HALCO PRODUCTS COMPANY

Similar documents
Air Showers The Safety Solution for Animal Research Laboratories. Viva Air Shower, Model - EAS-1B.

Cleanroom Air Showers

CLEAR ROOM EQUIPMENT CLEAR ROOM EQUIPMENT AIR SHOWER PRESSURE RELIEF DAMPER PASS BOX PASS THOUGH CLEAN BENCH VERTICAL CLEAN BENCH HORIZONTAL

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.

CLEAN AIR SYSTEM.

SOLUTIONS TO STATIC PROBLEMS

Biosafety Cabinets and Fume Hoods Supplemental Material (OHS_BIO304)

Clean Air Products 90-Degree Low Profile Left Hand ADA Compliant Air Shower Purchase Specification

AIR SHOWERS CAP701 SERIES

STANDARD OPERATING PROCEDURE 1/1/07 DYCEM HOUSEKEEPING Medical Devices and Terminal Sterilized Pharmaceutical Products

Air Shower TECHNICAL DATA

DATA & FACTS Clean Rooms DencoHappel Air Shower. Active Air Shower for Personnel in Clean Rooms

Clean Bench Animal Transfer Stations

LAMINAR FLOW FOR ALL YOUR NEEDS

Integrated System Selection and Design

Safe Operating Procedure (Revised 2/10)

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

Fume Hood Safety TYPES OF FUME HOODS

Survey Says: Clean for Safety and Profitability

DRYAIR Turnkey Dry Room Standards

TRION Air Purification systems

OPERATION AND MAINTENANCE MANUAL

POST-CLEANING PROCESSES. Precision Drying Completes Precision Cleaning BY DANIEL J. VANDERPYL AND KIRK MCGLOTHLAN

I Love My Job I Love The People I Hate The Dust

AES Environmental. Operation and maintenance manual. VWS Series. Laminar Vertical Flow clean work station

Desiccants & Driers. By Norm Christopherson

Design Specifications for Panda 900A Car Spray Booth

Understanding of Surface Heat Tracing of Bulk Storage Tanks for Viscous and High Pour Point Fluids - By, H. R. Mullan

A Feasibility Study of Replacing Manual Dishwashing with a Mechanical Dishwasher at Taco Bell

Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings

Pharmaceutical Facility Design

Quick Reference Guide to Cabinet types

Animal Tissue Culture SQG 3242 Equipment and Lab design. Dr. SITI PAULIENA MOHD BOHARI

systemräume Gaining space for man and technology CLEAN ROOMS AND CONTROLLED ZONES

LABGARD NU-602 CLASS II TYPE A2 ANIMAL HANDLING BIOLOGICAL SAFETY CABINET

ZERO Economy Blast Cabinets

BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class

Biological Safety Cabinets. Presented by Mr. Rene Soetens President

BARRIER TECHNOLOGY RABS & ISOLATORS FOR ASEPTIC PROCESSING

DGH Series Global Air Treatment

PART III. Laboratory equipment

Desiccant Breathers: A Front Line Defense in the War on Contamination

TECCON. 2,5 to 10,0 t / H Water evaporation RATE

Class II Biosafety Cabinets

Biological Safety Cabinets or Fume Hoods Which one to use?

CIRCULAIRE LAMINAR AIR FLOW

Air Shower with Integrated Air Handling Unit

How to comply with CDC Guidelines

LABORATORY CABINETS 103

Hybrid Refrigerated/Desiccant Compressed Air Dryers

Time and water efficiency in tank cleaning

Armstrong Cool-Fog Systems

AIRWORTHINESS ADVISORY CIRCULAR

Guidelines for Ideal Layout for an Operating Theater Complex. Dr.R.D.Ravindran Aravind Eye Hospital Madurai

CLEACOM Engineered System Solutions. Established 24/7 technology for the separation of dust and fume during compounding processes

General Purpose Laminar Flow Cabinets, Horizontal and Vertical. Horizontal Flow Vertical Flow

Discover the Difference

Coal Handling and Processing. Advanced Solutions for Coal-Related Environmental Dust Control. Better Air is Our Business

PRODUCT OVERVIEW. or other secondary operations using a high velocity, high impact air stream.

NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet

IVF/ART Series Laminar Flow Cabinets

How about Savings in Time, Money, Energy and Longer Life?

Research Document Type: PROCEDURE. Effective Date: January 01,2015 Author Steven Hayes

Lead Safety for Renovation, Repair, and Painting. Requirements in the EPA RRP Rule:

TYPICAL CPA SPECIFICATIONS

LASER SAFETY. Class 2 and 2a - low power, low risk Class 2 and 2a lasers have low power and emit visible light. They will cause harm if viewed

Dust Collection Tips to Keep Free-From Foods Safe from Cross-Contamination

Airblast Tech Tips Grit Recycling Systems - common questions and answers

WHITE PAPER The Importance of Rinsing in Metal Finishing Operations

Product Selection Guide

BHC. Replacing Air Sparging Agitation Increases Cleaning Efficiency in Immersion/Soak Tank Degreasing BHC WHITE PAPER

Biological Safety Cabinet

Efficient Vacuum Conveyors Deliver Cost-Effective Solutions Pick-up, conveying and feeding of powders, granules and other bulk materials

Installation & Maintenance Instructions

OPERATION & MAINTENANCE MANUAL MODEL SC-924A SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

Vacuum - The Universal Conveying Force Suction and transportation of powders, liquids and gases

Breezair RPA Series Installation Manual

QAQC LABS ANALYTICAL DRYING

Appendix A.4.1. Safe Fume Hood User Guide

P3X Series Membrane dryers

M 115 M 150 M 150 A M 130 M 180 M 180 A SERIE. Undercounter dishwashers Vegetable washers. Glasswashers. Pass through. dishwashers.

Factory & Hospital hygiene, Chap 21(7 th edition) Principles of GMP, Chap 23 (8 th edition )

Environmental Health and Safety Biological Safety Program Guidance Document

Exploring Vacuum Technology in Pharmaceutical Processing FDA Eases-the-Way for Processors to Automate Processing Lines with Safer, Faster and

Is Your Ultrasonic Cleaning System Living Up to Its Potential?

Flexible Solutions for Air Quality

HOW TO SELECT AN INDIRECT THERMAL TECHNOLOGY FOR INDUSTRIAL MATERIALS PROCESSING

Underfloor Air Systems. How It s Different: Overhead vs. Underfloor Air Systems

CDT Series MCGUIRE AIR COMPRESSORS INC MCGUIRE AIR COMPRESSORS INC Heatless Desiccant Air Dryers 40 5,400 SCfm

CLEAN AIR SYSTEMS DIVISION. An ISO 9001 Certified Company. Nan Technical Trading W.L.L P.O.Box Manama Kingdom of Bahrain

PG 8535 Perfect Reprocessing

ACORE Filtration Co.,Ltd provides engineering,

Safe Use of a Class II Biological Safety Cabinet

IRRIGATION EQUIPMENT LTD. The Perfect Solution for Water Filtration and Irrigation Problems

Filtrex A Smoke Detector for Difficult Environments

Faster UltraSafe Class II Microbiological Safety Cabinets. Protection, safety, reliability. And more.

5.0 Installation Instructions

Air Purification Systems. Clearing the Air. Air Purification Systems. Air Purification Systems

Transcription:

AIR SHOWER AND AIR SHOWER TUNNELS 9/3/2010 STANDARDS AND QUALIFICATIONS AIR SHOWERS- ARE THEY WORTH THE COST? DO THEY REALLY REDUCE CONTAMINATION? CAN THEY BE COST JUSTIFIED? The efficacy of air showers in the contamination control process has been a source of debate for several years. Tests have been conducted which prove the effectiveness of air showers. The tests do show that an air shower does reduce particulate. For the most part, reduction in particulate matter is dependent upon the particle size, the type of garment worn, the cycle time, and directly relates to the air shower design and how it is used and maintained. DOES THE USE OF AN AIR SHOWER JUSTIFY ITS COST?: As a percentage of the total cost of the modern clean room, the cost of an air shower is virtually insignificant. In any application where contamination is critically important such as life science, biomedical, pharmaceutical, parenteral drug, microelectronics, aerospace and precision manufacturing air showers should be considered essential equipment. If its use could eliminate contamination of one expensive batch of pharmaceutical chemicals or the rejection of one semiconductor wafer, for example, it is money well spent. Perhaps millions of dollars could be saved. In addition, from a psychological point of view, having operating personnel pass through an air shower before entering the work area, reinforces the fact that cleanliness to the operation is essential. This, hopefully, reinforces the concept that protection of the product from personnel is a significant concern. A BRIEF HISTORY OF THE EMERGENCE OF CONTAMINATION CONTROL TECHNOLOGY: In today's modern world of manufacturing and research and development, contamination control technology has become a necessary part of the manufacturing process. In fact, without it, many of the advances made in the last twenty years or so would not have been possible. Contamination control technology is not confined to any one industry. Its practice transcends specific industries and is used, to some degree, in just about all manufacturing and research and development processes.

Without contamination control technology, the developing broad field of life sciences encompassing biotech, biomedical, pharmaceutical, parenteral drug, microelectronics, aerospace and precision manufacturing would not have been able to achieve some of the discoveries that have been made to date nor the discoveries yet to be made. While nanotechnology, a new emerging field of study in which is research done at the atomic or molecular level, could not exist without the advancements made in contamination control technology over the years. Dealing with the issues of contamination control on a microscopic or smaller scale has led to the creation of the modern clean room and along with it, the air shower. The primary focus of a clean room is to control the levels of contamination by creating a differential pressure between the clean room and the surrounding area and to filter the air entering the room to prevent the entry of unwanted particulate matter and to change the air in the room with an air-handling system to purge particulate matter created within the room. The clean room itself is constructed of materials that tend to resist particle generation, hence minimizing additional contamination. More sophisticated clean rooms can also control temperature and humidity in the workspace. In the conventional clean room, low velocity air enters from the ceiling plenum through perforated diffusers and carries out contamination through wall exhausts close to floor level. In the laminar flow clean room, air is introduced uniformly at low velocities into a space confined on four sides and through an opening equal to the cross sectional area of the confined space - a technique that stratifies the air and minimizes cross-stream contamination. To keep this particulate matter from being recycled, both types of rooms use HEPA (high efficiency particulate air) filters. HEPA filters are manufactured from glass fiber, accordion-style pleated filters that can be up to 99.99% efficient in removing particles 0.3 microns and larger. For more stringent requirements, an ULPA (ultra low particulate air filter) filter may be used. An ULPA filter has the ability to remove a higher percentage of 0.3 micron particles than a HEPA filter. CONTAMINATION VS. PARTICULATE MATTER: So far in this discussion the terms "particulate matter" and "contamination" have been used interchangeably. A contaminate is any foreign substance that will have a detrimental effect on whatever you are trying to accomplish. The most significant form of contamination in clean rooms is submicroscopic matter that are distributed in the air in the form of fine particles or fibers or carried into the clean room and re-deposited by workers. To be technically correct, however, it should be pointed out that not all particulate matter is a contaminant. To be considered a contaminant, particulate matter must meet three criteria:

1. It must be able to migrate to the vulnerable area, either by air currents, by fluids, or through transference from of personnel. 2. It must be significant in number. 3. It must have physical properties that can cause damage. SOURCES OF CONTAMINATION ARE EVERYWHERE: Just about all industrial activities produce contaminates. Operating personnel present the most significant source of contaminates - hair, skin, dandruff as well as oral and nasal emissions - to name a few. While contaminants can and do differ in terms of hardness, size, shape, translucency, color, etc., their size, in most cases, determines the degree of potential harm they can cause. There is a very delicate balance between the contamination level, the number of personnel in a clean room and how they go about performing their assigned tasks. Some contamination is inevitable. In reality, there is very little you can do about this natural propensity to create contaminants except to instruct workers in correct clean room procedure and to deal with the unavoidable contamination as it arises. This is what clean rooms have always done. You can certainly help matters by limiting the amount of contaminants that any specific individual brings in from the outside. AN AIR SHOWER CAN BE AN INTEGRAL PART OF THE CONTAMINATION CONTROL PROCESS BECAUSE IT CAN MINIMIZE THE AMOUNT OF CONTAMINANTS BROUGHT INTO THE CLEAN ROOM FROM THE OUTSIDE: An air shower is nothing more than a device meant to limit the contamination brought into a controlled area such as a clean room. It works by moving air over the worker at a specific high velocity for a specified period of time. In a properly designed air shower, particles are driven off and away from the body and deposited on the upstream side of the HEPA or ULPA filters. Air Showers have been used effectively in the clean room industry for over thirty-five (35) years and have been instrumental in reducing the level of contamination brought into the clean room. Normally positioned between the clean room and the outside environment, an air shower is a chamber equipped with a blower unit, interlocking doors, HEPA filters and prefilters, a recirculating air system and multiple air nozzles. Various size nozzles are arranged on the walls and ceiling in a predetermined pattern for the most effective removal of loose particles, dust, or other particulate matter from the garments. Filtered air is blown through the nozzles directly against the individual standing within the air shower, creating a flapping and shearing effect designed to remove loose contaminants prior to entering a change room, wash room, ante-room or clean room. The air is sucked taken from the chamber, stripped of its contaminants through the filtration system, and recycled back to the air shower to continue the cleaning job. Today's air shower is equipped with a powerful blower unit, solid state electrical control panels complete with safety monitors and emergency shut-down capabilities that may be activated from both the interior and exterior of the unit. Fluorescent lighting is flush ceiling mounted for maximum brightness. IS THERE A DIFFERENCE BETWEEN AN AIR SHOWERS AND AN AIR LOCK?:

An air shower is usually built into an air lock. It is important to remember that there is a big difference between the two. An air lock is a room, corridor or some other space which separates the clean room from a less clean area. Generally, it has two (2) doors at opposite ends and is frequently designed with an electrical or mechanical interlock so that one door cannot be opened unless the other one is closed. Its purpose is to prevent the loss of valuable clean room air whenever a person leaves or enters the room and also to prevent contaminated air from entering the clean room when a door is opened. It also has the ability to conserve energy. While an air shower can function in this capacity, it also has the additional advantage of being able to actively clean off contamination from the person entering the clean room with jets of filtered air coming out of the nozzles. HOW DOES AN AIR SHOWER OPERATE?: Typically an air shower can be operated in three (3) distinctly different ways depending on process requirements: 1. One way 2. Two way, one way 3. Two way ONE WAY OPERATION: Exit door locked at rest, entrance door unlocked. When the user enters the air shower, the entrance door closes and locks; then the air shower cycle starts. At the end of the cycle, the entrance door stays locked and the exit door unlocks so that the user can leave. When the exit door is closed, it locks again and the entrance door unlocks. The air shower is now ready for use again. TWO WAY, ONE WAY OPERATION: The air shower is used in both directions, but operates the air shower in only one direction. Only one door at a time can be opened. Both doors are unlocked at rest. The user enters the air shower via the entrance door. At the end of the air shower cycle, he leaves via the exit door. Or a user can enter the unit via the exit door once the exit door closes the user can immediately leave via the entrance door without activation the cycle. Both doors cannot be open at the same time. TWO WAY OPERATION: In this mode, the cycle runs in both directions. Only one door at a time can be opened. The user can go in in either direction and the air shower will cycle.

