Emotron M10 Shaft Power Monitor. Instruction manual English

Similar documents
Emotron DCM Control Unit

User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens.

Model SWH-3000 Proximity Multi-Frequency 125KHz & 13.56MHz (Fixed) Reader Installation Guide. Version A0 Part Number UM-102 September 2005

INSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER

Model SWH-4000 Multi-Technology Mullion 125 KHz and MHz (Flex) Reader Installation Guide. Version A0 Part Number UM-104 September 2005

RC300 IntelliFire Plus Multifunction Remote Control Installation & Operating Instructions

Instructions for the fan motor control system with integrated wiring terminals SILVER C

CR Series Command Relays

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description

TEC2100 Series Networked Thermostats

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

RE-PR3-E-27 3-Phase Panel Mount 27kW

SEE DISCLAIMER ON REVERSE

Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

RSGD. Three phase AC motor soft starter. Benefits. Description

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

3M Benchtop Air Ionizer 963E. User s Guide

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

MR3CCUHV Temperature/Defrost Control

CentreVu Call Management System. Release 3 Version 8 Alarm Origination Manager

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

TEC210x-2 Series Networked Thermostats

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

APC BC300 Series 40kW 208/450/480V User Guide

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

Instructions for the fan motor control system, SILVER C

Door Release Power Supply

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Soft Starter Centrifugal Pump Soft Starter Series

Instruction Manual. CMP-12/24 Fire Alarm Control Panel. 12 Clintonville Road, Northford, CT DOCUMENT /11/96 REV: D1

Ordering Key. Dielectric strength

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide

TLM-1 TOWER LIGHT MONITOR V3.0. INSTALLATION and OPERATING INSTRUCTIONS

Unipower HPL420. User s Manual. True Motor Power Monitor with... Typical Applications. High Trip Alarm. Low Trip Alarm.

ISIS SAFETY SYSTEM Installation guide

FCPS-24F FIRE ALARM FIELD CHARGER/POWER SUPPLY FOR FIRE PROTECTION/SIGNALING SERVICE FCPS-24F/FCPS-24FE. Field Charger/Power Supply

Operating Manual MS220KA and MSR220KA

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Using your LED Plus keypad

FCPS-24F/FCPS-24FE. Field Charger/Power Supply D P/N 50079:D ECN Installation, Operation and Application Manual

INSTRUCTION MANUAL T30 1MN0107 REV. 0. operates with ISO9001 certified quality system

Fume Hood Operating Display Panel

LC3000 Level Controller Installation and Maintenance Instructions

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

LC2200 Level Controller Installation and Maintenance Instructions

Instructions for the BASIC BCRW Fan, Sizes General

METEOROLOGICAL INSTRUMENTS

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

PHOTOVOLTAIC HEAT CONTROLER PVHC 2.01 USER MANUAL

Installation Guide for models:

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

INSTRUCTION MANUAL T-154. DOSSENA s.n.c. Via Federico Barbarossa s/n Cavenago di Adda tel Fax:

safety & regulatory information

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

Installation Instructions

ShockLink. Important Product Information.

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Instruction Manual August sitrans CU 02

Installation Guide for models:

TEC1100 Series Thermostats

FSW300 Series Flow Switch

DTA. Motor thermistor relay. Benefits. Description

Panic. Part Number SYSTEMS, Inc.

Installation and application. Leakage detectors, CLS/FLS/FLS10/MiniCAS II

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Analog Room Pressure Monitor RPC Series

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver

ADC-T2000. Smart Thermostat v1.5

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

DTA04. Motor thermistor relay. Benefits. Description

C Note! LGI16... Burner Controls. Building Technologies

WARNING FIRE DOOR CLOSING

1. Instruction. 1.5 Warranty Comar Condensatori S.p.A. guarantees its own products for twelve months from purchase

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

Table of Contents. T538 Instruction Manual Rev # 6 June R6T538 June rtf E L Switchgear and Control Inc

SACE PR021/K SIGNALLING UNIT

Smart Hub THERMOSTAT. Installation Manual

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

ESP TECHNOLOGIES LIMITED

4 & 8-POINT ANNUNCIATORS Instruction Manual

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

EVO192 v3.0 Fire and Burglary What s New

Laboratory Airflow Monitors & Controls TYPE C STANDARD & NIGHT SETBACK LED & DIGITAL - VAV SYSTEMS


INTRODUCTION / TABLE OF CONTENTS

INSTRUCTION MANUAL. Stirring hotplate (with probe and stand) Brand : (Dragon laboratory)

EUROFLAT SERIES TYPES C... S... M...

