High-Speed Voice and Data Link Access Multiplexer

Similar documents
Dry Contact Probe DCP (#30008)

USER MANUAL FOR OPERATING SYSTEM

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

600 Range Dialer Installation Manual. Version 1.0

QS941A Controller User Interface

EX41922-T Hardened Unmanaged 2-port 10/100/1000BASE PoE + 2-port 100/1000 SFP Ethernet Switch. User s Guide

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

UNC100 Integra Manual

EX41922 Hardened Unmanaged 2-port 10/100/1000BASE + 2-port 100/1000 SFP Ethernet Switch. User s Guide

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

LORAIN CIP 4890/48120 DC Power System

Added password for IP setup page : Password must be in IP format!

MODEL B2 INSTALLATION MANUAL

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9

D-TECT 2 IP. GJD230 IP Motion Detector

Manage Alarms. Before You Begin CHAPTER

Veritas Appliance Hardware Service Procedure

DS3/STS-1 Protected Repeater System User Manual

D-TECT 3 IP. GJD260 IP Motion Detector

Trident User s Manual

Metasys System Extended Architecture Fire System Integration Using the IFC BACnet Gateway

Common Control Cards

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

4100U City and Relay Cards Installation Instructions

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

GLOBAL. InstallatIon & operation manual

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

P2267 NETWORK INTERFACE

Proliphix Thermostat Installation Guide. Release 2.0

LORAIN CSP DC Power System

IndigoVision Alarm Panel. User Guide

LUMA-NET 804CP / 808CP REMOTE CONTROL PANEL

Simplex Panel Interface Guide

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

Mobeye CM2410 GSM fire alarm communicator

Laptop / PC Programming Manual

RMS/RPX Reader. User Manual

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

Manage Alarms. Before You Begin CHAPTER

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Model T B Intraoffice T1 Repeater User Manual

RangerNET Network Ready Constant Monitor Model CM2815

Total Access 1500 SCU Installation and Maintenance

INSTALLATION INSTRUCTIONS

SAFETY INFORMATION AND WARNINGS

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

CARETAKER PLUS: MOST FREQUESNTLY ASKED QUESTIONS. Which sensor programming group should I use for a wireless freeze sensor?

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.

Pioneer-R16 Gas Monitor Operator s Manual

Operations Manual TS400. Test Station for G450/G460 Gas Detector

CBI-064. User Manual. Caddx to KNX-BUS Interface

USER MANUAL Mobeye ThermoGuard CM2200

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

LMS-188-4P-BMS 4 POINT DIGITAL MONITOR/ALARM WITH PROTOCOL CONVERTER OPERATING INSTRUCTIONS

GDC 087R Issue 1 - May Installation and Operation UAS Network/Dropside Interface Unit Model NIU/DIU 7624.

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Galaxy Pulsar Plus Digital Battery Plant Controller

ENTOUCH ONE USER GUIDE

Operating instructions V-ZUG-Home

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

TLS-300 UST Monitoring and Leak Detection System

Long Range Radio Alarm Transmitter

rvm4c Installation Guide Remote Video Module

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect

Alarm Monitoring and Management

RCS Residential Control Systems Inc.

FIRERAY 5000 range USER GUIDE

Alarm Monitoring and Management

Fiber Optical Multiplexer

Alarm Panel [ PRELIMINARY HARDWARE MANUAL ] USER MANUAL. v1.0a. May 7, 2008 D-OC-UM

Advisor Advanced Mobile Application User Manual

Millennium Xtra. Millennium ATMA setup and configuration guide. May Millennium Group, Inc.

