Watch the heatsava video

Similar documents
November This product has been reconfigured Please read these instructions

Thank you for choosing EnviroVent

Introducing the RetroVent

Wiring the fan correctly...

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

fact fact fact result No quibble, 7 year warranty. No strings attached. No fans going to landfill sites Happy tenants Money saved

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Filterless Extract Fan. WC, Bathroom + Kitchen

Wiring the fan correctly...

Filterless Infinity Designed to Perform. Built to Last. WC, Bathroom & Kitchen

Cyclone 7 Designed to Perform. Built to Last. WC. Bathroom & Kitchen

230V & SELV INSTALLATION GUIDE FOR ENGINEER / INSTALLER IPX4 IPX5

condensation mould high humidity

Thank you for choosing EnviroVent

HOTLINE:

HOTLINE:

Thank you for choosing EnviroVent

ECo 2 Wall USER GUIDE FOR RESIDENT

energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

Lo-Carbon SELV Tempra

Lo-Carbon Quadra Centrifugal Fan

Centrif Duo & Centrif Duo Plus

KUDOS. Instruction leaflet

Lo-Carbon Quadra SELV

PIV & MIV Loft Mounted Unit INSTALLATION GUIDE FOR ENGINEER / INSTALLER

HEAT RECOVERY VENTILATION For healthy, energy efficient ventilation

energisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system

energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems

ECO dmev Decentralised MEV

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

I tho Advance. Heat recovery ventilation unit. User manual A6_ Ventilator Advance ENGELS.indd /0111/ED

Lo-Carbon Quadra Centrifugal Fan

Ventilation & Heat Recovery. The whole house system from OMNIE

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

Saletto. Operating Instructions. Low Profile Panel Heaters Models: LPP050 LPP075 LPP100 LPP150. A world of expertise

BLOW DRY & GO HAIR KIT

Installation and Maintenance

Glass Chimney Hood. Installation & User Instructions Please keep for future reference

22.2V Turbo Lite Ultra Cordless Handheld Vacuum

LANDLORDS & LETTINGS VENTILATION SOLUTIONS

Fusion HRV2 Mechanical Ventilation with Heat Recovery User / Homeowner Guide

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

GUH90 90 cm Canopy Hood

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

Girona. Operating Instructions. Glass Panel Heaters. Models: GFP050 W/B GFP075 W/B GFP100 W/B GFP150 W/B GFP200 W/B. A world of expertise

Kair Single Room Heat Recovery Ventilator

Stainless Steel Chimney Extractor

Installation & Operating Instructions. Models: Desire, Ignite & Hereford Electric Stoves

MINI DEHUMIDIFIER. SD-350TI With UV Light SD-350 INSTRUCTION MANUAL

Unity CV2GIP / CV2SVGIP Decentralised Mechanical Extract Ventilation (dmev) User / Homeowner Guide

55CM Wide Freestanding Under Counter Freezer Instruction Manual

CLASSIC-100. Instruction leaflet. Instruction leaflet

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

Building Regulations 2010: What it means to you.

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For models WA-1010E, WA-1010H, WA-1010M

Lucci Designer Hi Flow Exhaust Fan

Installation and Maintenance

Installation and Maintenance

STYLE COLLECTION HAIRDRYER

Sentinel Kinetic MVHR RANGE

Stainless Steel and Glass Angled Extractor

Chrome. Approximately 26 seconds drying time. 1.0kW Automatic Eco Fast Dryer Epoxy Coated. 1.2mm thick steel cover

ECOLEC PANEL HEATERS GENERAL NOTES.

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

Warnings, Safety Information and Guidance

Stainless Steel Chimney Extractor

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

Simply Silent Contour 4 (100mm) Axial Extraction Fan

Installation and Maintenance

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

2200W RADIANT HEATER GVARH350. Instruction Manual

Compact Cyclonic Bagless Upright Vacuum Cleaner

USER INSTRUCTION MANUAL. Autofill Water Boiler

Amaze Smooth and Volume

Mira Sport Thermostatic

nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or

INSTRUCTIONS MODEL: MFBU WET WELL BAIN MARIE

GUH52SD 52 cm GUH75 75 cm Canopy Hood

SmartVent. NZ's home ventilation specialists. Become the climate expert in your home. SMARTVENT HOME VENTILATION SYSTEMS

Refresh & Clean Carpet Washer

ECo 2 Wall INSTALLATION GUIDE FOR ENGINEER / INSTALLER

INSTRUCTION MANUAL MNBX14

Koolbreeze. Portable Air-conditioner User s Manual. For Model : CLIMATEASY 14 P14HCP. Downloaded from manuals search engine

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

MULTI Hand Vacuum USER GUIDE 1985 SERIES

aura-t TP536/GBR ventilation systems

User and maintenance manual

20L Dehumidifier. Model Number: LDH V AC 50/60Hz 440W

CI/SfB (57.7) 3rd Edition WINNER2011. Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range.

