SPRINKLER ALARM TECHNICAL DATA SPRINKLER ALARM MODEL - GA

Similar documents
FOAM MAKER MODEL - FMA & FMA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA INSTALLATION, TESTING AND MAINTENANCE APPLICATION SPECIFICATION

FOAM CHAMBER MODEL - FCA & FCA-S TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100. Stainless Steel Construction

WATER POWERED OSCILLATING MONITOR

Pre-Pack INTEGRATED PRE-ACTION SYSTEM

DOUBLE INTERLOCK, PREACTION SYSTEM WITH ELECTRIC/PNEUMATIC RELEASE

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH WET PILOT ACTUATION

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH ELECTRIC RELEASE

FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION

FOAM CHAMBER MODEL - FCA & FCA-S TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100. Stainless Steel Construction

Nitin Ventures FZE. (A Division of Nitin Fire Protection Industries Ltd.)

mechanical. OPERATION Rapidrop Global

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS. Product Submittal A PART OF

Design Criteria. Installation

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

Model/Sprinkler Identification Numbers

Owner s Manual. Pelican Custom Premium WHWF 1354/1665

The Series LFII (TY3596) Residential

GA3650TB Blower Accessory

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

Series ELO-231 Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

AeroVent 3X Product Manual

INSTALLATION, OPERATION AND MAINTENANCE

XT Series Thermostats

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Drain Tempering Reservoir READ & SAVE THESE INSTRUCTIONS. Installation, Operation, & Maintenance. TRION

Technical Data. Installation

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description

Models: FM FM WARNING

Series RFII 5.6 K-factor. Flush II Concealed Pendent Sprinklers

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Series LFII Residential Sprinklers Flat-Plate Concealed Pendent 4.9 K-Factor General Description

Sprinkler Identification Numbers

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138


Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Model 8300FP Freeze Resistant Combination Shower Eye/Face Wash

Model Combination Shower Eye/Face Wash

Model ELOC 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

CL & CLG Clamp Mount Mixers

AeroVent 1 Product Manual

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-Factor General Description

55-Gallon Dispenser Package

Flat Line Spray Systems Kits

Model /8300CRP-8309CRP Shower & Eye/Face Wash

SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual

User s Manual and Operating Instructions

INSTRUCTION MANUAL HS-229G

20 High velocity Air

AeroVent Standard Product Manual

Operation, Maintenance and Installation Manual

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

Comfort Series Instant Hot Water System

Parts Manual Vermeer/McLaughlin V500LTHD Vacuum Machine Part #E (SERIAL # 5DHDLT _5DHDLT )

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

Technical Data Approvals UL Listed and FM Approved. Refer to Tables 1, 2, and 3, as applicable.

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50

TrueClean ToteCleaner

Installation and Maintenance "L" and "LS" Series

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

User s Manual and Operating Instructions

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard)

Model CHEC 8.0 K-factor Concealed Horizontal Extended Coverage Quick Response Light Hazard, Sidewall Sprinklers General Description

Troubleshooting the MPH 24FP Series Pedestal Hydrant

Model /8320CRP Shower and Eye/Face Wash

DELUGE VALVE MODEL: SD-DVH2 TECHNICAL DATA TRIM DESCRIPTION DESCRIPTION VALVE OPERATION. 82 ASTM A 216 WBC.

5-Gallon Pail Mixer OWNERS MANUAL M-2000 SERIES MIXERS. Contents: Page: Safety, General & Receiving... 2 Operation... 3 Parts List...

Sprinkler Identification Number (SIN) TY4234. Page 1 of 8 APRIL 2012 TFP Technical Services

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

SFD. Suburban Filter Dryer. User Manual Installation Instructions

Model 8330 Stainless Steel Combination Shower Eye/Face Wash

Please Read and Save These Instructions.

