Liberty Township Fire Department Fire Prevention Bureau. Clean Agent Fire Protection Plan Submittal Checklist

Similar documents
CITY OF MADISON FIRE DEPARTMENT (MFD) FIRE PROTECTION SYSTEM PLANS

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

APPENDIX H (DESIGN SUBMISSION CRITERIA)

Brighton Area Fire Authority

SECTION CLEAN AGENT FIRE SUPPRESSION SYSTEMS

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

Orange Township Fire Department Fire Prevention Bureau

Fire Permit Application

Fort Rouge Leisure Centre Section HVAC Upgrades Phase 2 Page 1 of 5 Bid Opportunity No March 2013 FIRE ALARM SYSTEMS

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE CHEETAH Xi 50 CONTROL PANEL SYSTEM

SECTION : FIRE ALARM & DETECTION SYSTEMS

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPULSE VALVE, FK AGENT & CHEETAH Xi 50 CONTROL PANEL

SECTION TOTAL FLOODING ECARO-25 CLEAN AGENT FIRE EXTINGUISHING SYSTEM

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi 50 CONTROL PANEL

FIRE ALARM APPLICATION CITY OF MADISON HEIGHTS

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM

ONYX FirstVision Specification Interactive Firefighters Display

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

FIRE & LIFE SAFTEY STANDARD

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPULSE VALVE, FK AGENT & CHEETAH Xi CONTROL PANEL

Fire Alarm System Fundamentals

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

Advanced Fire Alarm Systems Training Program Outline (5 Day)

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPUSLE VALVE, Fike FK AGENT & SHP PRO CONTROL PANEL

PLAN REVIEW SUBMITTAL GUIDE

NFPA Changes

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

Florida Building Code 2010

ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

I. INTRODUCTION Codes, Rules, Laws, & Requirements

Fire Sprinkler Plan Submittal Form

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

May 1, Dear Fire Suppression System Contractor/Designer:

26 of 128 9/23/2014 9:25 AM

FIRE SPRINKLER SYSTEMS POLICY

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION

MODULE 8. Tying the Systems Together: Emergency Control Functions and Interfaces

Design & Construction Standards, Revised January

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

FIRE SPRINKLER SYSTEMS POLICY

Sprinkler Permit Applications

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

Architect s Project Number of 12 Fire Alarm/Smoke Detection Systems District Master Specs 2013 Edition

FM-200 In-Cabinet Series

The following information shall become and form part of the contract documents.

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

1. Floor above/floor below notification. 2. Private alarm notification. 3. Not Used 4. Voice alarm notification. 5. Not Used.

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

Idaho Surveying & Rating Bureau, Inc South Cobalt Point Way Tel: (208) Meridian, Idaho FAX: (208)

H BUTCH BROWNING FIRE MARSHAL BUILDING REHABILITATION

El Reno Fire Department Fire Alarm Plan Review Worksheet

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

UNIFIED FACILITIES GUIDE SPECIFICATIONS

September 30, Dear Fire Suppression System Contractor/Designer:

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

CAN/ULC-S1001, INTEGRATED SYSTEMS TEST OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics.

WHITE PLAINS SMOKE CONTROL CODE PART 1. GENERAL REQUIREMENTS

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Engineering Specifications

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

Minimum Standards for Engineers Practicing Fire Protection Engineering in the State of Oklahoma September 14, 2016

Unified Fire Authority - Fire Prevention Bureau

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

Fire Prevention Coffee Break Training. February 2017

HIGH-RISE RETROFIT ORDINANCES - NO and NO

D. Reference Standards (Utilize latest editions available):

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT

Type of Fire Alarm Control Panel: System is: Existing OR New If new, provide Electrical Permit Number:

SPECIFICATION: ARGONITE Engineered Fire Suppression System

SOCIETY OF FIRE PROTECTION ENGINEERS POSITION STATEMENT P THE ENGINEER AND THE TECHNICIAN DESIGNING FIRE PROTECTION SYSTEMS.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement

Full Service Central Station Fire Alarm Listing Evaluation

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

Fire Prevention Coffee Break Training. February 2016

New Construction Fire Inspection Process

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Committee Input No. 9-NFPA [ Global Input ] Supplemental Information. Submitter Information Verification. Committee Statement