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Transcription:

Emotron M10 Shaft Power Monitor Instruction manual English

Contents 1 Inside the box... 3 2 Safety... 4 3 Description... 5 4 Getting Started... 6 4.1 Please take note of the safety section... 6 4.2 Connection and set-up before first start... 6 5 Wiring... 8 5.1 Latched or un-latched alarm... 10 6 Selecting the current transformer... 11 6.1 For motors up to 50 A... 11 7 Operation... 13 7.1 LED... 13 7.2 Auto Set... 14 8 Programming... 16 9 Parameter list... 20 9.1 Terminals... 21 10 Technical data... 22 10.1 Dismantling and disposal... 25 10.2 US specifications... 25 10.3 Canada specifications... 25 11 Service... 26 12 Appendix... 27 Emotron AB 01-2150-01r3 1

2 Emotron AB 01-2150-01r3

1 Inside the box Please check the delivery. Despite the fact that all products from Emotron are carefully inspected and packed, transport damage may occur: Your shipment should contain the Emotron M10 shaft power monitor, a current transformer, 2x terminal covers (optional*) and this instruction manual. Check carefully that the equipment ordered complies with the motor's input voltage and that the current transformer rating is as stated on the delivery note. Check that the contents have not been damaged during transport. If something is missing, or has been damaged, contact the supplier as well as the forwarding agent within 48 hours of receipt. NOTE: If in doubt contact your supplier before installing or commissioning the product. Emotron M10 Shaft Power Monitor Instruction manual English *) Emotron AB 01-2550-01r3 Inside the box 3

2 Safety Read this manual thoroughly before installing and using the Emotron M10. The Emotron M10 must be installed by qualified personnel. Always disconnect supply circuits prior to installation. The installation must comply with standard and local regulations. Pay special attention to the information in this chapter and the parts marked WARNING and CAUTION in the chapter on operation. Check that the Emotron M10 and the equipment are correctly connected before use. Should questions or uncertainties arise, please contact your local sales outlet or see Chapter 11 page 26, Service. Faults that arise due to faulty installation or operation are not covered by the warranty. NOTE: Removing or tampering with the seal on the housing will invalidate the warranty. 4 Safety Emotron AB 01-2550-01r3

3 Description This instruction manual describes the installation and commissioning of the Emotron M10 shaft power monitor. The Emotron M10 is a single function monitor intended for machine builders and OEMs. It is the ideal choice for price sensitive applications requiring only basic under- or overload protection. For more advanced load monitoring we recommend the Emotron M20 shaft power monitor. The Emotron M10 is well suited for supervising induction motor driven equipment, such as centrifugal pumps, magnetic pumps, mixers, scrapers, crushers and conveyors in applications with drive motors of up to 50 A. It can also be used as an electronic shear pin (Motors max. 50A). The Emotron M10 provides reliable monitoring and protection, optimizing production equipment and minimizing expensive breakdowns and interruptions. It immediately detects any abnormal condition and initiates a warning. If the normal machine load level is exceeded, the internal relay changes state and the alarm LED turns red (LED is green at normal load). The output relay contact can be used for alarm indication and/or for machine shut-down. Shaft power is calculated by measuring motor input power and subtracting the motor power loss calculated using a unique principle. Calculating shaft power gives more reliable supervision than non-linear techniques, such as current and phase angle measurements. Current measurement is only sufficient at high motor loads and phase angle only at low loads. Input power, sometimes called true or real power, is linear but ignores motor power loss. Using the motor as its own sensor means no external sensors or extra cabling are required. By taking into account the motor power losses, the monitor is able to accurately measure the shaft power supplied by the motor to the application. This advanced technique allows the Emotron M10 to monitor the "application load" rather than the total motor load, which includes the varying motor losses. The monitor is easy to install and is mounted on a standard DIN rail. It is easy to select and set up the function you wish to use, for example under- or overload protection, relay function, response delay or alarm margin. The "Auto Set" function can be used to set the desired load level automatically. For further information, visit www.emotron.com. Emotron AB 01-2550-01r3 Description 5

