PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

Similar documents
PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

INTEGRATED LIGHTING CONTROLS

DHL-LP-LED Low Profile LED Linear High/Low Bay

VESICA LINEAR SUSPENDED VES L

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Installation Instructions

Sensors and Detectors

LS-CM Series. Overview. Applications. Features & Benefits. Datasheet. Ceiling mount occupancy sensors

Tri-level Control Sensor

Passive infrared ceiling sensor

Ceiling PIR HS presence detector. Product Guide. Overview. Features

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

Mini Product Guide.

Maestro 0 10 V Dimmer Sensor

DHM5150 Human Motion Sensor Module User Manual

DS160/161 Request To Exit PIR sensors Installation Instructions

HIGH POWER LED RETROFIT MODULE

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

Versatile wall switch sensors maximize payback and simplify code compliance

Wireless Occupancy Sensor, Wall Mount with Photosensor (WOS2-WM)

Technical Application Guide

Applied Lighting Controls

Wireless High Bay Sensor (WHS100) Installation Instructions

Wireless Occupancy Sensor, Ceiling Mount (WOS2-CM)

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

F series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC

, ,

600 Watt Dimmer Install Guide

Installation Instructions

Welcome. Sensor. 1 (844) LIGHTCLOUD Custom manufactured in China RAB Lighting, Inc 170 Ludlow Avenue Northvale, NJ 07647

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2

Lighting Control Solutions for Parking Facilities

Installation Instructions

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

IP65 High Bay Dual Sense Sensor

ADDENDUM NO. 2 COOK LIBRARY BATHROOM RENOVATIONS PROJECT NUMBER TU-1874-SBR

Specifications Occupancy/Vacancy Sensors CSI ASHRAE AIA Division 16 Section 16950

Sensors Explained AUTOMATION

CS1200 WHT Pir Ceiling Mount Occupancy Sensor

LUX Hardwired - Installation Notes

IP65 High Bay Dual Sense Sensor

LIVMODERN LIVMODERN RPT. Elegant linear LED fixture PART NUMBER BUILDER 10VDIM 0-10VDIMMABLE 3000K 4000K 24IN 36IN 48IN 1800LM* 3000LM** 3500LM***

CONTENTS SENSOR SWITCH

PRODUCT LYNC IoT 37. PRODUCT: LYNC IoT

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

Product Specifications Dialog Room Controller* (*patent pending)

B.E.G. LUXOMAT. Find the right detector.

Installation Instructions

Intrusion Outdoor Protection Perimeter

SECTION 26 NX DISTRIBUTED INTELLIGENCE LIGHTING CONTROL SYSTEM HUBBELL CONTROL SOLUTIONS

2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F E. cristalcontrols.

Alliance 4 - ALI4 LED 4 Linear High Bay

Tebis application software

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Built-in HF Sensor for High Bay

Douglas Lighting Controls. Bluetooth Fixture Controller & Sensor. Installation Manual BT-FMS-A. *Patent Pending. Installation Guide BT-FMS-A v7

Never forget to turn the lights off again. Motion Sensors

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

Duct and Rough Service Carbon Monoxide Sensor

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide VT8600 Series Room Controllers

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Description. Optex Incorporated

Tri-level Control HF Sensor

A Simpler and Smarter Wireless Lighting Control Solution. Design & Application Guide

Low-Voltage Occupancy Sensors

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide. SE8600 Series Room Controllers

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

DS160/DS161 Request To Exit PIR sensors Installation Instructions

EBDSPIR-PRM-LV Product Guide

TER Active Room Temperature Sensor (Controller),

Wherever the best is needed. Sensors for professionals.

