Introduction of the Environmental Dust Test Device

Similar documents
Thermal Shock Chamber TSE 11

COSMO INSUTRUMENTS CO.,LTD. AIR LEAK TESTER

MOV Series Electric Ovens Dry Heat Sterilizers MOV-112F/212F MOV-112/212 MOV-112S/212S MOV-112F MOV-212

Specifications. Table of contents. 2:Specification. 3:Composition. 4:Instruments outside figure

Ionizer (Static Remover) STABLO-EX Instruction Manual

Environmental Radiation Monitoring System

Chapter 5 Inspection and maintenance

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

NORTH AMERICA JAE Shanghai Co., Ltd. JAE Europe, Ltd. JAE Electronics, Inc. JAE Taiwan, Ltd. JAE Tijuana, S.A. de C.V. OCEANIA

Variable Temperature Options for Optical Experiments

Faster Temperature (& Humidity) Chamber

Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS)

High Inlet Temperature Air Dryer. Desiccant Air Dryer. Membrane Air Dryer After-Clooler. Air Filter. Oil-Water Separator Automatic Drain Value

Compact Ultra Low Temperature Chamber

Using Portable Spot Air Conditioners in Industrial Applications

Advanced Ultraviolet Burner Controller

Chapter 5 Inspection and maintenance

OPERATION MANUAL. StableTemp Economy Mechanical Convection Oven. Model : ,-90,-91,-92,-93,-94

PERFORMANCE BY REGION. Japan. Minebea divides its operations into four regions based on the locations of its principal manufacturing facilities.

TOP TEN 2018 Energy Efficiency Technologies for the U.S. Building Sector

Technical Document Condensing hot water boilers

Faster Temperature (& Humidity) Chamber

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Environmental Chambers

SERIES & NO. SMI SUBJECT: SAFE CONSIDERATIONS FOR AN APPLICATION OF SPECIAL ELECTRICAL SYSTEMS

PERFORMANCE EVALUATION OF THE MINIATRIZED CATALYTIC COMBUSTION TYPE HYDROGEN SENSOR

Variable Temperature Microprobe Systems

Skymen Cleaning Equipment Shenzhen Co., Ltd. Ultrasonic Cleaner Instruction Manual

GAS CONTROL SYSTEMS SOLUTIONS OVERVIEW Manifold Systems Control Panels HP/UHP Regulators Pressure Gauges Valves&Fittings

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

Split Type Air Conditioners Goductless

MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011

Driven by CLIMATISATION. Excellence for professionals. Bosch air conditioning service units for R-134a and R-1234yf

Declaration of conformity maintenance record. No Revised date Contents Reasons Approval

Model Number Structure

Scale 0: 10 k Scale 50: 10 k (see note 2)

DRUM DRYERS FOR THE WOOD PELLET INDUSTRY

Effect of Contamination on the Sensitivity of Optical Scatter Smoke Sensors

Advancement In Coating Curing On Railcars

Manual No.'13 SAF-T-182. updated December 02,2013 TECHNICAL MANUAL AIR TO AIR HEAT EXCHANGE UNIT SAF150E6 250E6 350E6 500E6 650E6 800E6 1000E6

General Specifications

UV Weather Resistance Test Chamber Technical Data

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

HITACHI ROTARY COMPRESSOR MODEL SG153BG3GC I. SPECIFICATION. This specification is applied to SHANGHAI HITACHI rotary compressor. 2.

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

Refrigerant Leak Detector

Sinorix Silent Extinguishing Technology protecting the quiet way

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

No.THD51E To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual.

ED-FUW-2014 (50 Hz/60 Hz) Catalogue/Engineering Data. Large-Sized Chilled Water Fan Coil Unit (50/60 Hz) FUW040A DAIKIN INDUSTRIES, LTD.

Indicator light. What AirPatrol Lite does?

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

ACORE Filtration Co.,Ltd provides engineering,

compressed air system?

Corporate Overview. April

Pressure-Resistant and Explosion-Proof Electric Contact Pressure Gauges and Pressure Switches

Environmental Stress Chamber AR series

DLC Instruction Manual. Light Curing Machine MODEL. Table of Contents

SP METHOD 5320 Issue No: Test method for fire detection systems installed in engine compartments of heavy vehicles

NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet

Seismic Countermeasures for Environmental Radiation Monitoring System

Sheetfed offset technology. KBA Rapida 75. Technical information. Koenig & Bauer AG

Circuit Protector. GCP Series. Features. Electromagnetic Overcurrent Protection. Approvals. AC/DC Dual Voltage. Easily Identified ON/OFF Indicator

Tel: Fax: Website:

½ Monitored Pneumatic Valve Patented Technology

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

the Best Value ULVAC TECHNO, Ltd. for CORPORATE INFORMATION ULVAC TECHNO, Ltd.

