LMR Electric Fire Pump Controllers Features

Similar documents
LMR Electric Fire Pump Controllers Features

FDF Foam Pump Controllers Features

FT60 Reduced Voltage - Autotransformer

Transfer Switch Features

Transfer Switch Features

DIESEL Engine Fire Pump Controllers Features

FDJ SERIES Jockey Pump Controllers Features

FD30 Full Voltage - Across the Line July 2011

Customer Connection Terminals Connection terminals for external customer connections, are located at the top of the Power I/O board.

DIESEL Engine Fire Pump Controllers Features

DIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers

Fire Pump Controllers Foam (Additive) Controllers

FT40 Reduced Voltage - Part Winding. Electrically and Mechanically

FT20 Full Voltage - Limited Service. Electrically and Mechanically

Drawing Submittal Package

Fire Pump Controllers Medium Voltage Controllers

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Drawing Submittal Package

Soft Start Series MP700 Solid State, Reduced Voltage

Technical Data Submittal Document

Across-the-Line SERIES MP300 Combined Manual and Automatic

Remote Alarm Panels Features

Variable Frequency Drive SERIES MP800 VFD

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE

EATON LMR Plus Electric Fire Pump Controllers

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

Fire Pump Controller. For Electric Motor Driven Fire Pumps. Wye Delta Reduced Current Types

Technical Data Submittal Documents

Centro-Matic Automated Lubrication Systems System Controls

EATON DFDAP-M / FDAP-M Remote Alarm Panels

Microprocessor Based Wye-Delta Reduced Current Type Starting

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

MANUAL FOR MODEL MP600 HIGH VOLTAGE ELECTRIC MOTOR DRIVEN FIRE PUMP CONTROLLERS

Guide Specification Model CTG Automatic Transfer Switch

FTA550F JOCKEY PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

Options for Diesel Fire Pump Controllers

AS950 REFRIGERATED SAMPLERS

FTA550 JOCKEY PUMP CONTROLLERS

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

SECTION ROTARY-SCREW WATER CHILLERS

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

PILOT SERIES MPT700TS

CONTENTS AUTOMATIC TRANSFER SWITCHES

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

SECTION AUTOMATIC TRANSFER SWITCHES

AS950 PORTABLE SAMPLERS

INSTALLATION AND MAINTENANCE MANUAL FOR ELECTRIC FIRE PUMP CONTROLLERS MODEL GPX

SECTION Fire Pumps

PARAGON Commercial Refrigeration Controls

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

SECTION AUTOMATIC TRANSFER SWITCHES

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

- Data Brochure Addendum

CONSTANT PRESSURE CONTROLLER

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

.2 Section Waste Management and Disposal.

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

SECTION FIRE PUMPS 1.00 PART 1 & GENERAL Description of Work. A. Provide pumps for fire suppression Section Includes

1 Dimensions Installation Mains/boosted cold water inlet Connection to the system Drain Dimension for fixing 6

P.C. Simonton & Associates, Inc. Consulting Engineers. Paul C. Simonton

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

MANUAL FOR MODEL FD4 FIRE PUMP CONTROLLERS

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

MPT Electric Fire Pump Controller

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

SECTION FIRE PUMP AND CONTROLS

Theory of Operation: M9/D & M11/D

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

MPT Electric Fire Pump Controller

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

ULTRA-SAFE Explosion-proof Duct Heaters

University of Houston Master Construction Specifications Insert Project Name SECTION FIRE PROTECTION PUMPS PART 1 - GENERAL

"ESDDR" Series Electric Humidifier

- Data Brochure Addendum

ARM SERIES Switching Relays With Priority

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

NS (A) ECN

Instruction manual. WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules

Commercial and Light Industrial Fire Alarm Control Panel

MODEL YVAA EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST CUSTOMER: LOCATION: ADDRESS: CUSTOMER ORDER NO: PHONE: JCI CONTRACT NO: JOB NAME:

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

"VIP 2" ADVANCED LUBRICATION CONTROLLER

Contents. FX-1 Operations Manual Micro Air Corporation 124 Route 526 Allentown, NJ 08501

Installation and Operation Manual

EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST TEL NO: ORDER NO: CONTRACT NO:

- Data Brochure Steam Control 279

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

CR1 Series Triton Corrosion Resistant Washdown Heaters

TEMPERATURE & PRESSURE CONTROLS

Power Flame Incorporated

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

Transcription:

1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller. The on/off switch, feed and reset buttons are front accessible. A bi-color status LED is also visible on the front of the printer. Green indicates - Printer Operational while yellow indicates - Out of Paper. Sequential Start Timer The sequential start timer is used to program a start delay after an automatic start request. This function is used for staging the start of pumps in a multiple pump application and also in Diesel backup applications. Weekly Test Timer The weekly test timer allows the user to set the controller to automatically start and stop the controller once per week. The number of weeks between tests is set via the front keypad. The weekly test date and time can be viewed on the LCD display. Product Description The FD40 LMR s are a full service, part winding reduced voltage controller. A part winding fire pump controller reduces the starting current by up to 40% while maintaining up to 50% motor starting torque. The FD40 is the most economical method of reduced voltage starting, however, requires a special motor wound for part winding starting. The FD40 can be programmed for either fully automatic or semi-automatic operations. Product Microprocessor Control EATON Cutler-Hammer LMR s are microprocessor based. All events surrounding the operation of the controller are stored within the memory, thus giving the ability to diagnose and troubleshoot problems based on an actual history of events. Events are time and date stamped. A main display unit provides a read-out of parameters such as current pressure, volts and amps and will display error messages as well as provide alarm indication. A status report is available which provides a record of the state of the controller as it was left after commissioning. The report can be printed locally via the printer / recorder. Alarm & Status Indication The display panel is equipped with nine red Alarm LED s and nine green Status LED s which indicate various functions and operations of the controller. The membrane keypad has curved dome windows which allow viewing from a wide angle. LCD Message Retrieval The 2 line liquid crystal display allows viewing of all messages and event information without opening the front door of the controller. Messages can also be downloaded to a laptop computer via the communications port located on the top of the main microprocessor board. Last 2048 Messages The internal microprocessor stores the most recent 2048 messages in it s memory. The messages can be printed, viewed on the LCD screen or downloaded to a laptop. Each message is time and date stamped. The LCD display acts as a paperless chart recorder. Elapsed Time Meter The LMR monitors and records the run time of the motor, in hours, whenever the pump is running. The actual run time can be viewed on the LCD display in 1 hour increments. Number of Operations Counter The LMR controller monitors and records the number of times the pump has started. The actual count can be viewed on the LCD display. Volts and Amps Display The LCD display located on the main display panel, simultaneously indicates the voltage and amps on all three phases of power coming into the controller. Pressure Transducer: 0-600 psi Each LMR controller is equipped with a stainless steel, 0-600 psi pressure switch capable of withstanding a momentary surge pressure of 1000 psi. NEMA 2 Enclosures All LMR controllers come standard with NEMA 2 enclosures unless otherwise ordered. Available options include: NEMA 3R, 4, 4X, 12. NEMA Rated Contactors NEMA rated Freedom or A200 Series EATON Cutler-Hammer contactors are used in all LMR fire pump controllers. A wide variety of coil voltages are available for domestic and international use. Emergency Start Operator A mechanically operated emergency start handle activates the motor contactor independent of any electrical control circuits or pressure switch input. Extra Set of Form-C Contacts for Phase Reversal and Phase Failure The phase reversal and phase failure relays come standard with an extra set of contacts that can be used for remote alarm indication. Run Period Timer The run period timer is built into the LMR microprocessor and can be accessed via the membrane / keypad. It is programmable from 0-45 minutes and should be reset to ten (10) minutes when the controller is placed in service.

