MERLIN RANGE GAS DETECTION EQUIPMENT

Similar documents
MERLIN RANGE KITCHEN EQUIPMENT CT1200S CT1250

Boiler Room Control THE MERLIN RANGE GAS DETECTION EQUIPMENT ENGINEERED TO DELIVER EXCEPTIONAL LEVELS OF SAFETY

Product Data Sheet. Merlin GDP2. Gas Safety Products. Merlin GDP2. Installation, operating and maintenance 23/08/2016. S&S Northern Ltd 1

Troubleshooting Guide

Gas Safety Products. Installation, operating and maintenance 23/08/2016. Merlin 1000BH Gas Proving/Gas Detection System

Gas Safety Products. Installation, operating and maintenance. Merlin 1000BH Gas Proving/Gas Detection System

Troubleshooting Guide

Gas Safety Products. Installation, operating and maintenance. Merlin 1000VW+ Gas Interlock, Gas Proving, Electric & Water Isolation System

Gas Safety Products. Installation, operating and maintenance 28/10/2015. Merlin CT1250 Gas Interlock System. S&S Northern Ltd 1

Gas Safety Products. Installation, operating and maintenance 09/05/2016. Merlin CT1650+ Gas Interlock System. S&S Northern Ltd 1

Gas interlock system S & 100 CS

Gas Safety Products. Installation, operating and maintenance. Merlin Gas Detectors. Read these instructions carefully before operating or servicing.

Gas Safety Products. Installation, operating and maintenance. Merlin Gas Detectors. Merlin Gas Detectors. Rev: 09 Date: Product Data Sheet

Building Services Brochure

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. American Gas Safety LLC 1 05/10/2016

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. Rev: 03 Date:

GPPS-evo V3.3. Installation Instructions

Please read this sheet as it contains important information

Gas Safety Products. Installation, operating and maintenance 11/18/2015. Merlin 1000S+ Gas Utility & Electrical Isolation Controller

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

Gas Safety Products. Installation, operating and maintenance. Merlin 1000S+i Gas & Electric Utility Controller. Rev: 03 Date:

Installation Instructions. The SEC-L is a gas pressure proving system with water and electric isolation, gas detection and ventilation interlock.

UPON COMMENCMENT OF INSTALLATION IT IS OF PARAMOUNT IMPORTANCE THAT THE STEP BY STEP GUIDE (INCLUDED) IS FOLLOWED COMPLETELY

Four Channel Gas Detection System AGDS 4. The Home of Control & Automation in Ireland

GS100M Gas Detection Controller

VGPS-evo V3.3. Installation Instructions. The VGPS-evo is a gas pressure proving system with ventilation interlock and optional CO2 detection.

P R O D U C T D ATA S H E E T

BX444-Mc Gas Detector

GS100M Gas Detector. Technical Specification

IGD.CO.UK

P R O D U C T D ATA S H E E T

Multi Channel Gas Detection System AGDS MC. The Home of Control & Automation in Ireland

Gas Safety Products. Installation, operating and maintenance 11/26/2015. Merlin Gas Detectors. Merlin Gas Detectors. American Gas Safety LLC 1

COSTER. Code Internal Alarm Pre-alarm Suitable sensor threshold threshold external sensor

Fireward Fixed Fire Fighting System. For Open Areas & Enclosed Risks fireward.co.uk

LP GAS LEKAGE ALARM. M. G.. D. D. Wickramasinghe 1*, N. Abhayasinghe 2

GL-CO-RFG Channel Gas Leak Alarm System

WIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions

Gas Safety Products. Installation, operating and maintenance 10/12/2017. Merlin Gas Detectors. Merlin Gas Detectors. American Gas Safety LLC 1

Multi Function Control System for Boiler and Plant rooms SEC-B. The Home of Control & Automation in Ireland

TOCSIN 750 SERIES SAFE AREA GAS DETECTORS. 2-Wire Addressable Systems. 2 Core Cable Unscreened. 6 Standard 20mm Gland Entry Knockouts

A homeowner s guide to the Baxi Neta-tec Combi

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

BX444-M Gas Detector. Features. Application. Operation

Installation Instructions

intelligent solutions

Gas ventilation monitoring and control system

GS300M Gas Detector. Features. Application. Operation

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Sieger Apex. Flexibility that meets your requirements

AlertMaxx2. Installation & Operating Manual. Ground Water (DMS-298) Pump Station High Level Alarm

APPLICATION DATA SHEET

CaterSense 03 & ATSC-02-xx

Space Saver. Installation and user manual SS3 SS5 SS7 SS9. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

Clyde CK40. Cast Iron Boiler. Engineering Data Sheet 663/8 May Natural gas Class D oil Dual Fuel. 350 kw to 500 kw

Zareba Metro Gas Detector

ASHRAE Safety Standards. Mechanical Rooms and Gas Detection in Commercial Applications

GS100M Gas Detector. Features. Application. Operation

Technical Specification

SITE SECURITY THE SMARTER WAY TO PROTECT REMOTE AND TEMPORARY SITES, 24 HOURS A DAY.

