3RD GENERATION PANEL RADIATOR

Similar documents
3RD GENERATION PANEL RADIATOR

3RD GENERATION PANEL RADIATORS

PANEL RADIATOR RANGE. inside

PANEL RADIATOR RANGE. inside

DESIGNER RADIATORS. July

DESIGNER RADIATOR RANGE

DESIGNER RADIATORS.

LOW SURFACE TEMPERATURE RADIATORS

UK PRICE GUIDE. January Complete with Technical Specifications for ROUND TOP, COMPACT, LST, AND TOWEL RADIATORS

LST i PLUS. Safety Series

LST STANDARD. Safety Series

Heating Emitters. Find the right radiator for each room. Radiators Towel Warmers Towel Warmer Valves 295

Introducing LST. The low surface temperature range. dimplex.co.uk. February 2015.

Sovereign Double CC/DD

PLAN KLASIK LINE KLASIK

LST Plus Vertical. Plus Vertical 3 models. Lengths: 560mm, 660mm & 760mm. Outputs: 1335 to 1862 watts, 4555 to 6353 Btu/hr

Radiators, Towel Warmers and Trench Heating

Radical CPD BIM.

(UK) Date : February 2016 NOTE: PLEASE LEAVE COPIES OF THESE INSTRUCTIONS AND ANY DRAWINGS WITH THE END USER.

Heating. Our range of designer radiators and towel rails, brings fashion and function together beautifully. By Style

MARCH 2012 ISSUE 2 DYNAMIC. The only electronically controlled Electric Radiator with dynamic looks, dynamic performance and dynamic efficiency.

planal vertical The ultimate modern statement room, Planal Vertical radiators and exciting, flexible way to make an impression

Energy Saving Series RADICAL

VITA ECO. Save money & energy. Highly efficient radiator saving up to 10.5% on fuel bills, at a cost effective price. 03 / 06 RANGE.

OVERVIEW OF THE ELECTRIC RADIATORS RANGE

Panel Radiators. Installation and operating instructions. ThermaRad Classic.

MYSON NEW MYSON. Products for heatingthroughinnovation. Range Brochure September 2011

LEADING THE WAY THINGS TO CONSIDER PRODUCT RANGES COLOURS FITTING QUOTE SERVICE

Photos Work bench Fume hood Plaster room Raw materials coating process Construction of base cabinets Wall cabinets Hinge system Drawers runner System

enviroblinds external blinds & shutters the secret to low carbon comfort

T6 - Centrally Connected & VONOPLAN T6.

FREEDOM 2019.EX CZ - 21/11/18

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

2 DESCRIPTION OF SYSTEM COMPONENTS

PANEL RADIATORS DESIGN RADIATORS TOWEL WARMERS.

Hudevad P5. Technical datasheet

Safe Heating in Sheltered and Social Housing

Q-RAD ELECTRIC RADIATOR

07/ OUR COLLECTION OF DESIGNER RADIATORS AND TOWEL RAILS INSPIRE WARMTH AND ELEGANCE IN ANY BATHROOM. HEATING20. guarantees unless otherwise stated

LANDLORDS & LETTINGS VENTILATION SOLUTIONS

Sargasso Range. A new range of radiant panels for heating commercial applications

Safe Heating in Prisons and Secure Accommodation

Infrared Systems. The Sun s Warmth For Your Home... The Clean Heating System. Infrared Systems. E-Tech Infrared Systems Ltd

6ELECTRIC ELECTRIC HEATING ELECTRIC HEATING

RADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

Commercial Heating Domestic Heating

at in Bathroom radiators are where fashion and function come together in perfect harmony. With everything

Pedestal Range. Installation and user manual. Kiosk. Trafalgar. Tube. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

VERTICAL VONOVA & VERTICAL VONOPLAN. 20 VERTICAL VONOVA & VERTICAL VONOPLAN PANEL RADIATORS. VERTICAL VONOVA Type 20. VERTICAL VONOPLAN Type 20.

Elegant design with the high performance heating technology of tomorrow - today. Electric Combination Radiator Systems. Elektroheizung GmbH & Co.

Providing Natural Solutions to Heating

x131226_manissa_inset_p10_sw_x131226_manissa_inset_p10_sw 05/03/ :50 Page 1 Heating Products 01

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes

Elegant design with the high performance heating technology of tomorrow - today. Electric Combination Radiator Systems Elektroheizung GmbH & Co.

GRANGE CAST IRON RADIATORS COMMERCIAL HEATING SOLUTIONS

Spring Ireland EUR. Merchandising Solutions

Range Brochure July heatingthroughinnovation.

OLSBERG. Our Electric Heating Range. Dynamic Storage Heaters. Static Storage Heaters. Direct Heating

DESIGNER PRODUCT GUIDE

VIII. Heaters Mobile Climate Control 121 MCC Reference Manual 2014

FORCEFLOW. 900 Series Fan Convectors

RADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

Remote Control Garage Doors

FLEXSON WALL MOUNT FOR SONOS PLAY:1

We have replacements! Introducing the NEW Macon Controls EVO, VAO/VAC and EVO-Z

Presentation new platform products

panel plus horizontal wall-mounted

Home & Meeting Room Audio Multiroom Multi-Zone Audio

Vented systems explained Performance without compromise Vented System (Gravity Fed) Positive Head Systems

experience We carefully design each individual installation to optimise performance Good underfloor heating explained

Fully Compliant LOW SURFACE TEMPERATURE PRODUCT INSIDE. With NHS. Guidelines THERMAL INERTIA RADIATORS

Bennett Scientific Limited Clifton Water baths

Make Every Room In Your Home WARM AND COMFORTABLE With Rinnai Heating Solutions.

Sill Line Perimeter Casing. Warmline Trench Heating. Vectair Natural Convectors. Spirally Wound Gilled Tube

EFG ENERGY OPTIMISING SYSTEMS

The simple solution to a daily challenge

RFE PLUS RFCE PLUS. Electric Radiator with Digital Control & Programmer. 430mm High Conservatory Electric Radiator with Digital control & Programmer

Manufacturers of Cast Iron Radiators. Beaumont

Sun Ray Electric Radiators Stylish, Efficient, Low Energy

Talos Steel Range. T: +44 (0) F: +44 (0) E: W:

Our Guarantee. The key to good service is communication. We believe this starts from that first call until the kitchen is in full operational use.

The Ultimate Solution for Electric Central Heating. Fusion. Comet

ELNUR HISTORY. Let us invite you to meet ELNUR and experience the values and benefits that our GABARRÓN products will bring to your life.

Inspiration PVCu Windows & Doors

Automatic Water Boilers

NEW Slider24. No other sliding patio comes close...

Optima Compact Touchscreen Swimming Pool Heater with Ultra Efficient Titanium Heating Elements 3-kW to 24-kW

Titan Optima &Titan Optima plus Swimming Pool Heater with Ultra Efficient Titanium Heating Elements

Waste less energy...

The problem with other hand dryers

New Zealand Sales Hotline: Sales Fax:

sensations window & door range

Introducing Jaga Heating Products

DOORS WINDOWS GARAGE DOORS ROLLER SHUTTERS RETRACTABLE GRILLES BROCHURE.

creative thinking : powerful solutions The new True Energy Vaccine Refrigerator with Sure Chill technology

The Proven Performer for the Hospitality Sector

www

INTRODUCTION HOW DO RADIANT PANELS WORK? A common misconception, even among heating professionals, is that heat rises. In fact, hot air rises and cold

Consumer Features & Benefits of Energy Efficient Products

Space Saver. Installation and user manual SS3 SS5 SS7 SS9. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

Transcription:

3RD GENERATION PANEL RADIATOR HIGHEST HEAT OUTPUT LOWEST RUNNING COST SMALLEST CARBON FOOTPRINT ROI - April 2018

02 CONTENT Why choosing QRL Radiator Group? 01 The Future of Radiators, Today 02-03 HI-LO ROUND TOP Range Overview 04 Technical Specifications 05 Product Codes and Prices 06-07 HI-LO COMPACT Range Overview 08 Technical Specifications 09 Product Codes and Prices 10-13 COMPLA Range Overview 14 Technical Specifications 15 Product Codes and Prices 16-17 LIGNA Range Overview 18 Technical Specifications 19 Product Codes and Prices 20-21 LST Range Overview 22 Technical Specifications 23 Product Codes and Prices 24-28 ACCESSORIES & GENERAL SPECIFICATIONS LST Accessories 29 Radiator Feet 30 General Specifications 31 April 2018 - Republic of Ireland While every care has been taken to ensure the accuracy of information, QRL Radiator Group will not be liable for any errors which may occur. We reserve the right to alter any of the specifications given in this publication without prior notice. All prices are correct at the time of going to print and maybe subject to change.

