Hoval BioLyt (8-36) Pellet boiler

Similar documents
Hoval BioLyt (50-160) Pellet boiler

Hoval AgroLyt (20-50) Log Wood Boiler

Hoval TopGas classic (12,18,24,30) Wall-hanging gas condensing boiler with or without water heating

Max-3 plus. Output range 420 to 2700 kw TopTronic E control. Steel Shell Boiler. Responsibility for energy and environment

GAS Hoval Responsibility for energy and environment. Hoval heating technology Hoval residential ventilation Hoval indoor climate systems GAS

Technical information Installation instructions

Steel Shell Boilers. Max-3 plus kw. Max-3 E & Max-3 condens E kw. CompactGas kw. SR-plus and SR-H plus kw

Hoval Uno-3 ( ) Low temperature oil/gas boiler

Hoval UltraGas ( ) Floor-standing gas condensing boiler

Technical information Assembly instructions. UltraOil ( ) Oil condensing boiler

Hoval TopGas (12, 16, 22)

Technical information Assembly instructions

HDG K SERIES. Wood pellet boiler. The perfect alternative to fossil fuels. Receive up to

CALORIFIERS (Energy Storage Tanks) for domestic, commercial and industrial applications.

THW-I NTE. Description THW-I NTE. Industrial Hot Water Boiler THW-I NTE for Oil or Gasfiring. Industrial Hot Water Boiler

and Installation Instructions The installation instructions for the Unit pressure jet oil burner is included in the pressure jet oil burner pack.

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

1 VICTRIX ZEUS Superior kw I features

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

High Performance Electronic Modulation Automatic Cleaning Easy Installation 4 Power Levels: 9,15,25,42kW. Pellet Boilers. Future of Ecological Heating

Technical information Installation instructions. Modul-plus (F21-52) High performance calorifiers

VIESMANN VITOROND 100. Datasheet Part numbers and prices: see pricelist VITOROND 100. Cast iron low temperature oil and gas fired boiler.

Biomass. Biomass solid fuel boiler range

ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS

Installation, operation and care. Pellmax UB. Burner not included Replaces:

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS

Technical information Installation instructions. Uno-3 ( ) Oil/gas boiler. These instructions apply to the following types:

WOLF GAS CONDENSING BOILERS COMFORTLINE

MANUAL. Page 1/44

ETA PE-K. The pellet boiler with technology that's built to last, for larger heating needs. 35 to 90 kw. A passion for perfection.

PZ35RL BIOTECH THE FUTURE OF HEATING PZ 35 RL

2x58 MW Coal Fired Power Plant at Mauritius

Hoval SR-plus heating boilers Outputs from 350 to 4000kW Working pressures to 8 bar

VIESMANN VITOCROSSAL 300 Gas condensing boiler 187 to 635 kw

ELECTRIC BOILERS FOR CENTRAL HEATING

INSTALLATION, OPERATION AND MAINTENANCE. ARITERM SWEDEN AB Installation, Operation & Maintenance /28

TopGas Cascade Condensing Gas Boilers Technical Information and Assembly Manual Output range 60 to 720 kw /17 Subject to modification

Operating manual. Pellet boiler. Orlan Pellet ISO 9001

VICTRIX Superior kw Export VICTRIX Superior kw X Export

Boiler Technical Specifications (2013)

Installation and operating instructions. DK energy storage and DK energy buffer

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

Operating manual. Wood pellet boiler. PL M 15 and PL M 25

Technical information Installation instructions

Technical information Assembly instructions. Uno-3 (320, 360) Oil/gas boilers

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

Installation, operation and care Firewood boiler Vedolux 40 UB

INSTALLATION AND OPERATION MANUAL

Technical information Installation instructions

Wood gasification process...3. Wood as a fuel...3. Boiler construction - its elements...4

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

English. Heating with logs & wood pellets 20-40

Pellet boiler Electronic Modulation Automatic Cleaning Grinder system Easy Installation 4 power levels: 10, 16, 25, 43 kw

Heating with wood pellets kw

Technical information Installation instructions. 41-TopGas (80) Gas condensing boiler for natural and liquid gas

VIESMANN. VITOMAX 200-LW Low pressure hot water boiler for permissible flow temperatures up to 120 C Rated heating output 8.0 to 20.0 MW.