4 Getting Started 4.1 Please take note of the safety section 1. Pay special attention to the safety section in this manual and the parts marked CAUTION. 2. Check that the motor/supply voltage corresponds to the values on the Emotron M10 product label at the side of the monitor. 3. Make a note of the motor's rated power and rated current from its nameplate. Confirm that the current transformer supplied is of the correct size according to table 1, page 11 in this manual. 4.2 Connection and set-up before first start 1. Connect the Emotron M10 according to Chapter 5 and Fig. 1. 2. Make sure all safety measures have been implemented and switch on the supply voltage - Power LED turns green. 3. Minimum parameters to be set are "Rated Power" and desired relay function "Max or Min", see Chapter 8, Table 2, 3 and Fig. 6. 4. Press PAR once - "LED" AUTO SET turns green. 5. Keep pressing PAR until the desired parameter is selected e.g. RATED POWER, see Chapter 8, Table 2 and 3. 6. Press VAL - Factory set value or earlier set value flashes e.g. "64". 7. Keep pressing VAL until desired value is displayed (0-64). 8. Confirm chosen value by pressing PAR. 9. Press PAR again and repeat steps 4 to 8 for all parameters except for AUTO SET. See Chapter 8, Table 2, 3 and Fig. 6 for possible value settings for each of the eight parameters. 10. Start and run the motor/system at normal load conditions, also wait until the START DELAY has expired. HINT! Short-circuit the output relay during the set-up, this prevents the equipment stopping unintentionally, see Hint! in Chapter 5. 11. Press PAR once - "LED" AUTO SET turns green. 6 Getting Started Emotron AB 01-2550-01r3

12. Press and hold VAL for 3 seconds, at normal machine load. The Auto Set load level is automatically set and the LED is switched off. 13. Set/reset e.g. start delay, response delay, margin, etc. if necessary (see Chapter 8, Table 2, 3 and Fig. 6). If the machines "normal" load level is exceeded, the internal relay change state and the alarm LED turns red (LED is green at normal load). Emotron AB 01-2550-01r3 Getting Started 7

1 2 5 Wiring The following wiring diagram provides an example of how the Emotron M10 can be connected to control the start/stop circuit of a three-phase motor, Fig. 1, page 8. Connections to a single-phase motor are described later in this manual (Fig. 2). 1. The current transformer CTMXXX must be placed in the same phase that is connected to terminal 9, phase L1, see Fig. 1. Failure to follow this requirement will result in the monitor failing to function. 2. For single-phase connection see Fig. 2, page 9. Normally the appropriate current transformer (CTM XXX) will have been ordered and shipped with the Emotron M10. Check that this is the case; see Chapter 6 page 11 Selection of current transformer, contact the supplier if in doubt. When using DC voltage, terminal 6 should be connected to negative polarity (ground) and terminal 5 to positive polarity (max. 48 VDC), see Fig. 1, page 8. See also the alternative auxiliary circuit Fig. 11, page 29. L1 L2 L3 9 L1 C 6 11 L2 M10 NC 7 CTMxxx 13 L3 S1 S2 NO 8 5 RES K1 K1 U V Max. 240 VAC (alt. 0 VDC-) K1 Please see CTM information on table 1, page 11. Note: Monitor voltage, see note on page 9. Stop Start N (alt. 48 VDC+) W M Fig. 1 Standard wiring 3-phase motors (alternatively see Fig. 11, page 29) 8 Wiring Emotron AB 01-2550-01r3

L 1 2 NOTE: The current transformer (CTMxxx) must be placed in the same phase that is connected to terminal 9, phase L1, see Fig. 1. Make sure that the Emotron M10 voltage range e.g. 3x100-600 VAC matches the connected motor/line voltage, e.g. 3x400V. Hint If the START/STOP is connected as per Fig. 1, it is recommended that terminals 6 and 7 be bypassed during settings. After the settings are completed the bypass must be taken out. Please use the enclosed plastic (rubber) insert (if ordered, optional) to cover the monitor terminals. Alternative example for single-phase connection This wiring example shows the alternative connection to be made with regard to a single-phase connection. Refer to Fig. 1 for the remaining wiring. L1 N 9 L1 C 6 CTMxxx 11 L2 13 L3 M10 S1 S2 NC NO 7 8 5 RES K1 N M Fig. 2 Single-phase wiring example (alternatively see Fig. 10, page 28) Emotron AB 01-2550-01r3 Wiring 9