01 WHY CHOOSING QRL?... QRL Radiator Group manufactures high performance steel panel radiators and a complete range of interior designer radiators. For more than 50 years, our radiators have been the better choice for homes and businesses across the UK and Ireland. Selecting a QRL product means choosing unparalleled quality, advanced technological capabilities and independently certified with industry leading heat outputs. 100% manufactured in South Wales, Europe s most advanced radiator manufacturing facility, you can be assured that every single one of our radiators undergoes rigorous quality control tests in line with EN442 compliance. We are also the only radiator manufacturer listed on the Energy Saving Trust register. Better performance Design and innovation are top of the agenda for our engineering experts. We ve taken radiator technology into a whole new generation for performance and efficiency that simply can t be beaten. Our third-generation radiator technology enables us to manufacture one of the best performing panel radiators on the market today. More convector fins and narrower water channels than any other competitor mean that our radiators offer the highest heat transfer with the least water to heat. Better service Our customers are our number one priority and we want every experience you have with our people and products to exceed your expectations. We have recently invested heavily in our customer service support team to be on hand to answer your questions. This will ensure that your order arrives in full and on time as well as providing all the expert technical support you need after it arrives. In addition, our fully-automated on-site warehousing systems enables us to hold high stock levels for you and we offer one of the fastest delivery times. Verified by EST QRL Radiator Group is the first radiator manufacturer to have had its output performance independently verified by the Energy Saving Trust. EST provides an independent verification of manufacturers product performance data to develop factually informative consumer-facing claims. Here are some of our verified claims*: QRL third generation radiators have one of the best heat outputs on the market even at lower water temperatures. This makes them the ideal match for lower temperature renewable heating systems, such as heat pumps. QRL third generation radiators have one of the best dynamic responses on the market, which means they heat up quicker than other radiators. Performance: a lower water content; high heat transfer; QRL third generation radiators are a great choice for heat output. *Verified by EST: heat output at a Δ T 50 and 30 C for QRL T11 and T22 Compact and Round Top radiators (size: 600x1000mm), compared to the main market competitors. Using British Standard testing data from EN 442-1:2014 standard. Correct as of July 2016 and valid until July 2018. If you d like to speak to one of our dedicated customer support team, just give us a call on 1800 882 332 or email sales@qrl-radiators.com

02 The Future of Radiators, Today THE FUTURE OF RADIATORS, TODAY... We re proud to say that our Hi-Lo radiators are the most efficient panel radiators available on the market today. By efficiency we mean two things: 1. The highest heat output (per square metre) on the market 2. Bigger energy savings and lower operating costs for our customers It s all thanks to our unique third-generation technology: developed by our industry specialists to push the boundaries of heating performance. Say hello to the world s only third generation radiator Ultimately, the difference between outdated and modern radiator technology is the way it transfers heat. QRL third-generation panel radiators have more efficient convection and a lower water content. This means faster heat-up and less water to heat in the first place resulting in better performance. In technical terms, it all boils down to the radiator s waterway pitch (the distance between its vertical water channels) and the configuration of its convector fins (which transfer heat). First generation (1960s) Design: 40-54mm pitch, hand-welded connections and no convector fins Performance: With more water to heat and fewer channels, heat transfer is very poor Availability: First-generation products are now obsolete 100mm/4 Generation 1a (1970s) Design: 40-54mm pitch, M -shaped convector fins and projection back-welded connections Performance: Improved efficiency, but still very outdated by modern standards Availability: A handful of manufacturers still make them Second generation (1980s) Design: Simple, waterway-welded fins and a reduced 33.3mm pitch Performance: Enhanced output and efficiency, but far outstripped by Hi-Lo third-generation technology Availability: Most other brands make second-generation radiators Third generation (present) Design: The most fins, and the smallest waterway pitch (at just 25mm) Performance: With a lower water content and unrivalled heat transfer, third-generation radiators are the better choice for heat output Availability: Unique to QRL

The Future of Radiators, Today 03 Smaller in size, high in heat output 1200mm 600 mm 33 mm Size 600 x 1200 mm Larger radiator MORE Steel Larger carbon footprint Output 2694 W/m 2 1940 W Poorer performance HIGHER Cost 24 water channels each 600 mm 25 mm Size 600 x 1000 mm Smaller radiator Output 3190 W/m 2 1914 W 1000mm 200mm shorter No 1 for efficiency, even with low water temperature system Output 1709 W Less heat MORE Water to heat SLOWER Heat-up time LARGER Carbon footprint HIGHER Running cost 33 mm 600 x 1000mm second-generation radiator (double convector) 25 mm Better performance LESS Steel Smaller carbon footprint LOWER Cost 600 x 1000mm third-generation radiator (double convector) Output 1914 W More heat LESS Water to heat FASTER SMALLER Carbon footprint LOWER Running cost

04 Hi-Lo Round Top *Verified by EST: heat output at Δ T50 C and 30 C for Hi-Lo T11 and T22 Round Top radiators (size: 600x1000mm), compared to the main market competitors. Using British Standard testing data from EN 442-1:2014 standard. Correct as of July 2016 and valid until July 2018. HI-LO ROUND TOP... The Hi-Lo Round Top is our signature product. Engineered by our industry experts and featuring our unique third-generation technology, it is the better choice for performance, quality and durability on the market today. Highest heat output (per square metre) - up to 10%* higher than competitor radiators of the same size Lowest water content (L/kW) for the best dynamic response on the market Best choice with low temperature heat sources such as heat pumps Finished with durable epoxy polyester powder paint in white RAL9016 Manufactured and tested in accordance with EN442 Full 10-year warranty All sizes held in stock. Available in a large variety of sizes and styles - single panel single convector (T11), double panel plus (T21), double panel double convector (T22).

Hi-Lo Round Top 05 Bracket Lug Location Mounting Details Note: Dimensions H1, H2 and H3 refer to the lugs on Double Panel Plus and Double Convector radiators. Dimensions J1, J2 and J3 refer to the lugs on Single Convector Radiators. Single Convector T11 Double Panel Plus T21 Double Convector T22 Mounting Details (mm) Radiator height 'B' 300 400 500 600 700 Bracket height 'C' 137 237 337 437 537 Connection centre 'D' 253 353 453 553 653 Bracket Lug Locations (mm) Radiator length 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1800 2000 Tapping-to-tapping A 295 395 495 595 695 795 895 995 1095 1195 1295 1395 1495 1595 1795 1995 H1 72.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 J1 85 135 160 160 160 160 160 160 160 160 160 160 160 160 160 160 H2 150 150 250 350 450 550 650 750 850 950 1050 1150 1250 1350 775 875 J2 125 125 175 275 375 475 575 675 775 875 975 1075 1175 1275 750 850 H3 - - - - - - - - - - - - - - 775 875 J3 - - - - - - - - - - - - - - 725 825 Quantity 4 4 4 4 4 4 4 4 4 4 4 4 4 4 6 6 Water Content Height 300mm 400mm 500mm 600mm 700mm L/m Single Convector 1.81 2.24 2.67 3.10 3.53 Double Panel Plus 3.60 4.47 5.33 6.20 7.07 Double Convector 3.50 4.37 5.23 6.10 7.00 Radiator Dry Weight Height 300mm 400mm 500mm 600mm 700mm kg/m Single Convector 8.53 11.44 14.35 17.27 20.16 Double Panel Plus 14.90 19.04 23.75 28.47 33.18 Double Convector 16.92 22.73 28.55 34.36 40.18 Test pressure: 13 bar Max. operating pressure: 10 bar

