VACUUM PUMP Model VCP-8101

Similar documents
Taking a Temperature

FOCAS ppm Bilge Alarm. Product Specifications Rev.1.03 (T)

To Purchase This Item, Visit BMI Gaming (800) Super Scooper OPERATION MANUAL

Specification Document. Single-circuit Embedded Water Leakage Detector AD-AS-1BM (RoHS-directive-compatible)

開会のあいさつ. Opening Address 東京大学生産技術研究所所長教授野城智也. Tomonari Yashiro Director General, Professor Institute of Industrial Science The University of Tokyo

K-Band Doppler Sensor Module

What s New? Niihama City No.217 September Published by SGG Niihama. My life on Tatami

Surface Mount Type. Outline Dimensions 外形寸法図. Surface Mount Type LED

Safety Precautions 安全上の注意

4. Contact arrangement 回路形式 1 poles 1 throws 1 回路 1 接点 (Details of contact arrangement are given in the assembly drawings 回路の詳細は製品図による )

NSHU591B Built-in ESD Protection Device RoHS Compliant

Low-Profile Pyranometer ML-02

NSPU510CS Built-in ESD Protection Device RoHS Compliant

PRODUCT NAME. Thermo-dryer MODEL. Original Instructions IDH4-10, IDH4-20, IDHA4-23 IDH6-10, IDH6-20, IDHA6-23

PRODUCT NAME. Thermo-dryer MODEL. Original Instructions IDH4-10, IDH4-20, IDHA4-23 IDH6-10, IDH6-20, IDHA6-23

Refrigerated Air Dryer


INSTALLATION GUIDE. AXIS T8008 PS12 Power Supply

Refrigerated Air Dryer

BAS-341H BAS-342H. 取扱説明書 基本編 Basic Operation Manual 使用说明书 基本篇 Manual básico de operación

Tsukuba Life Handbook つくばでの生活ガイド

Formulating Time Tested Knowledge for Sustainable Disaster Risk Reduction; A Case Study of Kathmandu

Wall-Mount Enclosures: Standard and NEMA

Shoot Formation in Populus Callus Tissues precultured in vitro on Some Different Media

Control Panels Variable Frequency Drives Float Switches Alarm Systems For Water/Wastewater Pump and Motor Control. Visit worldwide link at

Visit worldwide link at

PV-XA100. Instruction Manual. Hitachi Cordless Stick Cleaner. Contents. Model. Before use. How to use. When Finished cleaning. Appendix E-2 E-4 E-7

Exhibitor s guide July (Wed Fri)

Operation Manual. Hatsuta Seisakusho Co., Ltd.

Refrigerated Air Dryer

Mitsubishi HEMS. Mitsubishi Electric Smart House Solution

ICT for Society and Happiness

In-mold laminating. ( Kunststoffe International 3 ) ( Kunststoffe International 3 p.24-26) BMW M3 CSL. ( Kunststoffe International 3 p.

Operation Manual. Original Instructions PRODUCT NAME. Refrigerated Air Dryer. MODEL / Series

IDX-OM-H006-I Initial issue: January th edition : November Operation Manual. Refrigerated Air Dryer. Series

タイ工業規格 (TIS) の概要と認証マークの取得について

Operation Manual. Refrigerated Air Dryer

3KSMC895 9KSMC895 Book 1.indb 1 5/30/2018 8:44:08 PM

同志社大学留学生宿舎申込書 (2010 年度 ) Application for Accommodation for International Students (2010) Doshisha University Center for Japanese Language and Culture

Chemical resistant Vacuum Pumps

Operation Manual PRODUCT NAME. Refrigerated Air Dryer. MODEL / Series

International Catalog

Takaaki Koganezawa, Miyagi University of Education Yoshitaka Miyake, Ph.D. student, the University of Hawai`i at Mānoa

Agilent Intuvo 9000 Gas Chromatograph

Nichia STS-DA <Cat.No > SPECIFICATIONS FOR NICHIA UV NSHU591A MODEL : NICHIA CORPORATION

USER MANUAL UN-200V / UN-200VH

パルスヒートユニットシリーズ. Pulse Heat Unit Series

at Hotel Mulia Senayan - Jakarta

SANSAI. Newsletter. Collaboration in the Indochina Region 藤枝絢子 地球環境学堂助教 小林広英 同准教授

OPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø)

Reproductive Phenology and Allocation in Rubus palmatus var. coptophyllus in the Understory of a Pinus densiflora Stand

Objectives. on managing green spaces and mitigating the effects of UHIs.

