Essenza. Square Downlights

Similar documents
Essenza. Round Downlights

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

Evoke Square Downlight

Evoke 2.9" HP. 2.9" Square Downlight

Evoke Round Downlight

Evoke Square Downlight

Evoke Square Downlight

Evoke 2.9" HP. 2.9" Square Downlight

Classix 6" 6" Round Lens Downlight

Hornet HP. Round Glass Downlight

Evoke 2.9" HP. 2.9" Round Lens Wall Wash

Evoke Round Adjustable C3

Evoke Square Adjustable C3M

Evoke Square Adjustable HP

Velato. Recessed Slot Adjustable Multiples

Classix 6" 6" Round Lens Wall Wash

Classix 6" 6" Round Lens Wall Wash

Performance Chart Electrical Data

Performance Chart Electrical Data

Hornet HP. Square Glass Downlight

Performance Chart Electrical Data

Performance Chart Electrical Data

Classix 6" 6" Round Lens Wall Wash

Evoke Square Adjustable HP

Classix 6" 6" Round Adjustable C3M

Hornet HP. Recessed 4-Light Square Multiple

Hornet HP. Semi-Recessed 4-Light Square Multiple

Classix 6" 6" Round Adjustable C3

Classix 6" 6" Round Adjustable C3

Performance Chart Electrical Data

approved to UL standard as tested by CSA Damp location Wet location option (adds clear lens and trim gasket) IC/AT rated (27w only) 4 11 / / 8

Classix 6" 6" Round Downlight

Performance Chart Electrical Data

Murro HP. 3.5" Round Surface Canopy Wall Wash

Etch 2' x 2' Recessed LED

Cylindrix III Mini. 3.5" Round Surface Canopy

Grüv Flare Regressed. Recessed Linear LED

Grüv Flare Regressed. Recessed Linear LED

HORNET-HP-R- A14-3 3LT LED

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Fino. Asymmetric Wall Mount Indirect LED

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Linea 1.5. Linear Direct Wall Wash LED

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

IHOL-8DS / ISD802 8 Gravity LED Square Downlight with Regressed Lens - Wet Location

3.75 Gyro Shift Multiples Single Head

Ordering Example: Specify trim code and housing code to order: Example : 1020W - B LRTD M2-27KS NCSM - 277V - DIML2 - CB27

Linea 2.5. Linear Indirect LED

USAI. BeveLED2.1. BeveLED. COLOR SELECT Covered By US Patents 8,581,520 and 8,456,109 DOWNLIGHT 1 REGRESS DOWNLIGHT DEEP REGRESS DOWNLIGHT.

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) F Frosted S Solite (provided standard) RETROFIT

Fixture Summary (see following pages for more information) Performance Chart Wattage Per Foot. Standard Patterns " "

DRD5S & SurfaceFrame Alt/EM Surface Mount LED Downlight

DRD5S & SurfaceFrame Alt/EM 18" Linear Surface Mount LED Area Light

PROJECT INFORMATION DELIVERED PERFORMANCE. BeveLED REGRESS DOWNLIGHT DELIVERED PERFORMANCE. BeveLED 2.1 WGD DEEP REGRESS DOWNLIGHT

BEVEL STYLE LENS B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

PROJECT DATE FLANGE FINISH

IHOL-S4DR / IRDS400 4 Gravity LED Shallow Downlight

IHOL-4DR / IRD400 4 Gravity LED Downlight

IHOL-6DS / ISD600 6 Gravity LED Square Downlight

Linea 2.5. Linear Direct/Indirect LED

DIMMING: (optional) Multiple dimming drivers available. See compatibility chart attached.