06 Hi-Lo Round Top T11 T21 T22 Nominal Length Single Convector Double Panel Plus Double Convector Height mm inch Code Watts BTU/hr List Price Code Watts BTU/hr List Price Code Watts BTU/hr List Price 300mm 12 400 16 Q11304RT 226 770 53.11 Q21304RT 339 1156 65.40 Q22304RT 446 1522 96.58 500 20 Q11305RT 282 962 62.30 Q21305RT 424 1445 71.58 Q22305RT 558 1903 62.25 600 24 Q11306RT 338 1155 65.56 Q21306RT 508 1734 77.77 Q22306RT 669 2283 79.95 700 28 Q11307RT 395 1347 94.94 Q21307RT 593 2024 83.94 Q22307RT 781 2664 106.69 800 31 Q11308RT 451 1540 81.46 Q21308RT 678 2313 91.64 Q22308RT 892 3044 113.09 900 35 Q11309RT 508 1732 102.48 Q21309RT 762 2602 96.43 Q22309RT 1004 3425 119.52 1000 39 Q11310RT 564 1925 88.41 Q21310RT 847 2891 102.54 Q22310RT 1115 3805 127.50 1100 43 Q11311RT 620 2117 115.29 Q21311RT 932 3180 111.25 Q22311RT 1227 4186 139.05 1200 47 Q11312RT 677 2310 96.35 Q21312RT 1016 3469 119.97 Q22312RT 1338 4567 152.39 1400 55 Q11314RT 790 2695 140.45 Q21314RT 1186 4047 137.40 Q22314RT 1561 5328 187.92 1600 63 Q11316RT 902 3080 136.09 Q21316RT 1355 4625 155.20 Q22316RT 1784 6089 199.84 1800 71 Q11318RT 1015 3645 147.55 Q21318RT 1525 5203 170.60 Q22318RT 2007 6850 227.02 2000 79 - - - - - - - - Q22320RT 2231 7611 247.74 Nominal Length Single Convector Double Panel Plus Double Convector Height mm inch Code Watts BTU/hr List Price Code Watts BTU/hr List Price Code Watts BTU/hr List Price 400mm 16 400 16 Q11404RT 293 1001 49.43 Q21404RT 427 1457 73.59 Q22404RT 562 1919 64.07 500 20 Q11405RT 367 1251 34.65 Q21405RT 534 1821 81.71 Q22405RT 703 2399 74.04 600 24 Q11406RT 440 1501 40.30 Q21406RT 640 2185 89.79 Q22406RT 844 2879 84.11 700 28 Q11407RT 513 1751 44.94 Q21407RT 747 2549 97.89 Q22407RT 984 3358 92.98 800 31 Q11408RT 586 2001 48.58 Q21408RT 854 2913 106.10 Q22408RT 1125 3839 103.91 900 35 Q11409RT 660 2252 54.02 Q21409RT 960 3278 - Q22409RT 1265 4319 114.09 1000 39 Q11410RT 733 2502 57.97 Q21410RT 1067 3642 123.66 Q22410RT 1406 4799 119.50 1100 43 Q11411RT 806 2752 63.26 Q21411RT 1174 4006 - Q22411RT 1547 5279 127.30 1200 47 Q11412RT 880 3002 69.64 Q21412RT 1280 4370 143.64 Q22412RT 1687 5758 137.59 1400 55 Q11414RT 1026 3502 85.71 Q21414RT 1494 5098 164.89 Q22414RT 1968 6718 179.17 1600 63 Q11416RT 1173 4003 97.06 Q21416RT 1707 5827 186.56 Q22416RT 2250 7679 209.78 1800 71 Q11418RT 1319 4503 108.25 Q21418RT 1921 6555 209.24 Q22418RT 2531 8638 232.61 2000 79 Q11420RT 1466 5003 120.21 - - - - Q22420RT 2812 9597 257.99 Nominal Length Single Convector Double Panel Plus Double Convector Height mm inch Code Watts BTU/hr List Price Code Watts BTU/hr List Price Code Watts BTU/hr List Price 500mm 20 300 12 Q11503RT 267 911 51.02 Q21503RT 381 1300 71.20 Q22503RT 504 1721 94.78 400 16 Q11504RT 356 1215 53.44 Q21504RT 508 1734 57.61 Q22504RT 672 2295 71.14 500 20 Q11505RT 445 1519 38.18 Q21505RT 635 2167 67.80 Q22505RT 841 2869 75.34 600 24 Q11506RT 534 1823 44.48 Q21506RT 762 2601 80.93 Q22506RT 1009 3442 89.91 700 28 Q11507RT 623 2126 50.92 Q21507RT 889 3034 95.46 Q22507RT 1177 4016 106.06 800 31 Q11508RT 712 2430 57.12 Q21508RT 1016 3468 103.21 Q22508RT 1345 4590 114.68 900 35 Q11509RT 801 2734 62.85 Q21509RT 1143 3901 114.04 Q22509RT 1513 5164 126.71 1000 39 Q11510RT 890 3038 67.20 Q21510RT 1270 4335 121.19 Q22510RT 1681 5737 134.66 1100 43 Q11511RT 979 3341 73.04 Q21511RT 1397 4768 128.93 Q22511RT 1849 6311 143.25 1200 47 Q11512RT 1068 3645 78.89 Q21512RT 1524 5201 142.11 Q22512RT 2017 6885 157.91 1300 51 Q11513RT 1157 3949 88.92 - - - - Q22513RT 2185 7458 180.81 1400 55 Q11514RT 1246 4253 95.81 Q21514RT 1778 6068 181.19 Q22514RT 2353 8032 201.33 1500 59 Q11515RT 1335 4556 102.34 - - - - Q22515RT 2522 8606 213.04 1600 63 Q11516RT 1424 4860 108.90 Q21516RT 2032 6935 202.91 Q22516RT 2690 9180 225.42 1800 71 Q11518RT 1602 5468 121.74 Q21518RT 2286 7802 226.63 Q22518RT 3026 10327 251.80 2000 79 Q11520RT 1780 6075 134.51 - - - - Q22520RT 3362 11475 276.57 2200 87 - - - - - - - - Q22522RT 3699 12622 304.24 All outputs quoted are based on a Δ T of 50 C. List price excludes VAT. Product codes in bold are available from stock.

Hi-Lo Round Top 07 T11 T21 T22 Nominal Length Single Convector Double Panel Plus Double Convector Height mm inch Code Watts BTU/hr List Price Code Watts BTU/hr List Price Code Watts BTU/hr List Price 600mm 24 300 12 Q11603RT 311 1061 73.52 Q21603RT 438 1495 101.63 Q22603RT 583 1989 128.16 400 16 Q11604RT 414 1414 63.26 - - - - Q22604RT 777 2653 117.04 500 20 Q11605RT 518 1768 48.57 Q21605RT 730 2491 82.62 Q22605RT 972 3316 91.81 600 24 Q11606RT 622 2122 56.14 Q21606RT 876 2990 93.27 Q22606RT 1166 3979 103.65 700 28 Q11607RT 725 2475 62.07 Q21607RT 1022 3488 103.96 Q22607RT 1360 4642 115.50 800 31 Q11608RT 829 2829 67.11 Q21608RT 1168 3986 123.67 Q22608RT 1554 5305 127.05 900 35 Q11609RT 932 3182 72.15 Q21609RT 1314 4485 131.51 Q22609RT 1749 5968 137.41 1000 39 Q11610RT 1036 3536 77.98 Q21610RT 1460 4983 140.94 Q22610RT 1943 6631 146.11 1100 43 Q11611RT 1140 3889 85.15 Q21611RT 1606 5481 155.67 Q22611RT 2137 7295 156.60 1200 47 Q11612RT 1243 4243 92.27 Q21612RT 1752 5980 187.64 Q22612RT 2332 7958 172.95 1300 51 Q11613RT 1347 4597 100.98 - - - - Q22613RT 2526 8621 208.48 1400 55 Q11614RT 1450 4950 110.75 Q21614RT 2044 6976 231.62 Q22614RT 2720 9284 226.07 1600 63 Q11616RT 1658 5657 127.05 Q21616RT 2337 7973 245.39 Q22616RT 3109 10610 257.35 1800 71 Q11618RT 1865 6365 139.11 Q21618RT 2629 8969 259.18 Q22618RT 3497 11937 287.97 2000 79 Q11620RT 2072 7072 157.01 - - - - Q22620RT 3886 13263 318.29 2200 87 - - - - - - - - Q22622RT 4276 14589 350.11 Nominal Length Single Convector Double Panel Plus Double Convector Height mm inch Code Watts BTU/hr List Price Code Watts BTU/hr List Price Code Watts BTU/hr List Price 700mm 28 300 12 Q11703RT 352 1200 79.49 - - - - Q22703RT 658 2244 143.07 400 16 Q11704RT 469 1600 69.84 Q21704RT 655 2235 152.02 Q22704RT 877 2993 128.35 500 20 Q11705RT 586 2000 54.78 Q21705RT 819 2794 134.22 Q22705RT 1096 3741 118.40 600 24 Q11706RT 703 2400 57.87 Q21706RT 982 3352 135.89 Q22706RT 1315 4489 129.87 700 28 Q11707RT 820 2800 65.38 Q21707RT 1146 3911 138.46 Q22707RT 1534 5237 141.32 800 31 Q11708RT 938 3200 70.69 Q21708RT 1310 4470 158.38 Q22708RT 1754 5985 152.78 900 35 Q11709RT 1055 3600 78.36 Q21709RT 1473 5028 173.45 Q22709RT 1973 6733 168.50 1000 39 Q11710RT 1172 4000 85.71 Q21710RT 1637 5587 186.60 Q22710RT 2192 7481 176.87 1100 43 Q11711RT 1289 4400 92.90 - - - - Q22711RT 2411 8229 191.91 1200 47 Q11712RT 1406 4800 101.51 Q21712RT 1964 6704 214.83 Q22712RT 2630 8978 216.78 1400 55 Q11714RT 1641 5600 125.42 - - - - Q22714RT 3069 10474 263.79 1600 63 Q11716RT 1875 6400 139.74 - - - - Q22716RT 3507 11970 305.56 1800 71 Q11718RT 2110 7200 158.30 - - - - Q22718RT 3869 13202 347.60 2000 79 Q11720RT 2344 8000 173.29 - - - - Q22720RT 4299 14669 380.81 All outputs quoted are based on a Δ T of 50 C. List price excludes VAT. Product codes in bold are available from stock.

08 Hi-Lo Compact *Verified by EST: heat output at Δ T50 Cand 30 C for Hi-Lo T11 and T22 Compact radiators (size: 600x1000mm), compared to the main market competitors. Using British Standard testing data from EN 442-1:2014 standard. Correct as of July 2016 and valid until July 2018. All Type 11, 21 and 22 are held in stock. Type 33 are available on a 3 week lead time. HI-LO COMPACT... Boasting the same cutting-edge technology as our Hi-Lo Round Top model, the Hi-Lo Compact comes with pre-fitted grilles and side panels for customers who prefer a more traditional radiator look. Highest heat ouptut (per square metre) - up to 18%* higher than competitor radiators of the same size Lowest water content for fastest heat up time* Unique C-Clip locking mechanism to secure side panels and grille in place Finished with durable epoxy polyester powder paint in white RAL9016 Manufactured and tested in accordance with EN442 Full 10-year warranty Available in a large variety of sizes and styles - single panel single convector (T11), double panel plus (T21), double panel double convector (T22) and triple panel triple convector (T33).