Heating with log wood

ENTROPIE boiler TT300

Hoval Cosmo heating boilers, outputs from 100 to 4000kW. Working pressures to 8 bar. Heatpack boilers. to 2900kW.

Wood chip boiler T

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity

Starting current with soft starter Fuse protection. Connection heating Seal of approval MCS (valid until)

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

Logamax plus GB172/GB172T. Heat is our element. Technical Guide Issue 2011/06. Fügen Sie auf der Vorgabeseite das zur Produktgruppe passende Bild ein.

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOCELL 300-V. Vertical DHW cylinder. 130to500litrecapacity. Vitotec folder, register 17

VIESMANN. Datasheet For part no. and prices: see pricelist VITOLIGNO 300-P. Pellet boiler 4to48kW. Vitotec folder, register 12. File in: Type VL3B

Ca 6s and BCa 6s kw INSTALLATION AND OPERATING INSTRUCTIONS. Page 1 31/07/00

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser

Starting current with soft starter Fuse protection

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Easyfire Standalone biomass pellet boiler

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Hoval Cosmo Combination boilers. High efficiency heating combined with economic DHW generation. Boiler outputs from 100 to 1450kW.

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

Installation instructions PYROMAT ECO. for contractors PYROMAT ECO GB 8/2012 Dispose after installation.

VIESMANN. VITOMAX 200-WS Rated heating output 1.75 to MW. Datasheet. VITOMAX 200-WS Type M250

Safety vacuum drying oven for flammable solvents

Pellet Boiler VITOLIGNO 300-P. Test winner Good (2.1) Pellet boiler VITOLIGNO 300-P. In the test: 10 systems 1 winner

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

Heating with wood chips

Installation and Operation Instructions Domestic hot water module FriwaMini with circulation - DN 15

Floorstanding Gas Condensing Boilers VITOCROSSAL 100

INSTALLATION INSTRUCTIONS LOGWIN PREMIUM TOUCH WOOD GASIFICATION BOILER 06/ /00

Trade Product List 2013 BIOMASS ACCESSORIES

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

WOOD GASIFYING BOILER ATTACK DPX STANDARD / PROFI / LAMBDA INSTRUCTIONS FOR USE WWW. ATTACK.SK

Technical data LA 60TUR+

Boiler controller Lambdatronic S 3200

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model CLAS. R EN - Edition 01-01/02/2007

Hydraulic Installation

for contractors Vitoplex 200 Type SX2A For applicability, see the last page Please keep safe.

VIESMANN VITOCROSSAL 300 Gas condensing boiler 787 to 1400 kw

Transcription:

Pellet boiler Description Hoval BioLyt Boiler Steel boiler for the combustion of wood pellets of Ø 6 mm, max. length 30 mm manually or automatically Pellet metering screw with rotary valve for fuel supply Electric heating element for automatic ignition Fully automatic removal of ash from the burner Burner made from highly heat-resistant stainless steel icroprocessor-controlled combustion regulation with combustion chamber temperature sensor and lambda probe draught fan for modulating power adjustment Negative pressure monitor in the combustion chamber Automatic heating surface cleaning Fully automatic ash discharge the rear Thermal insulation on the boiler body with 80 mm mineral wool mat Casing made from sheet steel, red powdercoated No thermal discharge safety device required Boiler controller TopTronic T/U5.2 technology Integrated control function for - 1 mixer circuit - Hot water loading circuit Optional expanded functionality with - various key modules (see Accessories) Safety temperature limiter Automatic operating system with display of the respective operating state chamber Return temperature control function Prepared for connection of the fully automatic pellet feed Electrical connection 230V, 50 Hz Fault display «Burner» Operating hours and pulse counter Outdoor sensor AF200 Flow sensor (contact sensor VF204) Return sensor (cable sensor KVT 20/5/6) Boiler sensor installed Connection available for room stations Series BioLyt Type Heat output kw (8) 2,1-7,9 (13) 3,9-13,0 (15) 4,4-14,9 (23) 6,5-23,0 (25) 7,3-24,9 (31) 8,7-31,0 (36) 9,8-36,0 Design on request Fully automatic pellet feed comprising: - Feed unit with suction turbine and controller - Automatic switchover unit - 3 suction probes - Conveyor and return air hose. BioLyt with pellets from the storage area ful ly automatically via a maintenance-free suc tion turbine. Filling is controlled via a the pellets from the storage area is effected via 3 switchable suction probes, so that the storage area can be practically completely emptied. tanker Tested to EN 303-5. Delivery Boiler with thermal insulation, casing, burner, pellet hopper and ash box as well as boiler controller are delivered in separate packaging. On site Installation of the boiler (bottom section and heat exchanger) Installation of burner and pellet hopper Installation of boiler controller Installation of the casing Fabric tank for pellets and "mole" extraction system see end of this brochure Subject to alterations, 1.8.2013 21

