PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED

Similar documents
PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED

CFAA Technical Seminar Ontario Building Code Updates to 2015

PROPOSED CHANGE TO THE 2015 ONTARIO FIRE CODE (O. Reg. 213/07, as amended current to January 1, 2015)

British Columbia Building Code 2006 Division B Part 3 Fire Protection, Occupant Safety and Accessibility Section 3.2 Building Fire Safety

2012 OBC Changes. Summary of key changes to Life Safety and Fire Protection Systems for CFAA January 22, 2014

BY-LAW AMENDING THE BY-LAW CONCERNING THE SERVICE DE SÉCURITÉ INCENDIE DE MONTRÉAL (RCG )

Phase Two Change Proposal for the Next Edition of the Building Code: 2-CC-B POTENTIAL CHANGE TO ONTARIO S BUILDING CODE:

2014 Alberta Building Code. Part 9 changes relating to Smoke and CO Alarms

Recent Revisions and Proposed Key Changes to Fire Code

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

Interim Amendments to Ontario s 2012 Building Code Retirement Homes. August 17, 2017

PROPOSED CHANGE TO THE 2007 FIRE CODE (OFC)

MAINTENANCE OF FIRE PROTECTION DEVICES WITHIN RESIDENTIAL SUITES OF MULTI-FAMILY BUILDINGS

11:00 to 12:00 Secrets to achieving code-compliant strobe installations. Ralph Coco, Potter Canada Paul Jewett, Mircom Group of Companies

Building Standards Advisory Promoting construction of safe, healthy, habitable buildings

12/14/2013. Fire alarm and emergency power SPRINKLER HEAD

BUILDING CODE COMMISSION

Clarification. Summary of Changes. Summary of Changes. Alan Cavers Area Manager Fire & Security Systems Group

PROPOSED CHANGE TO THE 2007 FIRE CODE (OFC)

2012 Ontario Building Code Update

Residential Care Facilities Requirements

Canadian Fire Alarm Association (CFAA)

Building and Development

Module 9: Ontario Building Code Fire Fighting Provisions

CAN/ULC-S INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

Short Term Accommodations Fire Code Requirements

CAN/ULC S Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning

Fort Rouge Leisure Centre Section HVAC Upgrades Phase 2 Page 1 of 5 Bid Opportunity No March 2013 FIRE ALARM SYSTEMS

BUILDING CODE COMMISSION

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

BUILDING CODE INTERPRETATION

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

MFES READY Make your home fire safe. Home Smoke Alarms

OAA Conference ,

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

CAN/ULC-S1001, INTEGRATED SYSTEMS TEST OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

OWNERS RESPONSIBILITIES & CASE STUDIES ONTARIO FIRE CODE. John Percy, Public Education Officer Waterloo Fire Rescue

BUILDING CODE COMMISSION

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

FIRE ALARM AUDIBILITY IN EXISTING RESIDENTIAL OCCUPANCIES

ENERGY EFFICIENCY AFTER DECEMBER 31, 2016

Part 3 BUILDING CODE MYTHS & INTERPRETATIONS

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

CSA B Code Installation Code for Oil-Burning Equipment Yukon Housing Contractor s Breakfast March 2014 Presented by Ron Bramadat, Ken Alaric &

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION

EFFECTIVE DECEMBER 28, 2010 SECTION 610 CARBON MONOXIDE ALARMS

DIVISION C ADMINISTRATIVE PROVISIONS

CAN/ULC-S1001, INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION & LIFE SAFETY SYSTEMS Simon Crosby, LEL, CET, CFPS October 21, 2015

CHANGES TO THE TEXT OF THE 2010 CODE BOOKS

SOUTH AFRICAN NATIONAL STANDARD

Photovoltaic (Solar) Array Installation Guide

BCBC 2012 CHANGES TO PART 3

Changes in NFPA

BULLETIN BU/EL Revised August 11, 2015

SECTION 915 CARBON MONOXIDE DETECTION

(House Bill 849) Public Safety Rental Dwelling Units Carbon Monoxide Alarms

A Building Manager s Guide to Maintaining Fire Code Compliance

Smoke Alarms and Carbon Monoxide Alarms

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION GUIDELINE RESIDENTIAL CARE FACILITIES 2007 CBC/CFC (R-3.1)

SECTION 907 FIRE ALARM AND DETECTION SYSTEMS

Major Changes to the 2010 National Construction Codes Contractor s Breakfast January 2014

VERIFICATION OF FIRE ALARM SYSTEMS

Louis-Philippe Gagnon Alarm System Auditor UNDERWRITTERS LABORATORIES OF CANADA May 13 th, 2015