Hi-Lo Compact 09 Bracket Lug Location Mounting Details Note: Dimensions H1, H2 and H3 refer to the lugs on Double Panel Plus and Double Convector radiators. Dimensions J1, J2 and J3 refer to the lugs on Single Convector Radiators. Single Convector T11 Double Panel Plus T21 Double Convector T22 Triple Convector T33 Mounting Details (mm) Radiator height 'B' 300 400 500 600 700 Bracket height 'C' 137 237 337 437 537 Connection centre 'D' 253 353 453 553 653 Bracket Lug Locations (mm) Radiator length 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1800 2000 Tapping-to-tapping A 295 395 495 595 695 795 895 995 1095 1195 1295 1395 1495 1595 1795 1995 H1 72.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 J1 85 135 160 160 160 160 160 160 160 160 160 160 160 160 160 160 H2 150 150 250 350 450 550 650 750 850 950 1050 1150 1250 1350 775 875 J2 125 125 175 275 375 475 575 675 775 875 975 1075 1175 1275 750 850 H3 - - - - - - - - - - - - - - 775 875 J3 - - - - - - - - - - - - - - 725 825 Quantity 4 4 4 4 4 4 4 4 4 4 4 4 4 4 6 6 Water Content Height 300mm 400mm 500mm 600mm 700mm L/m Single Convector 1.81 2.24 2.67 3.10 3.53 Double Panel Plus 3.60 4.47 5.33 6.20 7.07 Double Convector 3.50 4.37 5.23 6.10 7.00 Triple Convector 5.40 6.60 7.80 9.00 10.38 Radiator Dry Weight Height 300mm 400mm 500mm 600mm 700mm kg/m Single Convector 9.50 12.52 15.54 18.56 21.58 Double Panel Plus 16.00 19.92 24.74 29.56 34.38 Double Convector 18.04 24.00 29.97 35.93 41.90 Triple Convector 26.94 35.89 44.84 53.79 62.74 Test pressure: 13 bar Max. operating pressure: 10 bar

10 Hi-Lo Compact T11 T21 Nominal Length Single Convector Double Panel Plus Height mm inch Code Watts BTU/hr List Price Code Watts BTU/hr List Price 300mm 12 600 24 Q11306KD 336 1147 42.72 - - - - 800 31 - - - - - - - - 1000 39 Q11310KD 560 1911 59.09 - - - - 1200 47 Q11312KD 672 2294 70.66 - - - - 1400 55 - - - - - - - - 1600 63 Q11316KD 896 3058 94.89 - - - - 1800 71 Q11318KD 1008 3440 107.54 - - - - 2000 79 Q11320KD 1120 3823 120.20 - - - - Nominal Length Single Convector Double Panel Plus Height mm inch Code Watts BTU/hr List Price Code Watts BTU/hr List Price 400mm 16 400 16 Q11404KD 292 995 37.40 - - - - 500 20 Q11405KD 365 1244 38.63 - - - - 600 24 Q11406KD 437 1493 43.49 - - - - 700 - - - - - - - - - 800 31 Q11408KD 583 1990 51.16 - - - - 900 35 Q11409KD 656 2239 56.62 - - - - 1000 39 Q11410KD 729 2488 60.41 - - - - 1100 43 Q11411KD 802 2737 65.74 - - - - 1200 47 Q11412KD 875 2986 71.06 - - - - 1400 55 Q11414KD 1021 3483 88.85 - - - - 1600 63 Q11416KD 1166 3981 98.07 - - - - 1800 71 Q11418KD 1312 4479 110.41 - - - - 2000 79 Q11420KD 1458 4976 123.40 - - - - Nominal Length Single Convector Double Panel Plus Height mm inch Code Watts BTU/hr List Price Code Watts BTU/hr List Price 500mm 20 300 12 Q11503KD 266 906 35.73 - - - - 400 16 Q11504KD 354 1208 36.70 - - - - 500 20 Q11505KD 443 1510 43.62 - - - - 600 24 Q11506KD 531 1812 49.53 - - - - 700 28 Q11507KD 620 2114 53.90 - - - - 800 31 Q11508KD 708 2416 58.27 Q21508KD 991 3383 99.97 900 35 Q11509KD 797 2718 62.62 - - - - 1000 39 Q11510KD 885 3021 67.00 Q21510KD 1239 4229 117.96 1100 43 Q11511KD 974 3323 74.12 - - - - 1200 47 Q11512KD 1062 3625 81.54 Q21512KD 1487 5074 141.96 1300 51 Q11513KD 1151 3927 89.54 - - - - 1400 55 Q11514KD 1239 4229 97.11 Q21514KD 1735 5920 165.96 1500 59 Q11515KD 1328 4531 104.49 - - - - 1600 63 Q11516KD 1416 4833 107.16 - - - - 1800 71 Q11518KD 1593 5437 120.85 - - - - 2000 79 Q11520KD 1770 6041 134.13 - - - - All outputs quoted are based on a Δ T of 50 C. List price excludes VAT. Product codes in bold are available from stock.

Hi-Lo Compact 11 T22 T33 Nominal Length Double Convector Triple Convector Height mm inch Code Watts BTU/hr List Price Code Watts BTU/hr List Price 300mm 12 600 24 Q22306KD 657 2242 85.00 - - - - 800 31 Q22308KD 876 2990 101.29 - - - - 1000 39 Q22310KD 1095 3737 117.60 - - - - 1200 47 Q22312KD 1314 4485 140.61 - - - - 1400 55 Q22314KD 1533 5232 163.64 - - - - 1600 63 Q22316KD 1752 5980 188.82 - - - - 1800 71 Q22318KD 1972 6727 213.98 - - - - 2000 79 Q22320KD 2191 7474 239.17 - - - - Nominal Length Double Convector Triple Convector Height mm inch Code Watts BTU/hr List Price Code Watts BTU/hr List Price 400mm 16 400 16 - - - - - - - - 500 20 Q22405KD 695 2372 77.28 - - - - 600 24 Q22406KD 834 2846 86.82 - - - - 700 28 Q22407KD 973 3321 95.15 - - - - 800 31 Q22408KD 1112 3795 102.14 - - - - 900 35 Q22409KD 1251 4270 112.67 - - - - 1000 39 Q22410KD 1390 4744 121.87 - - - - 1100 43 Q22411KD 1529 5218 131.01 - - - - 1200 47 Q22412KD 1668 5693 137.40 - - - - 1400 55 Q22414KD 1946 6642 173.35 - - - - 1600 63 Q22416KD 2224 7591 189.74 - - - - 1800 71 Q22418KD 2502 8539 230.18 - - - - 2000 79 Q22420KD 2780 9488 239.35 - - - - Nominal Length Double Convector Triple Convector Height mm inch Code Watts BTU/hr List Price Code Watts BTU/hr List Price 500mm 20 300 12 - - - - - - - - 400 16 Q22504KD 665 2269 69.06 - - - - 500 20 Q22505KD 831 2836 85.53 Q33505KD 1204 4108 244.09 600 24 Q22506KD 997 3403 100.44 Q33506KD 1444 4929 271.26 700 28 Q22507KD 1163 3971 113.44 - - - - 800 31 Q22508KD 1330 4538 122.64 Q33508KD 1926 6572 326.50 900 35 Q22509KD 1496 5105 131.85 - - - - 1000 39 Q22510KD 1662 5672 141.02 Q33510KD 2407 8215 382.11 1100 43 Q22511KD 1828 6240 159.92 - - - - 1200 47 Q22512KD 1994 6807 169.40 Q33512KD 2888 9858 448.35 1300 51 Q22513KD 2161 7374 189.54 - - - - 1400 55 Q22514KD 2327 7941 204.27 Q33514KD 3370 11501 514.53 1500 59 Q22515KD 2493 8509 218.19 - - - - 1600 63 Q22516KD 2659 9076 224.77 Q33516KD 3851 13144 582.54 1800 71 Q22518KD 2992 10210 255.35 Q33518KD 4333 14787 651.12 2000 79 Q22520KD 3324 11345 291.31 Q33520KD 4814 16430 717.33 2200 87 Q22522KD 3656 12479 385.24 - - - - All outputs quoted are based on a Δ T of 50 C. List price excludes VAT. Product codes in bold are available from stock. Non bold product codes are available on a 3 week lead time.

12 Hi-Lo Compact T11 T21 Nominal Length Single Convector Double Panel Plus Height mm inch Code Watts BTU/hr List Price Code Watts BTU/hr List Price 600mm 24 400 16 Q11604KD 412 1408 56.11 - - - - 500 20 Q11605KD 516 1759 59.48 - - - - 600 24 Q11606KD 619 2111 62.36 - - - - 700 28 Q11607KD 722 2463 66.96 - - - - 800 31 Q11608KD 825 2815 73.36 - - - - 900 35 Q11609KD 928 3167 77.81 - - - - 1000 39 Q11610KD 1031 3519 83.26 - - - - 1100 43 Q11611KD 1134 3871 88.68 - - - - 1200 47 Q11612KD 1237 4223 97.49 - - - - 1300 51 Q11613KD 1340 4574 119.22 - - - - 1400 55 Q11614KD 1443 4926 125.87 - - - - 1500 59 - - - - - - - - 1600 63 Q11616KD 1650 5630 140.11 - - - - 1800 71 Q11618KD 1856 6334 152.37 - - - - 2000 79 Q11620KD 2062 7038 172.80 - - - - Nominal Length Single Convector Double Panel Plus Height mm inch Code Watts BTU/hr List Price Code Watts BTU/hr List Price 700mm 28 400 16 - - - - - - - - 500 20 Q11705KD 583 1990 74.61 - - - - 600 24 Q11706KD 700 2388 78.07 - - - - 700 28 - - - - - - - - 800 31 Q11708KD 933 3184 91.85 - - - - 900 35 - - - - - - - - 1000 39 - - - - - - - - 1100 43 Q11711KD 1283 4378 119.24 - - - - 1200 47 - - - - - - - - 1400 55 - - - - - - - - 1600 63 - - - - - - - - 1800 71 - - - - - - - - 2000 79 - - - - - - - - All outputs quoted are based on a Δ T of 50 C. List price excludes VAT. Product codes in bold are available from stock.

