heat interface units A BOILER WITHOUT A FLAME

Similar documents
Hot Water Energy Storage THE HOT WATER PEOPLE HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY

heat interface units A BOILER WITHOUT A FLAME HIU Single PHE options

Instructions for installing and using HIPER HIU UK patent applied for:

T. +44 (0) E.

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

T. +44 (0) E.

ModuSat TP. Energy. Heat Interface Units

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

ModuSat TP. Energy. Heat Interface Units

SATK 30 heat interface unit

INSTALLATION AND SERVICING

GIACOMINI HEAT INTERFACE UNITS

Herz York Direct Heat Interface Unit

Logic+ Combi

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

Sirius FS. Working towards a cleaner future

The iqe Boiler Range. Combination and System T Boilers.

Where gas is not an option,

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

NEW BUILD YOUR COMPLETE SOLUTION.

The Ultimate Solution for Electric Central Heating. Fusion. Comet

THERMAL INTERFACE UNITS. Designed and manufactured in the UK. Designed for performance

Contact person Date Reference Page Björn Folkeson P (14) Energy and bioeconomy

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

USERS GUIDE. LOGIC+ Combi 24, 30, 35

SUPERIOR QUALITY HEAT INTERFACE UNITS PUTTING YOU IN CONTROL. Pegler Yorkshire

Stored Water District Heating Interface Units. Heat Interface Units

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

INDEPENDENT COMBINATION & SYSTEM BOILERS.

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents

USERS GUIDE 24, 30. For installation guide see reverse of book

Armstrong Flo-H2O Water to Water Instantaneous Heater Installation and Maintenance & Operation

B-40/B-41 Modulating Temperature Controller

Contact person Date Reference Page Daniel Månsson P07886B-rev2 1 (14) Energy and bioeconomy

WATER-TUBE POOL HEATERS

Project Name: Location: Engineer: Contractor: I. GENERAL

IDEAL LOGIC HEAT INTERFACE UNITS (HIUs) PRODUCT GUIDE.

SATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE

ir-range 8G /03.15 Changes reserved.

Warmth, efficiency, and total peace of mind.

THE REMEHA HIU RANGE Installation, operation and maintenance manual December 2017

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

Sirius WH. Working towards a cleaner future

- Data Brochure Universal Reset Module 422

Installation, Operation and Maintenance Instructions Thermaflow E Plate Heat Exchanger Package OM013

Contact person Date Reference Page Daniel Månsson P07886C-rev2 1 (14) Energy and bioeconomy

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Metering systems 0548EN April 2014

prestige Control Application Supplement - TriMax

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

Bosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function

WATER-TUBE POOL HEATERS

R-SERIES kW YEAR ROUND MAXIMUM CONDENSING BOILER. burning diesel oil, kerosene, natural gas or liquid petroleum gas

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

USER GUIDE VOGUE MAX SYSTEM

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet:

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

EasiHeat Mechanical Installation and Commissioning Instructions

Gas-Fired Condensing Boilers A Green Start To Space & Water Heating

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

- Data Brochure Boiler Control 274

Quickheat 30 weather compensated boiler control

Installation and Servicing Instructions. Alpha FlowSmart

FASTflo. Working towards a cleaner future

Control Application. Supplement - ACVMax

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

Underfloor heating. user guide. DS thermostats with timeclock. Nu-Heat v18 UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

System Design for efficiency using electronic, intelligent HIU s. Neil Parry CIBSE Accredited Heat Network Consultant

Linea HE. High efficiency combi boiler. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Heat Interface Units for decentralised water heating in district heating systems

Contact person Date Reference Page Daniel Månsson P07886E-rev2 1 (14) Energy and bioeconomy

- Data Brochure Universal Reset Module 423

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

UK arotherm Schematics and installation guide

HW 22 District heating substation for indirect heating and domestic hot water systems

High Output Boiler Systems

AFUE 95% Heating Input 50,000 to 200,000 Btuh

Multi Boiler Guide. Kit #

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for vented systems.