1-2 Product Status & Alarm Indication Additional Output Relay An additional output relay labeled Future #1, can be user programmed to operate for nine (9) different functions. Programming is done in the LMR menu using the membrane / keypad. Common Alarm Relay and Contacts The LMR controller has a common alarm relay which de-energizes whenever there are any alarm conditions present. This relay is energized under normal conditions and has LED status indication on the main relay board. Pressure 102 PSI Status LED s Power On Pump Running RPT Timer Sequence Timer Local Start Remote Start Deluge Valve Interlock On Low Pressure Alarm LED s Phase Reversal Phase Failure Fail To Start Undervoltage Overvoltage Relief Valve Discharge Locked Rotor Trip Low Suction Pressure Emergency Start Technical Data and Specifications Line Terminals (Incoming Cables) Line Terminals on Main Isolation Switch (Incoming Cables) LINE VOLTAGE 200-208 220-240 * 380-415 440-480 550-600 Max. Hp 30 30 60 75 100 40 40 100 100-75 75 150 200 200 100 125 200 250 300 150 200 350 400 400 * Coils available: 380V-50Hz, 380V-60Hz, 415V-50Hz, 415V-60Hz. Qty. & Cable Sizes Service Entrance GND.LUG Qty. & Cable Sizes (1)#14-1/0 PER (CU/AL) (1)#14-2/0 (CU/AL) (1)#4-4/0 PER (CU/AL) (1)#14-2/0 (CU/AL) (1)#3-350MCM (CU/AL) (1)#4-350MCM (CU/AL) (2)3/0-250MCM (CU/AL) (2)#4-350MCM (CU/AL) (2)250-350MCM (CU/AL) (2)#2-600MCM (CU/AL) Load Terminals (To Motor) Load Terminals (To Motor) LINE VOLTAGE 200-208 220-240 380-415 440-480 550-600 Max. Hp 25 30 60 60 75 50 60 100 125 150 75 100 200 200 250 150 200 350 400 400 For Proper Cable Size Refer to National Electrical Code NFPA-70 Qty. & Cable Sizes (1)#14-#3 PER (CU/AL) (1)#14-1/0 PER (CU/AL) (1)#6-250MCM (CU/AL) (2)1/0-250MCM (CU/AL) Standards & Certification The meet or exceed the requirements of Underwriters Laboratories, Underwriters Laboratories Canada, Factory Mutual, the Canadian Standards Association, New York City building code, CE mark requirements and are built to NFPA 20 standards.

1-3 Dimensions Standard Enclosure - Type NEMA 2, 3R, 4, 4X, 12 Motor Hp 5-40 5-50 5-75 5-100 5-100 Line Voltage * Coils available: 380V-50Hz, 380V-60Hz, 415v-50Hz, 415V-60Hz. Withstand Rating Standard Intermediate High 200-208V 220-240V 380-415V 440-480V 550-600V 25,000 150,000 200,000 350 (159) Approx. Weight Lbs. (Kg) 1. All enclosures finished in FirePump red. 2. Cable Entrance either top or bottom. 3. Standard Enclosure type NEMA 2.

1-4 Dimensions Standard Enclosure - Type NEMA 2, 3R, 4, 4X, 12 Motor Hp Line Voltage Withstand Rating Standard Intermediate High Approx. Weight Lbs. (Kg) A B C D 50-100 60-125 200-208V 220-240V Consult Factory Consult Factory 580 (263) 47.85 (1215) 37.23 (946) 11.00 (279) 27.10 (688) 100-200 * 380-415V 125-250 440-480V 125-300 550-600V 25,000 35,000 125-150 150-200 200-208V 220-240V Consult Factory 685 (311) 53.85 (1368) 43.23 (1098) 21.74 (552) 33.10 (841) 250-300 * 380-415V 300-400 440-480V 350-500 550-600V 25,000 35,000 * Coils available: 380V-50Hz, 380V-60Hz, 415V-50Hz, 415V-60Hz. 1. All enclosures finished in FirePump red. 2. Cable Entrance either top or bottom. 3. Standard Enclosure type NEMA 2.