Hi-Lo Compact 13 T22 T33 Nominal Length Double Convector Triple Convector Height mm inch Code Watts BTU/hr List Price Code Watts BTU/hr List Price 600mm 24 400 16 Q22604KD 766 2613 111.39 - - - - 500 20 Q22605KD 957 3266 103.62 Q33605KD 1379 4705 273.00 600 24 Q22606KD 1148 3919 117.37 Q33606KD 1654 5646 305.46 700 28 Q22607KD 1340 4573 123.66 - - - - 800 31 Q22608KD 1531 5226 138.11 Q33608KD 2206 7528 371.58 900 35 Q22609KD 1723 5879 143.70 - - - - 1000 39 Q22610KD 1914 6532 158.82 Q33610KD 2757 9410 437.83 1100 43 Q22611KD 2105 7186 167.82 - - - - 1200 47 Q22612KD 2297 7839 188.49 Q33612KD 3308 11292 514.69 1300 51 Q22613KD 2488 8492 220.12 - - - - 1400 55 Q22614KD 2680 9145 251.76 - - - - 1500 59 Q22615KD 2871 9799 262.02 - - - - 1600 63 Q22616KD 3062 10452 266.79 Q33616KD 4411 15055 670.13 1800 71 Q22618KD 3445 11758 299.49 - - - - 2000 79 Q22620KD 3828 13065 332.75 - - - - Nominal Length Double Convector Triple Convector Height mm inch Code Watts BTU/hr List Price Code Watts BTU/hr List Price 700mm 28 400 16 Q22704KD 860 2934 134.65 - - - - 500 20 Q22705KD 1075 3667 142.29 Q33705KD 1537 5244 302.91 600 24 Q22706KD 1289 4401 146.95 Q33706KD 1844 6293 340.46 700 28 Q22707KD 1504 5134 160.03 - - - - 800 31 Q22708KD 1719 5868 172.90 Q33708KD 2458 8391 416.99 900 35 Q22709KD 1934 6601 191.86 - - - - 1000 39 Q22710KD 2149 7335 198.84 Q33710KD 3073 10488 493.33 1100 43 Q22711KD 2364 8068 223.82 - - - - 1200 47 Q22712KD 2579 8801 235.98 Q33712KD 3688 12586 580.79 1400 55 Q22714KD 3009 10268 315.21 - - - - 1600 63 Q22716KD 3438 11735 366.32 Q33716KD 4917 16781 756.06 1800 71 Q22718KD 3868 13202 397.87 - - - - 2000 79 Q22720KD 4298 14669 452.97 - - - - Nominal Length Double Convector Triple Convector Height mm inch Code Watts BTU/hr List Price Code Watts BTU/hr List Price 900MM 35 600 24 Q22906KD 1542 5263 286.89 - - - - 800 31 Q22908KD 2057 7017 357.63 - - - - All outputs quoted are based on a Δ T of 50 C. List price excludes VAT. Product codes in bold are available from stock. Non bold product codes are available on a 3 week lead time.

14 Compla COMPLA... A premium panel radiator with a perfectly smooth front, the Compla is the ideal choice for those looking to achieve a sleek, modern look. Beneath its stylish exterior, it features all the technological benefits of the Hi-Lo Compact, meaning you don t have to choose between appearance and performance. Popular sizes held in stock. 3 week lead time on all other references. Benefits from exceptional third generation technology used in our Hi-Lo Compact Robust build and flat finish makes it easy to fit and simple to clean Finished with durable epoxy polyester powder paint in white RAL9016 Manufactured and tested to BS EN 442 Full 10-year warranty Available in a four heights and nine lengths as single panel single convector, double panel plus and double panel double convector.

Compla 15 Bracket Lug Location Mounting Details Note: Dimensions H1, H2 and H3 refer to the lugs on Double Panel Plus and Double Convector radiators. Dimensions J1, J2 and J3 refer to the lugs on Single Convector Radiators. Single Convector Double Panel Plus Double Convector Mounting Details (mm) Radiator height 'B' 400 500 600 700 Bracket height 'C' 237 337 437 537 Connection centre 'D' 353 453 553 653 Bracket Lug Locations (mm) Radiator length 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1800 2000 Tapping-to-tapping A 295 395 495 595 695 795 895 995 1095 1195 1295 1395 1495 1595 1795 1995 H1 72.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 J1 85 135 160 160 160 160 160 160 160 160 160 160 160 160 160 160 H2 150 150 250 350 450 550 650 750 850 950 1050 1150 1250 1350 775 875 J2 125 125 175 275 375 475 575 675 775 875 975 1075 1175 1275 750 850 H3 - - - - - - - - - - - - - - 775 875 J3 - - - - - - - - - - - - - - 725 825 Quantity 4 4 4 4 4 4 4 4 4 4 4 4 4 4 6 6 Water Content Height 400mm 500mm 600mm 700mm L/m Single Convector 2.10 2.62 3.14 3.67 Double Panel Plus 4.09 5.09 6.10 7.12 Double Convector 4.07 5.08 6.10 7.12 Radiator Dry Weight Height 400mm 500mm 600mm 700mm kg/m Single Convector 14.88 18.40 21.93 25.88 Double Panel Plus 22.37 27.66 32.95 38.47 Double Convector 26.10 32.55 39.00 45.45 Test pressure: 13 bar Max. operating pressure: 10 bar

16 Compla T11 T22 T22 Nominal Length Single Convector Double Panel Plus Double Convector Height mm inch Code Watts BTU/hr List Price Code Watts BTU/hr List Price Code Watts BTU/hr List Price 400mm 16 400 16 Q11404PL 275 934 118.22 Q21404PL 384 1304 148.65 Q22404PL 530 1803 157.01 600 24 Q11406PL 412 1401 132.28 Q21406PL 575 1956 165.17 Q22406PL 796 2705 174.46 800 31 Q11408PL 550 1869 154.44 Q21408PL 767 2608 192.34 Q22408PL 1061 3607 204.49 1000 39 Q11410PL 687 2336 175.18 Q21410PL 959 3261 220.22 Q22410PL 1326 4508 235.95 1200 47 Q11412PL 824 2803 199.49 Q21412PL 1151 3913 254.54 Q22412PL 1591 5410 271.70 1400 55 Q11414PL 962 3270 223.80 Q21414PL 1343 4565 288.15 Q22414PL 1856 6312 307.45 1600 63 Q11416PL 1099 3737 248.11 Q21416PL 1534 5217 321.75 Q22416PL 2122 7213 344.63 1800 71 Q11418PL 1237 4204 277.42 Q21418PL 1726 5869 359.65 Q22418PL 2387 8115 386.82 2000 79 Q11420PL 1374 4672 301.73 - - - - Q22420PL 2652 9017 423.28 Nominal Length Single Convector Double Panel Plus Double Convector Height mm inch Code Watts BTU/hr List Price Code Watts BTU/hr List Price Code Watts BTU/hr List Price 500mm 20 400 16 Q11504PL 328 1114 125.11 Q21504PL 455 1548 150.87 Q22504PL 633 2152 158.73 600 24 Q11506PL 491 1671 146.58 Q21506PL 683 2322 182.33 Q22506PL 949 3227 193.77 800 31 Q11508PL 655 2228 170.89 Q21508PL 910 3095 214.50 Q22508PL 1266 4303 229.52 1000 39 Q11510PL 819 2785 195.20 Q21510PL 1138 3869 247.39 Q22510PL 1582 5379 265.98 1200 47 Q11512PL 983 3342 221.65 Q21512PL 1366 4643 284.57 Q22512PL 1898 6455 306.74 1400 55 Q11514PL 1147 3898 248.11 Q21514PL 1593 5417 322.47 Q22514PL 2215 7530 348.21 1600 63 Q11516PL 1310 4455 275.28 Q21516PL 1821 6191 359.65 Q22516PL 2531 8606 389.68 2000 79 Q11520PL 1638 5569 334.62 - - - - Q22520PL 3164 10758 478.34 Nominal Length Single Convector Double Panel Plus Double Convector Height mm inch Code Watts BTU/hr List Price Code Watts BTU/hr List Price Code Watts BTU/hr List Price 600mm 24 400 16 Q11604PL 378 1287 134.42 Q21604PL 523 1779 165.17 Q22604PL 726 2468 175.18 600 24 Q11606PL 568 1930 161.59 Q21606PL 785 2668 200.92 Q22606PL 1089 3703 215.93 800 31 Q11608PL 757 2573 188.05 Q21608PL 1046 3558 238.10 Q22608PL 1452 4937 256.69 1000 39 Q11610PL 946 3216 214.50 Q21610PL 1308 4447 275.28 Q22610PL 1815 6171 297.44 1200 47 Q11612PL 1135 3860 245.25 Q21612PL 1570 5337 316.75 Q22612PL 2178 7405 343.20 1400 55 Q11614PL 1324 4503 275.28 Q21614PL 1831 6226 358.93 Q22614PL 2541 8639 389.68 1600 63 Q11616PL 1514 5146 305.31 Q21616PL 2093 7116 401.83 Q22616PL 2904 9874 437.58 1800 71 Q11618PL 1703 5790 340.34 Q21618PL 2354 8005 449.02 Q22618PL 3267 11108 489.78 2000 79 Q11620PL 1892 6433 370.37 - - - - Q22620PL 3630 12342 536.25 Nominal Length Single Convector Double Panel Plus Double Convector Height mm inch Code Watts BTU/hr List Price Code Watts BTU/hr List Price Code Watts BTU/hr List Price 700mm 28 400 16 Q11704PL 428 1455 146.58 Q21704PL 588 1999 180.18 Q22704PL 811 2758 191.62 600 24 Q11706PL 642 2183 176.61 Q21706PL 882 2999 220.22 Q22706PL 1217 4137 236.67 800 31 Q11708PL 856 2910 205.21 Q21708PL 1176 3998 260.98 Q22708PL 1622 5516 283.14 1000 39 Q11710PL 1070 3638 235.95 Q21710PL 1470 4998 303.16 Q22710PL 2028 6895 329.62 1200 47 Q11712PL 1284 4366 268.13 Q21712PL 1764 5998 348.21 Q22712PL 2434 8274 380.38 1400 55 Q11714PL 1498 5093 300.30 Q21714PL 2058 6997 388.96 Q22714PL 2839 9653 432.58 All outputs quoted are based on a Δ T of 50 C. List price excludes VAT. Product codes in bold are available from stock. Non bold product codes are available on a 3 week lead time.

