Fall Boiler Start-up, Fuel System Tips to keep you Safe

Similar documents
There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are:

Diocese of Cleveland Facilities Services Corporation

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

FINNED WATER-TUBE POOL HEATERS

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

LGB Gas fired boiler

Eclipse 90 UV Scanner Model A Version 1

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS

FINNED WATER-TUBE POOL HEATERS

NOZZLE MIX COMBINATION BURNER NMC200 SERIES

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

Eclipse Self-Check UV Scanner

FGR. Installation, Operation and Startup Instruction Manual FOR FLUE GAS RECIRCULATION SYSTEM. FGR-8 through FGR-22 (25 HP to 1000 HP)

Compliance Guidance for non-technical managers

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

ECLIPSE INFORMATION GUIDE

Pulse Firing Doubles Capacity and Cuts Fuel Costs

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

DIVISION FINNED WATER-TUBE BOILERS

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Columbia Boiler Company

DIVISION FINNED WATER-TUBE BOILERS

NMG NOZZLE MIX GAS BURNERS

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler

Fig. 1 - Unit PGD4, PGS4, WPG4

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

Low pressure boiler* inspection and maintenance

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

User's Infomation Manual

DIVISION FINNED WATER-TUBE BOILERS

BGH Series Hot Surface Ignition Control

Overview of Gas Range Types

USER S INFORMATION MANUAL (2,4)SG13B

Owner s Information Manual

WATER-TUBE POOL HEATERS

Packaged Gas/Electric

The key element for your process

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

Efficient Steam System Design

WATER-TUBE POOL HEATERS

USER S INFORMATION MANUAL

DIVISION FINNED WATER-TUBE BOILERS

Figure 10 or Figure 6

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing

This document was created with FrameMaker 4.0.4

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

User s Information Manual

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

User s Information Manual

PAULIN PRODUCTS INDOOR HEATER

USER'S INFORMATION MANUAL

OPERATING AND MAINTENANCE MANUAL

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

Owner s Guide Installation & Operation

OPERATING INSTRUCTIONS AND OWNER S MANUAL

TERRACE AND PATIO HEATER HLB-2400/ 2650 SERIES

Monitoring Flammable Vapors and Gases in Industrial Processes

USER'S MANUAL PGE Single Package Rooftop

NFPA 85 COMPLIANCES OF BMS: A CASE STUDY OF BOILER CONTROL AT SBM OFFSHORE MALAYSIA COMPANY 1. AHMED ABOUELRISH 2 Universiti Teknologi Petronas

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

User s Information Manual Models: 45, ,000 Btu/hr

ToThePOINT. Best Practices. Best Practice No. 1: Have your boiler inspected regularly by an authorized inspection agency. LOSS CONTROL SERVICES

USER'S INFORMATION MANUAL

NFPA 86 Commitee Inputs Page 1 of 45

Flame Safeguard Fault Code Diagnostics

User s Information Manual Galaxy GG/GX Series, Sentry S/SX Series and Sentinel SE Series Gas Boilers with Continuous Burning Pilot

PACKAGED COMMERCIAL WATERTUBE BOILERS

CSD-1 COMMERCIAL BOILER CONTROLS

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

Originators of the Flexible Water Tube design

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

The Village of Franklin Gas Safety Pamphlet

User s Information Manual

User s Information Manual

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

BURNER MANAGEMENT CONTROLS

HEATEC TEC-NOTE. Operation and maintenance Heatec thermal fl uid heaters industrial series IMPOPRTANT NOTICE! CONTENTS. Publication No.