Bold items are particular to the City of Euless

AUTOMATIC FIRE SPRINKLER SYSTEMS

SECTION LIGHTING CONTROLS

DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

FIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY

Linear Heat Detection Engineering Specifications

First Revision No. 158-NFPA [ Global Input ] Submitter Information Verification. Committee Statement

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

East Central College

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE

Transcription:

Liberty Township Fire Department Fire Prevention Bureau Clean Agent Fire Protection Plan Submittal Checklist Project Name: Date: Project Address: Designers Name: Company Name: Phone Number: Email: Fax: All supporting documentation showing items listed below is required for review. This checklist is based upon 2008 National Fire Protection Association ( NFPA ) 2001 and the 2011 Ohio Fire Code. The following required items are included in accordance with all applicable provisions of the 2011 Ohio Fire Code ( OFC ), the Liberty Township, Delaware County, Ohio Supplement to the 2011 Ohio Fire Code ( Supplement ), the Ohio Administrative Code ( OAC ), the Ohio Revised Code ( ORC ), and any other applicable source of local, state, or federal law. BOXES MUST BE CHECKED (X) UPON COMPLETION Paper Media: One (1) full set of shop drawings 30 X 42 of standard engineered scale (1:10,1:20, 1:30, 1:40, 1:50, 1:60), shall be of sufficient clarity to indicate the location, nature, and extent of the work proposed and show in detail that it will conform to the provisions of the OFC, Supplement, OAC, ORC, and any other applicable source of local, state, or federal law. Electronic Media: One (1) AutoCAD Base with TIFF Image of each sheet, PDF or JPEG on a Compact Disc in a hard plastic protective case. Per 2008 NFPA 2001, Section 5.1.2.2, provide the name and address of the building owner. Per 2008 NFPA 2001, Section 5.1.2.2, provide the name and address of the project or tenant where system will be installed.

Per 2008 NFPA 2001, Section 5.1.2.2, provide the name, address, and telephone/fax numbers for the designer of the fire suppression /detection system. Per 2008 NFPA 2001, Section 5.1.2.2, the plans shall be drawn to a uniform size and to a recognized scale. Per 2008 NFPA 2001, Section 5.1.2.2, indicate the point of compass and the symbol legend. Per 2008 NFPA 2001, Section 5.1.2.2, indicate the location and the construction of the protected enclosure walls and partitions. Per 2008 NFPA 2001, Section 5.1.2.2, provide an enclosure cross section, full height or schematic diagram, including the location and the construction of building floor/ceiling assemblies above and below the raised access floor and the suspended ceiling. Per 2008 NFPA 2001, Section 5.1.2.2, indicate the type of clean agent being used by its brand name and its chemical nomenclature. Per 2008 NFPA 2001, Section 5.1.2.2, provide the design extinguishing concentration or inert concentration. Per 2008 NFPA 2001, Section 5.1.2.2, provide a description of the occupancies and the hazards being protected designating whether or not the enclosure is normally occupied. Per 2008 NFPA 2001, Section 5.1.2.2, provide a description of the adjacent exposures and occupancies surrounding the enclosure. Per 2008 NFPA 2001, Section 5.1.2.2, provide the description of the agent storage containers used including the internal volume, the recommended storage pressure, and the nominal capacity expressed in units of agent mass, or volume at standard conditions of temperature and pressure. Per 2008 NFPA 2001, Section 5.1.2.2, provide a description of nozzle(s) being used including the size, the orifice port configuration, and the equivalent orifice area. Per 2008 NFPA 2001, Section 5.1.2.2, provide a description of the pipe and fittings used including the material specifications, the grade, and the pressure rating. Per 2008 NFPA 2001, Section 5.1.2.2, provide a description of the wire or cable used including the classification gauge (AWG), shielding, the number of strands in conductor, the conductor material, and the color- coding schedule. The segregation requirements of various system conductors shall be clearly indicated. The required method of making the wire terminations shall be detailed.