Large Family Daycare Guideline

Bold items are particular to the City of Euless

Fire Alarm Acceptance Testing & On-Going Maintenance with The Joint Comm. Standards / Reporting. Prepared Especially for : OSFM TEC 2016

CAN/ULC-S561. To comply, or not to comply. actually it s not even a question! Underwriters Laboratories of Canada. By Alan Cavers & Brian McBain

Major Changes Nova Scotia Building Code 2011 Construction and Maintenance Regulatory Change Industry Briefing

CERTIFICATION BULLETIN

RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE:

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

97 FCV 006 Page 2 of 16 EXPLANATORY MATERIAL

CARBON MONOXIDE ALARM STANDARDS ACT - ENACTMENT Act of Dec. 18, 2013, P.L. 1229, No. 121 Cl. 35 An Act

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

TrueAlert Notification Appliances

SAFETY CODES COUNCIL ORDER. BEFORE THE FIRE TECHNICAL COUNCIL On June 21, 2012

FIRE ALARM AUDIBILITY IN EXISTING RESIDENTIAL OCCUPANCIES. 1 of 7 11/12/ :26 PM

FEO Initiation Devices Dean McLellan

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

Hinesville First United Methodist Church SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

COURSE SYLLABUS FIRE ALARM AND FIRE SUPPRESSION SYSTEMS CORRESPONDENCE COURSE

For additional information regarding R-3.1 residential care facilities please contact (951)

ADMINISTRATIVE ORDER # CERTIFICATES OF USE AND OCCUPANCY FOR EXISTING BUILDINGS

Residential Based Care Facility Guidelines

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Variance from Chapter 297, Signs, of the Former City of Toronto Municipal Code Bloor Street West (High Park)

SMOKE/CARBON MONOXIDE DETECTOR REQUIREMENTS

2018 NICET Code Transition Changes

Building Name: Our Lady of Sorrows Date: July 10, 2013

Red Deer. AMA Regional Meeting. Electrical, Plumbing, Gas, Private Sewage, Building and Fire

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Florida Building Code 2010

Operation & Maintenance Manual

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

BOMA Calgary Luncheon Thursday, October 11, 2012 Building Owners Responsibilities for Fire Safety Equipment (Fire Alarm) Canadian Fire Alarm

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

2007 CBC & CFC Residential Care Facility Requirements (24 hour care only)

Transcription:

Ministry of Municipal Affairs PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED CHANGE NUMBER: SOURCE: B-03-02-07 Ontario-NBC CODE REFERENCE: Division B / 3.2.4.22. and 3.2.4.23. DESCRIPTION OF THE PROPOSED AMENDMENT This proposed change would permit the use of a residential warning system in lieu of an interconnected smoke alarm system. This new system allows the connection of heat detectors, CO alarms, other life safety devices and remote monitoring capabilities. It is also capable of supervising the interconnected devices. EXISTING 2012 BUILDING CODE PROVISION(S) 3.2.4.22. Smoke Alarms (1) Except as permitted by Sentence (6), smoke alarms conforming to CAN/ULC-S531, Smoke Alarms, shall be installed in each dwelling unit and, except for care, care and treatment or detention occupancies required to have a fire alarm system, in each sleeping room not within a dwelling unit. (2) At least one smoke alarm shall be installed on each storey and mezzanine of a dwelling unit. (3) On any storey of a dwelling unit containing sleeping rooms, a smoke alarm shall be installed in, (a) each sleeping room, and (b) a location between the sleeping rooms and the remainder of the storey, and if the sleeping rooms are served by a hallway, the smoke alarm shall be located in the hallway. (4) A smoke alarm shall be installed on or near the ceiling. (5) Except as permitted by Sentence (6), smoke alarms required by Sentence (1) shall, (a) be installed with permanent connections to an electrical circuit, (b) have no disconnect switch between the overcurrent device and the smoke alarm, and (c) in case the regular power supply to the smoke alarm is interrupted, be provided with a battery as an alternative power source that can continue to provide power to the smoke alarm for a period of not less than seven days in the normal condition, followed by 4 min of alarm. (See Appendix A.) (6) Suites of residential occupancy are permitted to be equipped with smoke detectors in lieu of smoke alarms, provided the smoke detectors, (a) are capable of independently sounding audible signals within the individual suites, (b) except as provided by Sentence (7), are installed in conformance with CAN/ULC-S524, Installation of Fire Alarm Systems, and verified in conformance with CAN/ULC-S537, Verification of Fire Alarm Systems, and (c) form part of the fire alarm system. Building and Development Branch Page 1

