Page: 1 of 11 Collection of compact exterior luminaires for architectural lighting. Rugged stainless steel construction, with tempered glass lens, these luminaires are designed to perform in extreme conditions. This Serie is available in 3 sizes, that can be installed for in-ground, wall or ceiling applications. Complete range of optic distributions for accent lighting, effects lighting and markers. Luminaire characteristics: Source: Lumen maintenance: Power input: Up to 6W Lumens: Up to 47lm (for 00K, ) Luminaire efficacy: Up to 8lm/W LUXEON LED MODULE (LM-80 tested) 2700K :, 00K :, 4000K :. 80% of initial lumens at 0 000 hours (L80) (LM79 tested) Optics:, Flood, Wide Flood, with Optibeam technology, or Wall Washer, and Light Blade Material: Body and frame: Stainless steel r: 6 to 8 mm thick. tempered glass lens Optics: PMMA lens or PE film for optic, clear, black or metalized Polycarbonate reflector Mounting: Ground, wall or ceiling recessed installation using polypropylene back box (To be ordered separately). Supplied with (2m) long outdoor rated power cable. Connections to be made inside back box using wiring accessories. 12" of gravel is required below the luminaire to allow proper drainage. Electrical: See remote power supply options on page 9-11 Finish: Stainless steel Weight: I.LUO28: 0.4lbs (0.2kg) I.LUO0: 1.2lbs (0.kg) I.LUO80: 2.8lbs (1.3kg) Load capacity: 4409lbs (2000kg) Surface temperature: 4 F (40 C) Operating temperature: -22 to 122 F (- to C) Warranty: year limited warranty Ratings: IP68, IK09 Certification: Wet location
Page: 2 of 11 FAMILY OVERVIEW 1" (28mm) 1W 1⅛" (28mm) () Flood (2 ) (6 ) Flood (23 ) Wide Flood (41 ) Light Blade Wall Washer (9 ) Flood (36 ) Wide Flood ( ) Light Blade Wall Washer 2" (0mm) 1-4W 2" (0mm) 3" (80mm) 3 -.W 3⅛" (80mm)
Page: 3 of 11 DIMENSIONS 1" (28mm) 2" (0mm) 2" (0mm) 1⅛" (28mm) TOP VIEW TOP VIEW 2⅝" (68mm) 2⅞" (72mm) 4" (3mm) 12" of gravel is required below the luminaire to allow proper drainage 12" of gravel is required below the luminaire to allow proper drainage ½" (140mm) 6⅝" (170mm) SECTION VIEW SECTION VIEW 4" (3mm) 3" (80mm) 3⅛" (80mm) TOP VIEW 3⅛" (79mm) 4" (3mm) 12" of gravel is required below the luminaire to allow proper drainage 7½" (190mm) SECTION VIEW
Page: 4 of 11 PHOTOMETRIC DATA Visit www.iguzzini.com/us for complete photometric data. 1" (28mm) CCT CRI (K) 00K GROUND WALL 80 1 LOAD LOAD (W) (W) 1W 0.4 22.9 0.7.2 1.1.71 1.4 247 3.66 1.8 8 2.4 2.1 370 1 (lm / w) (cd) 36 Flood 16 2 1 1.0 17.0 1. 0.03 22.7 2.0 0.02 28.4 2. MAX CANDELA 41.4 0.9.4 1.7 4.6 2.6 2.9 3. 113 1.66 4.4 142 1.1.2 170 28 7 8 1W - 00K - 80 CRI - Flood 2 11.3 0.06 18 0.14 34.0 (lm) 123.7 0.02 EFFICACY 62 0.4 1W - 00K - 80 CRI - 1 LUMENS 91.4 1W - 00K - 80 CRI - CEILING OPTIC 0. 3.0 *USE MULTIPLIER TABLE FOR OTHER CCT AND CRI OUTPUT DATA CCT options 2700K 00K 4000K CRI options Multiplier 0.94 1 1.12