Owner's Guide to Operating and Maintaining Your Gas/Electric Unit

READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

RS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN

southbend A MIDDLEBY COMPANY INSTALLATION AND OPERATION MANUAL CG214 (E) CG314 (E) CG414 (E) CG220 (E) CG320 (E) CG325 (E) GAS BOILERS MODELS:

SPECIFIC APPLIANCES CHAPTER 6

User s Information Manual

about your house Assessing the Comfort and Safety of Your Home s Mechanical Systems

Good Ideas For Propane Safety

Bert Uneken, Field Engineering Manager Ruben Kranenburg, Technical Support

Fundamentals of a gas fire New Zealand. August 2017

RECOMMENDED PROCEDURES FOR THIRD-PARTY PREVENTATIVE MAINTENANCE PROVIDERS

SPECIFIC APPLIANCES CHAPTER 6

THE ALLIANCE FOR BANGLADESH WORKER SAFETY BOILER SAFETY

Samsung EHS Heat Pump Test

SPECIFIC APPLIANCES CHAPTER 6

E-Z Zone Pack 3+1 And 5+1 Boiler Manifold System

Transcription:

11699 Brookpark Road Cleveland, OH 44130 USA P: 216-749-2992 F: 216-398-8403 www.combustionsafety.com Fall Boiler Start-up, Fuel System Tips to keep you Safe Starting Up Your Boilers? You can t afford to ignore these three fuel-system start-up lessons. Fall is a wonderful season, the nights get a little cooler, the leaves start to change, football season begins, and for some it is time to get the boilers started up. This could be the start of another productive season out of your boilers, or their destruction, thousands of dollars in repair costs, or even explosion and death. Handling a seasonal start-up correctly can make all the difference in the world. Some amount of carnage related to boiler start-ups seems to occur somewhere every year. This kind of tragedy is absolutely unnecessary and can be avoided by carefully reading and communicating the tips that follow. These lessons focus on the boiler s fuel and flame safety systems. Increase your chance of staying alive during the first few seconds of the light-off process and the rest of the season. 1. Your firebox may be full of fuel And one false move could make for a disaster! Never, ever, walk up to a boiler or any piece of combustion equipment that has been down for a long period of time, especially a heating boiler that is been down all summer, and just hit the start button. A firebox concentration of only 4.3 % natural gas can create a flammable mixture. Some valves can leak through 1 cubic foot of gas per hour or more. Consider the consequences of a valve leaking through at this rate for several months while your boiler is laid up. Making a wrong move here and trying to start-up in this condition could make for a catastrophic explosion. There are several shut-off valves in your gas train, which are supposed to be tight. These exist to keep gas out of the firing chamber when the unit is off. However, 60% of lubricated plug valves leak through when in the closed position. In addition, automatic safety shut-off and solenoid valves also leak through when closed. By design, manual lubricated plug valves are nothing more than two pieces of metal with an air gap between them. A tight shut-off seal only occurs when a special sealant is present. This sealant lubricates and seals the surfaces. If this sealant does not exist, the valve body will tend to corrode and lock into a fixed position with the plug. The end result is that you will not be able to move the valve from its fixed position no matter how hard you try. If a bad gas leak is discovered or a fire breaks out, this valve will not be able to be budged.

Page 2 Most sites do not understand the concept of how these valves work and do not have the proper sealant or injection equipment. The process of tightness testing automatic safety shut-off or pilot valves should be completed at least annually. The objective is to measure the rate at which bubbles flow downstream of a supposedly closed valve. This process requires training for it to be performed safely. If you cannot verify that you do not have a hazardous situation on your hands, you should treat the situation as if it is. Carefully insert a flammability meter probe into the firebox and measure the LEL (lower explosive limit) of the firebox atmosphere. If you are even close to the LEL, make sure you safely purge without any possibility of a spark before proceeding. 2. Your safety interlock protection may not be working!!! Time and inactivity are two factors that must be considered during start-up. Inactivity means parts have not moved in a long time. The passage of time invites changes in environmental factors such as moisture and temperature. These two issues alone can make for unwelcome surprises. When parts cool off they come closer to the dew point temperature of the surrounding ambient air, which means moisture will condense on a surface. If that surface is the electrical contact of a switch or a vertical piece of vent pipe, corrosion can occur. Corrosion of components can mean the flaking off of rust that can create wedges between valve seating surfaces. It can also mean switch components get stuck in position due to corrosion, or even cause switch contacts to no longer make and break reliably. Cooled off boiler components and summer breezes will also create a more comfortable living environment for insects and birds, which regularly clog vent line terminations. Start-up is the right time to look for and correct these items. Very few sites conduct regular interlock and safety control testing. In most states, lack of regular testing is against the law. It is especially foolish to not test safeties and interlocks in the case of a cold start-up after a down period. Boiler safety interlocks that require regular testing include the following: a. High and low gas pressure switches b. Low water cut-offs c. High steam pressure switch cut-offs d. Flame scanners e. Air flow proving switches

