Light oil - kerosene burner

Similar documents
Light oil / kerosene burner

Light oil burners. One stage operation

Oil burners Brûleurs fioul Stookoliebranders

Parts Available from

CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80

Single stage operation oil burner

Forced draught gas burner

Single stage operation oil burner

RETROFIT APPLICATIONS ONLY

Forced draught gas burner

INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual )

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

Single stage operation oil burners

INSTRUCTION MANUAL FOR OIL BURNER MODELS

INSTRUCTION MANUAL FOR OIL BURNER MODELS

TWO STAGE HEAVY OIL BURNERS

15 20 kw kw kw

Gas-Gebläsebrenner Brûleur gaz à air soufflé Forced draught gas burner Gasventilatorbrander Quemador de gas de aire soplado

Installation, use and maintenance instructions. Kerosene burner. One stage operation CODE MODEL TYPE RDB2.2 FIREBIRD C20 70K DGT 744LD2X

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Forced draught natural gas/propane burner

Oil TRIANCO. EuroStar Range BURNER DETAILS TRIANCO - OIL BURNER. To be retained by householder

C Elba Dual. Cast-iron, floor-standing boiler. High quality Italian product. Life-enhancing heat

Capri B Cast iron combination oil-fired boiler with water tank

Installation & Maintenance Manual

Capri R CH only, oil-fired, cast iron boiler

Installation and operating instructions B1FUV Classic

RETROFIT APPLICATIONS ONLY

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

RIELLO 40 GS/M SERIES

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction MOL1650 T3N 323 2FH.

Installation & Maintenance Manual

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

Single stage operation forced draught natural gas/propane burner

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 10 E R

Installation and operating instructions B2KSV Classic

Technical information. Remeha P200. Pressurized boiler. Heat output: kw

INSTALLATION AND OPERATION MANUAL

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

Installation, use and maintenance instructions. Light oil burner. Two stage operation CODE MODEL TYPE RL X (1) - 08/2012

DH-Direct Fired Poultry Farm Diesel Heater

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS

ST 40 Oil Burner. Installation & Maintenance Manual

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 30 A

10.1 Troubleshooting Condition Table

Infrared Diesel Heater

BIX B-One 100 kw INSTALLATION GUIDE

RL 28/2-38/2-50/2 Low - High Operation

40 SERIES GAS BURNER MODEL 400 NATURAL GAS/PROPANE INSTALLATION INSTRUCTIONS AND OWNER S HANDBOOK

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 45A

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

DOMESTIC WATER HEATER OIL FIRED

Oil burners fuel unit with solenoid valve

INSTALLATION AND MANINTENANCE INSTRUCTIONS

Oil burners fuel unit with solenoid valve

WARNING. Keep area around vent terminal free of snow, ice, and debris.

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

EURO-OIL SERIES TYPES G.. G../. OR.. OR../. F.. FR..

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

CMO32 CMO50 DOMESTIC WATER HEATER OIL-FIRED. Models: CMO32 CMO50

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

PARAFFIN/DIESEL HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-400TRLT INDIRECT FIRED HEATER TRAILER

RL 70/2-100/2-130/2 Low - High Operation

1. GENERAL SAFETY RULES

Heating Equipment. gas boilers RX GB. installation and servicing instructions

EUROFLAT SERIES TYPES C... S... M...

LOW NOx MODULATING GAS BURNERS

Dual fuel gas oil/ gas burners

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Model 601CRD Oil Burner

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

Propane Heater REMKO PGM 30 REMKO PGM 60

Vortex 15/21 Utility and Outdoor Module Vortex Combi 21 and Outdoor Vortex Combi 21

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

IST 03 C ELBA DUAL INSTALLATION, USE AND MAINTENANCE

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

RS /E-EV C01 SERIES

RS /E-EV C01 SERIES

PEGASUS F2 N 2S. CAST IRON GAS BOILER for heating with electronic ignition and flame control INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE

INSTALLATION & SERVICING MANUAL FOR WARMFLOW OIL FIRED WARM AIR HEATERS MODELS WAH 100/150 WAH 200/300 WAH 500/600

Utility and Utility System Floor Standing Condensing Oil Boiler Range ADDENDUM ATTENTION INSTALLERS - UPDATED INFORMATION!

en Direct oil-fired space heaters HD... Operator's manual

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

EUROBOX SERIES TYPES CM...N SM...N MM...N

MICROFLAT SERIES TYPES C.../U T X

EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION

SECTION AUXILIARY HEATER

Weishaupt dual fuel burners Sizes 30 to 70 Version 1LN (NO X -reduction on gas operation) 1/2003 CA

SUPPLEMENTAL INSTRUCTIONS: DIRECT VENT INSTRUCTIONS FOR HIGH EFFICIENCY OIL-FIRED HOT WATER BOILER

Light oil burner. Progressive two-stage or modulating operation. Installation, use and maintenance instructions RL 1000/M C10 TC FS X

External Module Floor Standing Condensing Oil Boiler Range ADDENDUM ATTENTION INSTALLERS - UPDATED INFORMATION!