Page: of 11 PHOTOMETRIC DATA Visit www.iguzzini.com/us for complete photometric data. 2" (0mm) CCT CRI OUTPUT (K) (W) 00K WALL CEILING 1 1 1 (cd) 288 MO 1.W 9 63 393 HO 2W 4W 12 62 11 Flood 31 78 1 Wide Flood 31 78 6 4 1W Wall Washer 3 3 1W 4 MO 1.W 1 HO 2W 20 1W Light Blade 0 320 0.4 1733 142 0.6 2600 80.0 0.8 3467 1.2 1.0 4333 3. 1.2 200 867 41.1 3.0 220 18.3 4. 3.3 6.0 440 6.8 7. 0 4.7 9.0 660 1 1.9 3 0.22 16.3 0.12 21.8 7 0.08 27.2 8 0.0 32.7 1.6 33 42.1 2. 800 23.7 3.3 67 1.1 4.1 1333. 4.9 1600 2 1 1.2 3.0 1.98 2.4 6.0 17 0.88 3. 9.0 2 0.49 4.7 12.0 33 0.32.9 1.0 42 0.22 7.1 17.9 0 7.9 94.6 267 8 1W - 00K - 80 CRI - Wall Washer 0.49 0.8 379 4W - 00K - 80 CRI - Flood 23.4 1 1.9 2W - 00K - 80 CRI - 7 1. 164 4W - 00K - 80 CRI - Wide Flood 41 MAX CANDELA 70 0.2 (lm / w) 70 2W - 00K - 80 CRI - 6 (lm) 1280 EFFICACY 1W 80 LUMENS GROUND OPTIC LOAD 19.9 1.8 0.2 4.96 3.6 0.3 37 2.21.4 0. 1.24 7.2 0.6 73 0.79 9.0 0.8 92 0..8 1.0 1 18 1W - 00K - 80 CRI - Light Blade *USE MULTIPLIER TABLE FOR OTHER CCT AND CRI OUTPUT DATA CCT options 2700K 00K 4000K CRI options Multiplier 0.94 1 1.12
Page: 6 of 11 PHOTOMETRIC DATA Visit www.iguzzini.com/us for complete photometric data. 3" (80mm) CCT CRI OUTPUT (K) OPTIC LOAD GROUND 4W 80 00K 4.W WALL MO.W 1 0.3 663 0.6 3 667 29 0.9 00 166 1.2 7 333 6 1. 9 167 73.6 1 1.8 11 000 1 (cd) Wall Washer 120 40 14 Light Blade 2 8 71 40.3 4.1 217 17.9 6.2 32.1 8.3 433 6.4.4 42 4.4 12.4 60 87 7 860 29 73 770 Wide Flood 34 86 480 40 1 Wall Washer 160 3 19 Light Blade 6 96 47 86 600 Flood 39 71 1 0 Wide Flood 460 83 640 20 11.4 8 0. 17.0 13 0.3 22.7 17 0.2 28.4 21 0.1 34.1 2 1 2. 367 27.8 3.8 0 1.7.1 733.0 6.4 917 183 7.6 10 1 1.1 3.3 6.2 2.2 6.7 67 2.8 3.3.0 0 1. 4.4 13.4 133 1.0. 16.7 167 0.7 6.6 20.0 200 2.0 33 4.W - 00K - 80 CRI - Wall Washer 4 62.6 1.3.W - 00K - 80 CRI - Flood 36 21 6.9 1 1.2.7 8.0.W - 00K - 80 CRI - 1 30 2.1 MAX CANDELA Flood 161 (lm / w) 1 833.W - 00K - 80 CRI - Wide Flood (lm) 2 61.W - 00K - 80 CRI - 9 EFFICACY (W) 3W LUMENS 236 1.7 0.1 8.9 3.3 0.2 323 26.2.0 0.3 48 14.7 6.7 0.3 647 9.4 8.3 0.4 808 6..0 1. 970 162 4W - 00K - 80 CRI - Blade 2 x4 *USE MULTIPLIER TABLE FOR OTHER CCT AND CRI OUTPUT DATA CCT options 2700K 00K 4000K CRI options Multiplier 0.94 1 1.12
Page: 7 of 11 WALL WASHER INSTALLATION SUGGESTED SURFACE DISTANCE 2" (0mm) 13' (4m) 3" (80mm) ' (3m) FLOOR WASHER FLOOR WASHER WALL WASHER 12" (0.3m) 19" (0.m) WALL WASHER 16" (0.4m) 19" (0.m) SUGGESTED SPACING FOR UNIFORM DISTRIBUTION 2" (0mm) 19"~31" (0.m~0.8m) 19"~31" (0.m~0.8m) 3" (80mm) 19"~3" (0.m~0.9m) 19"~3" (0.m~0.9m)
Page: 8 of 11 ORDERING INFO - ILUO - RESET - REM - 13 FIXTURE MODELS I.LUO0-2" (0mm) I.LUO80* - 3" (80mm) - Base output MO - Medium output HO - High output 827-2700K, 80 CRI 8-00K, 80 CRI 840-4000K, 80 CRI - For 28mm (2 ) FL - Flood - For 0mm (23 ) WF - Wide Flood I.LUO28-1" (28mm) OUTPUT LED OPTICS - For 28mm () SP - - For 0mm (6 ) - For 80mm (9 ) WW - Wall Washer - For 80mm (36 ) DI - - For 0mm (41 ) - For 80mm ( ) BL - Light Blade VOLTAGE REM - Remote FINISH 13 - Stainless steel *Not suitable for ceiling installation MOUNTING