Model 9001, Alarm

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

INSTALLATION ADJUSTMENT SERVICE

Installation Manual Universal Single-Arm Side-of-Pole Mount UNI-SA/21.5

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

QUICK PRIME INSTALLATION AND SERVICE MANUAL

Model WS TM 5.6 K-factor Specific Application Window Sprinklers, Horizontal and Pendent Vertical Sidewall General Description

DECORATIVE GAS LOG PLACEMENT INSTRUCTIONS

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

INSTALLATION AND OPERATION INSTRUCTIONS

MODEL NO CRIMPING AND BEADING MACHINE OPERATION, PARTS & MAINTENANCE MANUAL

Karbon Kitchen Sink Tap

SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3

MOJAVE. Mojave ShowerSpa Model #1016 Owner's Manual

NOTICE TO INSTALLER: Instructions must remain with installation. FW Supersedes HomeGuard OPTIMA

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Transcription:

SPRINKLER ALARM TECHNICAL DATA MODEL MOUNTING TYPE WATER WORKING PRESSURE CONNECTION GA Type-A & Type-B 17.5 Bar (250 PSI) Inlet : 3/4 BSPT (3/4 NPT) Drain : 1 BSPT (1 NPT) GONG DIAMETER 205mm (8 ) GONG DEPTH 50mm (2 ) FINISH Red RAL 3000 WEIGHT (Approx) 3.0 Kg ORDERING Mounting Type INFORMATION SPRINKLER ALARM MODEL - GA HD Sprinkler Alarm is a hydraulically driven mechanical bell. It does sound a continuous alarm when the sprinkler system operates. The impeller and drive shaft are energy efficient, made from light weight nonmetallic material and do not require any external lubrication. The gong, protection cover and motor housing are made of corrosion resistant aluminium alloy. Sprinkler Alarm with mounting Type-B is wall mounting type. Type-B is suitable for 50 to 250 mm thick wall and curves with 325 mm long drive shaft as standard supply. For wall thickness 250 to 450 mm or longer a special extension drive shaft can be supplied on request. OPERATION When the sprinkler system is activated by the fusing of one or more automatic sprinklers at fire condition, the water flows through the Alarm / Deluge Valve and enters the sprinkler alarm through the nozzle, creating a high velocity jet which strikes the impeller causing the drive shaft and the striker arm assembly to rotates. The alarm arm assembly rotates and strikes to impact against the aluminium gong, producing a continuous alarm. The waste water then drains out through a 25NB drain outlet. DESIGN REQUIREMENT Strainer is required in the Sprinkler Alarm line to protect the 3.2 mm nozzle in the water motor housing from clogging. The alarm line pipe must be 20NB (3/4 ) size with 22.8 mtrs. (75 feet) maximum total length of pipe with minimum number of fittings. If the length of the pipe exceeds 22.8 mtrs. (75 feet), then higher size pipe must be used to reduce hydraulic friction loss. The Sprinkler Alarm should not be located more than 1.8 mtrs. (Six feet) above Alarm Valve / Deluge Valve. One Sprinkler Alarm may be connected to one or maximum of three alarm lines of seperate fire systems. For interconnecting more than one Sprinkler Alarm, a swing check valve in each line need to be provided. MAINTENANCE Qualified and trained person must commission the system. After few initial successful tests an authorised person must be trained to perform inspection and testing of the system. Even though corrosion resistant material is used in the construction of the Sprinkler Alarm, it is suggested that the Sprinkler Alarm be examined and tested at regular intervals to ensure that the nozzle is free from obstruction and the impeller is free to rotate. The inspection should include the following in addition to any specific requirement of NFPA, or as required by authority having jurisdiction. 1. Clean 20 NB (3/4 ) Strainer provided in the alarm line. 2. Open the 3/8 plug provided on the inlet of the Sprinkler Alarm and clean out any accumulated particles. 3. Detach the Gong, clean the internal surface and refit in proper sequence. 4. Activate the Sprinkler Alarm to verify clear and steady sound. JANUARY, 2013 PAGE 1 OF 5

R SPRINKLER ALARM - GA MOUNTING TYPE - A 17 2 1 3 4 5 11 SPRINKLER ALARM MODEL - GA 3/4" BSP INLET FM APPROVED LISTED 3S38 HD FIRE PROTECT PVT. LTD. A Ø122 16 15 12 13 19 9 20 CLEAN OUT PLUG VIEW 'A' OUTLET TO OPEN DRAIN 1" BSP 10 8 Ø233 18 7 6 158 ITEM NO. CODE DESCRIPTIOIN QTY. MATERIAL 1 5001 HOUSING 1 ALUMINIUM ALLOY 2 5002 GONG IMPELLER 1 DELRIN 3 5003 RETAINING RING 1 SS 316 4 5004 DRIVE SHAFT ADAPTOR 1 DELRIN 5 5005 BUSH 1 ALUMINIUM ALLOY 6 5006 PROTECTION COVER 1 ALUMINIUM ALLOY 7 5007 GONG 1 ALUMINIUM ALLOY 8 5008 GONG POST 1 ALUMINIUM ALLOY 9 5018 NYLON WASHER 2 NYLON 10 5009 DOME NUT 1 ALUMINIUM ALLOY 11 18 STRIKER ASSEMBLY 1 ALUMINIUM ALLOY 12 50 STRIKER ARM BOLT 1 ALUMINIUM ALLOY 13 5015 STRIKER ARM WASHER 1 ALUMINIUM ALLOY 5024 DRIVE SHAFT 1 ALUMINIUM ALLOY 15 5016 HOUSING COVER 1 ALUMINIUM ALLOY 16 5017 GASKET 1 NEOPRENE 17 9029 CH. HEAD BOLT 6 PLATED STEEL 18 5020 GONG STICKER 1 PVC 19 9025 SCREW 1 PLATED STEEL 20 5022 PLUG 1 ALUMINIUM ALLOY ALL DIMENSIONS ARE IN MM JANUARY, 2013 PAGE 2 OF 5