BENSON LINEAR RADIANT TUBE

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing

INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS

MAINTENANCE AND SERVICE GUIDE

Forced draught gas burners

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

Transcription:

Installation, use and maintenance instructions Light oil - kerosene burner One stage operation CODE MODEL TYPE 374374 G3B 437T 90 (4) - 05/0

TECHNICAL FEATURES TYPE 437T Thermal power output 9 35 kw.6 3 kg/h Fuel Gas oil 35 sec max. viscosity 6 mm/s at 0 C Kerosene 8 sec Electrical supply Single phase, 30V ± 0% ~ 50Hz Motor Capacitor Ignition transformer Pump Absorbed electrical power Run current 0.7A 850 rpm 98 rad/s 4 F Secondary 8 kv 6 ma Maximum pressure 4 bar (03 psi) 0.5 kw Burner with CE marking in conformity with EEC Directives: Electromagnetic Compatibility 004/08/ EC, Low Voltage 006/95/EC and Machines 006/4/EC. The burner meets protection level of IP 40, EN 6059. Fig. 7 8 6 4 6 9 3 D5506 5 Return line Suction line 3 Gauge connection 4 Pump pressure regulator 5 Vacuum gauge connection 6 Screws fixing air damper 7 Hydraulic jack with air damper 8 Lock-out lamp and reset button 9 Flange with insulating gasket HYDRAULIC JACK OPERATION 7)(Fig. ) DANGER It is strongly recommended a periodic check of the pump pressure operation (annually or better every six months, if the burner operation is continuous). If the value is lower than bar, compared to that one of the initial setting, please check the cleaning of the pump and line filters. In case the pressure setting was not restorable, please replace the pump, in order to guarantee that the pump pressure during the prepurge time is at least 3.7 bar.

EQUIPMENT Quantity 4 Description Flexible pipe with nipple Flange with insulating gasket Screws and nuts for flange Screw of pump by-pass Grommet Screw with two nuts for flange WORKING RANGE (as EN 67) Pressure in the combustion chamber mbar 0.8 0.6 0.4 0. 0.5.5 3 Fuel output - kg/h D53 0 5 30 35 Thermal power - kw DIMENSIONS Flange 80 = Burner 5 93 03 = 45 45 75 7 5 64 ø 90 30 50 9 D5509

MOUNTING THE BURNER It is necessary that the insulating gasket (9, fig. ) is placed between the boiler door and the burner flange. This insulating gasket has six holes, which, if necessary, can be modified as shown on the drawing on the right. Verify that the installed burner is lightly leaned towards the button. (See figure ). D54 Fig. BURNER FIXING The burner is designed to allow entry of the flexible oil-lines on either side of the burner. S7386 D58 S7383 3

OIL LINES D59 min. 0. m H max. 4 m PRIMING THE PUMP Loosen the plug of the vacuum gauge (5, fig. ) and wait until the fuel flows out. H meters 0.5.5 L meters I. D. 8 mm 0 0 40 60 I.D. 0 mm 0 40 80 00 H = Difference of level. L =Max. length of the suction line. I.D.= Internal diameter of the oil pipes. H D50 H max. 4 m H meters 0 0.5.5 3 3.5 L meters I. D. 8 mm 35 30 5 0 5 8 6 I.D. 0 mm 00 00 00 90 70 30 0 WARNING The pump is supplied for use with a one pipe system. For use on a two pipe system, it is necessary to screw the by-pass screw (A) supplied as burner s accessory. (See figure). The pump vacuum should not exceed a maximum of 0.4 bar (30 cm Hg). Beyond this limit gas is released from the oil. Oil lines must be completely airtight. The return line should terminate in the oil tank at the same level as the suction line; in this case a non-return valve is not required. Should however the return line arrives over the fuel level, the nonreturn valve is indispensable. This solution however is less safe than previous one, due to the possibility of leakage of the valve. A D599 PRIMING THE PUMP: Start the burner and wait for the priming. Should lock-out occur prior to the arrival of the fuel, await at least 0 seconds before repeating the operation. Warning: before starting the burner make sure that the return pipe-line is not clogged: any obstruction would cause the pump seals to break. WARNING: Check periodically the flexible pipes conditions. Using kerosene, they have to be replaced at least every years. A metal bowl filter with replaceable micronic filter must be fitted in the oil supply pipe. 4