CS027 User Instructions

RF Programmable Room Thermostat User Instructions

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

prestige Control Application Supplement - ACVMax

STREBEL S-CB + Cascade Kits

Meibes Heat Interface Unit (HIU) A2RXE Instantaneous Hot Water & Space Heating

Fitting & Commissioning Instructions. EcoBlue Combi and System Range. Outdoor Sensor Kit. Kit Part No (System) Kit Part No.

Transcription:

A BOILER WITHOUT A FLAME

heat interface units Communal Heat Networks A central boiler house will generate heat which is distributed through a network of pipe to each home or apartment in the building. Each home or apartment has its own HIU (heat interface unit), which converts heat from the network as heating and hot water for the home. Advantages for Designers, Developers and Architects Gas supply not required for an HIU No flues to evacuate exhaust combustion No storage cylinder required Meets low emission and efficiency targets Advantages for the installers Easy to install, add only a programmable room thermostat Compact and lightweight Minimal installation requirements for pipe work. Simple maintenance and easy access to all components Advantages for Landlords Reduced service and maintenance costs Metered energy usage for fairer tenant billing Practical for combining with lower cost renewable technologies No flues to maintain for health and safety laws Advantages for the Tenant Shared maintenance costs Efficiently controlled heating and hot water supply Accurate billing for only the actual energy used Awareness of energy consumption promotes energy saving

Heat Interface Unit The Hiper HIU is compact and requires very little space and is easy to install. The design meets all varying demands of the home. It is, in many ways like a combi boiler, providing central heating and instantaneous hot water, but without flame or flue. Energy efficient Instantaneous hot water production Electronic temperature control Optimised heating temperature control as standard Standby mode temperature control Lower return temperatures to the network Low carbon heat networks - renewable energy sources Weather compensation option Low energy pump Radiators or underfloor heating Minimal maintenance reducing running costs Hiper HIU range Hiper Xi45 INDIRECT HIU 45DHW/10HTG Part Code : HIPER4510 Hiper Xi60 INDIRECT HIU 60DHW/10HTG Part Code : HIPER6010 Hiper Xi60L INDIRECT HIU 60DHW/15HTG Part Code : HIPER6015 Hiper Xi70 INDIRECT HIU 70DHW/15HTG Part Code : HIPER7015

Dimensions

internal schematic. 1 2 7 9 3 Cold water mains District (Primary) RETURN 6 8 15 3 3A DHW Supply 3A District (Primary) FLOW 4A 4 12 11 13 10 5 16 14 SV Discharge Pipe 3 Central Heating RETURN Central Heating 3 Central Heating FLOW 1 Electronic PID Controller 2. Room Thermostat (not supplied) 3. Isolation valves (Secondary side) 3A Isolation valves (District side) 4. PICV (Pressure Independent Control valve) 4A PICV Actuator with step motor 5 Circulating Pump for the central heating 6 3 port Diverting Valve 7 DHW Plate Heat Exchanger 8 DHW temperature sensor 9 Flow switch 10 Central Heating Flow temperature sensor 11 Central Heating Return temperature sensor 12 Central Heating Plate Heat Exchanger 13 Pressure Switch 14 Safety Valve 15 Filling Loop Connection 16 Pressure Gauge