Test data has been obtained which prove that air showers are effective in reducing contamination brought into the clean room. Data developed by a Japanese company several years ago indicates that, depending upon the particle size, particle removal can be up to 90%. The larger the particle, the higher the efficiency, as illustrated in the accompanying chart: It is to be noted that proper operating protocol in using an air shower weighs greatly on its effectiveness. Training is of utmost importance to insure reduced contamination levels in clean rooms and to ensure that the air shower is operating at maximum effectiveness. Proper protocol suggests personnel should be trained to rotate continuously 360 degrees, with hands on their heads as illustrated during the air shower cycle to insure contamination removal is as efficient as possible. The Air Force has very exacting standards regarding acceptable levels of contamination while at the same time, has equally exacting standards when it comes to investing in equipment. In order to determine the efficacy of air showers the Air Force conducted tests of its own. The test consisted of sending a team of twenty (20) operating personnel through two (2) air showers, one located before the entrance to the change room and the other before the entrance to the clean room itself with a cycle time of eight (8) seconds each. Operators were instructed to raise their arms and make a 360º turn. Prior to the entrance to the first air shower, outer garments are removed and stored. Once past the first air shower, the individual enters the change room where he puts on the clean room garments and goes through the second air shower, entering the clean room. After each test condition, the clean room was allowed to return to the normal contaminant level before a new test was begun and collections of samples were made. TEST 1 BOTH AIR SHOWERS OFF 94,990 PARTICLES BASE READING TEST 2 FIRST ON, SECOND OFF 52,920 PARTICLES 44%REDUCTION TEST 3 SECOND ON, FIRST OFF 37,100 PARTICLES 61%REDUCTION TEST 4 BOTH ON 19,290 PARTICLES 80%REDUCTION All samples are taken from inside the clean room and 0.5 micron particles are measured As can be seen, the level of contamination removal was at least 44% with at least one air shower in operation. With two (2) air showers in operation, contamination removal was 80%. Further independent testing on the type of material workers are clothed in demonstrates that what the worker wears can make a significant difference in the amount of particulate removed by the air shower as indicated in the chart below:

TODAY'S AIR SHOWERS CAN KEEP A SIGNIFICANT AMOUNT OF RESIDUAL CONTAMINATION FROM ENTERING A CLEAN ROOM WORKPLACE AS LONG AS CERTAIN CRITERIA ARE MET: 1. The air shower must be properly designed and sized to maintain effective and efficient operations. 2. At a minimum, HEPA filters are 99.99% efficient at 0.3 microns or optional ULPA filter at 99.999% efficient at 0.12 microns. 3. Sufficient "wash down time" - at least 45 seconds - must be allowed in the air shower. 4. The air supplied to the shower must be finely filtered to prevent personnel from being impinged with contaminants during the actual cleaning cycle. 5. A fixed nozzle pattern must be followed and the nozzles must be preset to direct air in a downward flow to produce shearing, wash down effect. It is essential to have a fluttering of garments strong enough to loosen dust. 6. The garments themselves must be made of material such as Tyvek, teflon, dacron or nylon that is less likely to shed than cloth; comfort and cost must not be the determining factor. 7. The air shower must operate at a negative pressure. In other words, the pressure in the air shower must not exceed the pressure outside. The pressure must be less than the clean room side to prevent contaminates. 8. Very importantly, personnel must act responsibly, i.e., when they stand off-center or crouch in a corner to avoid the air flow, they are defeating the whole purpose of the air shower. The individual must center himself in the shower and execute several complete 360º turns during the 45 second duration of the air shower, with hands positioned over the head. 9. The individual must remain in the air shower for several moments as specified in the company's protocol after it has stopped to allow enough "purge time," or "dwell time" so that the particles may drift downward through the floor grate and are not drawn into the clean room by the movement of the individual as he leaves the air shower. 10. Air showers, like clean rooms or for that matter any process equipment, must be properly maintained in order to function properly. Lack of proper maintenance can become a major source of contamination.