Vireo Fresh intelligence

Electric Cooker. Important Please read these instructions fully before installing or using

Transcription:

01 heatsava Benefits 02 What is the heatsava? 03 How does the heatsava work? Watch the heatsava video 04 Exploded view 05 Controls 06 Cleaning 07 Servicing 08 Guarantee Scan the QR code to watch the video about how the heatsava works and how it can save you money. Alternatively, watch the video on our website: envirovent.com/heatsava

Improves indoor air quality, reducing condensation and mould problems. Saves energy costs the heat exchange cell recovers up to 75% of the heat that would normally be extracted out to atmosphere. Easy to clean and maintain with the innovative plug out/plug in central cartridge. heatsava thinks for itself with the intelligent humidity tracking controls, meaning that no user intervention is required. Summer mode to stop warm air entering the room on warmer days. Frost protection to prevent the cell from damage during the winter. Part of the EnviroVent Lifetime Range designed with recyclable components. Made in the UK. 5 year renewable warranty.

The heatsava is an energy efficient, through-the-wall mini ventilation unit called a Single Room Heat Recovery unit (SRHR). It has been designed for people who are looking for new and innovative ways to save energy. Recovering up to 75% of heat from the air that would normally be lost through extraction, the heatsava reduces carbon emissions, whilst providing continuous all year round ventilation. It can be mounted through external walls in WCs, kitchens, bathrooms and utility rooms, to either replace existing extractor fans or for new installations.

The heatsava extracts air from the kitchen or bathroom, which passes over a high efficiency tubular heat exchange cell. The unique design of the cell enables the air to cyclone around the barrel, just like a corkscrew. As it does so, the heat from the extracted air is retained in the cell before it reaches atmosphere. At the same time, fresh air from outside is supplied through the tubes, collecting up to 75% of the heat from the extracted air before returning it into the room, providing savings on energy costs. The heatsava runs continuously 24 hours a day on a low background trickle rate to provide constant all year round good indoor air quality, controlling humidity levels and reducing condensation. It is important that you do not switch the heatsava off.

Intelligent Humidity Tracking Controls The heatsava has been engineered with intelligent controls to think for itself, meaning that you don t need to press any buttons or light switches to turn it on. When the heatsava senses a rise in humidity, caused by increased moisture generation such as through cooking or showering, the extract and supply airflows will slowly begin to increase in direct proportion to the increase in humidity. It will then automatically track back down again when humidity falls. This controls condensation quietly and efficiently. Pullcord The heatsava comes complete with a pull cord to activate the boost for odour control if required. Pull once to activate the boost and once to deactivate. Summer Mode During warmer days, the heatsava prevents warm air from entering the room and switches to provide extract ventilation only. As the temperature falls it automatically returns to heat recovery mode. Frost Protection The heatsava has an automatic built-in frost protection mechanism to prevent any damage to the heat exchange cell in cold conditions.

Cleaning Intervals: The cleaning can be carried out by the resident. The heatsava should ideally be cleaned around every 6 months depending on occupancy levels, conditions of use and where the heatsava is located. Fig.1 Vacuum clean the sides of the grille

Servicing must be carried out at regular intervals around every 12 months by a COMPETENT TRADESPERSON. EnviroVent offers a service programme with their own team of nationwide installers. For more information call 0845 27 27 810. The heat exchange cell can be accessed and cleaned as follows: 01 Take off the front cover by removing the screw sited behind the badge. 02 Disconnect the two cable clips and take out the four screws to remove fan adaptor. 03 Insert cell removal key into the heat cell and turn until flush with the face of the cell. 04 Completely remove the heat cell. 05 Wipe clean using a damp cloth and brush. Alternatively use a vacuum.

The heatsava is covered by a 5 year warranty. Do not turn the unit off. It is important that it runs continuously. We appreciate you choosing this quality EnviroVent product, which is designed and manufactured to the highest specification in Harrogate, North Yorkshire. It is important that you register your product. This will ensure the prompt and efficient handling of any communication in the event that your unit requires attention during the 5 year warranty period. You can register your product by calling 0845 27 27 810. Your warranty covers any defect or break down that arises due to faulty materials construction. The system must be correctly installed and operated according to the instructions contained in the user guide supplied. Periodic cleaning and maintenance can be carried out by the resident, however the full 5 year service must be carried out by a competent tradesperson. To ensure a long and trouble-free life, the heatsava must be kept running at all times. The warranty does not cover accidental damage, misuse or abuse. The warranty is in addition to your statutory or legal rights. The warranty will only be honoured from approved suppliers. A further 5 year warranty can be obtained subject to the level of service carried out at the 5 year point.