5.1 Latched or un-latched alarm N (alt. DC+) MAX 240 VAC (alt. DC-) R E S E T Unlatched (Auto Reset) 5 6 7 8 5 6 7 8 Latched Un-Latched (Auto Reset) when voltage supplied to terminal 5 and 6. Latched Alarm when terminal 5 and 6 opened (not connected). Fig. 3 Wiring example for latched or un-latched alarm. When using DC voltage, alternatively see Fig. 11, page 29. If terminal 5 is not connected, see Fig. 3, the alarm is not automatically reset when the machine load is normal again after an alarm situation. The alarm is then latched; function "Latched alarm". The alarm can then be manually reset by pressing both PAR and VAL buttons at the same time for 3 seconds. It is only possible to reset an alarm if the power level is on the "right side" of the set alarm level (depending on under- or overload monitoring). If, however, terminal 5 is connected to an AC or DC signal the alarm will be reset automatically (un-latched alarm). This is only possible if the power level is on the "right side" of the set alarm level. 10 Wiring Emotron AB 01-2550-01r3

6 Selecting the current transformer 6.1 For motors up to 50 A 1. Check the rated motor current on the motor plate. 2. Compare this value with the rated motor current in Table 1. 3. From Table 1, select the current transformer and the appropriate numbers of windings. Table 1 Current transformer and number of primary windings. RATED MOTOR CURRENT (A) Number of primary windings CTM010 CTM025 CTM050 0.4-1.0 10 1.01-2.0 5 2.01-3.0 3 3.1-5.0 2 5.1-10.0 1 10.1-12.5 2 12.6-25 1 26-50A 1 6.1.1 Example Rated motor current = 12 A. Select 10.1-12.5 A from the first column in table 1 and choose CTM 025 with two (2) primary windings (the motor wire is drawn through the CTM hole twice). NOTE: Max. length of CTM cable is 1 m (39 inches). For motors with rated current over 50 A Emotron M20 must be used, contact your supplier. In order to ensure an accurate calibration of the Emotron M10, it is essential that you use the correct CTM and apply the exact number of windings in accordance with the above table. Emotron AB 01-2550-01r3 Selecting the current transformer 11

NOTE: Normally the appropriate Current Transformer (CTM XXX) will have been ordered and shipped with the Emotron M10. Check that this is the case; contact the supplier if in doubt. L1 L2 L3 CTM025 2 windings P2 1 2 S1 S2 M10 M 3 Fig. 4 Example CTM 025 with 2 windings for a 12 A motor CAUTION: Terminals 1 and 2 (S1, S2) carry live voltage. P2 1 2 5:1 5:2 5:3 Fig. 5 Example 1, 2 and 3 windings. NOTE: The current transformer connection and orientation are not polarity sensitive, but must be connected to the same phase that is being referenced for terminal 9 of the Emotron M10. 12 Selecting the current transformer Emotron AB 01-2550-01r3

7 Operation Make sure that the enclosed plastic (rubber) insert (if ordered, optional) covers the monitor terminals before you start programming. If the normal machine load level is exceeded, the internal relay changes state and the Power/Alarm LED turns red. The LED is green at "power on" and at normal load. 7.1 LED A constant green LED indicates a parameter type. A flashing green LED indicates a value. Under normal system operation, the eight LEDs are all off (see table 2, page 18). Any illuminated LEDs will be automatically switched off 30 seconds after the last key press. Emotron AB 01-2550-01r3 Operation 13