Part N Pellet boiler Hoval BioLyt Part N Steel boiler for the combustion of wood pellets, with integrated TopTronicT/U5.2 basic boiler controller and heating regulator incl. sensor. Integrated control function for: - 1 mixer circuit - hot water loading circuit Optional expanded functionality with key modules. With pellet hopper, automatic heating surface cleaning and fully automatic ash discharge. Delivery and boiler controller are delivered separately packed. BioLyt Nominal Pellet Pellet hopper output length, Ø content max. Type kw mm mm kg (8) 2,1-7,9 30 6 90 (13) 3,9-13,0 30 6 90 (15) 4,4-14,9 30 6 90 (23) 6,5-23,0 30 6 90 (25) 7,3-24,9 30 6 90 (31) 8,7-31,0 30 6 90 (36) 9,8-36,0 30 6 90 7010 373 7010 374 7010 375 7010 376 7010 377 7010 378 7010 379 Extraction system Automatic conveyance of pellets from the storage area into the pellet hopper of the BioLyt. Comprising feed unit RAS 81 for suction system with suction probes, screw discharge or mole. aximum distance: Transport length [m] max. possible delivery height [m] 15 to 25 1.8 10 to 15 2.8 5 to 10 4.5 Feed unit RAS 81 For installation into the pellets box at the boiler. Consisting of maintenance-free suction turbine with mounting flange and level indicator. 6027 958 Switchover unit and pellet storage systems see Pellets storage 22 Subject to alterations, 1.8.2013

Hoval BioLyt (8-36) Part N Accessories for TopTronic T heating regulation system Part N 1-7 Key modules for the Hoval TopTronic T for further functions in addition to the standard functions. Key module consisting of: Function key for insertion in the TopTronic T including accessories Only one key module possible per controller! Standard functions already included in the TopTronic T. - 1 mixer circuit - hot water loading circuit Functions of the key modules Key 2nd mixer Solid/buffer/ Solar module circuit bivalent 1 2 3 4 5 6 7 1 Key module 1 for 2nd mixer circuit Function key 1, 1 flow sensor, 2 loose plugs 6012 154 2 Key module 2 for solid fuel/ buffer storage tank/ bivalent installation Function key 2, 3 immersion sensors, 4 loose plugs 6012 155 3 Key module 3 for solar energy systems Function key 3, 1 collector sensor, 1 calorifier sensor, 4 loose plugs 6012 156 4 Key module 4 for 2nd mixer circuit and solid fuel/ buffer storage tank/ bivalent installation Function key 4, 1 flow sensor, 3 immersion sensors, 6 loose plugs 6012 157 5 Key module 5 for 2nd mixer circuit and solar energy system Function key 5, 1 flow sensor, 1 collector sensor, 1 calorifier sensor, 6 loose plugs 6012 158 6 Key module 6 for solid fuel/buffer storage tank/bivalent installation and solar energy system Function key 6, 1 collector sensor, 4 immersion sensors, 6 loose plugs 6012 159 7 Key module 7 for 2nd mixer circuit, solid fuel/buffer storage tank/ bivalent and solar energy system Function key 7, 1 flow sensor, 1 collector sensor, 4 immersion sensors, 8 loose plugs 6012 160 System solutions and applications see Hoval CD Sensor types Immersion/calorifier sensor: Type KVT20/5/6 (L = 5 m) without immersion sleeve Flow sensor : Type VF204S with plug Collector sensor : Type PT1000 (silicon) Subject to alterations, 1.8.2013 23