IHOL-6DR / IRD600 6 Gravity LED Downlight

80 Watts FLANGE FINISH

FLANGE FINISH. New Construction, Narrow Width IC Insulation-Contact Rated / Airtight 2 40KS 4000K, 80+ CRI CP Chicago Plenum beam beam

FLANGE FINISH VOLTAGE. NC New Construction CP Chicago Plenum 2 IC Insulation-Contact Rated / Airtight 2 120V 277V

PROJECT INFORMATION PROJECT

PROJECT INFORMATION B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

Ordering Example: Specify trim code and housing code to order: Example : 1251W - B LRTW M2-27KS - NCSM - 277V - DIML2 - CB27

PROJECT INFORMATION DELIVERED PERFORMANCE. Performance based on: 3000K, 50 beam

PROJECT INFORMATION. DATE Covered By US Patent 8,456,109 and 8,581,520

USAI ADJUSTABLE. Lighting

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. VOLTAGE. LED - high performance LED 80-80CRI 90-90CRI

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (Leave blank for AB1 and AC1 Bevel Styles)

Type: Project : Luminaire characteristics: Source: Lumen maintenance: Optics: Material: Mounting: Electrical: Finish: Weight:

Linea 3.5. Linear Direct/Indirect LED

Evolution EXWW RECESSED LINEAR WALL WASH LUMINAIRE

DATE TYPE 40 DELIVERED PERFORMANCE

PROJECT INFORMATION PROJECT DATE. 9 Watts 12 Watts 16 Watts 24 Watts 33 Watts

Stocking Solutions. Downlights LED Panels Floods & Wall Packs

PROJECT INFORMATION. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

lumenalpha downlight Specification Sheet

CCT LED ARCHITECTURAL MINI

TROFFER RETROFIT KIT (TRK)

PROJECT INFORMATION PROJECT DATE. 9 Watts 12 Watts 16 Watts 24 Watts 33 Watts

OPTIONAL LENS 2 FLANGE FINISH

PROJECT INFORMATION LENS. S Solite (provided standard) F Frosted. FTA BabyLED Flat. Housing. New Construction 2 FTIC BabyLED Flat 2

INTERNATIONAL. Ordering Example: Specify trim code and housing code to order: Example : 3253INT - B LRTW WGD1-2722KS - INT10 - CGBO

Project: Comments: Prepared By: Control. Code Fixture & Trim D3 Wall Wash, Round. Platform & Control Wide Gamut, Tunable

FLANGE FINISH LENS. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (provided standard)

Exterior LED Cylinder Lighting To The Next Level. FCC900 Series. delivering up to 5000 LUMENS! Specification Sheet

PROJECT INFORMATION FLANGE FINISH

NOVA CEILING WALL GRAZER WITH REMOTE POWER

CRENSHAW. Board and driver LED standard systems for ceiling mounts. Crenshaw LED. Standard Ceiling Options

USAI. BeveLED 2.1 International Dimming Compatibility. Lighting River Road New Windsor, NY

CIRRUS CEILING WALL GRAZER WITH REMOTE POWER

Ivalo Lumaris LED Linear Lighting

ULTRA RT6 and RT6 Gimbal LED Recessed Downlight Kit

Ivalo Lumaris. LED Linear Lighting. High quality, even lines of illumination and guaranteed LED compatibility with 1% Lutron dimming IVALO COLLECTION

RECESSED - WITH StepLens OPTION

Transcription:

Downlight Adjustable Features Essenza LED Downlights are designed to deliver the features required for your Hotel and Residential High Rise or Commercial projects. Available with 12W or 18W LED modules, and centered around the outputs of traditional MR-16 s, the Essenza is perfect for your lighting needs in these areas. The shallow frame (only -1/8" plenum depth) is universal to accept either round or square (standard) trims. Trims available include Downlight, Adjustable Accent, Wall Wash and Lensed Shower trims, giving designers the ability to complete any design scheme. Product Overview Type: Recessed Square Downlight, Accent, Wall Wash Wattage: 12W, 18W Lumen Output: 1,025 max;.2 Lm/W (EZSD Spot optic) CBCP: 8,82 max (EZSD Spot optic) Color Temp: 2200K, 2700K, 000K, 500K, 4000K CRI: 8 typ. (2700K, 000K, 500K, 4000K) + typ. (2200K, 2700K, 000K, 500K, 4000K) CrispWhite & K Class A available Dimming: TRIAC & ELV (120V/277V) - 5% Dim Lutron A Series (120V/277V), -wire/ecosystem Hi-lume - 1% dim Lutron H Series (120V/277V), EcoSystem, Hi-lume - 1% dim with soft on, fade to black 0-10V (120V/277V) - 1% Dim DALI dimming - 1% Dim Fixture Type New Construction Remodeler Trim Trimless Yes Yes Yes Yes Lens Wall Wash Shower Performance Chart Wattage Delivered Lumens LPW CBCP Color Temp 12 85 64 7,57 000K-+ 18 1,025.2 9,015 000K-+ Data is based on 000K-97 IES files available on website Data is EZSD Spot optic. See pages 6-9 for other beam spreads All wattage and LPW includes 2W thermal protector Pinhole Downlight Title 24 Compliant Electrical Data 12W 18W System System Watts Amps Watts Amps 120V 12 0.10 18 0.15 277V 12 0.04 18 0.06 Electronic constant current LED driver Includes 2W thermal protector LIT-2069 06/15/18 Page 1 of 1 Amerlux, LLC 178 Bauer Drive, Oakland, NJ 0746 P: 97-882-5010 F: 97-882-25 amerlux.com