Adam Style in English Country Houses: Function and Decoration in the Georgian Era

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

Magnetically Levitated Turbo Molecular Pump INSTRUCTION MANUAL

OPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø) Model: 3200FA (220v-240V 1Ø) Voltage Supply to Machine:

LATEST HEAT PUMP TECHNOLOGIES IN JAPAN. Waseda University Kiyoshi Saito

AXIS M50-V Series AXIS M5014-V

Unit D1B Up, Bounds Green Industrial Estate, Ringway, London N11 2UD, UK

ProQuest Dissertation

Combustion Properties of Fuelwood in Hot-Air Heaters

Pilot study report : The Liberty Tower of Meiji University Tokyo, Japan

457LAVBP10QT LAVEX HEPA BACKPACK VACUUM CLEANER

k5 karcher outlet 1BD132765DD7B647DABCDDA616C64F57 K5 Karcher Outlet 1 / 6

Good Practices in Radiation Exposure Dose Reduction Measures

World Heritage Property

Plant Regeneration from Embryogenic Calli of the Wild Sugarcane (Saccharum spontaneum L.) Clone Glagah Kloet

Instruction Manual. D150 Dual Gas Reactor Column

OPERATING MANUAL English Chemical Resistant Diaphragm Pump

FUJI IGBT V-IPM APPLICATION MANUAL

Sentry Equipment Cabinet Environmental Monitor

持続可能な社会実現のためのチーム ビルディング 世界の課題に取り組む大学の新たな組織づくりとサステイナブル オフィスの役割 -

FUJI IGBT V-IPM APPLICATION MANUAL

ALSO INSIDE: John C. Portman III Reflects on Shanghai Centre's 25 th Anniversary. PLUS All the latest Shanghai Centre FALL news COVER STORY

Installation. InRow SC ACSC100 ACSC101

OWNER S MANUAL FOR ASPIRATION / FILTRATION VACUUM SYSTEM MODELS: 2511 & 2515

Hoshizaki America, Inc.

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

Electrical Appliances and Materials Safety Act Statutory Operations Implementation Guide. 3rd version

Vertical Gel Systems-Dual CAT NO: EPS-V0011 & EPS-V0012

Ralph lauren boxwood sage

Mobile Air Conditioner Instruction Manual Model TC-N9KM

INSTALLATION & OPERATION MANUAL

Read this entire manual before operation begins.

Part No Revised: June TS1 TOASTER SYSTEM Instruction Manual Models # 5700 AND # 5700SF

Operation Manual R205BV, R209BV

Agilent Dissolution Seminar Series

WARNING. Pro Pack Portable Spray Pack 3A1292C. Operation. Model 24F893 Maximum Working Pressure 12 psi (0.83 bar, MPa)

OPERATOR S MANUAL WET/DRY VACUUM PF51 WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT.

Household Goods Quality Labeling Act Handbook

国際連合 糧農業機関 (FAO) 本事務所

USER MANUAL. Electric Open Well Steam Tables. Models: 423EST2WE, 423EST3WE, 423EST4WE500, 423EST4WE750, 423EST5WE

AC-12200E Portable Air Conditioner

High Output Vacuum/Pressure Pump

IV Dry Cleaning. Contents (Dry Cleaning)

12U Wall-Mount Rack RK12WALLO

The 10 th Three Associations Meeting JRAIA. The Japan Refrigeration and Air Conditioning Industry Association. August 31, 2016.

OWNER S MANUAL (English)

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

トイレ トイレの歴史. By: Jenny Ko Stephanie Lo

Transcription:

VACUUM PUMP Model VCP-8101 Thank you for choosing the LMS Model VCP-8101 Vacuum Pump. Your Vacuum Pump is CE Certified and designed to be safe, reliable and easy to operate. Please read this thoroughly before operating the Vacuum Pump. Failure to observe the instructions may cause damage to the equipment. Pre-Operation Checks 1) Place and operate your Vacuum Pump on a clean, level surface, preferably in a well ventilated area. 2) Connect a vacuum tubing to the vacuum inlet of the Vacuum Pump. Clips are not required when the Pump is used for vacuum. 3) Loosen the Drain Valve to release any vacuum within the system and to drain any water in the moisture trap. 4) Connect the Power Cable to a grounded power outlet.

