USER MANUAL 10 YEAR LIFE SMOKE ALARM

NG-9B NATURAL GAS ALARM

LOW FREQUENCY SOUNDER

COMBINED STROBE & VIBRATING PAD

Wireless Interlink Smoke Alarm + 10 Year Life

Installation and User Guide

7 YEAR LIFE CARBON MONOXIDE POISONOUS GAS ALARM

10 YEAR LIFE SMOKE ALARM 10 YEAR LIFE TOAST PROOF SMOKE ALARM

CO-9X User Manual 6 YEAR LIFE CARBON MONOXIDE POISONOUS GAS ALARM

CO-808S User Manual. Carbon Monoxide Poisonous Gas Alarm With Sealed 6 Year Power Pack

U S E R M A N U A L UBH1RF HEAT ALARM

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

DIGITAL 7 YEAR LIFE CARBON MONOXIDE ALARM

WIRELESS INTERLINK SMOKE ALARM + 10 YEAR LIFE WST-630

WBS-616 User Manual. Wi-Safe Remote Warning Handset Part of the Wi-Safe Home Safety System

DIGITAL 7 YEAR LIFE CARBON MONOXIDE ALARM (Includes all colour variants)

SI-610 / SO-610 User Manual. 10 Year Smoke Alarm Standard / Toast Proof with Smart Silence

Carbon Monoxide Room Alarm Installation and User Guide Part No:

LSI-601 / LSO-601 User Manual. Smoke Alarm Standard / Toast Proof with Ultra Bright Escape Light

ESCAPE LIGHT SMOKE ALARM LSI-601 ESCAPE LIGHT TOAST PROOF SMOKE ALARM LSO-601

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

MOTORCYCLE RADAR & LASER DETECTION SYSTEM TPX VISUAL ALERT MANUAL

aquamanta the experts in aquatic technology CH 025/050/100/ 150/200/300 NEW PHOTO Instruction Manual

Document No

MariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120.

OPERATING MANUAL. The Guardian Hand Held Security Metal Detector

OWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ.

Owner s Manual. PIR-1 IR Learner

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

Towel Warmer MAKE EVERYDAY A SPA DAY

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual

OWNERS MANUAL MODEL 451 (-101 & -201)

USER GUIDE. Metal Ceramic Heater NS-HTMCSL6. Before using your new product, please read these instructions to prevent any damage.

Towel Warmer. Luxurious warmth for towels, robes and blankets

Projection Alarm Clock USER GUIDE

OPERATING MANUAL. The Guardian Hand Held Security Metal Detector

User Guide. for the Beacon ProActTM 200 System

Mold Alert... Operation Manual P0270

Spa Control System OWNER S MANUAL

OPEARATING GUIDELINES FOR AERO-252 (Pages 1 to 3 contain general information on CO Guardian. Pages 4 to 6 contain information specific to Aero 252)

1.5 L Electric Kettle

Air Pump Up to 800 gallons

ion Genesis Pump Controller

For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked.

RR-PM1200 OPERATING AND PROGRAMMING GUIDE

LIFETONE HL TM. Bedside Fire Alarm & Clock. User s Manual MODEL HLAC XI. RECOMMENDED LOCATIONS FOR SMOKE ALARMS ENGLISH SPANISH

Warranty. Thanks. Thank you for purchasing the Oliso Smart Iron, a safer, smarter way to iron.

Steam Bug. World's smallest steam iron great for travel

Installation and Operation Instructions Luxury Towel Warmer Free Standing or Wall Mounted

LGR Dehumidifier Owner s Manual

Wireless Base Remote Test and Hush

VersaBrew SINGLE SERVE COFFEE MAKER USER GUIDE

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

Instruction Leaflet. Read instructions before operating. Retain for future reference.

Carbon Monoxide Alarms for Boats

Operation & Installation Guide

MiniSkim. Inspiring Excellence in Fish Keeping! Instruction version: 17/08/2012.

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR)

pure indoor living Remote Control TOWER FAN MODEL: BTF4011AR-CN

USER GUIDE. Ceramic Tower Heater NS-HTTCBK6. Before using your new product, please read these instructions to prevent any damage.

User Manual. Juice Extractor MODEL: WJE2BSLA

Model: Ei450. Instruction Manual

AUTOMATIC SWINGING DOOR

2-Slice Toaster Instruction Manual. Styled for Life Designed & Engineered in New York City

hot air popcorn popper

- User Brochure tekmarnet 4 Setpoint Control 161

M113S Users Manual. MERLIN STEALTH M113S Electric Fence Energizer GROUP OF COMPANIES. PDF created with pdffactory trial version

SAFETY & SECURITY SAFETY & SECURITY

Compact Fabric Steamer

User Manual. Wine Cellar

DIGITAL STEEL FIRE & SECURITY

Family size Glasstop warming tray WITH TEMPERATURE CONTROL

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Remote Vehicle Control System

Table of Contents Welcome and Thank You Note:

Twin Bell Digital Clock

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

Installation Instructions / Warranty. Starck 10111XX XX XX1

- User Brochure Programmable Thermostat 510

User s Manual For Model Aero-551 (Rev. Orig.)