Description - Hiper Indirect HIU Two plate heat exchangers (PHE) one for heating (CH) and one for hot water (DHWS). The electronics provide PROPORTIONAL reactive control to demand. PID electronic controller Integral PICV (Pressure Independent Control Valve) Maximum efficiency with lowest return temperatures back into the network. Safety with high temperature limits enforced even without an electricity supply Systems can be designed with little requirement for expensive commissioning. Simple to maintain, the plate heat exchangers can be accessed and removed in just minutes. Insulated with a tamperproof steel casing. Plate Heat Exchangers access from the front Wilo low energy pump, fixed or variable speed Automatic air vent 3 bar safety relief valve on the secondary heating side 3 drain points Large surface area strainer mesh for extended maintenance schedules Sealed system heating Thermostatic high temperature protection Flat face union, 3/4 connections A B PROPORTIONAL control. A proportional control system is not simply turning the CH and DHWS on and off, it feeds in the supply from the District side in proportion to the demand. This gives stable hot water supply temperatures, even at very low demands. The heating is similarly controlled for efficiency, as the room warms up the controller starts to lower the amount of heat being allowed into the PHE supplying the central heating always maintaining minimum energy usage. Temperature and flow sensors in the unit send constant information back to the PID control unit which in turn signals the PICV to modulate as required to meet the demand and maintain temperature stability. A - PICV with electronic modulating actuator B - Diverting valve Design and Construction The unit is designed for the plate heat exchangers to be at the front for easy access. These are mounted onto purpose made brass blocks which contain the integral waterways and component connection points. Inter-connecting pipework is kept to a minimum.

Hiper HIU FEATURES PID Control Unit (Proportional-Integral-Derivative) maintains the efficiency of the HIU. Provide stable temperatures under varying load conditions. Unique algorithms constantly recalculate the amount and the speed of modulation required for maximum efficiency. Pressure Independent Control integral PICV with electric actuator giving proportional modulating control as instructed by the PID Controller, 100% authority, (regardless of pressure fluctuations in the district heating supply). Unlike many other HIU, no further control valves (for example DPCV) are required. Anti-Scale Control in the DHW PHE - the flow is always diverted away from the DHW PHE into the HTG PHE reducing the scale formation potential. Automatic Fault Diagnostics The control unit can identify faults to components within the HIU and issues an identifying fault code on the screen. Once the fault or error has been rectified the control unit automatically resets and resumes normal operation. Heating Flow Automatic Limitation - decreasing the possibility of starving the DH circuit when extreme demands are made on the entire network. For example in cold weather when a large heating demand is made on the network the control unit does not allow 100% opening on start up and prevents the over demand causing disruptions. Instant Hot Water Response - Instant water response is guaranteed by keeping heat (supplied by the district supply) close at hand to the HIU at all times. At regular intervals (factory set to 20 minutes), the controller opens (factory set to 2 min) the PICV to deliver a low flow of about 100 l/hr, then closes the valve again. This repeats whenever the HIU is on standby when there is no demand. Optimised Heating Control - return temperatures are monitored and controlled. The controller of the HIU uses this information to maintain the optimum flow temperature and keep the DISTRICT return temperature as low as possible. This can be seen on the display screen as AUTO and is the factory setting. DHWS Priority - DHWS is the priority operation of the HIU. A flow switch detects the demand and the HIU (if in heating mode) switches to DHW production. Even if the heating system is in fault mode, the HIU will still produce DHWS. High DHW temperature safety. If for whatever reason un-managed hot water at extreme temperature were to pass through the PHE, there is a thermostatic limiting valve on the DHW exit. This is locked and factory set to 60C. Being non electric this still maintains the safety feature even when electric supply to the HIU is cut. Proven reliable components. Low energy Erp compliant pump. Unique inlet Block with By Pass, test points, meter sensor port and uniquely design strainer with increase surface area for longer duty without blocking or reduced performance over a standard pattern Y Strainer.