Operation 1) Turn on the power to the Vacuum Pump (if necessary). 2) Switch the Vacuum Pump on using the power switch located at the top of the unit. 3) Tighten the Drain Valve. 4) During operation, it is normal for the Vacuum Pump to become hot. Refrain from touching the metal parts during operation to avoid getting burnt. 5) The Vacuum Pump is not designed for prolonged periods of continuous use. A thermal switch cuts off power when the Vacuum Pump gets too hot to prevent internal damage. 6) The VCP-8101 Vacuum Pump is designed to evacuate air only. When operating as a vacuum source for liquid filtration, it must be used with a reservoir between the filter and the Vacuum Pump (see Figure 2). 7) Ensure that no liquid enters the pump. Liquid inside the pump voids the warranty. 8) When used to provide vacuum for acidic filtration, a suitable neutralizer must be placed between the reservoir and the Pump (see Figure 2). 9) The VCP-8101 is not designed to be used with corrosive and explosive media. Failure to heed this instruction may result in equipment damage and personnel injury. 10) Glassware and apparatus used in the setup must be designed for use with vacuum to prevent damage and injury caused by imploding glassware. 11) After operation, the power should be turned off and the Drain Valve opened. Pressure 1) While the VCP-8101 is designed primarily as a Vacuum Pump, it can be used to provide pressure with an optional Pressure Kit. 2) When used for pressure, the tubing ends must be securely clamped (Clips not supplied) 3) Glassware and apparatus used in the setup must be designed for use with pressure to prevent damage and injury caused by exploding glassware. Maintenance 1) This is an Oil-less Vacuum pump. The use of lubricants can cause damage to the pump and voids the warranty. 2) The Pump should be routinely cleaned with a clean and damp cloth. Do not use chemical and abrasive cleaners on the pump. 3) Check the condition of the Moisture Trap, Filter and Power Cord regularly.

Figure 1: Parts of the Vacuum Pump Index Description Q ty Index Description Q ty Index Description Q ty 1 Set screw 4 17 Cylinder 1 33 Condenser 2 Fan cover 1 18 Valve plate 2 34 On/Off Switch 1 3 Cooling fan 1 19 Valve plate lock 2 35 Plug 1 4 Rear body 1 20 Set screw 2 36 Air intake filter 1 5 Set screw 2 21 Paper pad 1 37 Condenser cover 1 6 Stationary motor 1 22 Front body lid 1 39 Connecting Rod 1 7 Bearing 2 23 Set screw 4 40 Pressure gauge 1 8 Rotary Motor 1 24 O-ring 1 41 Moisture trap 1 9 Front Body 1 25 Cylinder block 1 42 Drain valve 1 10 Counterweight 1 26 O-ring 1 48 Isolation 1 12 Bearing 1 27 Cylinder head 1 65 Tier connector 1 14 Compressing ring 1 28 Set screw 4 66 Airfilter (air inlet) 1 15 Lock plate 1 30 Handle 1 16 Rubber stand 4 31 Cable protector 1

Figure 2: Pump connected to Filtration Device with Reservoir and Neutralizer

イメージを表示できません メモリ不足のためにイメージを開くことができないか イメージが破損している可能性があります コンピュータを再起動して再度ファイルを開いてください それでも赤い x が表示される場合は イメージを削除して挿入してください Warranty Statement LMS guarantees that the device is free from manufacturing defects when shipped from the factory. Should there be any manufacturing defects, LMS will replace the device or repair the defect within 12 months from the date of purchase. Warranty does not cover units with damaged manufacturer s label, damaged seals, damage through improper use and improper storage. Warranty does not cover parts damaged through normal wear and tear. No service manual is available. If the unit is dismantled for any reason, except by the manufacturer or personnel authorized by the manufacturer, all warranties are null and void. Warranty claims and service requests must be made through the distributor from whom you purchased the unit. Name of Distributor Address Model Number Description Serial Number Date of Sale LMS CO., LTD. Tanaka Bldg., 3-6-7, Hongo, Bunkyo-ku, Tokyo, JAPAN Tel: +813-5842-4171 Fax: +813-5842-4180 E-mail: info@group-lms.com