Per 2008 NFPA 2001, Section 5.1.2.2, provide a detail or description of the method of the detector mounting. Per 2008 NFPA 2001, Section 5.1.2.2, provide the equipment schedule or list of materials for each piece of equipment or device showing the device name, its manufacturer, its model or part number, the quantity of devices to be installed, and the description and function for each device. Per 2008 NFPA 2001, Section 5.1.2.2, submitted plans shall provide a plan view of the protected area showing the enclosure partitions (full and partial height), the agent distribution system including the agent storage containers, piping, and nozzles; the type of pipe hangers and rigid pipe supports; the detection, alarm, and control system including all devices and a schematic of the wiring interconnection between them; the end-of-line device locations; the location of controlled devices such as dampers and shutters and location of instructional signage. Per 2008 NFPA 2001, Section 5.1.2.2, provide an isometric view of agent distribution system showing the length and the diameter of each pipe segment; the node reference numbers relating to the flow calculations; the fittings including reducers and strainers; the orientation of tees and nozzles including the size, the orifice port configuration, the flow rate and the equivalent orifice area. Per 2008 NFPA 2001, Section 5.1.2.2, scaled drawings shall be provided showing the layout of the indicator panel graphics. Per 2008 NFPA 2001, Section 5.1.2.2, provide details of each unique rigid pipe support configuration showing the method for securing the pipe to the building structure. Per 2008 NFPA 2001, Section 5.1.2.2, provide details of the method for the container securing showing the method of securing to the container and to the building structure. Per 2008 NFPA 2001, Section 5.1.2.2, provide a complete step-by-step description of the system sequence of operations, including the function of abort and the maintenance switches, the delay timers, and the emergency power shutdown. Per 2008 NFPA 2001, Section 5.1.2.2 and 2010 NFPA 72, Sections 21.2.4, 21.2.5, and 21.2.6, the submitted plans shall include a point-to-point wiring schematic diagram(s) in a plan view and a system riser diagram showing all the circuit connections to the system control panel and the graphic enunciator panel. This is to include any external or add-on relays. Per 2008 NFPA 2001, Section 5.1.2.2, provide a complete set of calculations to verify the enclosure volume and to determine the quantity of clean agent required Per 2008 NFPA 2001, Section 5.1.2.2, provide a complete set of back-up battery calculations and voltage drop calculations for the detection system.

Per 2008 NFPA 2001, Section 5.1.2.2, indicate the method used to determine the number and location of audible and visual indicating devices and the number and location of the detectors. Per 2008 NFPA 2001, Section 5.1.2.2 and 2010 NFPA 72 Sections 21.2.4, 21.2.5, and 21.2.6, provide details and wiring diagrams for any special features, i.e.: interconnection of release panel with building fire alarm system, interface of the system with the HVAC controls, interface of the system with the security/special locking devices. Per 2008 NFPA 2001, Section 5.1.2.5.1, the submitted plans shall include the flow calculations for the system. The version of the flow calculation program shall be identified on the computer calculation printout. Per 2008 NFPA 2001, Section 5.1.3.2, where field conditions necessitate any material change from approved plans, the change shall be submitted for approval prior to installation. Per 2008 NFPA 2001, Section 5.2.1, the system flow calculations shall be performed using a calculation method listed or approved for the agent by the authority having jurisdiction. The system design shall be within the manufacturer s listed limitations. Per 2008 NFPA 2001, Section 5.2.2, all valves and fittings shall be rated for equivalent length in terms of pipe or tubing sizes with which they will be used. The equivalent length of the container valves shall be listed and shall include the siphon tube, the valve, the discharge head, and the flexible connector. Per 2008 NFPA 2001, Section 5.3.5, the submitted plans shall show the wiring details for shut down of non-self-contained HVAC forced-air ventilation systems. Per 2008 NFPA 2001, Section 5.3.5, the submitted plans shall show the wiring details for the automatic closure of fire or fire/smoke dampers in the HVAC forced-air duct units that supply the protected enclosure. All submissions shall include the appropriate Manufacturer s Data Sheets with the following information: Agent Cylinder and Valve Assemblies Agent Cylinder Data Agent Valve Outlet Adapters Agent Discharge Nozzles Agent Release Control Heads Agent System Release Control Panels Suppression System Abort Devices Agent Manual Release Stations Initiating Devices

Notification Appliances Conductor Wire, Relays, Interface Modules Other Where multiple contractors are involved in the system design/installation, plan approval requires concurrent submittals and review of the fire suppression and detection systems. Refer to the Fire Alarm Checklist for additional information and requirements regarding the associated detection system.