Housing/Frame Ordering Information 1 2 4 5 6 1 2 Model For New Construction EZ-NC-A17 (New Construction) EZ-CP-A17 (Chicago Plenum (CCEA) housing, 12W only) EZ-IC-A17 * (Insulated Ceiling/air tight housing, 12W only) For Existing Ceilings EZ-REM-A17 (Remodeler, for existing ceilings) Style T - trimmed STL - square trimless Wattage 12* 18 (not available for use with CP or IC housing) 4 5 6 Voltage 120 277 120/277 (for use with IC housing only) Driver (for non-dimming, select LE/TE option) LE/TE* - TRIAC/ELV dimming HILUME-A - Lutron Hi-lume A Series, -wire/ecosystem, Hi-lume, 1% dim HILUME-H - Lutron Hi-lume H Series, EcoSystem Hi-lume, 1% dim with soft on, fade to black 0-10V* - 0-10V dimming; 1% dim DALI - DALI dimming, 1% dim Options/Accessories EM - integral emergency battery pack with remote test switch, requires 7" ceiling clearance (not available for use with REM, CP or IC option) Trim Ordering Information 1 2 4 5 1 2 Model EZSD-A17 * (downlight) EZSA-A17 * (adjustable) EZSLW-A17 (wall wash) EZSSHW-A17 * (shower, not available for use in trimless) EZSPD-A17 * (pinhole downlight) Style T - trimmed TL - trimless (not available for Shower (EZSSHW) trim) Finish SD/SA/SLW/SSHW Trims: Trimmed MWW - matte white, white flange Trimless MW - matte white 4 5 Beam Spreads (not for use with EZSLW trim) SP - spot, 15 FL - flood, 28 WF - wide flood, (not available for use with EZSPD trim) VWF - very wide flood, (not available for use with EZSPD trim) Color Temp 8 CRI + CRI 27-2700K-8 229-2200K-+ CRISP - CrispWhite 0-000K-8 279* - 2700K-+ CLA - K Class A 5-500K-8 09* - 000K-+ 40-4000K-8 59-500K-+ 409-4000K-+ SPD Trim (Trimmed & Trimless): MW - matte white * Title 24 Compliant The "A" refers to the sequential revision in a year and "XX" refers to the year of update. Updates coincide with improved performance while not changing the overall fixture aesthetic and are reflected in the published performance data. Please contact your Amerlux representative for explanations of changes. LIT-2069 06/15/18 Page 2 of 1 Amerlux, LLC 178 Bauer Drive, Oakland, NJ 0746 P: 97-882-5010 F: 97-882-25 amerlux.com

