alarm 14. Battery Insulator 15. Mounting Holes 16. Tamper Swtich A short beep will sound along with key pressing to indicate that the button pressed is valid. 4 continuous beeps will sound indicating mistake and the user should repeat the process again.

4 LED Indicator Active LED (Blue/Amber) Blue LED on 5 seconds: the system is in Normal Operation Mode. Blue LED flashes for 5 seconds: low battery in Normal Operation Mode. Amber LED on: the system is in Test Mode. Amber LED flash: low battery in Test Mode. Active Blue LED will turn on at any key press, after successful completion of a valid keystroke sequence, or when the keypad idles for 5 seconds. When the Active Blue LED turns off before a valid keystroke sequence is completed, the previous entered keys are ignored. Status LED (Blue/Red): Red LED on: the system is in Away Mode. Red LED flash: the system is in Home Mode. Blue LED on: activation of Disarm Mode. Blue LED flash: failure due to the following reasons:» No response sent by the control panel within 4 seconds.» Control Panel User PIN code was incorrect.» Request for Home mode during Arm mode.» Request for Force arm. Fault LED (Amber): Flash: system failure (panel tamper, AC fault, sensor temper, sensor out of order, open door) On: Alarm Memory (depend on Control Panel).

5 Power Remote keypad uses one CR2 3V Lithium battery as its power source. Remote keypad can also detect the battery status. If the battery voltage is low, the Active LED will flash (Amber in Test mode or Blue in Normal mode) during operation. The Low battery signal will be sent along with regular signal transmissions to the Control Panel for displaying the status accordingly. Before shipment, the battery is pre-installed by the factory. When changing battery, press the any key a couple times to discharge before inserting new battery. Power Saving Feature When idle, Remote keypad is in Stand-by mode and uses no power. It will activate and wake-up for 5 seconds when any key is pressed. After 5 seconds of key inactivity, the power goes off and it returns to Stand-by mode. Upon completion of a command input, the power goes off and Remote keypad returns to Stand-by mode. Test Mode Remote keypad can be put into Test mode by entering the Keypad PIN code (default: 0000) followed by will turn on along with a long beep. key. The Active Amber LED To exit Test mode, press key twice, Remote keypad will sound a long beep and the Active LED will turn off, then Remote keypad returns to Normal Operation mode. Otherwise, Remote keypad will automatically exit Test mode after 5 minutes and return to Normal Operation mode. When Remote keypad is in Test mode, it operates as wake-up condition and will NOT disconnect after 5 seconds. Test Mode Function:» Press key and then 7 key Transmit Remote keypad learn signal» Press key and then 2 key Enable Dual-key Panic Alarm function» Press key and then 3 key Enable Dual-key Fire Alarm function» Press key and then 4 key Enable Dual-key Medical Alarm function» Press key and then 5 key Disable all Dual Key function (Default)» Press key and then 6 key Edit Keypad Pin Code Enter Old Keypad Pin Code and then press key Enter New a new 4-digit Keypad Pin Code and then press # key.» Press key twice to leave the Test Mode.» Press key and then 8 key Enable Arm/ Home without PIN Code function» Press key and then 9 key Enable Arm/ Home with Control Panel User PIN Code function (Default) Tamper Protection The keypad is protected against any attempt to open the lid or to detach keypad from its mounting surface. Tamper protection is disabled when the keypad is in Test Mode.

6 Installation Procedures Step 1. Put the Control panel into learning mode. Step 2. Adding remote keypad into the Control Panel: Test Mode Learning: 1. Put remote keypad in Test mode by entering KP PIN code (default: 0000), then press key. The Active Amber LED will turn on along with a long beep sound. 2. Press key then 7 key. Remote keypad will sound a long beep. If the remote keypad did not sound a long beep, it means the remote keypad did not send the learning code to the Control Panel, please press key then 7 key again to send the learning code. 3. If the Control Panel receives the learning code, it will display the info accordingly. Refer to the operation manual of your Control Panel to complete the learn-in process. 4. After Control Panel receives the signal from remote keypad, it will send an acknowledgement back to remote keypad. The remote keypad will then beep 3 times to confirm the acknowledgement has been received. Dual-Key Learning: 1. Press and both # and keys together under Normal Operation Mode. Remote Keypad will sound a long beep. If the remote keypad did not sound a long beep, it means the remote keypad did not send the learning code to the Control Panel, please press both # and keys together again to send the learning code. 2. If the Control Panel receives the learning code, it will display the info accordingly. Refer to the operation manual of your Control Panel to complete the learn-in process. 3. After Control Panel receives the signal from remote keypad, it will send an acknowledgement back to remote keypad. The remote keypad will then beep 3 times to confirm the acknowledgement has been received. <IMPORTANT NOTE> If remote keypad does not perform 3 beeps, please restart the learning procdeure. Step 3. Step 4. Step 5. After the Remote keypad is learnt-in, put the Control Panel into Walk Test mode, hold the Remote keypad in the desired location, and send the learning code to the Control Panel to confirm this location is within the signal range of the Control Panel. To send the learning code, either press the key then 7 key under Test Mode or press both # and keys together under Normal Operation Mode. When you are satisfied that the Remote keypad works in the chosen location, you can proceed with mounting the Remote keypad following the steps described below (see Mounting Remote keypad). Set your own the KP Pin Code: 1. When the keypad is under Test mode, press key then 6 key, a long beep will be sound. 2. Enter 0000 (default PIN code) 3. Press key, remote keypad sounds a long beep. 4. Enter your new 4-digit code. 5. Press # key, remote keypad sounds a long beep. The new PIN code is enabled. Step 6. Press key twice to leave Test mode and the installation is completed.