7.2 Auto Set The alarm load level is automatically set by the Auto set function, see Chapter 8 Current input Terminal 1 and 2. Current Transformer; CTM 010, 025 or 050 (Max. 50 A motor). Power/Alarm The Power/Alarm LED turns green at "power on" and at normal load. Red at alarm. PAR Parameter change (LED light constant green) - pressing PAR key when parameter is displayed proceeds to next parameter. 1S1 Rated Power Relay Inverted Alarm Current=0 Max Or Min Response Delay Start Delay Margin Auto Set 9 L1 2 S2 Power / Alarm PAR 5 RES RESET 3s. 6 C 64 32 16 8 4 2 1 0 VAL 7 NC M10 11 L2 13 L3 Reset Reset a latched alarm by pressing both PAR and VAL at the same time for 3 seconds. 8 NO Reset input Terminal 5 and 6 are used for external reset and selection of latched/unlatched alarm. Relay output Terminal 6, 7 and 8 output relay. VAL Value setting - Pressing VAL key when green LED is flashing increases value. A changed value is confirmed by pressing PAR. Motor terminals Terminal 9 (L1), 11 (L2) and 13 (L3) for supply and motor voltage input. The value for a parameter, e.g. seconds, kw, HP or margin, can only be set as 0, 1, 2, 4, 8, 16, 32 or 64. Select closest value. The Emotron M10 with article number 01-3160-00 "Fast Response" (M10 FR) is identical with the standard Emotron M10 except for where the start-up delay and the response delay are shorter than below: Article number 01-2487-10 standard Emotron M10: RESPONSE DELAY: 0.05-64 s START-UP DELAY: 1-64 s Article number 01-3160-00 "Fast Response" (M10 FR): RESPONSE DELAY: 0.05-6.4 s START-UP DELAY: 0.1-6.4 s 14 Operation Emotron AB 01-2550-01r3

The Emotron M10 is a single function monitor intended for machine builders and OEMs. It is the ideal choice for price sensitive applications requiring only basic under- or overload protection. If the operator needs to know the normal load level and set load level of the output shaft power either in percent or kw/ HP the Emotron M20 must be used. Emotron AB 01-2550-01r3 Operation 15

8 Programming Set-up and program the Emotron M10 according the "Example" on page 17, see also table 2, page 18, table 3, page 19 and Fig. 7, page 19. In Chapter 4 more information and hints are given about connection and setup before the first start-up. Rated Power Relay Inverted Block Current =0 Max or Min Response Delay Start Delay Margin Aut set 64 32 16 8 4 2 1 0 Parameter change (LED light constant green) Value setting (Green LED is flashing) Fig. 6 Parameter change and value setting. 16 Programming Emotron AB 01-2550-01r3

When the Emotron M10 is installed, the machine is running, and the normal machine load level is exceeded, the internal relay changes state and the Power/ Alarm LED turns red. The LED is green at normal load. CAUTION: Make sure that all safety measures have been taken before switching on the supply voltage and starting the motor/machine in order to avoid personal injury. Example: Conveyor with overload protection Conveyor with overload protection, motor 11 kw (Fig. 7, page 19). 1. Check output power on motor plate and see table 3 (11 kw = Rated Motor Power 6.1-12) - setting 8. 2. Switch on the supply voltage - Power LED green. 3. Press PAR once - LED AUTO SET turns green. 4. Keep pressing PAR until RATED POWER is selected, see Fig. 6, page 16. 5. Press VAL - Value 64 flashes (factory setting). 6. Set recommended value according to table 3. Keep pressing VAL until chosen value (8) flashes. 7. Confirm chosen value by pressing PAR. 8. Press PAR again and select MAX. 9. Press VAL. Choose the factory setting MAX - Overload Protection - 1. 10. Confirm chosen value (1) by pressing PAR. 11. Press PAR again and select RELAY INVERTED. 12. Press VAL. Choose the factory setting no = 0. 13. Confirm chosen value (0) by pressing PAR. The above parameters are necessary to set for safe functioning. Note that Rated power for the motor must be set before Auto Set. Hint Change the load on the machine to find out if appropriate load limit margin is set correctly. You can also reduce the margin by one or more steps to find out at what level the machine will trip. See Fig. 7, page 19. Set/reset e.g start delay, response delay, trip margin etc. if necessary (see table 2, page 18). Emotron AB 01-2550-01r3 Programming 17