Specifications Application Hospitality, retail and commercial ambient, accent and wall wash lighting Construction 20 ga. galvanized steel frame 18 ga. galvanized steel splice housing and hanger brackets (not for use with Remodeler version) Cast aluminum plaster frame with perforated face (for trimless version only) Die-cast optical housing, trim and heatsink Optical Beam spreads (for SD, SA, SSHW & SPD fixtures): Spot, 15º; Flood, 28º; Wide Flood, º; Very Wide Flood, º Tilt (for SA fixture): 0-0 tilt lock, 55 rotation Lens: SLW fixture: Engineered nano technology lens provides high transmission while concealing LED image Shower fixture: Siliconed solite lens LED Color Temp Options: 2200K, 2700K, 000K, 500K, 4000K CRI: 8 typ. (2700K, 000K, 500K, 4000K) + typ. (2200K, 2700K, 000K, 500K, 4000K) CrispWhite* LED available Class A** 000K (high CRI, high gamut) R9 Values: 11 (8 CRI), 55 (92 CRI) Binning: MacAdam (SDCM) Life: 50,000+ hrs, > 70% of initial lumens at 50,000 hrs *CrispWhite: CrispWhite Technology delivers the warmth of colors expected from a high CRI solution but also creates the natural crisp white color that is pleasing to the eye. It creates the most impactful lighting ever available, by revealing the richest whites and vibrant colors that pop. **Class A LED: Class A LED s have a CRI > 80 and a GAI > 80. CRI defines color Naturalness and GAI defines color Saturation. Both being high delivers rich colors and pure whites. Electrical Wattage: 12, 18 Electronic constant current LED driver, 120V/277V input This product complies with IEEE C62.41 for surge endurance up to 2.5KV. Amerlux recommends using additional surge protection with this unit (supplied by others), surge and over voltage damage is not covered under warranty. Note: Drivers are universal but thermal protector is voltage specific Drivers LE/TE - Leading Edge, TRIAC, forward phase/trailing Edge, ELV, reverse phase 0-10V and Lutron systems also available See pages 6-9 for more dimming information Finish Powder coat paint Consult factory for custom finishes Mounting Trimmed For use in T-grid or sheetrock ceilings, max thickness 1" Trimless For use in sheetrock ceilings, max thickness 5/8" Certifications CSA listed to UL standards Damp location Wet location (with Shower trim) IC/AT (insulated ceiling/air tight) rated, 12W only, optional Chicago Plenum (CCEA) optional Title 24 Compliant (see ordering page for options that apply) Warranty year limited warranty LIT-2069 06/15/18 Page of 1 Amerlux, LLC 178 Bauer Drive, Oakland, NJ 0746 P: 97-882-5010 F: 97-882-25 amerlux.com

Essenza Square Downlight: 14 1 /2 min - 26 max 11 1 /2 8 1 /16 2 1 /4 Optional IC/AT housing (12w only) 7 /4 6 1 /8 9 12 /16 4 4 1 7 /16 Ceiling cut out: 4 dia. Downlight Adjustable 0 up to 1 Lens Wall Wash Shower /8 up to 1 /8 Tilt lock screw up to 1 up to 1 /8 /8 Pinhole Downlight Frame with Emergency Battery Pack Emergency Battery Pack up to 1 1 1 /16 7 /4 11 7 /8 5 1 /2 7 1 /2 Ceiling 11 1 /2 1 9 /16 14 1 /2 min - 26 max LIT-2069 06/15/18 Page 4 of 1 Amerlux, LLC 178 Bauer Drive, Oakland, NJ 0746 P: 97-882-5010 F: 97-882-25 amerlux.com

Essenza Square Downlight Trimless: 14 1 /2 min - 26 max Optional IC/AT housing (12w only) 7 /8 7 /4 12 /16 4 7 1 /2 11 1 /2 Trimless Ceiling cut out: 4 1 /2 sq. Downlight Adjustable 0 Tilt lock screw Lens Wall Wash Pinhole Downlight 1 1 /16 Plaster Frame Installation Detail (for trimless fixture only) Frame with Emergency Battery Pack 6 Emergency Battery Pack 4 5 2 1 7 /4 11 7 /8 5 1 /2 1. Reflector Trim 2. Aperture plate. Ceiling ⅝ 4. Cast Aluminum Plaster Frame 5. Plaster Skim Coat (by others) 6. 6-2 Type F Thread Cutting Screw 7 1 /2 Ceiling 11 1 /2 1 9 /16 14 1 /2 min - 26 max LIT-2069 06/15/18 Page 5 of 1 Amerlux, LLC 178 Bauer Drive, Oakland, NJ 0746 P: 97-882-5010 F: 97-882-25 amerlux.com