Part N Accessories for TopTronic T heating regulation system Room station RS-T for TopTronic T effective on one mixing circuit Part N 2034 939 Remote control RFF-T for TopTronic T effective on one mixing circuit 2022 239 Outdoor sensor AF 200 (may be included in the heat generator scope of delivery) for one mixing circuit or for the mean value (per regulator 2 outdoor temperature sensors possible) 2022 995 Cable sensor KVT 20/5/6 with 5 m cable 2022 992 Contact sensor VF204 can be used as flow or return flow sensor with 4 m cable 2023 998 H_Strap-on-/immers.therm.RAK-TW.1000S- HV 2429 02 Thermostat RAK-TW1000S w. immersion sl. 6010 082 24 Subject to alterations, 1.8.2013

Part N Accessories Safety set SG15-1" Suitable up to max. 50 kw complete with safety valve (3 bar) Pressure gauge and automatic air vent with cut off valve Connection: 1" internal thread Part N 6411 84 Pressure expansion tank with threaded connections, permissible operating temperature 70 C Pre-pressure 1.5 bar permissible operating overpressure 6 bar Type Colour ø D H h A mm mm mm NG25 rot 280 465 - R¾" NG35 rot 354 460 130 R¾" NG50 rot 409 493 175 R¾ NG80 rot 480 565 175 R1 NG100 rot 480 670 175 R1 NG140 rot 480 912 175 R1 2427 91 2427 92 2026 088 2026 089 2026 090 2026 091 Quick connection SU R¾ x ¾ for diaphragm-type expansion chambers in closed heating and cooling water plants. With shut-off valve against unintended closing (check ball) and drain according to DIN 4751 Part 2, tested by TÜV Connection R ¾" 2427 71 Quick connection SU R 1 x 1 for diaphragm-type expansion chambers in closed heating and cooling water plants. With shut-off valve against unintended closing (check ball) and drain according to DIN 4751 Part 2 tested by TÜV Connection R 1" PN10/120 C 2427 72 Further vessels see separate brochure Subject to alterations, 1.8.2013 25

Part N Accessories Part N Return temperature control group DN25 to increase the return temperature With 3-way motor mixer and high-efficiency Biral pump, wired and ready-to-connect Ball valves in the plant flow/return Thermometer/valve in the boiler return Insulated piping Complete with fittings for final assembly on the boiler connection Connection: Rp 1" or 1¼" Pump enclosed separately. for BioLyt (8,13) DN25 3 /h for BioLyt (15,23) DN25 3 /h for BioLyt (25,36) DN32 3 /h 6032 421 6032 422 6032 453 Return temperature control kit DN25 for BioLyt (8-23) Consisting of: 3-way motor mixer 6027 842 Return temperature control kit DN25 for BioLyt (15,23), AgroLyt (20,25) for return flow temperature increase Consisting of: 3-way motor mixer kvs: 12 m 3 /h 6032 419 Return temperature control kit DN32 for BioLyt (25-36), AgroLyt (35,50) for return flow temperature increase Consisting of: 3-way motor mixer kvs: 18 m 3 /h 6027 843 26 Subject to alterations, 1.8.2013

Part N Accessories Flue gas thermometer with drag indicator Ø 5 / 80x150 mm (mounting on site) Range of indication 100 C - 500 C Part N 2412 37 Three way valve B3G460 PN 10, 110 C, DN 32 case, shaft and segment made of brass maintenance-free O-ring seal ounting optionally on left or right side kvs value 18 m 3 /h 2039 170 Actuator NR230-E-20 for three-way valve B3G460 Operating voltage 230V/50Hz Single wire control Torque 10 Nm Actuation time 140 s manual/automatic positioning reversible direction of rotation and scale for position indicator 0...10 1 cable (2 m) for actuator mounted on the drive. Complete with assembly material 2452 35 Damper ZET 13 for BioLyt (8-23) Damper EZ with explosion door and T-piece of stainless steel 90. Inner Ø 130 mm 6411 61 Damper ZET 15 for BioLyt (25-36), (50,70) Damper EZ with explosion door incl. T-piece of stainless steel 90. Inner Ø 150 mm 6008 032 Subject to alterations, 1.8.2013 27

