CALEFFI. Automatic flow regulators GB. AUTOFLOW APPLICATION No AIR CONDITIONING MACHINE

Similar documents
APPLICATION BROCHURE Chillers and Heat Pumps Hydraulics Manual. Suggestions for the hydraulic integration of chillers and heat pumps

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

Blue Box Epsilon Echos +

Be sustainable while protecting your business

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

EN aquatech.piovan.com

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

ASTRALPOOL HEAT PUMP CATALOGUE

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Inverter Hot Water Heat Pumps

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

H4T R410A. refrigerant

A Technical Introduction to Cool Thermal Energy Storage Commercial Applications

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Air cooled industrial chillers

ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

1

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

Refrigeration dryers with Energy Saving Impulse Technology and Thermal Mass 0,3-27,0 m³/min Purifying your compressed air, increasing your efficiency.

NRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER

HT V2 HT Split

Components for solar heating systems

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C

Starting current with soft starter Fuse protection. Connection heating Seal of approval MCS (valid until)

and sanitary hot water Catalogue 2009

Customers. The core of our innovation. Feeding&Conveying Drying Dosing Temperature Control Refrigeration. Granulation

Aqua 1 plus Air-water heat pumps for domestic hot water production

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

Low Temperature Radiator GB 01. Heating & Plumbing. Ideas to install

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

User Manual. Vanvex Optima 180 Domestic Hot Water. Version

Installation, operation and care Wall-mounted electric boiler MP THL nr. - rev 02

CALEFFI. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit. series /04 GB.


ELFOEnergy Duct Inverter

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

ECOFOREST GEOTERMIA. ecogeo. Ground/Air Source Heat Pumps.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

Starting current with soft starter Fuse protection

Process glycol chillers

ERGON EQUIPMENT SA PRESENTATION

OPERA MORE. Use. Range. Drycoolers Air-cooled condensers. for LESS. Capacity: up to 1100 kw. Water misting. Free cooling

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

DEi COMPRESSED AIR & GAS TREATMENT. Purifying your compressed air, increasing your efficiency.

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Data sheet SI 24TE. Brine-to-water heat pump with two performance levels

GHE. Dehumidifiers for radiant cooling systems with heat recovery. Display

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

ASTRALPOOL HEAT PUMP CATALOGUE

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

> > > Heat pump systems. Water Chillers. Dehumidifiers

50A KP 70A KP 90A KP 120A KP 150A KP 210A

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

Rapid. Suspended Warm Air Heater. Caring for the environment!

The ultimate in air handling units: directly and indirectly fired

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

heat interface units A BOILER WITHOUT A FLAME

Modular Air-cooled Chillers

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE

Refrigeration Compressed Air Dryer Boreas Variopulse

The ultimate in air handling units: directly and indirectly fired

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

solar thermic systems

Energy-Saving Industrial Water Chillers

ARS. 1

Industrial cooling systems LT

v SELECTION GUIDELINES

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

Psychrologix Controller W/ DHC

Metering systems 0548EN April 2014

Technical description. Atec.

The ultimate in air handling units: directly and indirectly fired

SEISCO APPLICATIONS & DIAGRAMS

CHILLER. Modelli CWS BASIC CWS AQUACONTROL INSTALLATION MANUAL USAGE AND SCHEMATICS

Transcription:

Automatic flow regulators GB AUTOFLOW APPLICATION No. Air-conditioning machine for aircraft on the ground This system is designed for air-conditioning of aircrafts when they are on the ground, connected to the mobile jetways at the airport terminal satellite. An air-conditioning machine is placed below each jetway and, in the summer cooling load, will condition the air to C and blow it through flexible hoses into the inside of the aircraft. The total cooling power installed in the system for the machines is kw. In the case of a winter heat load, however, a simple electrical heating battery is used. Inside each machine is a first stage heat exchanger set supplied with chilled water at 7 C originating from the refrigeration unit and controlled by a -way modulating regulating valve. A condenser, connected in series to the same circuit gets rid of the heat extracted by the second stage direct expansion coil. The regulator controls the valve taking into account the air delivery temperature, the cabin temperature and the outside temperature. The chilled water circuit is also used here for air-conditioning inside the airport satellite. For the hydraulic balance of the circuit, an Autoflow automatic flow regulator is positioned on the connection to each coil inside the machine. This means that the flow rate of chilled water supplied to each coil is limited to the nominal design value when the total load of the system varies. In addition, the flow rate in the circuit is kept constant when the position of the -way valve is changed. This guarantees the optimum service from the air-conditioning unit and the central chillers. AUTOFLOWs installed: x series with connections: Flow rate: m /h kpa. AIR CONDITIONING MACHINE AIR CONDITIONING MACHINE JETWAY ST STAGE COIL ND STAGE COIL WATER CONDENSER -WAY REGULATING VALVE 7 AUTOFLOW FAN 9 COMPRESSORS ST Stage ND Stage FLEXIBLE HOSE 7 FROM/TO CENTRAL CHILLED WATER PLANT AIR DELIVERY 9 OUTSIDE AIR HYDRAULIC CIRCUIT Fiumicino Airport - New Western Satellite, Rome, Italy KLIMAT S.p.A., Sesto Ulteriano, Milan, Italy

AUTOFLOW APP Food refrigeration system This system is designed for the refrigeration of counters and cabinets for the preservation of food products. It is installed in a hypermarket in a shopping centre with a covered area of about m. The cooling power installed in the refrigeration system is about kw. All kinds of food on display or stored in the supermarket, such as vegetables, cold meats, and deep-frozen foods, have specific thermal conservation requirements. To control the temperature, each counter and cabinet contains a fanned heat transfer coil. A user thermostat controls the two-way on/off solenoid valve on the coil itself. This system uses innovative ecological technology, making it possible to reduce emissions of chlorofluorocarbons, which are harmful to the atmosphere. The coils are, in fact, supplied with an appropriate anti-freeze fluid produced in a central refrigeration plant at - C and - C and distributed to the user cabinets through pumps; this system replaces the traditional method of supplying the coils directly with coolant gas. The central refrigeration plant consists of units in parallel for temperature NT (- C) and units in parallel for temperature LT (- C). The fluid distribution pump are variable speed with constant p regulation to reduce pumping costs as the controlled flow rate of the two-way valves is reducing. The hydraulic supply circuits for the user units, both NT and LT, are of the direct return type and are dinamically balanced using the Autoflow automatic flow stabiliser installed in the circuit returning from each coil. When the open/closed condition of the valve changes, the flow of fluid is continuously restricted to the nominal value in the circuits which remain open. The system can thus operate in optimum conditions when the heat load varies, thanks to the better overall operation of the coils and the cooling units. AUTOFLOWs installed: x series from / to / conn.: Flow rate:, m /h kpa. REFRIGERATION SYSTEM COUNTER NT CENTRAL REFRIGERATION PLANT NT - M CABINET NT REFRIGERATION UNIT REGULATING VALVE HEAT TRASFER COIL AUTOFLOW BY-PASS VALVE