R SPRINKLER ALARM - GA MOUNTING TYPE - B 17 2 1 19 22 21 3 4 5 11 SPRINKLER ALARM MODEL - GA 3/4" BSP INLET FM APPROVED LISTED 3S38 HD FIRE PROTECT PVT. LTD. A Ø122 16 15 12 13 9 20 CLEAN OUT PLUG VIEW 'A' OUTLET TO OPEN DRAIN 1" BSP 40 10 8 Ø233 18 7 6 71 WALL THICKNESS 88 ITEM NO. CODE DESCRIPTIOIN QTY. MATERIAL 1 5001 HOUSING 1 ALUMINIUM ALLOY 2 5002 GONG IMPELLER 1 DELRIN 3 5003 RETAINING RING 1 SS 316 4 5004 DRIVE SHAFT ADAPTOR 1 DELRIN 5 5005 BUSH 1 ALUMINIUM ALLOY 6 5006 PROTECTION COVER 1 ALUMINIUM ALLOY 7 5007 GONG 1 ALUMINIUM ALLOY 8 5008 GONG POST 1 ALUMINIUM ALLOY 9 5018 NYLON WASHER 2 NYLON 10 5009 DOME NUT 1 ALUMINIUM ALLOY 11 18 STRIKER ASSEMBLY 1 ALUMINIUM ALLOY 12 50 STRIKER ARM BOLT 1 ALUMINIUM ALLOY 13 5015 STRIKER ARM WASHER 1 ALUMINIUM ALLOY 5024 DRIVE SHAFT 1 ALUMINIUM ALLOY 15 5016 HOUSING COVER 1 ALUMINIUM ALLOY 16 5017 GASKET 1 NEOPRENE 17 9029 CH. HEAD BOLT 6 PLATED STEEL 18 5020 GONG STICKER 1 PVC 19 9025 SCREW 1 PLATED STEEL 20 5022 PLUG 1 ALUMINIUM ALLOY 21 5023 COUPLING 1 STEEL 22 5025 SUPPORT PIPE 1 GI PIPE (BY INSTALLER) ALL DIMENSIONS ARE IN MM JANUARY, 2013 PAGE 3 OF 5