Technical data Type (8) (13) (15) (23) (25) (31) (36) Nominal heat output kw 7,9 13,0 14,9 23,0 24,9 31,0 36,0 Firing capacity with nominal heat output kw 8,3 13,7 15,6 24,2 26,3 32,3 37,5 Heat output range kw 2,1-7,9 3,9-13,0 4,4-14,9 6,5-23,0 7,3-24,9 8,7-31,0 9,8-36,0 Pellets Ø mm 6 6 6 6 6 6 6 Length mm 5-30 5-30 5-30 5-30 5-30 5-30 5-30 C 75 75 75 75 75 75 75 inimum boiler operating temperature C 60 60 60 60 60 60 60 inimum boiler return temperature without/with buffer C 20/40 20/40 20/40 20/40 20/40 20/40 20/40 Flue gas temperature at nominal heat output C 120 120 120 120 120 120 120 Flue gas temperature at lowest heat output C 90 90 90 90 90 90 90 Carbon dioxide CO 2 at nominal output % 11 11 12 12 13 13 13 Operating/test pressure bar 3,0/4,5 3,0/4,5 3,0/4,5 3,0/4,5 3,0/4,5 3,0/4,5 3,0/4,5 % >93 >93 >93 >95 >95 >95 >95 kg/h 20,3 33,5 35,5 53,6 54,0 67,3 79,1 Pellet moisture content 10 % kg/h 7,1 12,5 12,2 18,0 19,4 23,2 26,1 Flow resistance wood pellet boiler z-value 13 13 19 19 9 9 9 Hydraulic resistance at 10 K mbar 6 12 34 56 40 63 66 Hydraulic resistance at 20 K mbar 2 4 10 15 11 17 18 m³/h 0,69 1,12 1,29 1,97 2,15 2,66 3,09 m³/h 0,34 0,56 0,65 0,99 1,08 1,33 1,55 Boiler water content litres 40 40 52 52 78 78 78 Pellet hopper capacity kg 90 90 90 90 90 90 90 Ash chamber content litres 28 28 28 28 28 28 28 Thickness of thermal insulation on boiler body mm 80 80 80 80 80 80 80 Boiler weight incl. casing kg 360 360 390 390 440 440 440 Flue gas system 1 inimum boiler draughting requirements Pa 5 (1) 2 5 (1) 2 5 (1) 2 5 (1) 2 5 (1) 2 5 (1) 2 5 (1) 2 Electrical power consumption during operation watts 33 46 57 107 118 141 160 Electrical power consumption during ignition watts 300 300 300 300 300 300 300 Electrical power consumption during standby watts 10 10 10 10 10 10 10 Fully automated pellet feed (only in operation alternating with wood pellet boiler) Electrical power consumption during pellet feed watts 1900 1900 1900 1900 1900 1900 1900 aximum current consumption 3 A 9 9 9 9 9 9 9 1 A damper and explosion damper must be installed. 2 In borderline cases, a draughting requirement of 1 Pa at lowest output can be assumed for calculation purposes. 3 Fuse protection min. 16 A slow-blow due to operating current. 28 Subject to alterations, 1.8.2013

Dimensions Space requirement (dimensions in mm) 1 Boiler flow (8-23) 1" / (25-36) 5/4" 2 Boiler return (8-23) 1" / (25-36) 5/4 3 Drain ½" 4 Boiler controller 5 Boiler temperature sensor 6 Boiler return sensor and STB 7 Lambda probe 8 Flue gas sensor 9 Flue gas outlet (8-23) Ø 128mm / (25-36) Ø 148 mm 10 Induced draught fan Optional: 11 Pellet feed suction turbine 12 Connection for conveyor hose Ø 50 mm 13 Connection for return air hose Ø 50 mm BioLyt A B C D E H (8-13) 1010 996 1061 741 316 1274 (15-23) 1210 1180 1261 861 316 1474 (25-36) 1365 1254 1423 1042 311 1667 Subject to alterations, 1.8.2013 29