(7) Smoke detectors permitted to be installed in lieu of smoke alarms as provided in Sentence (6) are not required under Clause (6)(b) to sound an alarm throughout the rest of the building, provided they sound localized alarms within individual suites and otherwise meet the requirements of Clause (6)(b). (See Appendix A.) (8) If more than one smoke alarm is required in a dwelling unit, the smoke alarms shall be wired so that the actuation of one smoke alarm will cause all smoke alarms within the dwelling unit to sound. (9) A smoke alarm required by Sentence (1) shall be installed in conformance with CAN/ULC-S553, Installation of Smoke Alarms. (10) Except as permitted by Sentence (11), a manually operated silencing device shall be incorporated within the circuitry of a smoke alarm installed in a dwelling unit so that it will silence the signal emitted by the smoke alarm for a period of not more than 10 min, after which the smoke alarm will reset and again sound the alarm if the level of smoke in the vicinity is sufficient to reactuate the smoke alarm. (11) Suites of residential occupancy equipped with smoke detectors installed in conformance with CAN/ULC-S524, Installation of Fire Alarm Systems, as part of the fire alarm system in lieu of smoke alarms as permitted by Sentence (6), need not incorporate the manually operated silencing device required by Sentence (10). (12) The sound patterns of smoke alarms shall, (a) meet the temporal patterns of alarm signals, or (b) be a combination of temporal pattern and voice relay. (13) Smoke alarms required by Sentence (1) shall have a visual signalling component conforming to the requirements in 18.5.3. (Light, Color and Pulse Characteristics) of NFPA 72, National Fire Alarm and Signaling Code. (See Appendix A.) (14) The visual signalling component required by Sentence (13) need not, (a) be integrated with the smoke alarm provided it is interconnected to it, (b) be on battery backup, or (c) have synchronized flash rates, when installed in a dwelling unit. (15) The luminous intensity for visual signalling components required by Sentence (13) that are installed in sleeping rooms shall be a minimum of 175 cd. 3.2.4.23. Voice Communication Systems PROPOSED CODE CHANGE Revise existing Article 3.2.4.22. and add new Article 3.2.4.23. as follows: 3.2.4.22. Smoke Alarms (1) Except as provided in Article 3.2.4.23. smoke alarms shall be installed in accordance with this Article. (12) Except as permitted by Sentence (7), smoke alarms conforming to CAN/ULC-S531, Smoke Alarms, shall be installed in each dwelling unit and, except for care, care and treatment or detention occupancies required to have a fire alarm system, in each sleeping room not within a dwelling unit. (23) At least one smoke alarm shall be installed on each storey and mezzanine of a dwelling unit. (34) On any storey of a dwelling unit containing sleeping rooms, a smoke alarm shall be installed in, (a) each sleeping room, and (b) a location between the sleeping rooms and the remainder of the storey, and if the sleeping rooms are served by a hallway, the smoke alarm shall be located in the hallway. Building and Development Branch Page 2

(45) A smoke alarm shall be installed on or near the ceiling. (56) Except as permitted by Sentence (7), smoke alarms required by Sentence (2) shall, (a) be installed with permanent connections to an electrical circuit, (b) have no disconnect switch between the overcurrent device and the smoke alarm, and (c) in case the regular power supply to the smoke alarm is interrupted, be provided with a battery as an alternative power source that can continue to provide power to the smoke alarm for a period of not less than seven days in the normal condition, followed by 4 min of alarm. (See Appendix A.) (67) Suites of residential occupancy are permitted to be equipped with smoke detectors in lieu of smoke alarms, provided the smoke detectors, (a) are capable of independently sounding audible signals within the individual suites, (b) except as provided by Sentence (8), are installed in conformance with CAN/ULC-S524, Installation of Fire Alarm Systems, and verified in conformance with CAN/ULC-S537, Verification of Fire Alarm Systems, and (c) form part of the fire alarm system. (78) Smoke detectors permitted to be installed in lieu of smoke alarms as provided in Sentence (7) are not required under Clause (7)(b) to sound an alarm throughout the rest of the building, provided they sound localized alarms within individual suites and otherwise meet the requirements of Clause (7)(b). (See Appendix A.) (89) If more than one smoke alarm is required in a dwelling unit, the smoke alarms shall be wired so that the actuation of one smoke alarm will cause all smoke alarms within the dwelling unit to sound. (910) A smoke alarm required by Sentence (2) shall be installed in conformance with CAN/ULC-S553, Installation of Smoke Alarms. (1011) Except as permitted by Sentence (12), a manually operated silencing device shall be incorporated within the circuitry of a smoke alarm installed in a dwelling unit so that it will silence the signal emitted by the smoke alarm for a period of not more than 10 min, after which the smoke alarm will reset and again sound the alarm if the level of smoke in the vicinity is sufficient to reactuate the smoke alarm. (1112) Suites of residential occupancy equipped with smoke detectors installed in conformance with CAN/ULC- S524, Installation of Fire Alarm Systems, as part of the fire alarm system in lieu of smoke alarms as permitted by Sentence (7), need not incorporate the manually operated silencing device required by Sentence (10). (1213) The sound patterns of smoke alarms shall, (a) meet the temporal patterns of alarm signals, or (b) be a combination of temporal pattern and voice relay. (1314) Smoke alarms required by Sentence (2) shall have a visual signalling component conforming to the requirements in 18.5.3. (Light, Color and Pulse Characteristics) of NFPA 72, National Fire Alarm and Signaling Code. (See Appendix A.) (1415) The visual signalling component required by Sentence (14) need not, (a) be integrated with the smoke alarm provided it is interconnected to it, (b) be on battery backup, or (c) have synchronized flash rates, when installed in a dwelling unit. (1516) The luminous intensity for visual signalling components required by Sentence (14) that are installed in sleeping rooms shall be a minimum of 175 cd. Building and Development Branch Page 3