Page 3 f. Valve proof of closure switches g. Low fire start switches Interlock testing can and should only be done once you are sure the firebox does not contain a flammable mixture. Whoever is doing this testing must be trained and experienced. 3. Fire in the Hole! A Pre-Start Walk Around is a Must! A walk down procedure that trains people to look for obvious problems should be established prior to starting up. For example, purge fans are supposed to move fresh air through the firebox in case gas valves have leaked through. If the fans are dirty or have the Sunday newspaper stuck to the air intake, all bets are off. In these cases the purge may not happen properly. Likewise, if the high and low gas pressure switches, air switches or purge timer are set incorrectly you will have lost their ability to protect you and your equipment. After a thorough walk down, remember there are good and bad places to stand during a light-off. One should never stand in front of a burner or any bolted connection like a flue stack. Likewise, some boilers have relief panels built in, which will come apart and off in the case of a firebox explosion. In the case of fire tube boilers for example, it is usually best to stand to the side. There have also been a number of people who have lost their vision looking into sight view ports during light-offs. This is a place to look only with eye protection, and never, ever, during a light-off. Always move the view port sight shield, if one exists, and test for hot firebox gasses first before putting your eyes and head in harm s way. When the pilot and main flame are lit, immediately look for items such as the quality of the flame and the gas pressure stability entering the burner. A good flame is full and complete along the burner ring. It has movement and is blue with yellow and/or orange tips. If your flame is unstable (going on and off in places), lacks movement, is bright orange or yellow and/or you see soot coming out of the stack, you have major problems. These conditions occur because the air-fuel mixture is too rich. If the unit is shut down in this condition, do not try to restart again without allowing a cool down period and the fuel rich atmosphere to dissipate.

Page 4 Remember, flame scanners and flame detection equipment are not designed to distinguish between good flames and bad flames. This has to be done by a trained human eye. The process for walking down the system and knowing what to look for should become part of a well-documented start-up/shut down procedure. Include digital pictures of the control panels with close ups of the buttons and labels. Everything should be explained in clear and simple terms that anyone operating the equipment understands. The issues discussed above are not all-inclusive but make for a great beginning. Many consider steam and the water side related start-up issues, but do not consider basic fuel and combustion system issues until it is too late. Consider the ASME (American Society for Mechanical Engineers) CSD-1 standard for more details regarding interlocks, testing and good practices; it provides important safety information regarding controls and safety devices for automatically fired boilers between 400,000 and 12,500,000 btuh input. This code has been adopted as law in most states. For larger equipment, NFPA 85 (National Fire Protection Association) is a good reference. Remember, start-up is the most dangerous few minutes in the life of each boiler and operator. Implementing the lessons provided here can make for a time to enjoy the wonders of fall. CEC Combustion Safety, LLC has been in business since 1984. With engineers and staff members that sit on Code committees such as ASME CSD-1, NFPA 56, NFPA 85, NFPA 86, and NFPA 87, our inside expertise is integrated within all of our practices and our global reach ensures that customers around the world are kept safe. CEC offers Testing and Inspections, Engineering & Upgrades/Retrofits, Gas Hazards Management, Training, and Field Services for all industrial facilities and different types of fuel fired equipment. By assisting organizations and their personnel with the safe maintenance and operation of their combustion equipment, CEC aims to save lives and prevent explosions while increasing efficiency and reliability of combustion equipment. Contact CEC at +1 216.749.2992 or visit www.combustionsafety.com for additional information.

Page 5