Compla 17

18 Ligna LIGNA... Bridging the gap between traditional panel and design radiators, the Ligna has it all: a luxurious look and top-quality performance. As with the rest of the Hi-Lo range, the technology it uses to heat your home is second to none making it the ideal choice for those looking for style and substance. Popular sizes held in stock. 3 week lead time on all other references. Benefits from exceptional third generation technology used in our Hi-Lo Compact Wide range of types and sizes, designed for flexible sizing Finished with durable epoxy polyester powder paint in white RAL9016 Manufactured and tested to BS EN 442 Full 10-year warranty Available in a four heights and nine lengths as single panel single convector, double panel plus and double panel double convector.

Ligna 19 Bracket Lug Location Mounting Details Note: Dimensions H1, H2 and H3 refer to the lugs on Double Panel Plus and Double Convector radiators. Dimensions J1, J2 and J3 refer to the lugs on Single Convector Radiators. Single Convector Double Panel Plus Double Convector Mounting Details (mm) Radiator height 'B' 400 500 600 700 Bracket height 'C' 237 337 437 537 Connection centre 'D' 353 453 553 653 Bracket Lug Locations (mm) Radiator length 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1800 2000 Tapping-to-tapping A 295 395 495 595 695 795 895 995 1095 1195 1295 1395 1495 1595 1795 1995 H1 72.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 J1 85 135 160 160 160 160 160 160 160 160 160 160 160 160 160 160 H2 150 150 250 350 450 550 650 750 850 950 1050 1150 1250 1350 775 875 J2 125 125 175 275 375 475 575 675 775 875 975 1075 1175 1275 750 850 H3 - - - - - - - - - - - - - - 775 875 J3 - - - - - - - - - - - - - - 725 825 Quantity 4 4 4 4 4 4 4 4 4 4 4 4 4 4 6 6 Water Content Height 400mm 500mm 600mm 700mm L/m Single Convector 2.10 2.62 3.14 3.67 Double Panel Plus 4.09 5.09 6.10 7.12 Double Convector 4.07 5.08 6.10 7.12 Radiator Dry Weight Height 400mm 500mm 600mm 700mm kg/m Single Convector 14.88 18.40 21.93 25.88 Double Panel Plus 22.37 27.66 32.95 38.47 Double Convector 26.10 32.55 39.00 45.45 Test pressure: 13 bar Max. operating pressure: 10 bar

20 Ligna T11 T22 T22 Nominal Length Single Convector Double Panel Plus Double Convector Height mm inch Code Watts BTU/hr List Price Code Watts BTU/hr List Price Code Watts BTU/hr List Price 400mm 16 400 16 Q11404PH 275 934 116.21 Q21404PH 384 1304 130.43 Q22404PH 530 1803 137.35 600 24 Q11406PH 412 1401 131.20 Q21406PH 575 1956 156.07 Q22406PH 796 2705 152.60 800 31 Q11408PH 550 1869 152.43 Q21408PH 767 2608 180.80 Q22408PH 1061 3607 177.39 1000 39 Q11410PH 687 2336 165.25 Q21410PH 959 3261 205.30 Q22410PH 1326 4508 202.97 1200 47 Q11412PH 824 2803 186.70 Q21412PH 1151 3913 234.79 Q22412PH 1591 5410 232.17 1400 55 Q11414PH 962 3270 208.12 Q21414PH 1343 4565 264.17 Q22414PH 1856 6312 261.29 1600 63 Q11416PH 1099 3737 229.33 Q21416PH 1534 5217 293.39 Q22416PH 2122 7213 291.22 1800 71 Q11418PH 1237 4204 255.70 Q21418PH 1726 5869 327.80 Q22418PH 2387 8115 325.98 2000 79 Q11420PH 1374 4672 276.97 - - - - Q22420PH 2652 9017 355.97 Nominal Length Single Convector Double Panel Plus Double Convector Height mm inch Code Watts BTU/hr List Price Code Watts BTU/hr List Price Code Watts BTU/hr List Price 500mm 20 400 16 Q11504PH 328 1114 123.87 Q21504PH 455 1548 144.49 Q22504PH 633 2152 140.93 600 24 Q11506PH 491 1671 140.45 Q21506PH 683 2322 172.47 Q22506PH 949 3227 169.69 800 31 Q11508PH 655 2228 162.16 Q21508PH 910 3095 201.27 Q22508PH 1266 4303 199.21 1000 39 Q11510PH 819 2785 183.64 Q21510PH 1138 3869 229.81 Q22510PH 1582 5379 228.49 1200 47 Q11512PH 983 3342 207.06 Q21512PH 1366 4643 262.26 Q22512PH 1898 6455 261.40 1400 55 Q11514PH 1310 4455 230.48 Q21514PH 1593 5417 295.72 Q22514PH 2215 7530 295.24 1600 63 Q11516PH 1310 4455 253.69 Q21516PH 1821 6191 327.91 Q22516PH 2531 8606 328.88 2000 79 Q11520PH 1638 5569 306.71 - - - - Q22520PH 3164 10758 401.40 Nominal Length Single Convector Double Panel Plus Double Convector Height mm inch Code Watts BTU/hr List Price Code Watts BTU/hr List Price Code Watts BTU/hr List Price 600mm 24 400 16 Q11604PH 378 1287 132.27 Q21604PH 523 1779 157.78 Q22604PH 726 2468 155.23 600 24 Q11606PH 568 1930 154.86 Q21606PH 785 2668 189.86 Q22606PH 1089 3703 188.73 800 31 Q11608PH 757 2573 178.50 Q21608PH 1046 3558 222.73 Q22608PH 1452 4937 221.94 1000 39 Q11610PH 946 3216 201.98 Q21610PH 1308 4447 255.34 Q22610PH 1815 6171 254.94 1200 47 Q11612PH 1135 3860 228.44 Q21612PH 1570 5337 291.77 Q22612PH 2178 7405 292.51 1400 55 Q11614PH 1324 4503 254.86 Q21614PH 1831 6226 328.15 Q22614PH 2541 8639 330.01 1600 63 Q11616PH 1514 5146 281.18 Q21616PH 2093 7116 365.51 Q22616PH 2904 9874 368.39 1800 71 Q11618PH 1703 5790 313.25 Q21618PH 2354 8005 408.73 Q22618PH 3267 11108 412.24 2000 79 Q11620PH 1892 6433 339.59 Q21620PH 2616 8894 446.08 Q22620PH 3630 12342 449.67 Nominal Length Single Convector Double Panel Plus Double Convector Height mm inch Code Watts BTU/hr List Price Code Watts BTU/hr List Price Code Watts BTU/hr List Price 700mm 28 400 16 Q11704PH 428 1455 142.18 Q21704PH 588 1999 172.17 Q22704PH 811 2758 169.48 600 24 Q11706PH 642 2183 169.20 Q21706PH 882 2999 208.33 Q22706PH 1217 4137 206.72 800 31 Q11708PH 856 2910 194.82 Q21708PH 1176 3998 244.15 Q22708PH 1622 5516 244.64 1000 39 Q11710PH 1070 3638 221.37 Q21710PH 1470 4998 280.81 Q22710PH 2028 6895 282.35 1200 47 Q11712PH 1284 4366 249.80 Q21712PH 1764 5998 320.22 Q22712PH 2434 8274 323.61 1400 55 Q11714PH 1498 5093 278.19 Q21714PH 2058 6997 361.68 Q22714PH 2839 9653 365.79 All outputs quoted are based on a Δ T of 50 C. List price excludes VAT. Product codes in bold are available from stock. Non bold product codes are available on a 3 week lead time.

Ligna 21

22 LST Available individually packed for delivery and installation of covers at second fix or as a bundle. Available with a one week lead time. LST... Designed specifically for places frequented by children, elderly people and vulnerable adults, our Low Surface Temperature (LST) radiators put health and safety first. The LST radiator combines the most efficient panel radiator on the market today from our Hi-Lo range and our unique LST cover. Conforms to NHS guidelines - ensuring that surface temperature never exceeds 43 C Forward-hinged, lockable covers for safety and easy access Can be ordered as a one box solution for ease (round top emi er, cover, external TRV and lockshield) or separately packed for delivery and installation of covers at second x. Finished with anti-microbial powder coated paint in white RAL9016 Manufactured and tested to BS EN 442 Full 10-year warranty on emi er and cover Optional bottom plinth and TRVs when purchased individually packed. See page 29.

