Differential pressure gauge with electrical contact type Model: P650 series

Similar documents
Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

Ionisation single-tube smoke detector for duct mounting

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

Pressure-Resistant and Explosion-Proof Electric Contact Pressure Gauges and Pressure Switches

TC-5231 Series, TC-5232, & TC-5241 Series

The next generation thermometer from the global leader

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

Temperature, Mechanical

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Magnetic-Inductive Flow Velocity Sensor PIT. Device Description

the next generation thermometer from the global leader

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

Thermostat KPU. Data sheet

When ordering, please state type and code number. Max. Type - Capillary sensor of tube temp. charge length. C m

Sensall Sapphire. Thermo MeasureTech ULTRASONIC POINT LEVEL SYSTEM

CMT MANUAL 6. NMC SENSORS

Ultrasonic Point Level Switches

Sapphire ULTRASONIC POINT LEVEL SYSTEM

Direct reading flowmeters type RM

Powers Controls ET 134 Low Temperature Detection Thermostat

Monitored Pneumatic Valves On Series Ported Manifold

Pressure switch KPU. Data sheet

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

NORTH AMERICAN ADVANCED TECHNOLOGIES, INC.

VAMP 120 & 121. Arc flash detection units. Product picture

Thermometers with capillary tube. Bimetal thermometers. Industrial thermometers. Resistance thermometers

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

Commercial/Industrial Combustion Control Level Three Announcement

TEMPERATURE SENSORS FOR OUTDOOR USAGE 08.12a

FAST RESPONSE TEMPERATURE SENSORS 42.11a

OEM Sensors for HVAC manufacturers Heat recovery Chiller

Thermostat RT. Data sheet

CLEARPOINT Heater. Compressed Air Filter Heater Based on Ohm Resistance

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

UV Flame Supervision System

General Specifications

ENERGY, OIL & GAS. astsensors.com macrosensors.com. Transducer & Transmitter Capabilities. Your sensor business partner...

Topscan G3 Presence detector for automatic doors

Satchwell. DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL FEATURES

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

The Sub-Mini Hermet. OEM Pressure Switches Sub-Mini-Hermet and Omni

Brooks MT3750 Low Flow Armored Flowmeter

Ar-Mite TM Low Flow Armored Flowmeter

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT

Ultrasonic Switches. Features & Benefits

Thermostat Catalog 2004

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Centro-Matic Automated Lubrication Systems System Controls

Room Temperature Sensors

Dissolved Oxygen Measurement liquisys M COM 223 / 253

½ Monitored Pneumatic Valves On Series Ported Manifold

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Dissolved Oxygen Analyzers

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

Operating Instructions. For. Alarm Control Module. Model SSR 500

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

ACS-30-EU-EMDR- 10-MOD

LOW PRESSURE Intrinsically Safe Transducer AST44LP

I ntroduction. Series F61. Liquid Flow Switches. Feature and Benefits

Powers Controls Low Temperature Detection Thermostat

ISIS SAFETY SYSTEM Installation guide

Mobrey MCU900 Series Universal Control Unit

Emergency power automatics MS-2. High resistance to shock, vibrations and transients. All output are 2A relay contacts

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

OPTIBAR DP 7060 Supplementary Instructions

Overload relays. General descriptions. Configuration of the front

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

Glass Tube Variable Area Flowmeter

SELECTION GUIDE SELECTION GUIDE. Pressure, Flow & Liquid Level Products for Aerospace & Military Uses

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Model 144H. Product Data Sheet , Rev DB February Content

PROTECT SRB 200EXi-1A

2500 Automatic Tank Gauge

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

SS-100. Pyrometer. Temperature Range: 800~2400

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

AXICOM Telecom-, Signal and RF Relays. Cradle Relay Accessories and Mounting Nov. 07 Rev. C ECOC: JM10

DMP305X-TST-S monosilicon gauge pressure transmitter

Datasheet - AZM ZRK 24 VAC/DC Solenoid interlock / AZM 170

MagMaster MFE flowmeters feature an innovative multifrequency

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

DOO IK ENG PRODUCT CATALOG DOO IK ENG TEMPERATURE SENSOR PRESSURE SWITCH NON FLOW SWITCH THERMOMETER

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

FIRE STROBE 2000 INSTALLATION INSTRUCTIONS

Series F61. Liquid Flow Switches. Feature and Benefits. T-body and Pipe-insert types available

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

Analog Room Pressure Monitor RPC Series

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

Portable sample gas conditioning PCS.smart+

Transcription:

Differential pressure gauge with electrical contact type Model: P650 series Service intended The P650 series are designed to measure a differential pressure from 25 kpa to 2.0 MPa at static pressure up to 10 MPa, and have electrical contact. A set of two stainless steel bellows mounted on a force balance allows direct reading of the actual differential pressure. These models are designed to control and alarm for a differential pressure. Nominal diameter 160 mm Accuracy ±1.0% of full scale ±1.6% of full scale Scale range (MPa, kpa, bar, mbar) 0 ~ 25 kpa to 0 ~ 0.25 MPa (P651 model) 0 ~ 0.4 MPa to 0 ~ 2.0 MPa (P652 model) Static pressure Max. 10 MPa Working temperature Ambient : -20 ~ 65 C Fluid : Max. 100 C Degree of protection EN60529/IEC529/IP65 Temperature effect Accuracy at temperature above and below the reference temperature (20 ) will be effected by approximately ±0.5% per 10 of full scale Standard features Spec. sheet no. PD06-03 Pressure connection Stainless steel (316SS), Monel and Hastelloy-C Element Bellows Stainless steel (316L SS), Monel and Hastelloy-C Case Stainless steel (304SS) Bezel ring Stainless steel (304SS) Bayonet type Window Polycarbonate Dial White aluminium with black graduations Pointer Black painted aluminium alloy Conduit connection M20 x 1.5 Process connection ¼" NPT(F) ½" NPT(F) at 3-way and 5-way manifold valve Standard accessories Mounting bracket for 2" pipe mounting with silver gray finished steel Certificates Pressure equipment directive (97/23/EC) Annex III Module H Option Remote seal Mounting bracket with 316SS for 2" pipe mounting 3-way manifold valve (316SS, Monel) 5-way manifold valve (316SS, Monel) 249

Main order 1. Base model P651 Electrical contact type pressure gauge (0 ~ 25 kpa to 0 ~ 0.25 MPa) P652 Electrical contact type pressure gauge (0 ~ 0.4 MPa to 0 ~ 2.0 MPa) Ordering information 10. Option 0 None 1 Manifold valve 8 ½" or ¾" NPT(F) conduit connection 2. Nominal diameter (mm) 6 160 3. Type of mounting D Bottom connection, mounting bracket for 2" pipe 4. Contact function X Refer to contact function table 5. Process connection C E ¼" NPT(F) ½" NPT(F) (only at 3-way and 5-way manifold valve) 6. Mounting bracket D E F W N Standard bracket 304SS mounting bracket 316SS mounting bracket Wall mounting bracket (316SS) None 7. Unit H I J S bar MPa kpa mbar 8. Range 041 0 ~ 0.1 MPa 133 0 ~ 0.16 MPa 134 0 ~ 0.25 MPa 044 0 ~ 0.4 MPa 045 0 ~ 0.6 MPa 047 0 ~ 1 MPa 143 0 ~ 1.6 MPa 051 0 ~ 2.0 MPa 118 0 ~ 25 kpa 121 0 ~ 40 kpa 125 0 ~ 60 kpa 9. Dial color 3 2 colors 1 2 3 4 5 6 7 8 P651 6 D 4 E D I 047 9 10 3 1 Sample ordering code 250

P65X : Type of mounting 251

Snap - action contacts General Electromechanical limit switches in pointer type measuring instruments are auxiliary current switches which open or close electrical circuits at set limit values by means of a contact arm which is moved by the actual value pointer. The snap action contact is a mechanical contact for switching capacities up to 30 W 50 VA max. Contact making will be delayed and or advanced in relation to the movement of the actual value pointer. To closed the circuit, the contact pin of the movable contact arm is attracted in a jump by the permanent magnet fastened to the supporting arm shortly before the set value has been reached. Due to the retention force of the magnet, snap action contacts are more resistant against shock and vibration. The switching safety is increased by the increased contact pressure. When the circuit is opened, the magnet keeps the contact arm in its place until the restoring force of the measuring element exceeds the magnetic force, and the contact opens in a jump. Specifications Maximum contact rating with non-inductive (ohmic) load Maximum voltage Make ratings Current ratings Break ratings Continuos load Maximum load Material of contact points Ambient operating temperature Max. no. of contacts Voltage test Electrical contacts type pressure gauge model P650 series Dry gauges Liquid filled gauges 250 V 250 V 0.6 A 0.6 A 30 W 50 VA 20 W 20 VA Silver-nickel alloy (80% Ag / 20%Ni / 10μm ) gold-plated -20 C...+70 C 2 Circuit / protective earth conductor - 2,000 vac 1 minute Circuit /circuit - 2,000 vac 1 minute Recommended contact ratings with ohmic and inductive load Voltage (DIN IEC 38) DC / AC V 220 / 230 110 / 110 48 / 48 24 / 24 Electrical contacts type pressure gauge model P650 series Dry gauges Liquid filled gauges Ohmic load Inductive load Ohmic load Inductive load DC AC DC AC cosø > 0.7 cosø > 0.7 ma ma ma ma ma ma 100 120 65 65 90 40 200 300 400 In order to ensure a high switching reliability of the contacts the switching voltage should not be below 24 V, also taking environmental influences in the long term into account. 240 450 600 130 200 250 130 190 250 180 330 450 85 130 150 252

Contact function table Code Wiring scheme Contact function st 2 nd contact 1 contact Wiebrock code no. Remark Contact make when pointer reachse (Normal open - NO) high alarm system Contact break when pointer reachse (Normal close - NC) low alarm system 1 st and 2 nd contact make high and hihigh alarm system 1 st contact make 2 nd contact break failsafe high and low alarm system 1 st contact break 2 nd contact make high and low alarm system 1 st and 2 nd contact break low and lolow alarm system 253

Terminal block arrangement 1. High alarm (S/M-1) Normal open 2. High and low alarm (S/M-21) Low alarm Normal close High alarm Normal open 3. Low alarm (S/M-2) Normal close 4. Two high alarm (S/M-11) No.1 High alarm Normal open No.2 High alarm Normal open 5. Two low alarm (S/M-22) No.2 Low alarm Normal close No.1 Low alarm Normal close 6. Failsafe high and low alarm (S/M-12) High alarm Normal close Low alarm Normal open 254