Essenza Square Remodeler: 5 /16 8 1 /16 4 2 1 /4 Ø6 1 /4 1 /16 A STRUCTURE 5 /16 2 1 /4 (1" max) 5 1 /2 min Clearance Product A EZ-SD-REM 2 /8 EZ-SA-REM /16 EZ-SLW-REM 5 /16 EZ-SSHW-REM 2 /8 EZ-SPD-REM 2 /8 To allow driver removal through cut out. 7 9 /16 Ceiling cut out: 4 dia. Downlight Adjustable 9 1 /2 9 1 /2 1 /16 1 /2 2 9 /16 2 9 /16 0 Tilt lock screw Lens Wall Wash Shower 9 1 /2 9 1 /2 5 /16 1 /16 2 9 /16 2 9 /16 Pinhole Downlight 9 1 /2 1 /16 2 9 /16 1 1 /16 LIT-2069 06/15/18 Page 6 of 1 Amerlux, LLC 178 Bauer Drive, Oakland, NJ 0746 P: 97-882-5010 F: 97-882-25 amerlux.com

Essenza Square Remodeler Trimless: 4 STRUCTURE Product A 5 /16 8 1 /16 2 1 /4 1 /16 5 /16 2 1 /4 5 1 /2 min Clearance EZ-SD-REM-TL EZ-SA-REM-TL /16 EZ-SLW-REM-TL 1 /4 EZ-SPD-REM-TL 7 9 /16 A To allow driver removal through cut out. Trimless Ceiling cut out: 4 1 /2 sq. Downlight Adjustable 11 1 /16 11 1 /16 1 /16 7 /16 2 9 /16 2 2 9 /16 5 /16 0 Tilt lock screw Lens Wall Wash Pinhole Downlight 11 1 /16 11 1 /16 1 /4 1 /16 2 9 /16 2 9 /16 1 1 /16 Plaster Frame Installation Detail (for trimless fixture only) 1. Reflector Trim 2. Aperture plate. Ceiling ⅝ 4. Cast Aluminum Plaster Frame 5. Plaster Skim Coat (by others) 6. 6-2 Type F Thread Cutting Screw 1 2 5 6 4 LIT-2069 06/15/18 Page 7 of 1 Amerlux, LLC 178 Bauer Drive, Oakland, NJ 0746 P: 97-882-5010 F: 97-882-25 amerlux.com

Essenza Square Downlight: FIXTURE DATA: (Complete photometric data (.ies format) available upon request) MULTIPLYING FACTORS: (Multiplying Factor is based on 000K-97 120V IES file on website) Wattage: 12W 18W Factor: 0.84 1.0 CCT: 2700K-8 000K-8 500K-8 4000K-8 Factor: 1.16 1.20 1.2 1.25 CCT: 2200K-+ 2700K-+ 000K-+ 500K-+ 4000K-+ CRISP CLA Factor: 0.85 0.96 1.0 1.05 1.08 0.79 0. 18W LED, 000K-+ Spot (SP) Distribution, 15º LTL #1162282 Lumens: 1025 Flood (FL) Distribution, 28º LTL # 11628 Lumens: 9.1 Wide Flood (WF) Distribution, º LTL # 116284 Lumens: 957.2 Very Wide Flood (VWF) Distribution, º LTL # 116285 Lumens: 921.5 2250 0 500 1 00 1500 1000 50 2250 1500 525 00 2000 700 0 882 5 6106 15 100 25 164 5 57 17 0 2694 5 2498 15 189 25 1 5 115 8 0 1984 5 1888 15 1266 25 570 5 184 56 0 66 5 658 15 624 25 58 5 176 Application Data: 0 o Aiming Angle Horizontal Footcandles Spot Flood Wide Flood Very Wide Flood 5.0 54 1.4 1.4 7.5 157 2.0 2.0 10.0 89 2.8 2.8 12.5 57.4.4 5.0 108 2.76 2.67 7.5 48.8.9 10.0 27 5.2 5.2 12.5 17 6.4 6.6 5.0 80.1.1 7.5 6 4.6 4.5 10.0 20 6.1 6.0 12.5 1 7.6 7.5 5.0 27 5.4 5.4 7.5 12 8.2 8.1 10.0 7 11.1 11.0 12.5 5 14.1 14.0 W D L FC Notes and Definitions: Beam spread is to 50% center beam candlepower (CBCP). D=Distance to floor or wall. FC=Footcandles on floor or wall at center beam aiming location. L=Effective Visual Beam length in feet (50% of maximum footcandle level). W=Effective Visual Beam width in feet (50% of maximum footcandle level). CB=Distance across or down to center beam location. LIT-2069 06/15/18 Page 8 of 1 Amerlux, LLC 178 Bauer Drive, Oakland, NJ 0746 P: 97-882-5010 F: 97-882-25 amerlux.com