Dimensions Overall unit dimensions (dimensions in mm) Boiler H A Weight BioLyt mm mm kg (8-13) 600 534 85 (15-23) 800 534 104 (25-36) 985 570 148 Boiler bottom section Weight 144 kg For easier installation (weight saving), dust separators (6,7 kg) and post-combustion ring (10,7 kg) can be removed. 30 Subject to alterations, 1.8.2013

Engineering Damper and explosion damper The installation of a damper with deflagration flap (explosion damper) is mandatory. Flue gas system A moisture-resistant chimney is required. Draughting requirement 10 Pa. Route the con necting line (flue gas pipe) with an upward slope, maximum length 3 m. Provide thermal insulation of at least 30 mm for the flue gas pipe. Where possible, flue connection 45. Do not wall in the flue gas pipe directly, but in tegrate it flexibly to avoid noise transmission. The flue gas pipe must be integrated in the flue gas duct in such a way that condensation cannot flow into the boiler. Buffer storage tank A small buffer storage tank optimises the op er ation of a pellet heating system and is rec ommended. those cases where parts of the heat supply system are frequently disconnected or in the case of high passive solar input, a buffer storage tank is mandatory. Selection of a buffer storage tank Recommended minimum tank size at a nominal load less than 70% of the boiler nominal load or high passive solar input. BioLyt Type Tank volume approx. litres (8-15) 200 (23,25) 300 (31,36) 500 In many cases, a buffer storage tank is necessary for water heating or integration of a solar energy system. Recommended capacity: 10-30 litres/kw boiler output plus volume for water heating and solar energy system. Detailed dimensioning of the system is necessary. Return temperature control Please observe the hydraulic example applications. Water quality Heating water: ÖNOR H5195, European Standard EN 14868 and VDI Guideline 2035 must be complied with. Hoval boilers and calorifiers are suitable for heating systems without significant oxygen intake (system type I in accordance with EN 14868). Systems with - continuous oxygen intake (e.g. underfloor heating systems without diffusionproof plastic piping) or - intermittent oxygen intake (e.g. frequent topping-up required) must be equipped with separate circuits. Treated heating water must be tested at least 1x per year, or more frequently if prescribed by the manufacturer of the inhibitor. On existing systems (for example if the boil er is replaced), where the quality of the ex ist ing heating water meets the requirements of VDI 2035, re-filling of the system is not recommended. The requirements of VDI 2035 also apply to replacement water. Before filling new systems and, where necessary, existing systems, the heating system must be professionally cleaned and flushed! The boiler must not be filled until the heating system has been flushed. All parts of the boiler which come into contact with water are made of ferrous materials and stainless steel. Due to the danger of stress corrosion, the sum of the chloride, nitrate and sulphate con tents of the heating water must not exceed a total of 50 mg/l (ÖNOR H5195 stipulates that the limit value for chlorides is 30 mg/l). The ph-value of the heating water should be between 8.3 and 9.5 after 6-12 weeks of heating operation. Filling and replacement water: As a rule, untreated drinking water is best suited as filling and replacement water for a system with Hoval boilers. However, the quality of the untreated drinking water must still meet the requirements of VDI 2035 or be demineralised and/or treated with inhibitors. The requirements of EN 14868 must be met in this context. To maintain high boiler efficiency and prevent overheating of the heating surfaces, the values in Table 1 should not be exceeded, taking into consideration the boiler output (smallest individual boiler in multi-boiler plants) and the water content. The total quantity of filling and replacement water added to the boiler over its service life must not be higher than twice the system water content. Combustion air supply An adequate combustion air supply is a pre requisite for safe and economical operation. Free supply air cross-section at least 200 cm 2. It is very important to ensure that the combustion air is clean and free from halogen compounds. These are present, for example, in spray cans, varnishes, glues, solvents and cleansing agents. Electrical connection The boiler is only suitable for installation in dry rooms (protection rating IP 10). Installation must be performed by an authorised electrician and in accordance with local regulations! Electrical connection: 230 V, 50 Hz, min. 16 A slow-blow. Caution: Connect phases correctly! An omnipolar main switch with a minimum contact spacing of 3 mm must be installed on-site, outside the boiler room. Installation instructions Please observe the installation instructions supplied with every boiler. Pellet storage systems see separate brochure Table 1: aximum filling quantity based on VDI 2035 [mol/m 3 ] 1 < 0.1 0.5 1 1.5 2 2.5 3 >3.0 f H < 1 5 10 15 20 25 30 >30 d H < 0.56 2.8 5.6 8.4 11.2 14.0 16.8 >16.8 e H < 0.71 3.6 7.1 10.7 14.2 17.8 21.3 >21.3 ~mg/l < 10 50.0 100.0 150.0 200.0 250.0 300.0 >300 Conductance 2 < 20 100.0 200.0 300.0 400.0 500.0 600.0 >600 Size of the individual boiler up to 50 kw NO REQUIREENT 20 l/kw 1 Total alkaline earths 2 If the conductance in µs/cm exceeds the value shown in the table, water analysis is required. Subject to alterations, 1.8.2013 31