7 Mounting Remote Keypad To mount the remote keypad: 1. Remove the front cover. 2. Using the 2 mounting holes of the back cover as a template, mark off the positions in the most appropriate place. 3. Insert the wall plugs if fixing into plaster or brick surface. 4. Screw the Remote keypad onto the wall plugs. 5. Replace the front cover. System Mode Control After finish learning the Keypad into alarm system Control Panel, the user may change the system using Keypad. There are two ways to arm the system. 1. Away Arm / Home Arm the system by entering Control Panel User PIN Code. 2. Away Arm / Home Arm the system without entering Control Panel User PIN Code. Disarming the system always requires entering Control Panel User PIN Code. KP-23B-F1 model Keypad supports both 4-digit and 6-digit PIN Code. KP-23B model Keypad only supports 4-digit PIN Code Arm/Home with Control Panel PIN Code Under Test mode, Pressing key and then 9 key to enable Arm/ Home with PIN Code function (Default).» Enter Arm Mode: Enter any one of Control Panel user code and press key. If panel has no fault and arming is successful, the Status Red LED will turn ON alone with a long beep.» Enter Home Mode: Enter any one of Control Panel user cods and key. If panel has no fault and arming is successful, the Status Red LED will flash 4 times alone with 3 beeps.» Return to Disarm Mode: Enter any one of Control Panel user code and key. If disarm is successful, the Status Blue LED will turn ON along with 2 beeps. Arm/Home without Control Panel PIN Code In the Test mode, Pressing key and then 8 key to enable Arm/ Home without PIN Code function» Enter Arm Mode: Press key. If panel has no fault and arming is successful, the Status Red LED will turn ON alone with one long beep.» Enter Home Mode: Press key. If panel has no fault and arming is successful, the Status Red LED will flash 4 times alone with 3 beeps.» Return to Disarm Mode: Enter any one of Control Panel user code and Key. If disarm is successful, the Status Blue LED will turn ON along with 2 beeps.

8 Dual-key Alarm function» Panic Alarm Press both 1 and 3 keys to trigger Panic alarm.» Fire Alarm Press both 4 and 6 keys to trigger Fire alarm.» Medical Alarm Press both 7 and 9 keys to trigger Medical alarm. The dual-key alarm function is disabled by default. To enable it, please refer to the Test Mode section. General Operation» If there is Alarm Memory, the Status Blue LED and fault LED will turn ON with 5 beeps (depending on Control Panel).» Enter Test mode Enter Keypad PIN code and then press key.» Panic Alarm Press 1 key + 3 key at the same time. (if the function is enabled)» Fire Alarm Press 4 key + 6 key at the same time. (if the function is enabled)» Medical Alarm Press 7 key + 9 key at the same time. (if the function is enabled)» Check Control Panel Status Normal Mode Press key. Red LED on: the system is in Away Mode Red LED flash: the system is in Home Mode. Blue LED on: activation of Disarm Mode. Blue flash: failure due to the following reasons: No response sent by the control panel within 4 seconds. PIN code was incorrect. Request for Home mode during Arm mode. Request for Force arm.

9 Fault Conditions When Remote Keypad is under NORMAL OPERATION MODE, a) When fault condition exists within Control Panel, if the Keypad is used to arm the panel, the keypad Status Blue and Fault Amber LED will flash 4 times along with 3 beeps to indicate fault condition. User can force arm the Control Panel by performing the arm action again. b) When the Keypad disarms the panel, the Active Blue LED will turn ON alone with two short beeps indicating normal operation. At a fault situation, it will emit 5 times and turn on both Status Blue and Fault Amber LED for 5 seconds. c) If the Control Panel is under Arm Mode, you CANNOT activate Home mode with Remote keypad. The Status Blue LED will flash 4 times to indicate transmission error. d) If you input incorrect KP Pin code for 4 times, KP will disable the key function for 1 minute and flash all LEDs flashing 3 times with 6 beeps. After 1 minute, it will emit a long beep to indicate that the key function is back to normal. Factory Reset Resetting the Keypad to factory default will restore Keypad s own PIN Code to 0000 and clear all panel learning memory. Reset to factory default: Step 1 Step 2 Step 3 Step 4 Remove the batteries and release the tamper. Press & hold 3 key while inserting the battery back. Continue pressing 3 until three short beeps to indicate successful reset. Release 3 key, the reset process is complete. After reset, PIN code reverts to factory default values, 0000. Remote keypad will need a new learn-in process to start functioning.

10 For more information visit: www.getnookbox.com