SI 1082 o Monobloc pump for air conditioners up to 10 kw

Similar documents
SI 3080 / SI 3100 / SI 3200

condensate pumps For air conditioning and refrigeration technology eckerle.com

EVAPORATIVE COOLER PUMPS

Condensate water pumps

Condensate removal pumps

Condensate removal pumps

Mini Condensate Pumps

product guide The most complete range of ancillary essentials designed specifically for the HVAC/R industry

ASPEN CANADA. Available From:

EMI ENGINEERING SUBMITTAL

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

EMI ENGINEERING SUBMITTAL

Warewash systems. innovation > technology > future

HCompact2 HA. Compact air-air stand-alone units. Compact horizontal Reduced dimensions Centrifugal fans RANGE DESCRIPTION OPERATING LIMITS SERIES

HT V2 HT Split

DAZZLE TM series Cassette Type Fan Coil Unit. FC-NHDU4 Cassette Type Fan Coil Unit 340~2380 m 3 /h

THE CARRIER COMFORT LINE

PARTS BOOK. From S/N:

ICC COOLING STORAGE UNIT ICC/ICU SYSTEM

Industrial cooling systems LT

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP


Technical Specification l Peristaltic Pumps Standard Part No: FP2081/2

ROOFTOP PACKAGED AIR CONDITIONERS

High temperature air-to-water heat pumps

160 Line. 1 Door Undercounter Refrigerator (+2/+10) - UK Plug. 160 Line

Product Catalog. Condensate Removal Ice Machine Replacement Evaporative Cooler Accessories. Engineered Products HVAC. Industrial

MINI BENCH TOP CHAMBER MODEL: MI-80-A-H

technical data Fan coil unit FWB small duct unit

Product Data Sheet Refrigerant Dryer DFLO-ES 66 (-W) to DFLO-ES 660 (-W) with energy saving management

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Aquair BCP. Pool air handling units. Electronic Control Optimized energy consumption DESCRIPTION PRINCIPLE SCHEMES RANGE OPERATING LIMITS

APPLICATION GUIDE FLATAIR FMC - H FIC - H FSC - H. Horizontal packaged air conditioners kw FLATAIR AGU-MSL E. lennoxemeia.

Conditioning your ambient, maximising your comfort.

Operation manual SOL-TEC - SL

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

FX BLAST CHILLER ISO ISO 9001

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC

HEAT PUMPS. Efficient Comfort For Every Season

Product Data Sheet Refrigeration Dryer DFLO 66 (-W) bis DFLO 2400 (-W)

NEW INTELLIGENT AIR TECHNOLOGY

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

SECTION WATER-SOURCE UNITARY HEAT PUMPS

User s Manual. THE iq Drive SYSTEM USER S INFORMATION IMPORTANT. Variable Speed Ultra-High SEER Split System IMPORTANT NOTE

Conditioning your ambient, maximising your comfort.

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

HVS, Hydro Variable System Air cooled chiller

Cold water HD 9/18-4 ST


Mini Split Condensate Pump

Honeywell Portable Air Conditioners. A compact, easy to use portable cooling solution.

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

MULTI-INVERTER AIR CONDITIONERS

Air Conditioner SVC MANUAL(Exploded View)

Technical Data Ducted Three Phase Split System Air Conditioner

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

PARTS BOOK. From S/N:

USER S MANUAL AND INSTALLATION INSTRUCTIONS IMPORTANT

Laboratory glassware. > washing system. devoted to hygiene. For the Environmentally conscious

APPLICATION GUIDE DUCTABLE FANCOIL ARIA 2. 1,3-6,6 kw ARIA2-AGU-1610-E.

Just feel well. 2017/2018 Air conditioning

Residential and Light Commercial Ductless Systems Catalog

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

Warewash Systems. innovation > technology > future

CHAPTER 6 CONDENSING UNITS

Applications Damage service Building drying Water works Dry storing FEATURES

Product Line Introduction. Karl Zhang Technical support engineer

Self-Contained & Split System Reverse Cycle Air Conditioners Models

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

FRAL SRL via dell industria e dell artigianato, 22/C Carmignano di Brenta - PADOVA - ITALY

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

Laboratory glassware. > washing system. devoted to hygiene. For the Environmentally conscious

Self-Contained Reverse Cycle Air Conditioners

CENTRAL SPLIT UNIT UNIC

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

Multi Split Systems. Reverse Cycle, Inverter Air Conditioner. Exclusively distributed by

R 407 C. > in industrial application. Always very much appreciated for special installations these units shown their powers :

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

innovation > technology > future

SHAKING WATER BATHS ENGLISH

Dosing systems for dishwashing machines TWINDOSE SERIES

ADSORPTION DRYERS. For all applications which require perfectly dry compressed air : Advantages of "ALC" dryers :

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

SMC DUCTED. High Performance AIR CONDITIONING SYSTEMS

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

A single answer for multiple zones.