Essenza Square Adjustable: FIXTURE DATA: (Complete photometric data (.ies format) available upon request) MULTIPLYING FACTORS: (Multiplying Factor is based on 000K-97 120V IES file on website) Wattage: 12W 18W Factor: 0.84 1.0 CCT: 2700K-8 000K-8 500K-8 4000K-8 Factor: 1.16 1.20 1.2 1.25 CCT: 2200K-+ 2700K-+ 000K-+ 500K-+ 4000K-+ CRISP CLA Factor: 0.85 0.96 1.0 1.05 1.08 0.79 0. 18W LED, 000K-+ Spot (SP) Distribution LTL #1162 Lumens: 911.7 Flood (FL) Distribution LTL # 116291 Lumens: 80.1 Wide Flood (WF) Distribution LTL # 116292 Lumens: 810 Very Wide Flood (VWF) Distribution LTL # 11629 Lumens: 71.7 2000 0 500 1 4000 1500 1000 50 00 1500 525 8000 2250 700 0 1282 5 206 15 8410 25 2661 5 221 14 0 164 5 1946 15 2617 25 1821 5 462 1 0 1227 5 15 15 185 25 12 5 529 51 0 68 5 701 15 689 25 619 5 84 104 Application Data: Spot Flood Wide Flood Very Wide Flood 15 o Aiming Angle Horizontal Footcandles CB 5.0 254 1.97 1.5 1.0 7.5 15 2.1 2.0 2.0 10.0 69.0 2.79.0 12.5 48.6.5.0 CB 5.0 95 2.7 2.7 1.0 7.5 42 4.0.9 2.0 10.0 24 5.2 5.2 2.0 12.5 16 6.5 6.5.0 CB 5.0 69.1.1 1.0 7.5 0 4.7 4.7 2.0 10.0 17 6.2 6.2 2.0 12.5 11 7.8 7.8.0 CB 5.0 28 4.4 4.8 1.0 7.5 12 6.8 7.2 1.0 10.0 7 9.0 9.5 1.0 12.5 5 11.4 12.1 1.0 W D L FC 0º CB FC Notes and Definitions: Beam spread is to 50% center beam candlepower (CBCP). D=Distance to floor or wall. FC=Footcandles on floor or wall at center beam aiming location. L=Effective Visual Beam length in feet (50% of maximum footcandle level). W=Effective Visual Beam width in feet (50% of maximum footcandle level). CB=Distance across or down to center beam location. 0 L D W FC W CB L LIT-2069 06/15/18 Page 9 of 1 Amerlux, LLC 178 Bauer Drive, Oakland, NJ 0746 P: 97-882-5010 F: 97-882-25 amerlux.com