More hints If the alarm level is difficult to set - simply perform an Auto Set when the motor is stopped. Then start the machine, run at normal load and perform an Auto Set again. If a wrong value is unintentionally set - simply set a new value. If the value is not confirmed by pressing PAR, the new value is not accepted (time out after 30 seconds). Table 2 Parameters and values. Parameter Value Factory setting Note RATED POWER 0 1 2 4 8 16 32 64 64 See table 3 RELAY INVERTED 0 (no) 1 (yes) 0 0 = Relay activated at alarm ALARM CURRENT = 0 0 (no) 1 (yes) 0 Alarm at no motor current MAX OR MIN 0 (MIN) 1 (MAX) 1 RESPONSE DELAY 0 1 2 4 8 16 32 64 2 0 = under load 1 = overload alarm Response delay in seconds (0=50 ms) START DELAY 0 1 2 4 8 16 32 64 2 Start delay in seconds MARGIN (% of rated power) AUTO SET 0 1 2 4 8 16 32 64 8 Auto Set load level is automatically set if VAL key is pressed for 3 seconds. Load change for alarm sensitivity, Fig. 7 VAL key must be pressed when LED parameter AUTO SET is light. LED bar is switched off when Auto Set level is set. 18 Programming Emotron AB 01-2550-01r3

Table 3 Setting of rated motor power. Setting Rated motor power in kw or HP 0 0-0.5 1 0.51-1.5 2 1.51-2.5 4 2.51-6 8 6.1-12 16 12.1-24 32 24.1-48 64 48.1-75 Overload protection Underload protection Power Alarm level (overload monitor) Start-up Overload (MAX) Power Start-up Margin Power at AUTO SET (Auto Set load Level) Power at AUTO SET (Auto Set load Level) Margin t Alarm level (underload monitor) Underload (MIN) t Fig. 7 Alarm level and margin. Emotron AB 01-2550-01r3 Programming 19

9 Parameter list Table 4 Parameter list Parameter Factory setting Actual setting Alt. setting Rated power 64 Relay inverted 0 Alarm current = 0 0 Max or Min 1 Response delay 2 Start delay 2 Margin 8 20 Parameter list Emotron AB 01-2550-01r3

9.1 Terminals Table 5 Terminals and labels Terminal Label Function 1 S1 Current transformer input for CTM 010, CTM 025 or CTM 050, blue wire 1 2 S2 Current transformer input, brown wire 1) 3 (not used) 4 (not used) 5 RES Reset input. Latched or unlatched alarm is selected via this input. Connect to + at DC. 6 C Alarm relay common and also reset common. Connect to - at DC. 7 NC Alarm relay normally closed 8 NO Alarm relay normally open 9 L1 Motor voltage phase L1 10 (not used) 11 L2 Motor voltage phase L2 (N for single phase motors) 2) 12 (not used) 13 L3 Motor voltage phase L3 (N for single phase motors) 2) 1) Note! Terminals 1 and 2 (S1, S2) carry line voltage. 2) N must be connected to terminal 11 and 13 (single phase). Emotron AB 01-2550-01r3 Parameter list 21

10 Technical data 45x90x115 mm (1.77" x 3.54" x 4.53") Dimensions (WxHxD) 35mm (1.38") 26mm (1.02") 90mm (3.54") 45mm (1.77") 115mm (4.53") Mounting 35 mm DIN-rail 46277 Weight 175 g (5.65 oz) Supply voltage (VAC)* Frequency Current input Power consumption Start-up delay Response delay Relay output Fuse Terminal wire size Terminal tightening torque Repeatability Temperature tolerance 1x100-240 (± 10 %) 3x100-600 (± 10 %) 3x600-690 (± 10 %) 50 or 60 Hz Current transformers; CTM 010, 025 or 050 (Max 50 A motor) Max 3 W 1-64 s ( Fast response, see page 14; 0.1-6.4s) 0.05-64 s ( Fast response, see page 14; 0.05-6.4s) 5 A/240 VAC Resistive, 1.5 A/240 VAC Pilot duty/ AC12 Max 10 A Use 75 C copper (CU) wire only. 0.2-4.0 mm 2 single core (AWG12). 0.2-2.5 mm 2 flexible core (AWG14), stripp length 8 mm (0.32") 0.56-0.79 Nm (5-7 lb-in) ± 2.5% FS, 24 H, @ +25 C (+77 F) <0.1%/ C 22 Technical data Emotron AB 01-2550-01r3