User Guide. Sky Muster service. Includes information about your nbn supplied equipment

Oakton TEMP 9500 Advanced Multiparameter Controller

CSP-204 CSP-208 CSP-104 CSP-108

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power

IP & SMS Alarm Communicator

Operations Manual TS400. Test Station for G450/G460 Gas Detector

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

Veritas Appliance Hardware Service Procedure

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

INSTALLATION INSTRUCTIONS

ACCURATE ELECTRONICS INC

OPTICAL TURNSTILE SYSTEM

Med Touch Master Alarm

GDC 087R Issue 2 - May Installation and Operation UAS Shelf/Enclosure. General DataComm

MODEL DZSP/ SZSP-1440 AIRCELL

WebAlert WA500 Series Process Monitor Instruction Manual

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -

KitchenAid Food Stream Solutions Classic and Integrated Series

Transcription:

Telecommunications Group Section HVD-381-202 Equipment Issue 2 First Printing, August 2003 High-Speed Voice and Data Link Access Multiplexer CONTENTS PAGE Part 1. GENERAL............................................................................. 2 Part 2. INSPECTION........................................................................... 2 Part 3. APPLICATION GUIDELINES............................................................. 3 Part 4. INSTALLATION......................................................................... 4 Part 5. PROVISIONING........................................................................ 6 Part 6. ALARMS AND LEDS................................................................... 11 Part 7. TROUBLESHOOTING.................................................................. 12 Part 8. TECHNICAL ASSISTANCE............................................................. 13 Part 9. WARRANTY & CUSTOMER SERVICE................................................... 13 Part 10. SPECIFICATIONS..................................................................... 14... Figure 1. High-Speed Voice and Data Link (HVDL) Access Multiplexer (AMUX) 2003 Charles Industries Ltd.. High Speed Voice and Data Line is a trademark of Charles Industries, Ltd. All rights reserved. Printed in United States of America. The availability of features and technical specifications herein subject to change without notice. Page 1 of 17

Section HVD-381-202 1. GENERAL 1.1 Document Purpose This document provides a general description, application and installation information for the High-Speed Voice and Data Link (HVDL) Access Multiplexer (AMUX). This document covers model number 91-HVDL381. 1.2 Document Status Issue 2 includes network management functionality that enables the user to monitor or change settings of the HVDL and Access Multiplexer remotely. 1.3 Equipment Purpose and Description The HVDL Access Multiplexer collects 10BaseT Ethernet data from the HVDL central office terminal (COT) line units in its shelf and sends it to the 100BaseTx Ethernet connection at the uplink port. It also provides alarm functions for each COT line unit in the shelf. The access multiplexer eliminates the need for individual data connections from each COT, and eliminates the need for a separate alarm unit in the shelf. The unit is designed to be plug and play with a minimum of connections to the shelf Monitoring of the COT settings (such as data speed) may be done through the access multiplexer. The access multiplexer is in-system software-upgradable. The functional management command set for the access multiplexer is documented in the Access Multiplexer Software User s Guide. 1.4 Equipment Mounting Mounts in slots 15 and 16 of a 19-inch HVDL or DDL shelf or slots 18 and 19 of a 23-inch HVDL or DDL shelf. 1.5 Equipment Features The HVDL Access Multiplexer provides the following features: Aggregates data from up to 17 HVDL COTs simultaneously. May be provisioned from the front panel. Eliminates the need for individual data connections from the network to each COT. Monitors all HVDL COTs in its shelf for alarm conditions. Alarm functions backward-compatible with 300-series shelves. Provides LEDs on the front panel to indicate MAJOR and MINOR alarms. Expansion port allows cascading of multiple HVDL Access Multiplexers. User-provisioned port-to-port blocking provides data security. n-volatile storage of configuration settings (if the Access Multiplexer is restarted, its configuration settings are automatically restored). 1.6 Equipment Cables 100 BaseTX shelf-to-shelf cable.

2. INSPECTION 2.1 Inspect for Damages Inspect the equipment thoroughly upon delivery. If the equipment has been damaged in transit, immediately report the extent of damage to the transportation company. 2.2 Equipment Identification Charles Industries equipment is identified by a model and issue number imprinted on the front panel or located elsewhere on the equipment. Each time a major engineering design change is made on the equipment, the issue number is advanced by 1 and imprinted on subsequent units manufactured. Therefore, be sure to include both the model number and its issue number when making inquiries about the equipment. 2.3 Static Concerns Each module is shipped in static-protective packaging to prevent electrostatic charges from damaging static-sensitive devices. Use approved static-preventive measures, such as static-conductive wrist straps and a static-dissipative mat, when handling modules outside of their protective packaging. A module intended for future use should be tested as soon as possible and returned to its original protective packaging for storage. STATIC-SENSITIVE Use approved static preventive measures (such as a static-conductive wrist strap and a static-dissipative mat) at all times whenever touching units outside of their original, shipped static-protective packaging. Do not ship or store units near strong electrostatic, electromagnetic, or magnetic fields. Use static-protective packaging for shipping or storage. 3. APPLICATION GUIDELINES A typical application of the HVDL Access Multiplexer consists of a 300-mechanics shelf filled with HVDL3.1 COT line units. The COT line units are connected to end-user premises equipment, providing voice and data service. The access multiplexer allows the data from all COTs in a shelf to be collected and accessed at a single card. The collected data is sent to a network switch or router through the uplink port. Multiple access multiplexers can be daisy-chained by connecting them through their expansion ports. Figure 2 illustrates a typical application.