INSTALLATION OF SPRINKLER ALARM MODEL GA MOUNTING TYPE - A The Sprinkler Alarm with mounting Type-A is supplied pre-assembled. Connect the Alarm port of the Alarm valve or Deluge valve to the inlet of the sprinkler alarm assembly with 20NB (3/4 ) pipe with proper support. A 20NB (3/4 ) strainer is to be provided as close as possible to the Sprinkler Alarm assembly. Connect the 25NB (1 ) drain pipe to the housing, taking due care that the drain discharge is running to a safe location and keep the drain free from obstruction. A blocked drain discharge may create back pressure and prevent the Sprinkler Alarm from operating properly. The 20NB (3/4 ) inlet and 25NB (1 ) drain pipe should be properly supported with the help of the bracket so that in turn proper support is available for the Sprinkler Alarm. The inlet and the drain pipe is to be preferably connected with an union for easy removal and re-fixing of the Sprinkler Alarm during maintenance. The Sprinkler Alarm must be installed in accordance with the requirement of NFPA, TAC or to the requirement of the local authority having jurisdiction. INSTALLATION OF SPRINKLER ALARM MODEL GA MOUNTING TYPE - B 1. Locate and cut a hole through the building wall to accommodate a 20NB (3/4 ) pipe with coupling (galvanised pipe to be supplied by the installer). The required length of support pipe is equal to the thickness of the wall minus 30 millimetres. The pipe is to be threaded with the standard 20NB (3/4 ) pipe threading on the both ends to a length of 20 millimetres. Cut the drive shaft length, equal to the wall thickness plus 43 millimeters. 4. Move to the other side of the wall, place protection cover (6) on to the pipe coupling (screwed to the pipe) and hold against the wall. Insert the bush (5, assembly with drive shaft adaptor) into the hole provided in the protection cover and thereby hand tighten the coupling extending through the wall. Make sure that the drive shaft is properly fitted in the square hole of impeller and drive shaft adaptor. This can be ensured by rotating the drive shaft adaptor. The drive shaft adaptor should rotate without any binding while tightening the bush. If any binding is noticed then unscrew the bush and refit. After ensuring that the drive shaft is properly placed in the square holes at both ends, wrench tight the bush. 5. Place the gong over the gong post with washers as shown in the cross-sectional drawing and hand tighten the dome nut, rotate the gong until the lettering is properly originated. Wrench tighten the dome nut. 6. Connect the 25NB (1 ) open drain pipe to the motor housing, taking due care that the drain discharge is running to a safe location and keep it free from obstruction. 2. Insert one end of the drive shaft (19) into the square hole provided in the impeller (2) of the Sprinkler Alarm gong assembly. One end of 20NB (3/4 ) support pipe is to be screwed to the coupling (26) provided with the assembly and the other end of the pipe is to be screwed to the housing (1) of the Sprinkler Alarm motor assembly as shown in the figure. Position this assembly against the building wall through a washer (24) with the support pipe extending through the wall. 3. Connect the alarm port of the Alarm Valve or Deluge Valve to the inlet of the Sprinkler Alarm assembly with 20NB (3/4 ) pipe, with proper support. A 20NB (3/4 ) strainer is to be provided as close as possible to the Sprinkler Alarm assembly. JANUARY, 2013 PAGE 4 OF 5

LIMITED WARRANTY HD FIRE PROTECT PVT. LTD. hereby referred to as HD FIRE warrants to the original purchaser of the fire protection products manufactured by HD FIRE and to any other person to whom such equipment is transferred, that such products will be free from defect in material and workmanship under normal use and care, for two (2) years from the date of shipment by HD FIRE. Products or Components supplied or used by HD FIRE, but manufactured by others, are warranted only to the extent of the manufacturer s warranty. No warranty is given for product or components which have been subject to misuse, improper installation, corrosion, unauthorized repair, alteration or un-maintained. HD FIRE shall not be responsible for system design errors or improper installation or inaccurate or incomplete information supplied by buyer or buyer s representatives. HD FIRE will repair or replace defective material free of charge, which is returned to our factory, transportation charge prepaid, provided after our inspection the material is found to have been defective at the time of initial shipment from our works. HD FIRE shall not be liable for any incidental or consequential loss, damage or expense arising directly or indirectly from the use of the product including damages for injury to person, damages to property and penalties resulting from any products and components manufac tured by HD FIRE. HD FIRE shall not be liable for any damages or labour charges or expense in making repair or adjustment to the product. HD FIRE shall not be liable for any damages or charges sustained in the adaptation or use of its engineering data & services. In no event shall HD Fire s product liability exceed an amount equal to the sale price. The foregoing warranty is exclusive and in lieu of all other warranties and representation whether expressed, implied, oral or written, including but not limited to, any implied warranties or merchantability or fitness for a particular purpose. All such other warranties and representations are hereby cancelled. NOTICE : The equipment presented in this bulletin is to be installed in accordance with the latest publication standards of NFPA or other similar organisations and also with the provision of government codes or ordinances wherever applicable. The information provided by us are to the best of our knowledge and belief, and are general guidelines only. Site handling and installation control is beyond our reach. Hence we give no guarantee for result and take no liability for damages, loss or penalties whatsoever, resulting from our suggestion, information, recommendation or damages due to our product. Product development is a continuous programme of HD FIRE PROTECT PVT. LTD. and hence the right to modify any specification without prior notice is reserved with the company. C-3/6, THE NANDANVAN IND. ESTATE, L.B.S. MARG, THANE 400 604., INDIA. PHONES : + (91) 22 2583 5434 2582 6958 2582 6793 FAX : +(91) 22 2581 2524 6796 9049 EMAIL : info@hdfire.com WEBSITE : www.hdfire.com JANUARY, 2013 PAGE 5 OF 5