Examples Hydraulic schematic BDFT020 DHW CW Hoval BioLyt with constant return temperature control, buffer storage tank, Hydraulic schematic BDFT090 DHW C1 Pump, mixer circuit 1 C2 Pump, mixer circuit 2 SLP 5 Boiler circuit pump YK1 Actuator, mixer 1 YK2 Actuator, mixer 2 YKR Actuator, return mixer Y9 Actuator, start load relief (single-wire control) B1 Flow temperature controller (if required) AF Outdoor sensor BRU VF 1 Flow sensor 1 VF 2 Flow sensor 2 SF PF 1 Buffer temperature sensor 1 PF 2 Buffer temperature sensor 2 RS-T CW DHW Room station Cold water Domestic hot water CW Important notes - The hydraulic schematic merely shows the basic principle and does not contain all information necessary for installation. Installation must be carried out according to the conditions on-site, dimensioning and local regulations. - With underfloor heating, a flow temperature controller must be installed. - Shut-off devices to the safety equipment (pressure expansion tank, safety valve, etc.) must be secured against unintentional closing! - Install sacks to prevent single-pipe gravity circulation! 32 Subject to alterations, 1.8.2013

Examples Hydraulic schematic BDFT070 AF 1 TopTronic T VF1 B1 VF2 B1 RS-T RS-T DHW WW T T T T K 1 K 2 P Dies ist ein unerlaubter Weg! Gehen Sie einen Schritt zurück oder löschen Sie dieses Shape! Sie haben die öglichkeit BioLyt ein neues Shape zu nehmen!!! hovhovalhovalhova lhovalhovalhovalho valhovalho ovalhoval lhovalhov Dies ist ein unerlaubter Weg! Gehen Sie einen Schritt T zurück oder löschen Sie dieses Shape! Sie haben die öglichkeit ein neues Shape zu nehmen!!! hovhovalhovalhov alhovalhovalhoval hovalhovalhovalh ovalhovalhovalho valhovalhovalhova < lhovalhovalhovalh = 200 l ovalhovalhovalho valhovalhovalhova lhovalhovalhovalh ovalhovalhovalho valhovalhovalhova lhovalhovalhovalh ovalhovalhovalho valho YK1 YK2 S L P S F Dies ist ein unerlaubter Weg! T Gehen Sie einen Schritt zurück oder löschen Sie dieses Shape! Sie haben die öglichkeit ein neues Shape zu nehmen!!! hovhovalhoval hovalhovalhova lhovalhovalhov alhovalhovalho valhovalhovalh ovalhovalhoval hovalhovalhova lhovalhovalhov alhovalhovalho valhovalhovalh ovalhovalhoval h PP CW KW C1 Pump, mixer circuit 1 C2 Pump, mixer circuit 2 SLP PP Primary pump YK1 Actuator, mixer 1 YK2 Actuator, mixer 2 B1 Flow temperature controller (if required) AF Outdoor sensor VF 1 Flow sensor 1 VF 2 Flow sensor 2 SF RS-T CW DHW Room station Cold water Domestic hot water Subject to alterations, 1.8.2013 33