Section HVD-381-202 Data Network Switch or Router Crossconnected CAT 5 cable Straight connect CAT 5 cable (included) COT COT COT COT COT COT COT COT COT COT COT COT ACCESS MULTIPLEXER COT COT COT COT COT COT COT COT COT COT COT COT ACCESS MULTIPLEXER Figure 2. Typical Access Multiplexer Application 4. INSTALLATION 4.1 Mounting and Turn-Up Mount the Access Multiplexer in slots 15 and 16 of a 19-inch HVDL or DDL shelf or slots 18 and 19 of a 23-inch HVDL or DDL shelf. Use the following steps to install the Access Multiplexer: CAUTION Installation and removal of units should be done with care. Do not force a unit into place. If excessive resistance is encountered during installation, remove the unit and check the card guide and connector to verify proper alignment and the absence of foreign material. WARNING A fan tray (92-FANHVDL for 19-inch shelves or 92-FANHVDL23 for 23-inch shelves) must be installed and powered prior to installing the Access Multiplexer.

Step Action 1. Disconnect any data connection on the front of the HVDL COTs. 2. Align the unit with the appropriate card-guided slot in the shelf. 3. Slide the unit into the slot until it is seated in the backplane. Once the card is inserted in the correct slot, the power indicator on the front panel lights and the STATUS display shows the following messages, in order: INIT RAM ROM FPGA DMA IRQ CACH BUSI SW 1 SW 2 PASS HVDL ACCS MUX AMUX The green NEAR LED on the HVDL COT 10BaseT connectors should light on all COTs. AMUX is displayed during normal operation. During initialization, LEDs may blink on and off, but ignore these until AMUX remains lit. 4.2 Installer Connections Step Action 1. Connect a CAT5 cross cable from the front panel of the Access Multiplexer uplink connector to the network Ethernet switch/router. The green LINK LED on the Access Multiplexer should light. 2. If multiple access multiplexers are to be daisy-chained, connect the front panel uplink port to the expansion (EXP) port of the next HVDL access multiplexer located in the HVDL shelf above (see Figure 2) using a straight-connected CAT5 cable with RJ45 connectors. WARNING Do not connect the access multiplexer in one shelf to COTs in another shelf. 4.3 ALARM and MISC Connections These connections are made to the 20-pin wire-wrap field located at the rear of the DDL30X shelf, as shown in Figure 3. Alarm wiring can be made with 22 or 24 AWG wire. Figure 4 shows the ALARM and MISC connections to the DDL30X or HVDL31X.

Section HVD-381-202 Issue 1 DDL305 Shelf HVDL381 Access Multiplexer* MINOR VIS MINOR AUD MAJOR VIS CCK MNV MNA MJV Multiple to all shelves in same rack Top of rack Alarm & Misc Block To Office Composite Clock To Office Alarm GRD MAJOR AUD MJA E2 MINOR E2 MAJOR SID E2MN E2MJ SID To Remote Alarm Telemetry System (If required) * Position 15 & 16 of the shelf. RACO DETECTOR RACO Figure 3. TB1 Pinouts on Issue 1 DDL305 Shelf HVDL311 or HVDL315 shelf, or issue 2 DDL301 or DDL305 shelf HVDL381 Access Multiplexer P6 P5 Multiple to all shelves in same rack Top of rack Alarm & Misc Block * Position 18&19 of DDL301 or HVDL311, or positions 15&16 of DDL305 or HVDL315 RACO DETECTOR SID E2 MAJOR RACO SID E2MJ To Remote Alarm Telemetry System (If required) E2 MINOR E2MN MAJOR AUD MJA MAJOR VIS MINOR AUD MJV MNA To Office Alarm Grid MINOR VIS B A MNV CCK To Office Composite Clock Alarm contacts shown in powered non-alarm condition. If an alarm occurs or power is removed, the contacts will close. Figure 4. P5 and P6 Pinouts on Issue 2 DDL305 or DDL301 Shelves or the HVDL311 or HVDL315 Shelves