External RESET on term. 5 Operating temperature Storage temperate Protection class RoHS directive Approved to Max 240 VAC or 48 VDC. High: 24 VAC/DC Low:< 1 VAC/DC. Reset >50 ms -20 (4 F) +50 C (+122 F) -30 (22 F) +80 C (+176 F) IP20 2002/95/EC CE (up to 690VAC), UL and cul (up to 600 VAC) *)Please note that these are separate voltage units; see table 6 with ordernumbers Table 6 Order numbers and designation Order number Designation 01-2487-10 Emotorn M10 1x100-240/3x100-690 VAC 01-3160-00 Emotorn M10 1x100-240/3x100-690 VAC Fast response 10.0.1 Technical Data for Current Transformer (CT) Type Dimensions (WxØ) Weight* Mounting CTM 010 27(35) X Ø48mm 0.20 kg 35mm DIN rail 46277 CTM 025 27(35) X Ø48mm 0.20 kg 35mm DIN rail 46277 CTM 050 27(35) X Ø48mm 0.20 kg 35mm DIN rail 46277 *) Weight including 1 m (39 inch) cable. Please note that max. length of the CT cable is 1 m and this cable can not be extended. Emotron AB 01-2550-01r3 Technical data 23

4. 3 10. 3 17 48 27 42 35 78 45 35 Fig. 8 Current Transformer CTxxx. 10.0.2 Accessories and documentation Order number Designation 01-2471-10 Current Transformer (CT) CTM010, max. 10A 01-2471-20 Current Transformer (CT) CTM025, max. 25A 01-2471-30 Current Transformer (CT) CTM050, max. 50A 01-2368-00 Front Panel Kit 1 (2x terminal covers included) 01-4136-01 2x terminal covers 01-2550-00 Instruction manual (Swedish) 01-2550-01 Instruction manual (English) 24 Technical data Emotron AB 01-2550-01r3

10.1 Dismantling and disposal The product is designed to comply with the RoHS directive, and shall be handled and recycled in accordance with local legislations. EU (European Union) specifications EMC EN 61000-6-3, EN 61000-6-2 EN 61000-4-5 Electrical safety EN 60947-5-1 Rated insulated voltage 690 V Rated impulse withstand voltage 4000 V Pollution degree 2 Terminals 3, 4, 5, 6, 7 and 8 are basic insulated from the line. Terminals 3 and 4 are basic insulated from terminals 5, 6, 7 and 8. 10.2 US specifications FCC (Federal Communications Commission) This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference, in which case, the user will be required to correct the interference at their own expense. 10.3 Canada specifications DOC (Department of communications) This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the Canadian Interference-Causing Equipment Regulations. Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada. Emotron AB 01-2550-01r3 Technical data 25

11 Service This manual is valid for the following model: Emotron M10. Document number: 01-2550-01 Document version: r3 Date of release: 2009-09-15 Emotron AB reserves the right to alter product specifications without prior notification. No part of this document may be reproduced without permission from Emotron AB. For more information contact your local sales outlet or visit us at: www.emotron.com Protected by utility patents EP 1027759 and US 6879260 26 Service Emotron AB 01-2550-01r3

12 Appendix Max. 240 VAC (alt. 0 VDC-) Stop Start 9 11 13 6 7 8 5 1 2 L1 L2 L3 CTMxxx L1 C L2 L3 M10 NC NO S1 S2 K1 RES K1 N (alt. 48 VDC+) K1 U V W M Please see CTM information on table 1, page 11. Note: Monitor voltage, see note on page 9. Fig. 9 M10 connection example Emotron AB 01-2550-01r3 Appendix 27

L1 N CTMxxx K1 L N M 9 11 13 L1 L2 L3 S1 M10 S2 C NC NO 6 7 8 5 RES 1 2 Fig. 10 M10 single-phase connection example 28 Appendix Emotron AB 01-2550-01r3

6 7 8 5 0VDC- 24VDC+ 1 2 L1 L2 L3 CTMxxx 9 11 13 L1 C L2 L3 M10 NC NO S1 S2 RES U V W M Fig. 11 M10 example of auxiliary circuit when VDC is used. Emotron AB 01-2550-01r3 Appendix 29

30 Appendix Emotron AB 01-2550-01r3

Emotron AB, Mörsaregatan 12, SE-250 24 Helsingborg, Sweden Tel: +46 42 16 99 00, Fax: +46 42 16 99 49 E-mail: info@emotron.se Internet: www.emotron.com Emotron AB 01-2550-01r3 2009-09-15