ELECTRICAL WIRING 30V ~ 50Hz N L WARNING Do not exchange the neutral with the phase. Switch with fuse 6A max. Neutral T Regulating thermostat T Limit thermostat with manual resetting N L Remote lock-out lamp (30V - 0.5A max.), if required CARRIED-OUT IN THE FACTORY Valve 3 4 5 6 7 8 9 Blue Blue White (50V) Brown Brown Black Black Capacitor M ~ Motor Terminal block of control-box 530SE * D58 NOTES Wires of mm section. The electrical wiring carried out by the installer must be in compliance with the rules in force in the Country. To remove the control-box from the burner, loosen screw (A) (see figure) and pull towards the arrow. The photoresistance is fitted directly into the control-box (underneath the ignition-transformer) on a plug-in support. A 3 S706 TESTING Check the shut-down of the burner by opening the thermostats. RUN OF THE ELECTRICAL CABLE - Grommet N - Neutral - Cable-clamp L - Phase 3 - Terminal block - Burner-earth 5

COMBUSTION ADJUSTMENT In conformity with Efficiency Directive 9/4/EEC the application of the burner on the boiler, adjustment and testing must be carried out observing the instruction manual of the boiler, including verification of the CO and CO concentration in the flue gases, their temperatures and the average temperature of the water in the boiler. To suit the required appliance output, fit the nozzle then adjust the pump pressure and the air damper opening in accordance with the following schedule. The values shown in the table are measured on a CEN boiler (as per EN 67). They refer to.5% CO at sea level and with light oil and room temperature of 0 C. Nozzle FUEL GAS OIL Pump pressure Burner output Air damper adjustment 3 GPH Angle bar kg/h ± 4% Set-point 0.40 80 /60.6.95 0.50 60.0. 0.60 60.4.8 0.65 60.6 3. 0.75 60 3.0 3.7 Nozzle FUEL KEROSENE Pump pressure Burner output Air damper adjustment 3 GPH Angle bar kg/h ± 4% Set-point 0.50 60 /80 8.5.5 0.60 60 /80 8.8.75 0.65 60 8.9. 0.75 60 8..5 0.85 60 8.5 3.0.00 60 8 3.0 4.0 NOZZLES RECOMMENDED: Monarch type R - NS Delavan type W - A - E Steinen type H - Q Danfoss type H - S NOZZLES RECOMMENDED: Monarch type R - NS Delavan type W - A - E Steinen type H - Q Danfoss type H - S Angle: 60 - in most cases. 80 - in cases of flame detachment, during ignitions at low temperatures. Angle: 60 - in most cases. 80 - in cases of flame detachment, during ignitions at low temperatures. PRESSURE: 8 bar: the pump leaves the factory set at this value, which is suitable only for kerosene. FOR GAS OIL INCREASE PRESSURE bar: pressure suitable for gas oil in most cases. 4 bar: improves flame retention; it is therefore suitable for ignitions at low temperatures. PRESSURE: 8 bar: the pump leaves the factory set at this value. 0 bar: maximum pressure for kerosene. 6

3 AIR DAMPER ADJUSTMENT: The mobile air damper () operated by the jack () assures the complete opening of the air intake. The regulation of the air-rate is made by adjusting the fixed air damper (3), after loosing the screws (4). When the optimal regulation is reached, screw tight the screws (4) to assure a free movement of the mobile air damper (). 3 4 D5550 4 The settings indicated in the schedule refer to the burner with its metal cover fitted and the combustion chamber with zero depression. These regulations are purely indicative. Each installation however, has its own unpredictable working conditions: actual nozzle output; positive or negative pressure in the combustion-chamber, the need of excess air, etc. All these conditions may require a different air damper setting. It is important to take account of the fact that the air output of the fan differs according to whether the burner has its metal cover fitted or not. Therefore we recommended to proceed as follows: adjust the air damper as indicated in the schedule (3); mount the cover, simply by means of the upper screw; check smoke number; should it become necessary to modify the air output, remove the cover by loosening the screw, adjust the air damper, remount the cover and finally recheck the smoke number. ELECTRODE SETTING Attention: Before assembling or removing the nozzle, loosen the screw (A) and move the electrodes ahead 4 ± 0.3 mm IMPORTANT: THESE DIMENSIONS MUST BE OBSERVED D530 A.5 mm 7

BURNER START-UP CYCLE Thermostat Motor Ignition transformer Valve Flame Lock-out lamp Normal ~ s Lock-out, due to light-failure ~ s ~ 5s D59 POSITION D ENTRETIEN Insert in the hole () (left side) the pin () and fix the burner with the nut (3) fitted wrong-side up. FLANGE 3 D535 8

RIELLO S.p.A. I-37045 Legnago (VR) Tel.: +39.044.630 http:// www.riello.it http:// www.rielloburners.com Subject to modifications