5. PROVISIONING See Figure 5 for the provisioning procedure. When the display reads... AMUX AVER MAC SRL# PLCK Indicates... The Access Multiplexer has passed all self tests and is ready for normal operation. Access Multiplexer version. Use this menu to look at the unit s circuit board number and software revisions. Media Access Control (MAC) Address. Use to view the Access Multiplexer s MAC address. The MAC address is displayed as 12 characters. Serial Number. Use to look at the AMUX s unique 10-digit serial number. Port Lock. Use to enable/disable port security. te: This setting is stored in non-volatile memory. If the Access Multiplexer is restarted for any reason, this setting will be automatically restored. NTWK When PLCK is enabled (ON), AMUX Ethernet ports are locked. This prevents an HVDL user from gaining unauthorized access to another HVDL user s system. This is the factory default When PLCK is disabled (OFF), AMUX Ethernet ports are unlocked. Data can go directly from one HVDL system to another HVDL system in the same shelf or in another shelf in the same daisy chain. CAUTION When PLCK is disabled (OFF), the AMUX allows any HVDL user to see any other HVDL user in the same shelf or in a different shelf. Security between AMUX ports must then be implemented by using firewalls, disabling file sharing at the user s computer(s), or other methods as required. Network Settings. Use to view the access multiplexer s IP address, subnet mask, and gateway address. Also used to reset the network settings to the factory default values. Once the network settings are changed the card must be reset in order for the changes to take effect. The card can be reset in one of two ways. One, by removing and reinserting the card in the shelf. Two, by using the Management Command Set for resetting the card. The factory defualt network settings are: IP Address = 192.168.0.2 Subnet Mask = 255.255.255.0 Gateway Address = 192.168.0.1

Section HVD-381-202 Display reads AMUX SELECT Figure 5. Optioning, page 1

Figure 5. Optioning, page 2

Section HVD-381-202 Displays NTWK network settings or reset them to factory defaults? Yes SELECT ADVANCE Displays PREV provisioning categories again? Yes ADVANCE SELECT DONE Display reads AMUX Figure 5. Optioning, page 3

Figure 5. Optioning, page 4

Section HVD-381-202 Displays IP Continue pressing ADVANCE to move through the 4 numbers in the IP adress the IP address? Yes SELECT ADVANCE this again? SELECT ADVANCE Displays SUBM Continue pressing ADVANCE to move through the 4 numbers in the subnet mask the subnet mask? Yes SELECT ADVANCE this again? SELECT ADVANCE Displays GTWY the gateway address? Yes SELECT Continue pressing ADVANCE to move through the 4 numbers in the gateway address ADVANCE this again? SELECT ADVANCE Displays RST? want to reset the network settings to factory defaults? Yes SELECT really want to do this? Yes SELECT ADVANCE Figure 6. Optioning, page 5

Displays PREV network settings again? Yes ADVANCE SELECT Figure 7. Optioning, page 6 6. ALARMS AND LEDS 6.1 Alarms The access multiplexer performs the same functions as a DDL381 alarm card. 6.1.1. Minor Alarms When any one or more (but not all) of the COT LUs or the access multiplexer is in an alarm state, a MINOR alarm is reported. The front panel MN LED is lit, and the MNV, MNA, E2MN and SID contacts are closed. 6.1.2. Major Alarms When all of the COTs in a fully-populated shelf are in an alarm state, a MAJOR alarm is reported. The front panel MAJ LED is lit, and the MJV, MJA, E2MJ and SID contacts are closed. 6.1.3. Audible Alarm Cut-off During an alarm, the audible alarm can be turned off by pressing the ACO button. This only turns off the audible and remote notification of the alarm the alarm itself is NOT cleared. ing the ACO button opens the MNA, E2MN, MJA and E2MJ relay contacts for current alarms. MNV, MJV and SID relay contacts remain unchanged. Subsequent alarms will close the audible and remote relay contacts, restarting the audible and remote alarm notification. Table 1. Alarm Summary MINOR Alarms 1 to 13 COT alarms detected by the Access Multiplexer in a 19-inch shelf 1 to 16 COT alarms are detected by the Access Multiplexer in a 23-inch shelf Access multiplexer failure 100BaseTx uplink failure ACO pushbutton or remote ACO detected after MINOR alarm System Response The front panel MN LED is lit, and the MNV, MNA, E2MN and SID contacts are closed. ACO LED and MN LED are lit; MNV and SID contacts are closed.