ACCESSORIES (TO BE ORDERED SEPARATELY) I.X190 - Polypropylene recessed Back box for in-ground installation for I.LUO28 ؽ" x 4" (Ø140mm x 1mm) I.X191 - Polypropylene recessed Back box for wall and ceiling installation for I.LUO28 ؽ" x 4" (Ø140mm x 1mm) WIRING ACCESSORIES (TO BE ORDERED SEPARATELY) I.X188-02 - Black 2-way cable joiner, rated IP68 / IK ø23mm I.981-02 - Black watertight connectors (x4), rated IP68 I.X193 - Polypropylene recessed Back box for in-ground, wall and ceiling installation for I.LUO0 Ø6¾" x 4" (Ø170mm x 1mm) I.X19 - Polypropylene recessed Back box for in-ground and wall installation for I.LUO80 Ø7½" x 4" (Ø190mm x 1mm)
Page: 9 of 11 REMOTE POWER SUPPLY OPTIONS I.LUO28-1" (28mm) (TO BE ORDERED SEPARATELY) Watts Voltage Rated - 1W* Dimming protocol Dimming range Max distance** Dimension Min-Max Units 4444-030-006-UNV-ND 6 None None 1-6 ft(9m) ft(9m) " x 4" x 3" (127 x 2 x 76mm) 3ft(m) ft(9m) 11(36m) 11(36m) 4444-030-012-120-LTE 12 3-9 4443-030-013-UNV-D2 13 Lutron Hi Lume A-Series (3 wires or EcoSystem ) ±% 4444-030-017-UNV-D 17 7-14 440-030-019-UNV-ED 19 ±1% 6-11 440-030-0-UNV-SD * Wattage requirement for one (1) fixture (Remote fixture only). ** Calculated for a 16AWG cable, contact factory for longer remote distance. WIRING DIAGRAMS *Multiple luminaires must be connected in series (home run or fixture chain)
Page: of 11 REMOTE POWER SUPPLY OPTIONS (TO BE ORDERED SEPARATELY) Watts Voltage Rated - 1W* Dimming protocol Dimming range Dimension Max distance** ft(9m) ft(9m) 11(36m) 11(36m) I.LUO0-2" (0mm) - 4W* MO - 1.W* HO - 2W* Min-Max Units 4444-030-012-120-LTE 12 3-9 1-2 7-14 2-4 4444-030-017-UNV-D 17 440-030-019-UNV-ED 19 ±1% 440-030-0-UNV-SD 448-000-020-UNV-D 20 Outdoor -12 7" x 4" x 3" (178 x 2 x 76mm) ft(9m) 7" x 4" x 3" (178 x 2 x 76mm) ft(9m) 11(36m) 448-000-02-120-LTE 2 Outdoor 7-1 440-000-0-UNV-ED ±1% 440-000-0-UNV-SD 11(36m) " x 8" x 4" (24 x 203 x 2mm) ft(9m) " x 8" x 4" (24 x 203 x 2mm) ft(9m) 11(36m) 4444-0700-032-120-LTE 32 8-14 4444-0700-02-UNV-D 2-11 440-0700-0-UNV-ED 440-0700-0-UNV-SD 11(36m) * Wattage requirement for one (1) fixture (Remote fixture only). ** Calculated for a 16AWG cable, contact factory for longer remote distance.
Page: 11 of 11 REMOTE POWER SUPPLY OPTIONS (TO BE ORDERED SEPARATELY) Watts Voltage Rated - 3W* Dimming protocol Dimming range Max distance** Dimension I.LUO80-3" (80mm) - 4W* MO - 4.W* MO -.W* Min-Max Units 4444-030-012-120-LTE 12 3-9 1-2 3-4 2-4 1-6 1- ft(9m) 4444-030-017-UNV-D 17 ft(9m) 440-030-019-UNV-ED 19 ±1% 11(36m) 11(36m) 7" x 4" x 3" (178 x 2 x 76mm) ft(9m) 440-030-0-UNV-SD 448-000-020-UNV-D 20 Outdoor 4 3 3-2-4 1-1- 448-000-02-120-LTE 2 Outdoor 7" x 4" x 3" (178 x 2 x 76mm) ft(9m) 11(36m) 11(36m) 440-000-0-UNV-ED ±1% 440-000-0-UNV-SD * Wattage requirement for one (1) fixture (Remote fixture only). ** Calculated for a 16AWG cable, contact factory for longer remote distance. WIRING DIAGRAMS *Multiple luminaires must be connected in series (home run or fixture chain)