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

Refrigeration pumps FOR THE RETAIL INDUSTRY

Condensate Drain Valves

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

Transcription:

SI 1082 o Monobloc pump for air conditioners up to 10 kw Anti-vibration mount included Integral quick / connector plug AIR CONDITIONING Maximum recommended discharge height Max flow rate 8 l/h 6 m 10 W 230V~ 50/60Hz NC 8 A resistive - 250V Thermal protection (overheat) 90 C Detection unit integrated Detection levels On:18mm Off:12mm Al:21mm Protection IP 54 Sound level 28 dba at 1 m 02 HIGH COMPETITIVE Dimensions in mm L W H Pump 66 44 77 Monobloc condensate pump integrating the float sensor, specifically designed for air conditioning units with limited internal space. Low noise: 28 dba Lowered installation inside the drain inlet: less microbs, germs. Low Maintenance Design: pump with 2.5mm ID section + duck valve to enable to pass small particules specifically designed condensate inlet - decanter for heavy & metallic parts - pins for long particules (hair, copper wires,...) - no fi lter = no clogging IP54 pump: the pump is protected against water drops (ex: condensation on the tubing) WALL MOUNTED SYSTEMS Fan-coil Floor split systems Wall split systems CEILING MOUNTED SYSTEMS Ceiling suspended units Ducted units RECOMMANDED ACCESSORIES ACC 00105 / ACC 00150 / ACC 00151 ACC 00205 ACC 00208 ACC 00209 Clear tubing Ø 6 mm int. ACC 00105 : 5 m in blister pack ACC 00150 : in 50 m roll ACC 00151 : reinforced 50 m roll 6 self-sealing fi ttings for condensate removal. Rubber elbow 90 15 x 15 mm. «S» type rubber hose 15 x 15 mm with a 4 mn offset to empty the drain pan. THE RANGE OF CONDENSATE REMOVAL PUMPS

SI 3080 / SI 3100 / SI 3200 Mini pumps for air conditioners up to 10 kw (SI 3080 & SI 3100) and up to 20 kw (SI 3200) SILENCIEUSES SILENT s o Integral quick / connector plug AIR CONDITIONING Anti-vibration mount SI 3080 SI 3100 SI 3200 Max flow rate 8 l/h 10 l/h 20 l/h Max suction head 1 m 2 m 6 m 10 W 18 W 230 V~ 50/60 Hz NC 8 A resistive 250V Thermal protection (overheat) 90 C Sound level (at 1 m) 28 dba 30 dba 34 dba Maximum recommended discharge height Dimensions in mm L W H Pump unit 66 44 59 Detection unit 55 38 32 This range of mini pumps is designed to meet the most exacting requirements in practical ease of installation, performance and quiet, reliable operation. Each consisting in a separate pump unit and fl uid sensor, their reduced size makes them ideal for the very limited internal space afforded by most air conditioning units. Low noise pump: 28 dba (SI 3080) 03 WALL MOUNTED SYSTEMS Split units Floor console units Fan-coil units CEILING MOUNTED SYSTEMS Ceiling suspended units Ducted systems Fan-coil units ACC 00105 / ACC 00150 / ACC 00151 Clear tubing 6 mm int. ACC 00105 : 5 m in blister pack ACC 00150 : in 50 m roll ACC 00151 : reinforced 50 m roll ACC 00205 6 self-sealing fi ttings for condensate removal.