LST 23 Bracket Lug Location Mounting Details Note: Lug positions on 600mm cover length for the single emitter will be 235mm from each end. A third pair of lugs are fixed centrally on radiators 1800mm long and above. Single Emitter Double Emitter (single fin) Double Emitter (double fin) The length of the radiator is 200mm less than the cover. Tapping to tapping dimension is 5mm less than the nominal radiator length. Note: If fitted without a plinth, the minimum cover distance from the floor must be 50mm for the single emitter and the double emitter (single fin) and 100mm for the double emitter (double fin). Bracket Lug Locations (mm) BC 500 650 800 BE (T11/T21) 300 400 500 BE (T22) N/A 300 400 M 105 105 105 N (T11/T21) 105 205 305 N (T22) N/A 105 205 Connection Centres (mm) BE D 300 253 400 353 500 453 Water Content (L/m) Emitter height 300mm 400mm 500mm Single emitter 1.81 2.24 2.67 Double emitter (single fin) 3.50 4.37 5.23 Double emitter (double fin) 3.60 4.47 N/A Total LST Radiator Dry Weight (kg/m) Cover height 500mm 650mm 800mm Single emitter 17.47 22.40 27.47 Double emitter (single fin) 23.13 29.66 36.27 Double emitter (double fin) N/A 27.82 35.35

24 LST BUNDLED... Includes emitter, cover and external TRV and lockshield. Nominal Length Single Convector Double Panel Plus Double Convector Height mm Code Watts BTU/hr List Price Code Watts BTU/hr List Price Code Watts BTU/hr List Price 600 BRLST500611 225 767 254.47 BRLST500621 320 1,090 298.40 - - - - 700 BRLST500711 281 959 266.03 BRLST500721 400 1,363 304.98 - - - - 800 BRLST500811 337 1,151 271.35 BRLST500821 479 1,636 321.08 - - - - 900 BRLST500911 393 1,342 279.58 BRLST500921 559 1,908 326.91 - - - - 500mm 1000 BRLST501011 450 1,534 289.94 BRLST501021 639 2,181 338.00 - - - - 1200 BRLST501211 562 1,918 308.25 BRLST501221 799 2,726 371.57 - - - - 1400 BRLST501411 674 2,301 327.34 BRLST501421 959 3,271 393.75 - - - - 1600 BRLST501611 787 2,685 346.76 BRLST501621 1,119 3,817 418.61 - - - - 1800 BRLST501811 899 3,068 366.65 BRLST501821 1,278 4,362 445.21 - - - - 2000 BRLST502011 1,012 3,452 385.62 BRLST502021 1,438 4,907 469.27 - - - - Nominal Length Single Convector Double Panel Plus Double Convector Height mm Code Watts BTU/hr List Price Code Watts BTU/hr List Price Code Watts BTU/hr List Price 600 BRLST650611 290 988 277.09 BRLST650621 415 1,415 302.93 BRLST650622 451 1,539 319.37 700 BRLST650711 362 1,235 291.44 BRLST650721 519 1,769 313.75 BRLST650722 564 1,924 332.39 800 BRLST650811 434 1,482 303.18 BRLST650821 622 2,123 330.89 BRLST650822 677 2,309 352.22 900 BRLST650911 507 1,729 314.11 BRLST650921 726 2,477 337.63 BRLST650922 790 2,694 360.34 650mm 1000 BRLST651011 579 1,976 334.00 BRLST651021 830 2,831 356.53 BRLST651022 902 3,079 374.01 1200 BRLST651211 724 2,470 355.86 BRLST651221 1,037 3,538 375.83 BRLST651222 1,128 3,849 412.61 1400 BRLST651411 869 2,964 378.85 BRLST651421 1,244 4,246 401.94 BRLST651422 1,354 4,618 440.61 1600 BRLST651611 1,014 3,458 405.57 BRLST651621 1,452 4,954 428.57 BRLST651622 1,579 5,388 471.38 1800 BRLST651811 1,158 3,952 432.59 BRLST651821 1,659 5,661 455.36 BRLST651822 1,805 6,158 503.65 2000 BRLST652011 1,303 4,447 457.33 BRLST652021 1,867 6,369 481.53 BRLST652022 2,030 6,928 533.57 Nominal Length Single Convector Double Panel Plus Double Convector Height mm Code Watts BTU/hr List Price Code Watts BTU/hr List Price Code Watts BTU/hr List Price 600 BRLST800611 352 1,202 302.55 BRLST800621 488 1,666 321.96 BRLST800622 580 1,980 335.52 700 BRLST800711 441 1,503 319.61 BRLST800721 611 2,083 334.55 BRLST800722 726 2,475 354.20 800 BRLST800811 529 1,804 334.31 BRLST800821 733 2,500 354.10 BRLST800822 871 2,970 370.27 900 BRLST800911 617 2,104 353.43 BRLST800921 855 2,916 367.29 BRLST800922 1,016 3,466 385.30 800mm 1000 BRLST801011 705 2,405 365.50 BRLST801021 977 3,333 374.97 BRLST801022 1,161 3,961 404.37 1200 BRLST801211 881 3,006 397.80 BRLST801221 1,221 4,166 419.52 BRLST801222 1,451 4,951 439.76 1400 BRLST801411 1,057 3,607 426.84 BRLST801421 1,465 4,999 447.24 BRLST801422 1,741 5,941 471.34 1600 BRLST801611 1,233 4,208 459.77 BRLST801621 1,709 5,832 469.99 BRLST801622 2,031 6,931 507.07 1800 BRLST801811 1,410 4,810 492.48 BRLST801821 1,954 6,666 501.50 BRLST801822 2,322 7,921 542.89 2000 BRLST802011 1,586 5,411 523.40 BRLST802021 2,198 7,499 530.57 BRLST802022 2,612 8,911 576.38 All outputs quoted are based on a Δ T of 50 C. List price excludes VAT. All product codes available with 1 week lead time. The emitter length equals the cover length less 200mm.

25

26 LST INDIVIDUALLY PACKED... Emitter and cover ordered and packed as individual items. Nominal Nominal Cover Length LST Single Emitter Height mm Product Code Watts BTU/Hr Cover Price Emitter Product Code Emitter Price 600 QRLST500611 225 767 140.51 Q11304RT 53.11 700 QRLST500711 281 959 177.83 Q11305RT 62.30 800 QRLST500811 337 1151 210.50 Q11306RT 65.56 900 QRLST500911 393 1342 214.30 Q11307RT 94.94 500mm 1000 QRLST501011 450 1534 187.57 Q11308RT 81.46 1200 QRLST501211 562 1918 248.88 Q11310RT 88.41 1400 QRLST501411 674 2301 264.73 Q11312RT 96.35 1600 QRLST501611 787 2685 284.67 Q11314RT 140.45 1800 QRLST501811 899 3068 312.17 Q11316RT 136.09 2000 QRLST502011 1012 3452 344.09 Q11318RT 147.55 Nominal Nominal Cover Length LST Single Emitter Height mm Product Code Watts BTU/Hr Cover Price Emitter Product Code Emitter Price 600 QRLST650611 290 988 179.82 Q11404RT 44.94 700 QRLST650711 362 1235 174.01 Q11405RT 34.65 800 QRLST650811 434 1482 204.23 Q11406RT 40.30 900 QRLST650911 507 1729 211.66 Q11407RT 44.94 650mm 1000 QRLST651011 579 1976 219.11 Q11408RT 48.58 1200 QRLST651211 724 2470 244.05 Q11410RT 57.97 1400 QRLST651411 869 2964 257.83 Q11412RT 69.64 1600 QRLST651611 1014 3458 329.53 Q11414RT 85.71 1800 QRLST651811 1158 3952 364.11 Q11416RT 97.06 2000 QRLST652011 1303 4447 402.66 Q11418RT 108.25 Nominal Nominal Cover Length LST Single Emitter Height mm Product Code Watts BTU/Hr Cover Price Emitter Product Code Emitter Price 600 QRLST800611 352 1202 175.46 Q11504RT 53.44 700 QRLST800711 441 1503 184.53 Q11505RT 38.18 800 QRLST800811 529 1804 190.95 Q11506RT 44.48 900 QRLST800911 617 2104 214.91 Q11507RT 50.92 800mm 1000 QRLST801011 705 2405 238.87 Q11508RT 57.12 1200 QRLST801211 881 3006 267.80 Q11510RT 67.20 1400 QRLST801411 1057 3607 305.32 Q11512RT 78.89 1600 QRLST801611 1233 4208 352.06 Q11514RT 95.81 1800 QRLST801811 1410 4810 449.34 Q11516RT 108.90 2000 QRLST802011 1586 5411 456.32 Q11518RT 121.74 All outputs quoted are based on a Δ T of 50 C. List price excludes VAT. Product codes in bold are available from stock.