Essenza Square Lens Wall Wash: FIXTURE DATA: (Complete photometric data (.ies format) available upon request) 18W LED, 000K-+ Lens Wall Wash (RLW) Distribution LTL #11627794 Lumens: 515 MULTIPLYING FACTORS: (Multiplying Factor is based on 000K-97 120V IES file on website) Wattage: 12W 18W Factor: 0.84 1.0 CCT: 2700K-8 000K-8 500K-8 4000K-8 Factor: 1.16 1.20 1.2 1.25 CCT: 2200K-+ 2700K-+ 000K-+ 500K-+ 4000K-+ CRISP CLA Factor: 0.85 0.96 1.0 1.05 1.08 0.79 0. 50 100 150 200 ZONAL LUMEN SUMMARY Zone Lumens %Fixt 0-40 255 49.5 0-429 8. 0-515 100.0-180 0 0.0 Luminaire Efficacy: 0. lumens/watt Application Data: Footcandles on Wall Footcandles are average and rounded off. Data for multiple units are based on a minimum of five units. 1.5 Feet From Wall 1.5 1.5 1.5 Feet From Wall 2 2 Distance from ceiling 0.5 26 27 29 27 26 1.5 42 44 46 44 42 2.5 26 29 0 29 26.5 16 18 18 18 16 4.5 10 11 11 11 10 5.5 7 8 8 8 7 6.5 5 5 6 5 5 7.5 4 4 4 4 4 Distance from ceiling 0.5 18 24 19 24 19 24 18 1.5 2 5 4 6 4 5 2 2.5 21 2 2 24 2 2 21.5 1 14 15 15 15 14 1 4.5 8 9 10 10 10 9 8 5.5 6 6 7 7 7 6 6 6.5 4 5 5 5 5 5 4 7.5 4 4 4 4 4 4 4 2 Feet From Wall 2 2 Distance from ceiling 0.5 11 12 12 12 12 12 12 1.5 22 24 24 24 24 24 22 2.5 20 22 22 2 22 22 20.5 14 15 16 16 16 16 14 4.5 10 11 11 11 11 11 10 5.5 7 8 8 8 8 8 7 6.5 5 6 6 6 6 6 5 7.5 4 4 5 5 5 5 4 LIT-2069 06/15/18 Page 10 of 1 Amerlux, LLC 178 Bauer Drive, Oakland, NJ 0746 P: 97-882-5010 F: 97-882-25 amerlux.com

Essenza Square Shower: FIXTURE DATA: (Complete photometric data (.ies format) available upon request) MULTIPLYING FACTORS: (Multiplying Factor is based on 000K-97 120V IES file on website) Wattage: 12W 18W Factor: 0.84 1.0 CCT: 2700K-8 000K-8 500K-8 4000K-8 Factor: 1.16 1.20 1.2 1.25 CCT: 2200K-+ 2700K-+ 000K-+ 500K-+ 4000K-+ CRISP CLA Factor: 0.85 0.96 1.0 1.05 1.08 0.79 0. 18W LED, 000K-+ Spot (SP) Distribution LTL #116295 Lumens: 92.8 Flood (FL) Distribution LTL # 11627996 Lumens: 872.8 Wide Flood (WF) Distribution LTL # 11628097 Lumens: 866. Very Wide Flood (VWF) Distribution LTL # 116298 Lumens: 87.5 1250 500 1 500 2500 1000 50 1000 0 1500 525 5000 2000 1500 700 0 5257 5 4419 15 154 25 2 5 70 26 0 21 5 200 15 1206 25 465 5 1 51 0 1651 5 1584 15 10 25 497 5 181 64 0 727 5 725 15 656 25 504 5 295 124 Application Data: 0 o Aiming Angle Horizontal Footcandles Spot Flood Wide Flood Very Wide Flood 5.0 211 1.7 1.7 7.5 94 2.8 2.7 10.0 5.6.4 12.5 4 4.5 4. 5.0 86 2.8 2.7 7.5 8 4.1.9 10.0 22 5.5 5. 12.5 14 6.9 6.6 5.0 66.1.1 7.5 0 4.6 4.6 10.0 17 6.1 6.1 12.5 11 7.7 7.7 5.0 29 4.8 4.9 7.5 1 7.2 7.4 10.0 7 9.7 9.9 12.5 5 12.4 12.7 W D L FC Notes and Definitions: Beam spread is to 50% center beam candlepower (CBCP). D=Distance to floor or wall. FC=Footcandles on floor or wall at center beam aiming location. L=Effective Visual Beam length in feet (50% of maximum footcandle level). W=Effective Visual Beam width in feet (50% of maximum footcandle level). CB=Distance across or down to center beam location. LIT-2069 06/15/18 Page 11 of 1 Amerlux, LLC 178 Bauer Drive, Oakland, NJ 0746 P: 97-882-5010 F: 97-882-25 amerlux.com