SI 1730 Condensate removal pump for air conditioners up to 30 kw x AIR CONDITIONING Integral quick / connector Included Max flow rate 30 l/hr Max suction head 2,5 m 10 m 35 W 230 V~ 50/60 Hz NO - NC 8 A resistive Thermal protection (overheat) 90 C Sound level at 1 m 42 dba Dimensions in mm L W H Pump unit 74 52 95 Detection unit 55 40 35 Maximum recommended discharge height POWERFUL The SI 1730 is a new generation pump with both high capacity (30 l/hr) and great ease of installation due to its reduced size and its integral quick connector. It is designed for high power wall mounted, ceiling mounted, ducted and fl oor mounted air conditioning units. 05 s WALL MOUNTED SYSTEMS Column split systems Floor split systems Air handling units CEILING MOUNTED SYSTEMS Ceiling suspended units Cassette units ACC 00105 / ACC 00150 / ACC 00151 Clear tubing Ø 6 mm int. ACC 00105 : 5 m ACC 00150 : 50 m roll ACC 00151 : reinforcing 50 m roll ACC 00205 6 self sealing fi ttings for condensate removal. ACC 17010 In line fi lter

EE 1650 x Monobloc piston tank pump for air conditioners up to 30 kw AIR CONDITIONING MULTI-USE Max flow rate 30 l/hr 13 m 35 W 230 V~ 50/60 Hz NC 8 A resistive Thermal protection (overheat) 90 C Sound level at 1 m 52 dba Dimensions in mm L W H Pump unit 160 85 88 The EE 1650 monobloc piston 0.5 l tank pump, with a condensate pumping capacity of 30 l/hr, is designed for high power air conditioning systems with or without condensate collection trays. Furthermore, it s design enables it to sit either under or inside the condensate collection tray. 06 WALL MOUNTED SYSTEMS Floor mounted units Column air conditioning units Fan-coils CEILING MOUNTED SYSTEMS Multicassette installations ACC 00105 / ACC 00150 / ACC 00151 Clear tubing Ø 6 mm int. ACC 00105 : 5 m ACC 00150 : 50 m roll ACC 00151 : reinforcing 50 m roll ACC 00205 6 self sealing fi ttings for condensate removal THE RANGE OF CONDENSATE REMOVAL PUMPS

SI 1800 Tank pump h AIR CONDITIONING HEATING REFRIGERATION Max flow rate Thermal protection (overheat) Water levels Sound level at 1 m 300 l/hr 4,7 m 70 W 230V~ 50 Hz NC 4 A resistive - 250 V 105 C On=40mm, Off=28mm, Alarm=66mm 54 dba Dimensions in mm L W H Tank capacity Pump 283 127 161 2 l DYNAMIC Centrifugal pump for heavy and contaminated condensates, suitable for mild acid and hot condensates (65 C max). normally closed that automatically cuts off the air conditioning system compressor or a solenoid valve. Integrated check valve. Integrated 2.0 l tank. 07 s Laboratory evaporators Display cabinets Cold store evaporator Column units Ducted units Multi-cassettes Condensing Boilers High effi ciency Gas furnace ACC 00110 ACC 00125 / ACC 00126 ACC 00225 / ACC 00230 / ACC 00240 ACC 00601 Special install kit: 1 X ACC 00225, 1 X ACC 00230, 1 X ACC 00240 Clear tubing Ø 10 mm ACC 00125 : 25 m roll ACC 00126 : reinforcing 25 m roll Individual adapters ACC 00225 : 1, Ø 25 mm ACC 00230 : 1 1/4, Ø 32 mm ACC 00240 : 1 1/2, Ø 40 mm Float unit to trigger alarm or manage pump operation

SI 1805 / SI 1820 Tank pumps h for air conditioners, refrigeration units and condensing boilers. AIR CONDITIONING HEATING REFRIGERATION SI 1805 SI 1820 SI 1805 SI 1820 Max flow rate 500 l/hr 5,4 m 90 W 230 V~ 50/60 Hz NC 4 A resistive - 250 V Thermal protection (overheat) 130 C High temperature and acid condensate 80 C, Ph > 3,4 Water levels in mm On = 24 Off = 13 Alarm = 30 Sound level at 1 m 47 dba On = 43 Off = 27 Alarm = 67 STATE OF THE ART Dimensions in mm L W H Tank capacity SI 1805 195 130 122 0,5 l SI 1820 195 130 170 2,0 l High capacity Impeller Tank Pumps designed to collect and remove heavy condensates from refrigeration display cases and air conditioning systems and condensing boilers, with or without condensate drain pans. 08 WALL MOUNTED SYSTEMS Column air conditioning units Refrigerated display cabinets Refrigeration units Condensing boilers CEILING MOUNTED SYSTEMS Multicassette installations Evaporators ACC 00110 ACC 00125 / ACC 00126 ACC 00225 / ACC 00230 / ACC 00240 ACC 00601 Special install kit: 1 X ACC 00225, 1 X ACC 00230, 1 X ACC 00240 Clear tubing Ø 10 mm ACC 00125 : 25 m roll ACC 00126 : reinforcing 25 m roll Individual adapters ACC 00225 : 1, Ø 25 mm ACC 00230 : 1 1/4, Ø 32 mm ACC 00240 : 1 1/2, Ø 40 mm Float unit to trigger alarm or manage pump operation THE RANGE OF CONDENSATE REMOVAL PUMPS