Smoke Alarm User Manual

Infrared quartz heater

EVEN SEAR MULTI GRILL INSTRUCTION MANUAL MODEL: CKCLIG1

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

2-in-1 Corded Stick Vacuum Cleaner

RF Modules for Battery Powered Smoke & Heat Alarms Ei600 Series

Shiatsu Neck and Shoulder Massager KNEADING MASSAGE FOR HARD-TO-REACH MUSCLES

Cellular Alarm Quick Start Installation Guide

INSTALLATION AND OPERATION INSTRUCTIONS

Dome Kettle. polished stainless steel body BTDK120

GREEK FRO-YO MAKER. instruction manual & recipe guide

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

Full Extension Soft-Close Undermount Drawer Slide

Pressurized Filter Up to 1250 gallons

OWNER S MANUAL. CoolTower CTF07. (English) (CTF07)

HIGH VOLTAGE A.C. PROXIMITY DETECTOR HI-PROX

Auto/Air Power Adapter for Dell Quick Installation Guide

Installation and Servicing Instructions

Transcription:

Connevans.info Solutions to improve the quality of life Offering you choice Helping you choose This product may be purchased from Connevans Limited secure online store at www.deafequipment.co.uk DeafEquipment.co.uk

CDA-9X User Manual GN0469/R2 COLD ALARM Raising the alarm when the temperature drops. Technical Support Line 0800 141 2561 Email info@fireangel.co.uk Web www.fireangel.co.uk Sprue Safety Products Ltd. Vanguard Centre Sir William Lyons Road Coventry CV4 7EZ UK

CONTENTS INTRODUCTION INSTALLATION PRODUCT ACTIVATION UNDERSTANDING YOUR COLD ALARM TESTING YOUR ALARM ERROR / LOW POWER PACK WARNING TECHNICAL INFORMATION 4 7 8 9 13 15 17 2

FURTHER INFORMATION WARRANTY RETURNS DISPOSAL 18 19 23 25 Note: This User Manual is also available in large text and other formats. Please call 0800 141 2561 for further information 3

INTRODUCTION Congratulations! You ve made a wise investment in an innovative product and your personal safety. The CDA-9X Cold alarm is one of a new generation of domestic life safety products from FireAngel Limited, which combines the latest technology and innovative design to provide an aesthetically pleasing and effective contribution to your home safety. The FireAngel range of products is constantly being improved and expanded. Please visit www.fireangel.co.uk to find out about the latest additions to our product range. 4

During an average winter, more than 25,000 people die as a result of cold weather in the UK and Ireland. Extremely cold weather can cause mild hypothermia, which increases the risks of some illnesses including heart attacks, strokes and respiratory disease and the likelihood of falls. Cold weather and poorly heated homes constitute a severe risk to health, particularly the elderly, the infirm and the very young. This FireAngel Cold Alarm will warn you when the temperature of the room in which the alarm is installed is falling to a dangerously low level. The alarm should provoke 5

you to concentrate heating in a single room, to move to a warmer area or to seek outside help before hypothermia or worse occurs! 6

INSTALLATION The cold alarm can be wall mounted using the screw and screw anchor provided or it can be free standing on a hard flat surface. We recommend it is installed in an area where you spend most time. Keep the alarm away from drafts, direct sunshine and direct heat sources. The alarm is portable. 7

PRODUCT ACTIVATION OFF ON Your cold alarm is powered by a sealed power pack which will provide power for the lifetime of the product which is estimated at 10 years. To activate the alarm simply switch the alarm on by sliding the switch on the side of the alarm to the ON position. When the alarm is switched on all 3 LEDs will flash briefly and the alarm will chirp once. 8

UNDERSTANDING YOUR COLD ALARM The Power LED will flash green once per minute to indicate that the alarm is switched on. Power Warning Alarm Your cold alarm is designed to give a series of visual and audible warnings when the temperature falls. If only the Power LED is flashing 9

once per minute then the temperature in the room is 18 C or above. Other temperatures below this will result in one of the following indications: Warning: The Warning LED will flash Yellow once every 5 seconds when the temperature is 12 C or above and less than18 C. There is a potential risk of ill health. Danger: The Alarm LED will flash Red once every 5 seconds and the alarm will sound briefly every 2 minutes when the temperature is 7 C or above and less than12 C. The temperature in the room is far too low. This temperature range 10

can lead to hypothermia. There is a high risk of ill health. Critical: The Alarm LED will flash Red every second and the alarm will repeatedly sound for 30 seconds followed by a break of 30 seconds when the temperature is below 7 C. The temperature in the room is dangerously cold. Should any of these indications occur you should take steps to increase the temperature, or if this is not possible try to make yourself warmer. When the alarm indicates Danger or Critical temperature ranges it is 11

possible to temporarily silence the alarm for 30 minutes. This will allow for any measures you have taken to increase the temperature in the room to take effect. If the temperature continues to fall significantly the alarm will exit silence mode. NORMAL WARNING DANGER CRITICAL 18 C and above 17 C 16 C 15 C 14 C 13 C 12 C 11 C 10 C 9 C 8 C 7 C 6 C and below 12