Section HVD-381-202 MAJOR Alarms 14 COT alarms detected by the Access Multiplexer in a 19-inch shelf 17 COT alarms detected by the Access Multiplexer in a 23-inch shelf ACO pushbutton or remote ACO detected after MAJOR alarm System Response The front panel MAJ LED is lit, and the MJV, MJA, E2MJ and SID contacts are closed. ACO LED and MJ LED are lit; MJV and SID contacts are closed. 6.2 LEDs Table 2 describes the states of the AMUX LEDs. Table 2. LED States LED Color Indicates... LINK Green ON: 100BaseTx Ethernet uplink connection established OFF: 100BaseTx Ethernet uplink connection not established or down RCV Green FLASHING: Data traffic is being received from uplink connection OFF: Data traffic is not being received from uplink connection XMT Green FLASHING: Data traffic is being transmitted to the uplink connection OFF: Data traffic is not being transmitted to the uplink connection DATA ALARM Red FLASHING: Unit startup ON: Data aggregation function is not working OFF: rmal function (data aggregation operating) PWR Green ON: AMUX receiving power OFF: AMUX not receiving power MAJ Red ON: All COT units in a fully-populated shelf are in an alarm state OFF: rmal operation (no COT units in alarm, or not all COT units in alarm in a fully-populated shelf) MN Amber ON: One or more units in the shelf are in an alarm state. OFF: rmal operation (no minor alarms) ACO Amber ON: Audible alarm cut-off is active. OFF: Audible alarm cut-off is inactive. 7. TROUBLESHOOTING Problem Possible Causes Solutions PWR LED does There is no power to the unit. Check the power to the bay and shelf. not light when unit The unit is not properly seated. Ensure that the unit is properly and fully inserted into the correct is installed slots.

Problem Possible Causes Solutions AMUX does not There is no power to the unit. Check the power to the bay and shelf. appear on the status display Initialization is not complete. Wait for 4 minutes. If AMUX does not appear in the status display, note what is displayed there and restart the unit by removing it from the shelf and reinserting it. LINK LED does not light The RCV LED is not flashing The XMT LED is not flashing or the COT s NEAR LED is not lit The Data Alarm LED is lit shelf-to-shelf communication Buttons on the front panel have been pushed and the status display is showing a function or result. The unit is malfunctioning. There is no connection to 100BaseTX. The external 100BaseTX communications equipment port is not operating correctly. The unit is malfunctioning. data is being received from the 100BaseTX uplink. The unit is malfunctioning. data is being transmitted from the COTs connected to the access multiplexer. Uplink is not properly established. Data rate on the COT(s) is set to 0 kbps. The unit is malfunctioning. The unit did not initialize successfully. The unit is malfunctioning. communications cable in place. Bad cable between the shelves. Incorrect cable being used. The unit is malfunctioning. Wait for 5 seconds the menu and functions time out and the display returns to AMUX. Replace the unit. Verify the connection Check that the port on the Ethernet switch is configured for 100BaseTX full duplex or autonegotiate operation, OR Verify that the cable between the uplink port and the expansion port in daisy-chained systems is OK. Verify that the hub, router or switch used for 100BaseTX communications is operating correctly. Replace the unit. See Link LED does not light. Replace the unit. Check the connections from the COTs. Troubleshoot COTs according to their documentation. See Link LED does not light. Set the data transfer rate above 0 kbps. Replace the unit. See AMUX does not appear on the status display. Replace the unit. Connect the shelves through the appropriate RJ-45 connectors. Verify that the cable connecting the shelves is good. Check the uplink LED on the expansion shelf. Check the ports by connecting to a switch, router or hub to verify that the port is good (establishes a 100BaseTX link). Check the documentation for the correct cable to be used. Refer to the cable wiring information in this document. Replace the unit.