SI 1822 / SI 1850 Tank pumps for heavy duty and contaminated condensates h AIR CONDITIONING HEATING REFRIGERATION SI 1850 SI 1822 SI 1850 Max flow rate 380 l/hr 1100 l/hr 6,2 m 11 m 90 W 325 W 230V~ 50 Hz NC 4 A resistive - 250 V Thermal protection (overheat) 105 C 135 C Water levels On=75mm, Off=20mm, Alarm=90mm On=70mm, Off=20mm, Alarm=95mm Sound level at 1 m 47 dba 66 dba SI 1822 Dimensions in mm L W H Tank capacity SI 1822 305 152 235 3,8 l SI 1850 305 152 257 3,8 l HEAT RESISTING Centrifugal pump for heavy duty and contaminated condensates Suitable for mild acid and hot condensates (65 C max for SI 1822 and 87 C max for SI 1850) Big volume 3.8 l tank normally closed that automatically cuts off the air conditioning system compressor or a solenoid valve. Integrated check valve 09 s Laboratory evaporators Display cabinets Cold store evaporator Column units Ducted units Multi-cassettes Condensing Boilers High effi ciency Gas furnace ACC 00110 ACC 00125 / ACC 00126 ACC 00225 / ACC 00230 / ACC 00240 ACC 00601 Special install kit: 1 X ACC 00225, 1 X ACC 00230, 1 X ACC 00240 Clear tubing Ø 10 mm ACC 00125 : 25 m roll ACC 00126 : reinforcing 25 m roll Individual adapters ACC 00225 : 1, Ø 25 mm ACC 00230 : 1 1/4, Ø 32 mm ACC 00240 : 1 1/2, Ø 40 mm Float unit to trigger alarm or manage pump operation

PE 5000 / PE 5100 / PE 5200 j P e r i s t a l t i c p u m p s AIR CONDITIONING REFRIGERATION PE 5000 PE 5100 PE 5200 Max flow rate 6 l/hr Max suction head 2 m 12 m 11 W 230 V~ 50/60 Hz NC 8 A resistif Protection IP 65 Sound level at 1 m 30 dba RESISTANTE Dimensions in mm L W H Pump unit 109 110 91 Detection unit PE 5200 only 55 38 32 10 Peristaltic pumps are designed for those applications requiring removal of heavy or charged condensates. Their compact design make them particularly suitable for applications up to 8 kw nominal cooling capacity. PE 5000: Operates on 240V cooling signal PE 5100: Operates on temperature differential PE 5200: Operates off the remote fl oat sensor unit (SI2858 included) WALL MOUNTED SYSTEMS Split units Refrigerated displays Fan-coil units CEILING MOUNTED SYSTEMS Ceiling suspended units Evaporator units Fan-coil units ACC 00205 ACC 00601 PE 5001 PE 5002 6 self sealing fi ttings for condensate removal. Float unit to trigger alarm or manage pump operation. Replacement pump head unit for all PE5000, PE5100 and PE5200 pumps. Replacement tube unit for all PE5000, PE5100 and PE5200 pumps. THE RANGE OF CONDENSATE REMOVAL PUMPS