TESTING YOUR ALARM Test the sounder, power pack and circuitry by pressing and releasing the Test/Silence button to confirm that the detector is operating properly. 13

The sounder should sound as soon as the button is pressed, and the Alarm LED will illuminate red indicating that the sounder is working and the power pack is providing power to the unit. This test for the sounder, battery and circuitry should be performed on a weekly basis. 14

ERROR / LOW POWER PACK WARNING The alarm regularly carries out a series of checks on it s circuitry and power pack. If the alarm detects an error or if the power pack level is low the alarm will emit a single chirp once every minute and all three LEDs will flash together once every minute. If the unit is still within warranty contact the FireAngel helpdesk on 0800 141 2561. If the product is out of warranty replace immediately with a comparable product. 15

CAUTION: Your FireAngel Cold Alarm is a sealed electrical device and no attempt should be made to open the case. Attempting to open the case will invalidate your warranty. WARNING: DO NOT ATTEMPT TO OPEN - DO NOT BURN 16

TECHNICAL INFORMATION Model CDA-9X Power Pack Life Estimated 10 years (Life of product) Operating Temperature Range -10ºC (14ºF) to 40ºC (104ºF) Operating Humidity Range 30-90% RH (relative humidity) Weight (inc. batteries) 60 grams (2.1oz) Dimensions W 93mm x H 65mm x D 28mm 17

FURTHER INFORMATION The FireAngel Cold Alarm, is designed to offer an early warning of unhealthy, low indoor temperatures. It will not prevent ill health due to low indoor temperatures. It will however, alert you to low indoor temperatures in order that you can take steps to improve your environment. Neither the manufacturer, nor the supplier, nor other retailers can be held responsible for ill health or death from cold related illnesses. 18

WARRANTY Sprue Safety Products Ltd warrants to the original purchaser that its enclosed CDA-9X Cold Alarm be free from defects in materials and workmanship under normal residential use and service for a period of 1 (one) year from the date of purchase. Provided it is returned with postage prepaid and proof of purchase, Sprue Safety Products Ltd hereby warrants that during the 1 (one) year period commencing from the date of purchase Sprue Safety Products Ltd, at its discretion, agrees to replace the unit free of charge. The warranty on 19

any replacement FireAngel CDA-9X Cold Alarm will last for the remainder of the period of the original warranty in respect of the detector originally purchased that is from the date of original purchase and not from the date of receipt of the replacement product. Sprue Safety Products Ltd reserves the right to offer an alternative product similar to that being replaced if the original model is no longer available or in stock. This warranty applies to the original retail purchaser from the date of original retail purchase and is not transferable. Proof of purchase is required. 20

Warranty disclaimers This warranty does not cover damage resulting from accident, misuse, disassembly, abuse or lack of reasonable care of the product, or applications not in accordance with the user manual. It does not cover events and conditions outside of Sprue Safety Products Ltd s control, such as Acts of God (fire, severe weather etc). It does not apply to retail stores, service centres or any distributors or agents. Sprue Safety Products Ltd will not recognise any changes to this warranty by third parties. Sprue Safety Products Ltd shall not be liable for any incidental 21

or consequential damages caused by the breach of any expressed or implied warranty. Except to the extent prohibited by applicable law, any implied warranty of merchantability or fitness for a particular purpose is limited in duration to 1 (one) year. This warranty does not affect your statutory rights. Sprue Safety Products Ltd shall not be liable for any loss of use, damage, cost or expense relating to this product or for any indirect, or consequential loss, damages or costs incurred by you or any other user of this product. 22

RETURNS We recommend that you contact the FireAngel Technical Support Line in the first instance on 0800 141 2561, text phone users dial 18001 0800 141 2561 or callers from EIRE dial 1-800 523171 as we may be able to remedy the problem quickly over the phone (this is to prevent unnecessary returns that take a longer time to process). Alternatively e-mail: technicalsupport@fireangel.co.uk If there is a fault that we are unable to resolve then our technical support team member will provide you with a returns authority number so that your 23

product can be returned for testing. To return your FireAngel CDA-9X under warranty, send it suitably packed and switched off with postage prepaid; a note indicating the returns authority number and describing the reason for return, with proof of purchase to: Sprue Safety Products Ltd Vanguard Centre Sir William Lyons Road Coventry, CV4 7EZ UK 24

DISPOSAL Waste electrical products should not be disposed of with regular household waste. Please recycle where facilities exist. Check with your local authority, retailer or the FireAngel Technical Support Line (see page 23 for contact details) for recycling/disposal advice as regional variations apply. You can also return your cold alarm to us for disposal. For return address see the section on Returns. Please include a note confirming the product is being returned for disposal. 25