Section HVD-381-202 8. TECHNICAL ASSISTANCE If technical assistance is required, contact Charles Industries Technical Services Center at: 800-607-8500 847-806-8500 847-806-8556 (FAX) techserv@charlesindustries.com (e-mail) 9. WARRANTY & CUSTOMER SERVICE 9.1 Warranty Charles Industries, Ltd. offers an industry-leading, 5-year warranty on products manufactured by Charles. Contact your local Sales Representative at the address or telephone numbers below for warranty details. The warranty provisions are subject to change without notice. The terms and conditions applicable to any specific sale of product shall be defined in the resulting sales contract. Charles Industries, Ltd. 5600 Apollo Drive Rolling Meadows, Illinois 60008-4049 847-806-6300 (Main Office) 847-806-6231 (FAX) 9.2 Field Repairs (In-Warranty Units) Field repairs involving the replacement of components within a unit are not recommended and may void the warranty and compatibility with any applicable regulatory or agency requirements. If a unit needs repair, contact Charles Industries, Ltd. for replacement or repair instructions, or follow the Repair Service Procedure below. 9.3 Advanced Replacement Service (In-Warranty Units) Charles Industries, Ltd. offers an advanced replacement service if a replacement unit is required as soon as possible. With this service, the unit will be shipped in the fastest manner consistent with the urgency of the situation. In most cases, there are no charges for in-warranty repairs, except for the transportation charges of the unit and for a testing and handling charge for units returned with no trouble found. Upon receipt of the advanced replacement unit, return the out-of-service unit in the carton in which the replacement was shipped, using the preaddressed shipping label provided. Call your customer service representative at the telephone number above for more details. 9.4 Standard Repair and Replacement Service (Both In-Warranty and Out-Of-Warranty Units) Charles Industries, Ltd. offers a standard repair or exchange service for units either in- or out-of-warranty. With this service, units may be shipped to Charles Industries, Ltd. for either repair and quality testing or exchanged for a replacement unit, as determined by Charles Industries, Ltd.. Follow the Repair Service Procedure below to return units and to secure a repair or replacement. A handling charge applies for equipment returned with no trouble found. To obtain more details of this service and a schedule of prices, contact the CI Service Center at 217-932-5288 (FAX 217-932-2943). Repair Service Procedure 1. Prepare, complete, and enclose a purchase order in the box with the equipment to be returned. 2. Include the following information: Company name and address Contact name and phone number Inventory of equipment being shipped Particulars as to the nature of the failure Return shipping address

3. Ship the equipment, purchase order, and above-listed information, transportation prepaid, to the service center address shown below. CI Service Center 503 N.E. 15th St, P.O. Box 339 Casey, IL 62420-2054 4. Most repaired or replaced units will be returned within 30 or 45 days, depending on the product type and availability of repair parts. Repaired units are warranted for either 90 days from the date of repair or for the remaining unexpired portion of the original warranty, whichever is longer. 10. SPECIFICATIONS 10.1 Agency Compliance FCC P.15 Class A 10.2 Electrical Characteristics (a) INPUT VOLTAGE: 42 to 56 VDC (b) INPUT CURRENT: 750 ma maximum (c) POWER DISSIPATION: 31 watts maximum 10.3 Front Panel Interfaces Interface Connector Interface Standard Uplink and expansion ports RJ-45 IEEE 802.3 100BaseT 10.4 Physical Characteristics The physical characteristics of the HVDL Access Multiplexer are in Table 3. Table 3. Physical Characteristics Feature U.S. Metric Height 4.68 inches 11.88 centimeters Width 1.87 inches 4.74 centimeters Depth 8.99 inches 22.85 centimeters Weight 1 pound, 8 ounces 680 grams Temperature 0 to 140 F 0 to 60 C Humidity To 95% (no condensation)