3.2.4.23. Residential Fire Warning Systems (1) Except where a fire alarm system is installed or required in a building, smoke detectors forming part of a residential fire warning system installed in conformance with CAN/ULC-S540 Residential Fire Warning Systems: Installation, Inspection, Testing and Maintenance, are permitted to be installed in lieu of all smoke alarms required by Article 3.2.4.22, provided that the system (a) is capable of sounding audible signals in accordance with Articles 9.10.19.2. and 9.10.19.5., (b) is provided with a visual signalling component in accordance with Article 9.10.19.3., (c) is powered in accordance with Article 9.10.19.4., and (d) is provided with a silencing device in accordance with Article 9.10.19.6. 3.2.4.2324. Voice Communication Systems RATIONALE FOR CHANGE Problem/General Background The building official community has requested the use of residential fire warning systems in lieu of the currently required interconnected smoke alarms. The ULC Committee on Fire Alarm and Life Safety Equipment and Systems updated CAN/ULC-S540, Residential Fire Warning Systems: Installation, Inspection, Testing and Maintenance in fall of 2012. This standard provides the minimum requirements for the design, installation, inspection, testing and maintenance of residential fire warning systems for use in suites of residential occupancy, dwelling units and care occupancy. Justification/Explanation This proposed change would harmonize requirements with the model National Building Code of Canada. Interconnected smoke alarms and residential fire warning systems will provide detection and audible signals to alert the occupants of an emergency situation. Allowing the option of a residential fire warning system, will enhance the level of life safety provided to the occupants. Additionally, this allows for the interconnection of heat detectors, CO alarms, other life safety devices and remote monitoring capabilities. This will also allow for the supervision of the interconnected devices. Cost/Benefit Implications Since this requirement will be optional, the costs will be minimal and will vary depending on the option chosen. Enforcement Implications This requirement will facilitate enforcement actions by having the reference to a National Standard. Who is Affected Designers, building officials. Building and Development Branch Page 4

Objective Based Analysis Provision Objective/Functional Statement Division B 3.2.4.22. (1) [F81,F11-OS1.5] (2) 1 [F11, F81-OS1.5] (3) 2 [F11-OS1.5] (4) 3 [F11-OS1.5] (5) 4 [F11-OS1.5] (6) 5 [F11,F81-OS1.5] (7) 6 [F11,F81-OS1.5] (8) 7 (9) 8 [F11-OS1.5] (10) 9 [F81,F11-OS1.5] (11) 10 [F81,F11-OS1.5] (12) 11 (13) 12 [F11-OS1.5] (14) 13 [F74-OA-2] [F11-OS1.5] (15) 14 (16) 15 [F74-OA-2] [F11-OS1.5] Division B 3.2.4.23. Division B 3.2.4.2324. (1) [F11, F12-OS3.7] Building and Development Branch Page 5

Provision Objective/Functional Statement (2) [F11-OS1.5] (3) [F11-OS1.5] (4) F11-OS1.5] [F13-OS1.4,OS1.5] (5) [F11-OS1.5] (6) [F12-OS3.7] (7) [F11-OS1.5] (8) [F11-OS1.5] (9) [F11-OS1.5] (10) OTHER SUPPORTING MATERIALS Building and Development Branch Page 6