FR-A180 FR-A360. Occupancy detector. Use

ENERGY EFFICIENCY EXPERTS

English. Italiano. Português. Françias. Español

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR

Install Guide MXS-BRO SERIES SMALL BRO LED MULTIPLE RECESSED

BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR

design line performance line Guardall DesignLine & PerformanceLine detector series 2015 Peace of mind

Pioneering Petroleum Canopy Lighting Since 1976

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

Ammonia Leak Detector Manual

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

BAYMAX TM LED LINEAR HIGHBAY FIXTURE BLHT SERIES

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

BALLAST SOURCE EB- Electronic ballast BALLAST QUANTITY. 1-(1) 4-light ballast LAMP SPECIFICATIONS SPECIFICATIONS

CALIBER LIGHTING. SERIES 4VDWWL Shower Lens LED Dim-to-Warm Recessed Downlight, 1018 Lumen APPLICATION PRODUCT DATA. 4VLEDWL Example: 4VLEDWLSCLPF

FCSENS0R Occupancy Sensor. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

VIENTO MEDIUM AREA & SITE LED LUMINAIRE OPTICS

Transcription:

TECHNICAL SPECIFICATIONS PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor Overview Quad Element PIR sensor 0-10V configurable output: set to 0% (OFF)*, 10%, 25% or 50% dimming Photocell for ambient light detection Time delay 1 adjustable 5 sec to 30 min Time delay 2 adjustable 10 sec to LED Motion indicator Active High/Low outputs for Relay drive Mounting height up to 40ft. 360 coverage pattern Bluetooth add-on enables remote sensor programming (up to 40ft) with greater customization of dimming levels, time delays, and ambient light sensitivity Suitable for indoor and outdoor use E341446 Applications The PSC-BL-I-FM-DC0 uses digital PIR Motion Detector Architecture and Quad Element passive infrared (PIR) technology for improved detection coverage for ceiling mount, high bay, and low bay applications. The PSC-BL-I-FM-DC0 is a Class 2 Device designed to satisfy new CA Title 24 requirements for bi-level dimming of lighting fixtures. Using a 0-10V signal, the sensor is capable of dimming lighting loads down to 0% *, 10%, 25%, or 50%. The sensor is suitable for a variety of indoor and outdoor applications. It supports fixture and ceiling mounts up to 40ft high. Both sensor and power pack are rated for use in temperatures ranging from -30 to 70 C and relative humidity from 90 to 95% at 30 C. 0-10V: 100mA to drive up to 50 LED sink drivers on 0-10V output. High Vin-2.5V 100mA source Low 100mA sink current *For dim to off, Pacific PSC-AC-PP-200 Power Pack or LED dimming driver capable of dimming to off is required. How to Order Sensor Operation End users can program length of time delays, light level and motion detection sensitivity, and other settings using a series of dipswitches and trimpots. Simply remove the lens to gain access. Bi-level Dimming**: 0-10V bi-level dimmer connects to 0-10V control on the LED driver. When motion is detected the sensor will bring lighting up to 100% lumen output. When no motion is detected for the length of TD1, the sensor will send a signal to dim lighting to a specific level set by the end-user. If no motion is detected for the length of TD2, the sensor will send a signal to shut off the light. Relay Control: Two additional High and Low control outputs can be used to trigger relays or other control circuitry. Bluetooth smart and Bluetooth mesh: The Bluetooth Low Energy (BLE) enabled version pairs with an Android or ios application to allow initial setup and subsequent sensor adjustments, beyond what the analog controls on the sensor can offer. The mobile application enables adjustment of sensor parameters such as time delay, dim level, sensitivity, ambient light level, and more. Additionally, features such as parameter profiles, manual dim control, and real-time feedback from the sensor can speed up configuration and provide custom user control. The Bluetooth Smart enabled sensors support mesh networking through a variety of software and wireless platforms. Accessories Power Pack: The PSC-BL-I-FM-DC0 operates on 12-24VDC input and requires a separate power pack such as the PacWave PSC-AC- PP-200/300/400. This power pack incorporates a high current relay and a high voltage transformer which can accept universal input (100-305VAC). Alternatively, the sensor can also operate with a driver that has an auxiliary output (12V). Fresnel Lens: LBL: 8-30ft Fresnel Low bay lens HBL: 20-40ft Fresnel High bay lens **The sensor will dim the light if motion is not detected for the first time delay (TD1) and shut off the light if motion is not detected for the second time delay (TD2). TD2 will only count down after TD1 has expired and the light has dimmed. If motion is detected during TD2, the light will return to full output, and TD1 will restart. If using a power pack, the sensor will tell the power pack to shut off the driver after TD2 expires to turn off the light. If using a dimming driver without a power pack, the sensor will try to dim down to 0% upon expiration of TD2. Since one trimpot configures both TD1 and TD2, a fixed TD2 is set to each value of TD1. See page 2 for the corresponding values. Model No. Description Input Voltage Output PSC-BL-I-FM-DC0 (-BLE) Bi-Level Passive Infrared (PIR) Occupancy Sensor (add -BLE suffix for Bluetooth Enabled version) 12-24VDC 0-10VDC Control High Control Low PSC-AC-PP-200 Dimming Power Pack for Mount 100-277VAC 12.5VDC PSC-AC-PP-300 Dimming Power Pack for Mount no Relay 100-277VAC 12.5VDC PSC-AC-PP-400 Power Pack for Mount no Relay 100-277VAC 12.5VDC Add Suffix for options: /C with Connector, see page 3, Lead Option B -M with enclosure for Bottom-mount or Side-mount Rev. 7/19/2018