DIMMING COMPATIBILITY: Amerlux Essenza fixtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general compatibilities and wiring diagrams. Amerlux recommends testing your unique dimming configuration as the exact full configuration (Dimmer, Fixture Quantity, Voltage, etc) may affect dimming performance. --- NOTE: INFORMATION BELOW IS FOR WIRED DIMMERS ONLY. FOR WIRELESS DIMMERS, CONSULT FACTORY --- TRIAC (Forward Phase) DIMMING (Standard) Utilizes Standard incandescent dimmers that are in wide use in installations across the US. Best for retrofit applications where TRIAC dimmers are installed. Notes: 120V or 277V* Dims down to less than 5% light output (most cases) Consult Dimming manufacturer for installation instructions - DO NOT SHARE NEUTRALS! Must meet dimmer Minimum Load Requirements per dimming manufacturer Compatible Dimmers Wall Box (Incandescent Style, Wattage as required) Lutron Diva Lutron Vareo Lutron Nova-T Lutron Skylark Lutron Maestro TRIAC Wiring Diagram TRIAC Dimming Control Central System Lutron GP Panel Lutron Grafik Eye QS White Green Driver V+ V- Red ELV - Electronic Low Voltage (Reverse Phase) DIMMING (Standard) Utilizes specialized ELV dimmers. Best for New Construction applications ELV Wiring Diagram Notes: 120V or 277V* Dims down to less than 5% light output (most cases) ELV Dimming Consult Dimming manufacturer for installation Control instructions - DO NOT SHARE NEUTRALS! Must meet dimmer Minimum Load Requirements Compatible Dimmers Wall Box (ELV Style) Lutron Diva Lutron Nova-T Lutron Maestro Leviton Surslide Lutron Vareo Lutron Skylark Leviton Vizio White Green Central System Lutron GP Panel with PHPM-PA Interface Lutron Grafik Eye QS with PHPM-PA Interface Driver V+ V- Red 0-10V - DIMMING (-0-10V Option) Integrates into a variety of building management and daylighting controls 0-10V Wiring Diagram Notes: 120V or 277V* Dims down to 1% light output Requires interface to turn off power to driver Consult Dimming manufacturer for installation instructions - DO NOT SHARE NEUTRALS! 0-10V Dimming Control Gray Purple White Green Driver 0-10V (-) 0-10V (+) Switched Hot V+ V- Red Compatible Dimmers Wall Box Lutron Diva - DVTV with PP- 120H Interface Leviton Renoir II 0-10v Central System Lutron Grafik Eye with GRX-TVI Interface Notes: * Driver is 277V dimmable with appropriate dimmer (by others). All provided wiring diagrams show 120V wiring colors and method. Please refer to 277V dimming installation instructions for 277V wiring diagrams. LIT-2069 06/15/18 Page 12 of 1 Amerlux, LLC 178 Bauer Drive, Oakland, NJ 0746 P: 97-882-5010 F: 97-882-25 amerlux.com

DIMMING COMPATIBILITY: Amerlux Essenza fixtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general compatibilities and wiring diagrams. Amerlux recommends testing your unique dimming configuration as the exact full configuration (Dimmer, Fixture Quantity, Voltage, etc) may affect dimming performance. --- NOTE: INFORMATION BELOW IS FOR WIRED DIMMERS ONLY. FOR WIRELESS DIMMERS, CONSULT FACTORY --- LUTRON A-SERIES HI-LUME / ECOSYSTEM (-DIM-HILUME Option) Integrates into Lutron EcoSystem building management -Wire Wiring Diagram Notes: 120V or 277V* Dims down to less than 5% light output May use -Wire or EcoSystem Control Consult Dimming manufacturer for installation instructions - DO NOT SHARE NEUTRALS! Cap unused ECOSYS wires -Wire Phase Dimming Control Purple Stripe Purple Orange White Green E1 E2 Driver Dimmed Hot Switched Hot V+ V- Red Compatible Dimmers Wall Box (-Wire Fluorescent) DIVA Maestro Nova T Vareo Central System Lutron EcoSystem compatible controls EcoSystem Digital Control Wiring Diagram E2 E1 ECOSYS Bus EcoSystem Dimming Purple Stripe E1 Driver Control Purple E2 (Cap off Orange wire) Orange Dimmed Hot Switched Hot White Green V+ V- Red Notes: * Driver is 277V dimmable with appropriate dimmer (by others). All provided wiring diagrams show 120V wiring colors and method. Please refer to 277V dimming installation instructions for 277V wiring diagrams. LIT-2069 06/15/18 Page 1 of 1 Amerlux, LLC 178 Bauer Drive, Oakland, NJ 0746 P: 97-882-5010 F: 97-882-25 amerlux.com