LST 27 Nominal Nominal Cover Length LST Double Emitter (Single Fin) Height mm Product Code Watts BTU/Hr Cover Price Emitter Product Code Emitter Price 600 QRLST500621 320 1090 194.45 Q21304RT 65.40 700 QRLST500721 400 1363 201.36 Q21305RT 71.58 800 QRLST500821 479 1636 226.74 Q21306RT 77.77 900 QRLST500921 559 1908 251.91 Q21307RT 83.94 500mm 1000 QRLST501021 639 2181 243.13 Q21308RT 91.64 1200 QRLST501221 799 2726 254.20 Q21310RT 102.54 1400 QRLST501421 959 3271 293.03 Q21312RT 119.97 1600 QRLST501621 1119 3817 330.56 Q21314RT 137.40 1800 QRLST501821 1278 4362 374.61 Q21316RT 155.20 2000 QRLST502021 1438 4907 447.61 Q21318RT 170.60 Nominal Nominal Cover Length LST Double Emitter (Single Fin) Height mm Product Code Watts BTU/Hr Cover Price Emitter Product Code Emitter Price 600 QRLST650621 415 1415 175.70 Q21404RT 73.59 700 QRLST650721 519 1769 198.26 Q21405RT 81.71 800 QRLST650821 622 2123 213.74 Q21406RT 89.79 900 QRLST650921 726 2477 235.02 Q21407RT 97.89 650mm 1000 QRLST651021 830 2831 256.71 Q21408RT 106.10 1200 QRLST651221 1037 3538 319.98 Q21410RT 123.66 1400 QRLST651421 1244 4246 312.17 Q21412RT 143.64 1600 QRLST651621 1452 4954 387.07 Q21414RT 164.89 1800 QRLST651821 1659 5661 428.15 Q21416RT 186.56 2000 QRLST652021 1867 6369 455.00 Q21418RT 209.24 Nominal Nominal Cover Length LST Double Emitter (Single Fin) Height mm Product Code Watts BTU/Hr Cover Price Emitter Product Code Emitter Price 600 QRLST800621 488 1666 191.53 Q21504RT 57.61 700 QRLST800721 611 2083 211.11 Q21505RT 67.80 800 QRLST800821 733 2500 223.56 Q21506RT 80.93 900 QRLST800921 855 2916 224.61 Q21507RT 95.46 800mm 1000 QRLST801021 977 3333 249.76 Q21508RT 103.21 1200 QRLST801221 1221 4166 284.76 Q21510RT 121.19 1400 QRLST801421 1465 4999 321.12 Q21512RT 142.11 1600 QRLST801621 1709 5832 360.66 Q21514RT 181.19 1800 QRLST801821 1954 6666 428.86 Q21516RT 202.91 2000 QRLST802021 2198 7499 439.49 Q21518RT 226.63 All outputs quoted are based on a Δ T of 50 C. List price excludes VAT. Product codes in bold are available from stock.

28 LST Nominal Nominal Cover Length LST Double Emitter (Double Fin) Height mm Product Code Watts BTU/Hr Cover Price Emitter Product Code Emitter Price 600 QRLST650622 451 1539 171.41 Q22304RT 96.58 700 QRLST650722 564 1924 165.25 Q22305RT 62.25 800 QRLST650822 677 2309 186.16 Q22306RT 79.95 900 QRLST650922 790 2694 221.08 Q22307RT 106.69 650mm 1000 QRLST651022 902 3079 261.60 Q22308RT 113.09 25 1200 QRLST651222 1128 3849 311.89 Q22310RT 127.50 1400 QRLST651422 1354 4618 364.52 Q22312RT 152.39 1600 QRLST651622 1579 5388 380.42 Q22314RT 187.92 1800 QRLST651822 1805 6158 411.96 Q22316RT 199.84 2000 QRLST652022 2030 6928 457.75 Q22318RT 227.02 Nominal Nominal Cover Length LST Double Emitter (Double Fin) Height mm Product Code Watts BTU/Hr Cover Price Emitter Product Code Emitter Price 600 QRLST800622 580 1980 199.68 Q22404RT 64.07 700 QRLST800722 726 2475 214.12 Q22405RT 74.04 800 QRLST800822 871 2970 224.92 Q22406RT 84.11 900 QRLST800922 1016 3466 239.03 Q22407RT 92.98 800mm 1000 QRLST801022 1161 3961 277.60 Q22408RT 103.91 31 1200 QRLST801222 1451 4951 321.74 Q22410RT 119.50 1400 QRLST801422 1741 5941 382.73 Q22412RT 137.59 1600 QRLST801622 2031 6931 418.73 Q22414RT 179.17 1800 QRLST801822 2322 7921 450.01 Q22416RT 209.78 2000 QRLST802022 2612 8911 476.19 Q22418RT 232.61 All outputs quoted are based on a Δ T of 50 C. List price excludes VAT. Product codes in bold are available from stock.

LST Accessories 29 LST OPTIONAL ITEMS... When Barlo LST radiators are ordered with the emitter and cover individually packed, we cover the following options: Thermostatic Radiator Valves Type Code List Price External Valve QTRV001 69.11 Internal Valve TRV005 46.29 Our recommended TRVs consist of a 15mm angle valve body, fitted inside the LST cover with an external or internal TRV head. Internal TRV with sensor External TRV Lockshield Radiator Valves Type Code List Price Lockshield Valve LOCK001 11.74 Optional Bottom Plinths Length Single Emitter Double Emitter Code List Price Code List Price 600 QRLSTP06S 44.07 QRLSTP06D 46.55 700 QRLSTP07S 47.29 QRLSTP07D 49.98 800 QRLSTP08S 50.64 QRLSTP08D 53.74 900 QRLSTP09S 52.79 QRLSTP09D 57.48 1000 QRLSTP10S 56.14 QRLSTP10D 61.22 1200 QRLSTP12S 64.57 QRLSTP12D 70.28 1400 QRLSTP14S 72.96 QRLSTP14D 79.38 1600 QRLSTP16S 79.89 QRLSTP16D 86.79 1800 QRLSTP18S 89.97 QRLSTP18D 97.66 2000 QRLSTP20S 96.89 QRLSTP20D 105.15

30 Radiator Feet RADIATOR FEET... We have a range of feet that can be fitted to panel radiators when the application does not allow for standard wall mounted brackets. Code Description Suitable for Colour List Price per unit TFC04 QRL RADIATOR FEET 400 Radiator height 300-400 White Pricing on request TFC06 QRL RADIATOR FEET 600 Radiator height 300-600 White Pricing on request TFC07 QRL RADIATOR FEET 700 Radiator height 400-700 White Pricing on request TFC08 QRL RADIATOR FEET 800 Radiator height 400-700 White Pricing on request TFC11 QRL RADIATOR FEET 1100 Radiator height 500-900 White Pricing on request TFCSETS QRL FITTING KIT TYPE 11 White Pricing on request TFCSETK QRL FITTING KIT TYPE 22 & 33 White Pricing on request TFCSETM QRL FITTING KIT TYPE 21 & 22 White Pricing on request All feet are sold as a single unit and require a standard fitting kit per foot. Radiators less than 1600mm long require at least 2 feet, radiators over 1800mm long require at least 3 feet. Radiator Foot TFCSETS For Type 11 TFCSETK For Type 21 TFCSETK For Type 22 TFCSETM For Type 22 TFCSETM For Type 33

General Specifications 31 GENERAL SPECIFICATIONS... Material & Finish All Hi-Lo radiators are manufactured from high quality cold-rolled steel with a nominal thickness of 1.2mm. Every Hi-Lo radiator undergoes an intensive pre-treatment process to protect against rust. The radiators are then finished with epoxy polyester powder paint (RAL 9016) which may be over painted if required. Quality All radiators are manufactured under a BS EN ISO 9001:2008 Quality System accepted by BSI. All radiators are manufactured and tested in accordance with BS EN 442. All radiators are individually pressure tested to 13 bar and are suitable for a working pressure up to 10 bar. Packaging Every radiator is protected top and bottom over the whole length and height with heavy cardboard box ends and packed in shrink wrapped polythene. Brackets All radiators are supplied with two or more brackets depending on the length. Two pairs of lugs are fitted on radiators up to and including 1600mm long. A third pair of lugs is fitted centrally on radiators which are 1800mm long and over. Connections Each radiator is manufactured with four 1/2 BSP TBOE connections. All tapping-to-tapping dimensions may be obtained by subtracting 5mm (1/4 ) from the nominal radiator/emitter length. Warranty All radiators are supplied under warranty for a period of ten years in respect of defective materials or manufacture. Feet and accessories are covered by a 2 year warranty. Our warranty statement can be found at qrl-radiators.com. Conversion Information (Δ T factors) The heat outputs quoted in this publication are based on a Δ T50 C. To calculate other operating conditions, the following example should be used: For Δ T factors other than 50 C multiply the catalogue figure by the conversion factor Degrees Centigrade 5 C 0.0501 30 C 0.5148 55 C 1.1319 10 C 0.1234 35 C 0.6290 60 C 1.2675 15 C 0.2091 40 C 0.7482 65 C 1.4065 20 C 0.3039 45 C 0.8720 70 C 1.5487 25 C 0.4061 50 C 1.0000 75 C 1.6940 Degrees Fahrenheit 10 F 0.0387 60 F 0.3975 110 F 0.8741 20 F 0.0953 70 F 0.4857 120 F 0.9787 30 F 0.1614 80 F 0.5778 130 F 1.0861 40 F 0.2346 90 F 0.6734 140 F 1.1959 50 F 0.3136 100 F 0.7722 150 F 1.3081 Δ T factors in C and F other than 50 C (122 F), exponent n = 1.3 Our standard conditions of sale apply to all transactions available on request. Installation For indirect systems or closed circuits only at a working pressure not exceeding 10 bar. It is strongly recommended on completion of the installation, the system should be properly flushed and filled in accordance with the British Standard Code of Practice for the Treatment of Water in Domestic Hot Water Central Heating Systems BS 7593. Use of a corrosion inhibitor is strongly recommended. Failure to observe this recommendation may invalidate the manufacturer s warranty.

32 DESIGN RANGE... Don t forget to offer designer radiators when replacing standard white panel radiators? More people than ever before are adding style to their home: a matching silver fridge and cooker, curtains and quilt,...how about a coloured design radiator? The Barlo Design range can add subtlety, sophistication or outright boldness with its fantastic variety of colours, all on a 3 week lead time. High performance Certified heat output As easy to install as panel radiators

33

034 QRL Radiator Group 11 Gortahurk Road, Tonymore, Derrylin, Co. Fermanagh, BT92 9DD Telephone: 1800 882 332 sales@qrl-radiators.com www.qrl-radiators.com FOLLOW US ON: ALSO PART OF THE QRL RADIATOR GROUP Style and substance Commercial heating specialist April 2018 - HILOBROCHURE-ROI-GENERIC 04-18