1-5 Dimensions Standard Enclosure - Type NEMA 2, 3R, 4, 4X, 12 Motor Hp 200-250 250-300 350-500 450-600 550-700 Line Voltage Withstand Rating Standard Intermediate High 200-208V 220-240V 380-415V 440-480V 550-600V 25,000 Consult Factory 35,000 Consult Factory 865 (392) * Coils available: 380V-50Hz, 380V-60Hz, 415V-50Hz, 415V-60Hz. Approx. Weight Lbs. (Kg) 1. All enclosures finished in FirePump red. 2. Cable Entrance either top or bottom. 3. Standard Enclosure type NEMA 2.

1-6 Electrical Wiring Schematic

Options - Wiring Diagram 1-7 Main Terminal Block: TB1 Typical Connection 1. Terminal 49 is common to all dry contact inputs. DO NOT APPLY A VOLTAGE ON THESE TERMINALS 2. Contacts shown in de-energized state (Fail Safe). Relay Card 1. To Control Circuit 2. Spare for Customer Connections 3. To TB1 4. To Shunt Trip 5. Contacts Shown in De-Energized State - (Fail Safe)

1-8 Catalog Number Selection FD40 Part Winding Catalog Numbering System FD LMR Type Options 40 = Part Winding A - Built-in Alarm System B - Alarm Bell C1 - Extra Contacts "Pump Run" (one N.O. std.) C2 - Extra Contacts "AC Power Failure" (two sets std.) C3 - Extra Contacts "Phase Rev." (two sets std.) Horsepower C4 - Remote Contacts (2 Form C) Low Reservoir 15 40 100 250 450 C5 - Remote Contacts (2 Form C) High Reservoir 20 50 125 300 500 E1 - NEMA 3R - Raintight Enclosure 25 60 150 350 *600 E2 - NEMA 4 - Watertight Enclosure (Ref Dwg. Page 1-3) 30 75 200 400 *700 NEMA 4 - Watertight Enclosure (Ref Dwg. Page 1-4, 1-5) * Consult Factory for pricing. E3 - NEMA 12 - Industrial Dust Tight Enclosure E5 - NEMA 4X - 304 Stainless Steel Enclosure (Ref. Dwg.page 1-3) NEMA 4X - 304 Stainless Steel Enclosure (Ref Dwg. Page 1-4, 1-5) E8 - Tropicalization Voltage E9 - NEMA 4X - Painted Steel (Ref. Dwg. Page 1-3) A = 200-208V 60 HZ NEMA 4X - Painted Steel (Ref. Dwg. Page 1-4, 1-5) B = 220-240V 60 HZ E10 - NEMA 4X - 316 Stainless Steel Enclosure (Ref. Dwgs Page 1-3) C = 380-415V 50/60 HZ NEMA 4X - 316 Stainless Steel Enclosure (Ref. Dwg. Page 1-4, 1-5) D = 440-480V 60 HZ EX - Export Crating E = 550-600V 60 HZ F - Floor Stand (Standard c/w floor mounted enclosures) F2 - Floor Stand - 2 Inch Height H - High Withstand Rating (refer to tables) I - Intermediate Withstand Rating (refer to tables) P7 - Low Suction Pressure Switch c/w Pilot Light LMR Series P8 - Low Suction Shutdown (Requires P7) Microprocessor Control P10 - Pressure Transducer - Sea Water Rated P13 - Externally Mounted Pressure Transducer R1 - Space Heater (120 / 220V) R2 - Space Heater c/w Thermostat Language R3 - Space Heater c/w Humidistat L1 = English R4 - Low Pump Room Temperature Switch and Pilot Light L2 = French X1 - Printer/Pressure Recorder L5 = Spanish X2-4 - Inch Chart Recorder (10-300 psi fresh water)