ICATION No. P Inverter P Inverter C CENTRAL REFRIGERATION PLANT LT - C M COUNTER LT CABINET LT M M COUNTER NT COUNTER LT

AUTOFLOW APP Air-conditioning system with underfloor heating and primary air UNDERFLOOR HEATING SYSTEM This system is designed for air-conditioning a building complex housing an art gallery and an archaeological museum. The buildings are on three floors; the air-conditioned area is approx. m. The system has a total installed thermal output of approx. kw and refrigeration power of kw. For this type of structure, a mixed water/air system was selected, with, according to the zones involved, underfloor radiant panels and primary air or fan-coil units and primary air. In addition to heating, the panel system is used here for cooling in the summer season. The important control of the relative humidity and renewal air treatment is effected in this case by central treatment of the primary air, which is then distributed through ducts. A centralised supervision and control system allows that each zone can be managed fully and independently, allowing adjustment of the relative humidity and temperature parameters at will. The distribution of the thermal carrier fluid is effected by means of direct return circuits to which are connected, according to zone, fan coil units or alternatively, underfloor heating zone manifols; the latter have two-way on/off regulating valves and individual panel shut-off and calibration valves. The circuits operate with variable flow rate and are provided with pump units inverters to vary the speed with the load. To balance the hydraulic circuits dynamically, an Autoflow automatic flow stabiliser is installed for each panel manifold and for each fan-coil unit. This means that the balancing of the circuits is always guaranteed, even when the open/closed position of the regulating valves varies. To the advantages arising from the use of underfloor heating panels are added those arising from the use of the Autoflow and the variable speed pumps, giving optimuml results in terms of comfort and energy saving. AUTOFLOWs installed: 9 x series, with / connections: Flow rate: m /h kpa. 7 S. Giulia Museum Complex, Brescia (BS), Italy Engineer Mario Doninelli, Brescia (BS), Italy DISTRICT HEATING

C C ICATION No. 7 OTHER ZONE MANIFOLDS B A A MANIFOLD B AUTOFLOW C FILTER D -WAY VALVE C D OTHER PANEL MANIFOLDS S S Inverter Inverter AIR HANDLING UNIT MANIFOLD BOX FAN-COIL UNIT AUTOFLOW CHILLER F F BUFFER TANK 7 DISTRICT HEATING EXCHANGER

AUTOFLOW APPLICATION No. Solar panel system This solar panel system was installed on the roof of a swimming pool at the end of the 9s. Made with flat collectors, with an area of m and a thermal output of approx. kw, after reconstruction work, it can meet all the heat requirements for the supply of domestic hot water and, in the most favourable periods, it also contributes to topping up the heating of the children s pool during summer operation. A traditional central heating system, with heat generators using gas oil, supplements the solar panel system or replaces it, in periods when there is insufficient sunshine and during winter operation. The system, which was originally a closed circuit, has been changed into an open and draining system, which permits the solar collectors and all the connecting pipework to discharge completely whenever the electric supply pumps shut down, storing all the thermal carrier fluid in the stainless steel drainage tank in the central heating system, which then reaches the maximum level. A system of plate heat exchangers, supported by a special electronic regulator, controls the correct operation of the solar panel system and stores the heat energy produced in it, directing it to the domestic hot water storage tank, or to the circuit for heating the children s pool, as required. The open and draining system has other additional advantages: - the possibility of using fresh water as the thermal carrier fluid, instead of mixed with glycol solution, which, as is well-known, has a much lower specific heat with a consequently reduced capacity to absorb thermal energy. This means that, with the same flow rate, a lower quantity of heat is carried from the solar collectors to the points of usage; - there are no freezing problems when the system is empty in the winter period or overheating problems when on standby during the summer period; - corrosion of the equipment, due to glycol solution, is avoided. The system, originally, had solar collectors connected in series, with serious problems of dynamic balancing, so that its output could never fully meet requirements. For this reason, when the distribution pipework, which was corroded in several places, was being replaced, the whole thing was converted into an open and draining system, and at the same time an Autoflow automatic flow stabiliser was installed in the return pipework of each individual solar collector, correctly dimensioned, and guaranteeing each individual collector the rated design flow, hence improving the heat output performance to the maximum. AUTOFLOWs installed: x series with / connections: Flow rate:, m /h kpa. SOLAR PANEL SYSTEM SOLAR PANEL AUTOFLOW DOMESTIC HOT WATER DOMESTIC HOT WATER STORAGE TANK DRAINAGE TANK HEAT EXCHANGER DOMESTIC COLD WATER TO THE POOL Public Swimming Pool, Spiazzo Rendena (TN), Italy Termotecnica & Impianti p.i. Donato Candioli, Storo (TN), Italy