Lloyd s Register Type Approval System Test Specification Number 3

G 7804 Laboratory Glassware Washer. Simplified Control, Miele Quality

INSTRUCTION MANUAL FOR RIKEN PORTABLE TOXIC GAS MONITOR

ZLA Series Double-stages Vacuum Transformer Oil Purifier Transformer Oil Purification

ISO INTERNATIONAL STANDARD. Smoke alarms using scattered light, transmitted light or ionization

FULL AUTOMATIC EXTINGUISHING SYSTEM FOR INDUSTRIAL MACHINERY YAC-3A. Table of Contents

HGRS / HGS background information

*For inquiries and questions about lasers, see the Yellow-Page.

MAYEKAWA MFG. CO., LTD Botan Koto-ku, Tokyo , JAPAN TEL:(81) FAX:(81)

Profile Photonic Sensing Consortium for Safety and Security

Monitored Pneumatic Valves On Series Ported Manifold

Performance. TCC-150 provides uniform temperature load, and highlyrepeatable temperature change rate. Conformity to JEDEC JESD22-A104-B standard test

Mounting Instruction

CKD refrigerating type dryer

FagronLab NP-1 UV. Negative pressure workbench. User Manual

Liquid to Liquid Thermal Shock Chamber TSB 21 TSB 51

Movement by Perfection. The Royal League in ventilation, control and drive technology. Fans for agriculture. Durable, efficient, well designed

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

High precision cleaning system. High precision cleaning system. PRECI Co., Ltd. Headquarters and Tokyo office. Contact for inquiries

Si REMOVAL PROCEDURE. 2.5/3.2/3.5 kw Class. Outdoor Unit Inverter Pair Type

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

½ Monitored Pneumatic Valves On Series Ported Manifold

SEMICONDUCTOR FABRICATION FACILITIES

Wafer Beveling Machine. Delivery Specification

ASSEMBLY & OPERATING INSTRUCTIONS

Air Specialties Express, 448 S. Main St., P. O. Box , Verona, WI Phone: (877) Fax: (608)

Tokushima Prefecture

: 1.5kw/AC220V.50Hz (AC110V 60Hz) : 340*200*30mm (3piece) 400*200*30mm (3 piece)

Instruction Manual for Dust Collector

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

SPECIFICATIONS PARTICLE SENSOR KS-41B Higashimotomachi, Kokubunji, Tokyo , Japan

Model gffoz Process Ozone Sensor (In-Line)

CASSETTE TYPE. AUT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N KEEP THIS MANUAL FOR FUTURE REFERENCE AM PM

Transcription:

Introduction of the Environmental Dust Test Device SIBATA SCIENTIFIC TECHNOLOGY LTD. Particulate Particulate Organism Organism Division Division SIBATA SIBATA SCIENTIFIC SCIENTIFIC TECHNOLOGY TECHNOLOGY LTD. LTD.

General Overview Products in the consumer sector have become smaller and more precise, and is assumed that they will be utilized in various environments. Various manufacturers have been performing tests on the product to improve performance and reliability in the research and development stages. Environmental tests are one of the tests that is recently receiving more attention.

General Overview This test evaluates product performance/functions when undergoing what would be considered typical environmental stress (temperature, humidity, vibration, air pressure) once manufactured such as change in temperature and humidity conditions, setup of environmental conditions of air contamination during packing, shipping, transportation, storage, setup, operation, disposal. Dust particles and corrosive gases are representative of conditions of air contamination; these concentrations can be set at an optional level and exposed for a certain time. SIBATA has developed various environmental test apparatus that are capable of supplying stable concentrations of dust particles and gases by applying environmental measurement device and control technology. These apparatus have been widely utilized by computer manufacturers, optical disk and acoustic instrument, automation device, and precision instrument makers.

Features Capable of testing JIS test particulates, various gases, and dust particulates. Dust concentrations within the chamber can be continuously recorded by the light scattering method dust meter. Automatic concentration control is possible by utilizing the continuous dust generator in conjunction with the dust concentration meter. Has a built-in in exhaust treatment device which removes and exhausts test particulates and gases. Air supply to the chamber is cleaned by a high performance filter; tests environments under class 1000 is also possible. Capable of testing temperature and humidity conditions when used in conjunction with an air device.