Ø 2.40 in 1.41 in 1.37 in Summary Sensor Type PIR occupancy sensor Input Voltage Current Consumption 12-24VDC 25mA sensor (50mA w/ BLE) 0-10V Output 100mA, up to 50LED sink drivers High Low Max Sensor Range Best Performance Time Delays (TD1/TD2) Photocell Sensitivity Vin-2.5V 100mA source 100mA sink current 40 ft / 980 ft² 12 ft / 113 ft² 5 sec/10 sec, 5 min/30 min, 15 min/45 min, 30 min/60 min, 10 min/ 3 Lux to daylight Operating Temperature -30 C to 70 C Storage Temperature -40 C to 80 C Relative Humidity 90-95% non-condensing at 30 C Mounting Color Warranty or ceiling mount (max 40ft high) White 5 years PSC-BL-I-FM-DC0(-BLE) Settings Adjustment Dipswitch 1 Dipswitch 2 DIM Level OFF OFF OFF OFF ON 10% ON OFF 25% ON ON 50% Trimpot #1: Time Delay Trimpots Trimpot #2: Ambient Light Trimpot #3: Motion Detection Note: The absolute range of the sensor is subject to variation because of different types of clothing, backgrounds, and ambient temperature. Therefore, ensure that the lens is properly oriented along routes with expected traffic and conduct testing along those routes. Trimpot #1 on left adjusts time delay. Trimpot #2 in middle adjusts ambient light sensitivity. Trimpot #3 on right adjusts motion detection sensitivity. Turn clockwise to increase and counterclockwise to decrease. Dipswitches: Dimming Level Standard Housing Physical Dimensions Side Mount Housing Bottom Mount Housing 1.86 in 1.12 in.73 in Ø 1.1 in 0.3 in Weight: 2.20 oz (with cord) 2.1 in 1.7 in Lens Cover 2.6 in 1.6 in 1.7 in 1.6 in 0.83 in 2

PSC-BL-I-FM-DC0(-BLE) Detection Area 12ft Mounting Height Low Bay Lens 30ft Mounting Height Low Bay Lens High Bay Lens 3

PSC-BL-I-FM-DC0(-BLE) PSC-BL-I-FM-DC0 Sensor Module Installing the PSC-BL-I-FM-DC0 in the light fixture Inside Tightening Nuts Outside Inside Tightening Nuts Outside Lens Assembly 4

PSC-BL-I-FM-DC0(-BLE) Wiring Diagrams (1) Dimming Driver w/ Power Pack (2) Non-Dimming Driver w/ Power Pack Hot Hot Load COM Load COM Dimming Driver Non- Dimming Driver Dim+ Dim - 5

Lead Options: PSC-BL-I-FM-DC0(-BLE) Option A (Standard): Option B (/C): 1 Matching male and female connector: TE 794617, 794616 or equivalent Sensor Block Diagram: Vin-2.5V 100mA source YLW Control High Control Low 100mA sink current WHT 0-10V Driver Dimming Wires BRN DIM GND Sensor GND BLK 12-24V Power Source PRP 0-10V +V RED Note: If using a power pack other than PSC-AC-PP-200/300/400 as power source, connect either Control High or Control Low, depending on power pack relay circuitry. 6