AUTOFLOW APPLICATION No. 9 Cooling system for operating machinery This system is designed for cooling operating machines used in a printing inks production unit. These machines consist of two functional parts, one used for grinding the material, and the other, known as the drum, processes the ink as the finished product. Each of the two component parts of the machine must be cooled to keep the temperature at levels which will guarantee that the finished product has the required chemical and physical characteristics. A chilled water closed circuit supplies the heat exchangers located inside the machine itself. In addition to requiring to be supplied with the correct flow rate of fluid, these exchangers have limitations in terms of maximum pressure; specific pressure limits must not be exceeded inside each exchanger, or they will suffer structural damage. In order to meet both these requirements, one pressure reducer designed to limit the pressure to the required value, and one Autoflow flow stabiliser, which keeps the flow constant at the nominal value are installed in series at the connection to each exchanger. The system operates with a variable flow rate, as the circuits supplying the grinding machines or the drums can be shut-off according to production requirements. A variable speed pumping unit provides the head according to the system loading. Thanks to the presence of the Autoflow, the flow rate in the open circuits is always restricted to the rated flow rate, regardless of the number of circuits connected, hence guaranteeing that each machine is operating under optimum conditions. AUTOFLOWs installed: x series with / connections: Flow rate:,, m /h kpa. COOLING SYSTEM FOR MACHINERY INVERTER CHILLER HYDRAULIC COMPENSATOR BUFFER TANK GRINDING MACHINE PREPARATION DRUM PRESSURE REDUCER 7 AUTOFLOW TO OTHER MACHINES 7 INSTALLATION: FISAT Production Unit, Collegno (TO), Italy S.T.A. Studio Termotecnico Associato Revelli & Basso, Turin (TO), Italy Impresa D Ambrosio, Collegno (TO), Italy

7 9 7 9 9 7 TERMIE SISTEMI CALORE CONTECA kwh Modulo 7 Caratteristiche VAC Hz W elettriche Modalità: G Pot. Imp. Pile x, V G.E.O. IDB Cost.: Monoconteca: TAMB. MAX = C TMAX = C Nome utente Classe protezione: IP AUTOFLOW APPLICATION No. Air conditioning system This system is designed for air-conditioning a multi-purpose centre, partly used for offices and partly for shops and small businesses. The building is on floors, with an area of. m and a served volume of. m. The system has heating output of approx.. kw and cooling power of. kw. For air-conditioning the various zones which the building is divided into, according to the individual user requirements, solutions have been selected with fan-coil units and/or zonal air treatment units. Each zone connection, either to the manifold assemblies in the case of fan-coil units or to the air conditioning coils, is provided with a three-way regulating valve for controlling the ambient heating load, a direct heat meter for measuring the heat consumption for heating and domestic hot water, and Autoflow automatic flow stabiliser for the dynamic balancing of the hydraulic circuit. The system operates at constant flow rate, with flow rate limitation to each user, according to the nominal design conditions, guaranteed by Autoflow. A Conteca centralised heat consumption management system ensures the correct breakdown of the costs between the various users. The overall operation of the plant, therefore, under these optimum conditions, gives the best results in terms of comfort and energy savings. AUTOFLOWs installed: 7 x series with to connections: Flow rate:,9 9 m /h kpa. AIR CONDITIONING SYSTEM OUTSIDE AIR COMMERCIAL OUTLET FROM/TO CENTRAL HEATING SYSTEM COMMERCIAL OUTLET AMBIENT AIR DISTRIBUTION AIR OUTLET 7 AIR CONDITIONING UNIT FAN-COIL UNIT ZONE VALVE HEAT METER AUTOFLOW SENSORS 7 CONTECA MANAGEMENT UNIT DOMESTIC HOT WATER METER Centro Polifunzionale Edilanciani, Corridonia (MC), Italy Studio Tecnico Ing. Luigi Domenella, Civitanova Marche (MC), Italy S.P.A. FONTANETO D'AGOGNA (NO) S.S.9 TEL. 9 R.A. FAX http://www.caleffi.com e-mail: info@caleffi.it