PE 6000 DOSING / PE 6250 HIGH FLOW Peristaltic pumps j AIR CONDITIONING REFRIGERATION PE 6000 PE 6250 Max flow rate 1,5 l/hr 25 l/hr Max suction head 2 m 15 m 10 m 3,5 W 66 W 230 V~ 50/60 Hz Timer (intervals of) from 2 to 18 mn - Clock (daily programmable) increments of 15 mn - Max ambient temperature 50 C Protection - IP 65 Dimensions in mm L W H Pump PE 6000 167 116 213 Pump PE 6250 134 171 282 PE 6000 PE 6250 s PE 6250 PE 6000 PERISTALTIC DOSING PUMP (anti-legionella, algae, ) EFFICIENT & PREVENTIVE: The PE 6000 peristaltic pump is used for injecting detergent or disinfectant* (not included) in order to fi ght the spread of diseases (legionella) or the formation of algae in cooling towers. PROGRAMMABLE: Pump comes equipped with integral timer and clock. PE 6250 HIGH FLOW PERISTALTIC PUMP for air conditioners up to 25 kw HIGH FLOW: The very high capacity of the PE 6250 pump and its 10 mm discharge tube enable removal of heavy condensate if required. 11 * The amount and frequency of injections can be programmed with the timer and clock provided on the front and must be in accordance with the detergent and/or disinfectant manufactures recommendations. PE 6000 Cooling towers PE 6250 WALL MOUNTED SYSTEMS CEILING MOUNTED SYSTEMS Large split units Ceiling suspended units Refrigerated displays Evaporator units Fan-coil units Fan-coil units ACC 00601 Float unit to trigger alarm or manage pump operation. ACC 00125 / ACC 00126 Clear tubing Ø 10 mm ACC 00125 : 25 m roll ACC 00126 : reinforcing 25 m roll

B ACCESSORIES* REFERENCES DESCRIPTION ACC 00106 Blond rubber 50 cm for SI 2750 / SI 3080 / SI 3100 / SI 3200 / SI 1730 ACC 00201 Adapter kit Ø 17 / Ø 22 mm. ACC 00202 Adapter kit Ø 17 / Ø 32 mm. ACC 00203 Restriction Ø 17 / Ø 32 mm for flow reduction.. ACC 00204 5 straight connectors Ø 6 mm + 5 elbows Ø 6 mm. ACC 00211 5 T connector Ø 6 mm. ACC 00401 Priming squeezie bottle allowing pump to be tested without dismantling unit. ACC 00501 10 double side adhesive tape. ACC 00703 3 m extension cable for SI 2750 / SI 3080 / SI 3100 / SI 3200 / SI 1730 ACC 00705 5 m extension cable for SI 2750 / SI 3080 / SI 3100 / SI 3200 / SI 1730 ACC 00208 90 elbow, 15 x 15 mm. ACC 00209 Flexible coupling 15 x 15 mm, allows complete emptying of condensate tray. ACC 00210 90 elbow 17 x 15 mm. ACC 00805 5 Check valve for 6 mm tube. www.sauermannpumps.com * Accessories are only guaranteed for the applications for which they are advertized. SAUERMANN FRANCE Parc d activités de l Orée de Chevry Route de Férolles 77173 CHEVRY COSSIGNY Tel. : (+33) 01 60 62 06 06 Fax : (+33) 01 60 62 09 09 E-mail: info@sauermann.fr SAUERMANN ITALIA S.R.L. Via Umbria 11/17 40060 OSTERIA GRANDE (BO) Tél. : (+39) 051/6958400 Fax : (+39) 051/6958609 E-mail: info@sauermann.it Shanghaï SAUERMANN Co. Ltd. 155 Zhangpu Road JuYuan Development Park - JiaDing District Shanghai 200182 - P.R. CHINA Tel. : (+ 86) 21 691 689 61 Fax : (+ 86) 21 691 689 62 www.sauermann.com.cn PENÍNSULA IBÉRICA Avda, del Encinar, 1 Urb. Fuente del Fresno 28708 SAN SEBASTIAN DE LOS REYES (Madrid) ESPANA Tél. : (+34) 91 623 64 42 Fax : (+34) 91 623 64 34 E-mail: busslinger@telefonica.net SAUERMANN UK Limited PO Box 187 - Lytham St Annes FY8 4WN - U.K. Tel. : (+44) 0 870 950 6378 Fax : (+44) 0 870 950 6379 E-mail: sales@sauermann-uk.com SAUERMANN GmbH Kernerstrasse 18 D-74223 FLEIN Fon : (+49) 07131/399990 Fax : (+49) 07131/399992 E-mail: Sauermann-Flein@t-online.de SAUERMANN N.A. Corp. 6020 Jean-Talon East, suite 804 Montréal QUEBEC H1S 3B1 CANADA Tel. : (+1) 514 284-4948 Fax : (+1) 514 284-4940 E-mail: ads@sympatico.ca SCANDINAVIA, BALTICS, RUSSIA & EUROPEAN EASTERN COUNTRIES Parkgade 8 6440 AUGUSTENBORG DENMARK Tlf. : (+45) 74 47 10 78 Mobil : (+45) 40 59 10 78 E-mail: peter.remontius@get2net.dk DOC UK 000/5-02/05-20 000 EX