The Hiper HIU FEATURES Low & High Pressure protection for the HIU. Low pressure switch will stop the circulating pump should the secondary system drop below 0.7 Bar. The HIU is fitted with a Safety Relief valve set at 3 bar for high pressure protection. Underfloor Heating - the unit is fully compatible with low temperature systems. The installer simply sets the required value for temperature on installation. Full detail available in the installation manual. Insulation - the HIU panels are all fully insulated including the back-plate to prevent overheating of the surrounding area. Prepayment Billing can be accommodated with an accessory kit to shut down the unit when the tenant is no longer in credit. Security - the metal casing can be closed to prevent unauthorised tampering with optional fixing bolts on request. HIU Hibernation mode - press the start button and hold for 3 seconds and the HIU will shut-down. The PICV valve will shut, and heating, hot water and standby functions will be disabled. Press the start button to resume normal operation. This is a function for when the apartment is unoccupied or for the tenant during holiday periods. PROVEN PERFORMANCE. The HIPER HIU has been independently tested and proved conforms to BS EN13203-01 BS EN13203-01is the British Standard for; Gas fired domestic appliances producing hot water Appliances not exceeding 70 kw heat input and 300 ltr water storage capacity Part 1, assessment of performance of hot water deliveries, The HIU was tested, awarded 2 Stars, and measured on delivery of DHW at 55C, with a DH flow temp of 70C. Further details and copy test report available to all qualified enquiries.

components 2 1 16 3 15 14 4 13 5 6 7 8 12 11 10 9 10 11 1 Electronic PID Controller 2 District connection block inc. strainer 3. PICV (behind the controller) 4 Central Heating Plate Heat Exchanger 5 DHW Plate Heat Exchanger 6 Automatic Air vent 7 Circulating Pump for the central heating 8 Safety Valve 9 Pressure gauge 10 Flow switch 11 Filling Loop connection 12 Thermostatic High Temp. Limit Valve 13 Expansion Vessel 14 Diverting valve 15 Spacer for installation of Heat meter 16 Bypass valve

Operation 1 Switch on the Power supply When powered up for the first time, the controller goes through a diagnostics check of the HIU. This may last a few seconds and the display shows as above a timed out rotating symbol. If a problem is detected the controller will display an ERROR symbol. (see installer or user guide for full details. 1 2 3 HIU is now on stand-by. Having completed its checks, the controller is now ready to operate. Until a demand is created it remains in standby mode. Turn on a hot water tap The hot water temperature is factory set to the industry recommended temperature of 55 C. Once the HIU controller senses water flow it will commence the production of hot water immediately, and stabilise at the set temperature Turn the tap off (no demand for hot water) The screen will show the stand by symbol. Room thermostat calls for heating.. The HIU now operates in heating mode, and the screen shows the set flow temperature. Any demand for hot water will take priority Factory settings DHWS at 55C Central Heating at 60C

HIU - Technical Specification for Hiper Xi45 and Xi60 Technical Parameters Xi45 Xi60 PRIMARY (heat supply from communal heat source) 16 bar 16 bar MAXIMUM PRESSURE PRIMARY (heat supply from communal heat source) 90 C 90 C MAXIMUM TEMPERATURE PRIMARY (heat supply from communal heat source) 4 bar 4 bar MAXIMUM pressure differential SECONDARY (central heating circuit in the flat, apartment or house) 3 bar 3 bar MAXIMUM PRESSURE SECONDARY (central heating circuit in the flat, apartment or house) 85 C 85 C MAXIMUM TEMPERATURE SECONDARY (central heating circuit in the flat, apartment or house) 20 C to 85 C 20 C to 85 C TEMPERATURE ADJUSTMENT SECONDARY (central heating circuit in the flat, apartment or house) HEATING 10 Kw 10 Kw OUTPUT DOMESTIC HOT WATER (including cold water supply main) 10 bar 10 bar MAXIMUM PRESSURE DOMESTIC HOT WATER 60 C 60 C MAXIMUM TEMPERATURE LIMITED by TMV DOMESTIC HOT WATER 30 C to 65 C 30 C to 65 C TEMPERATURE ADJUSTMENT DOMESTIC HOT WATER OUTPUT 45kW 60kW Designed for easy access to all components. Plate Heat Exchangers are secured by four bolts all directly accessible easily front the front. Both PHE can be removed and exchanged in minutes Both PHE removed.

Docherty Group Unit C, Fairview Buildings Heage Road Industrial Estate Ripley, DE5 3GH T: 01773 571 330 E: sales@adinaheating.co.uk