Uses Functional tests of computers and related instruments Functional tests of semi-conductors and mount print substrate Dust particle, gas exposure function tests of precision instruments Gas endurance tests of optical instrumentation Endurance tests of electrical parts of automobiles

Environmental particle test device Dust Particulate Dust Feeder Dust meter Electronic substrate Computers CD/DVD drives Car navigation systems Conceptual Diagram

Representative Flow Diagram

Setup Example

Model DTS-11

General Overview of Device This device is designed to test effects (load) of dust particles on specimen by setting up specimen in an environmental test room (chamber) and supplying and circulating a determined and controlled concentration of dust particles. The construction of the device can largely divided into a control panel, environmental test chamber, dust generator, and exhaust treatment apparatus.

Features Able to control a wide range of concentrations from low concentrations to high concentrations. Dust concentration is continuously measured with a digital dust monitor and printed with a recorder. A warning lamp will light and a buzzer will notify you of concentration abnormalities and malfunctions of the exhaust blower. Test particulates are treated with an exhaust cyclone, and high performance filters; only cleaned air is exhausted.

Specifications Model DTS-11 Test Particulate JIS Particulate Dust Concentration ~ 100mg/m 3 Dust Generator Ventilation flow rate Flow rate adjustor Concentration Observation Concentration control Supply/Exhaust Treatment Device Power Environmental Test Room Dust Feeder, Model DF-3 ~ 300L/min Frequency invertor Dust Concentration Control Unit, Model MR-632 ON/OFF control High performance filter AC100V, AC200V 3phase Dimensions 1000(W) 1000(D) 600(H)mm(widest part), Material SUS304

Model DTS-12

Overview of Device This device is a scaled-up version of the model DTS-11, and is designed to be used in conditions where the test specimen are large or when temperature and humidity need to be setup in the environmental chamber.

Features Is suited for large test specimen because the door of the entrance to the test chamber is large. Conditions inside the test chamber can be observed from the window. Heavy test specimen are also easily setup using the slope in the entrance. Has a wide range of concentration control from low concentrations to high concentrations. Air conditioners can be added optionally.

Model DTS-12 Test Particulate JIS Particulate Dust Concentration ~ 500mg/m 3 Dust Generator Ventilation flow rate Flow rate adjustment Concentration observation Concentraion Supply/Exhaust treatment device Power Dimension of test chamber Material of test chamber Specifications Dust Feeder model DF-5 ~ 1000L/min Frequency inverter Dust Concentration Control Unit, model MR-632 ON/OFF Control High performance filter, cyclone AC200V 3-phase Main room 2000(W) 2000(D) 3000(H)mm, Front room 2000(W) 2000(D) 2300(H)mm insulation... hard urethane, inside panel...stainless wire, Outside panel colored steel plate

Related Products Particle Generators Dust Feeder Cotton Dust Generator Digital Dust Meter Dust Concentration Control Unit

Dust Feeder Model DF-3

Dust Feeder Model DF-5

Digital Dust Meter Model AP-632

Dust Particle Concentration Control Unit Model MR-632

NEC Hitachi Hitachi Ricoh Olympus Optical Sony Corp. Hitachi Fujitsu Sony Corp. Panasonic Mitsumi Electric Co., Ltd Sony Corp. Sony Corp. Delivery History Fuchu, Japan 03. 88 Nakajyou,, Japan 04. 88 Asahi, Japan 10. 88 Hadano,, Japan 11. 88 Hachiouji,, Japan 08. 89 Honatsugi,, Japan 09. 90 Odawara,, Japan 09. 90 Kumagaya,, Japan 01. 92 Shinagawa, Japan 03. 92 Shikoku, Japan 05. 94 Honatsugi,, Japan 07. 95 Honatsugi,, Japan 08. 95 Honatsugi,, Japan 04. 96

Delivery History Columbia Music Entertainment Inc. Shirakawa,, Japan 08. 96 Aiwa Utsunomiya, Japan 01. 97 Nagano Industrial School Nagano, Japan 03. 98 Mitsumi Electronics Tendo,, Japan 07. 98 Panasonic Osaka, Japan 12. 98 Sony Corp. Kita-Shinagwa Shinagwa,, Japan 05. 99 Fujitsu Numatsu,, Japan 09. 99 Sony Corp. Konan, Japan 10. 99 Fujitsu Akashi, Japan 12. 99 Fuji Film Odawara,, Japan 05. 00 Sony Shinagawa, Japan 11. 01 Panasonic Yokohama, Japan 03. 02 LITE-ON Taiwan 09. 04

Sony Sony EMCS Panasonic Pioneer Korea KTL Panasonic Delivery History Sendai, Japan 03. 05 Sakado,, Japan 07. 05 Fujisawa, Japan 11. 05 Tokorozawa, Japan 01. 06 Korea 05. 06 Kadoma,, Japan 02. 07