Opening up the Gas Market (OGM) Project Oban - Laboratory and Field Testing Results

Electronic Refrigerant Gas Detectors

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Protect Safety Alarms

The CAB & DAB Air Curtains

P R O D U C T D ATA S H E E T

CRU-S Series Stainless Steel Condensate Recovery Unit

Installation and Operating Manual

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

T.ex Single Gas Detector VISA

Zareba Sensepoint Pro

arm wire free solutions nurse call personal security fire alarms

PROTECTION THAT MAKES SENSE Bluetooth Enabled Gas Detector

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

Grant Spira 6-26kW and 9-36kW Wood Pellet Boilers

Gas detector tubes are most effective as a reference device for conducting spot checks, which gives an idea of present gas at that moment in time.

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

P R O D U C T D ATA S H E E T

Ax60+ Multi-Gas. Service Manual

The POWERBOOST. Range GROUP. Clean Water Booster Sets

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Laboratory Furniture

ACCU-TEST SAFETY. Assured Gas Shut Off Protection

PHV-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

OLC(T) 100 FIXED GAS DETECTOR

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04

EMEX 110 and EMEL. EMEX 110 and EMEL. 110, 50 and 24 volt AC/DC Central Battery Systems. EMEX 110 and EMEL

CRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions

INTELLIGENT VENTILATION CONTROLS NATURAL AND HYBRID PLUS SYSTEMS

Ax60+ Multi-Gas, Quick Connect Option

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Understanding the practicalities of using gas detectors in confined spaces

Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces

GAS DETECTION International Gas Detectors CH4 NO

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

Transcription:

MERLIN RANGE GAS DETECTION EQUIPMENT

MERLIN RANGE CONTENTS Merlin GSP1 A single zone gas detection system, the Merlin GSP1 can be configured for a high variety of remote detectors including LPG, natural gas or carbon monoxide. Simple to install the Merlin GSP1 uses four-core low voltage cable to wire in the chosen remote detectors. The remote detectors can then be combined with a number of fusible links wired through in series to create a gas and heat detection system capable for deployment in areas such as boiler houses, car parks, factories or shopping centres. Merlin GSP2 An expansion of the excellent Merlin GSP1 the GSP2 operates on the two zone gas detection having the ability to connect two remote detectors for either multi-area or multi-gas detection. The most common detectors in use are those for carbon monoxide, natural gas or LPG. In combination with this the Merlin gas detection range can incorporate any number of fusible links wired in series to the same terminal for added protection of both property and people. Merlin GSP4 The largest of the GSP range the Merlin GSP4 can be used with up to four gas detectors in a number of combinations. The result is that the Merlin GSP4 is a multi-area, multi gas detection panel that can be combined with fusible links to detect gases such as carbon monoxide, LPG or natural gas along with heat sources. This ensures that the Merlin GSP4 is a highly robust, highly capable, highly reliable gas detection panel capable for deployment in a wide variety of areas from shop floors to industrial boiler houses.

GSP1 GAS DETECTION EQUIPMENT Merlin GSP1 Designed primarily for use in boiler houses the Merlin GSP1 is a single zone gas detection system. The GSP1 functions through the use of attached remote sensors wired back to the panel using 4 core low voltage cabling. The use of remote sensors allows the GSP1 to be configured for detection of a wide variety of gases including Natural Gas, LPG, Carbon Monoxide or if necessary Oxygen Depletion. Additionally the GSP1 panel can also be configured to accept any number of fusible links, wired in series, to detect the presence of heat as well as that of gas. With simple LED indications and the unique UK manufactured design, the Merlin GSP1 gives a clear and concise diagnosis at the build up of a target gas and will indicate the reason for the gas isolation; either a manual emergency stop using either the panel mounted emergency stop button or any one of the remote terminals that can be wired into the system or an automatic emergency stop triggered through the detection of heat or gas. These indicators allow for the problem to be resolved promptly or if required, for emergency action to be taken. The primary purpose of the Merlin GSP1 is to protect both people and property. As such the GSP1 has been designed to be highly compatible with a number of other systems. A prime example of this is the functionality for the GSP1 to be connected to the Building Management System through a volt free terminal allowing a signal to be sent giving instant notification that the gas supply has been isolated. The GSP1 can also interact with the FAB1 system that allows regular fire drills and functionality tests without having to isolate the buildings gas supply. Advantages of Merlin GSP1 Easy to install The use of clearly marked PCB connections, low voltage wiring and push-fit wiring connections makes the GSP1 very simple to install. User Friendly Digital LED design gives clear system indication at all times Will work in conjunction with Building Management Systems through volt free terminals. Fitted with emergency stop as standard with capability to accept any number of additional remote terminals. Totally covered by the S & S Northern 3 year Warranty

MERLIN RANGE Merlin GSP2 An expansion of the excellent Merlin GSP1 the GSP2 operates on the two zone gas detection having the ability to connect two remote detectors for either multi-area or multi-gas detection. As with the GSP1 the most common detectors in use are those for carbon monoxide, natural gas, oxygen depletion or LPG. In combination with this the Merlin gas detection range can incorporate any number of fusible links wired in series to the same terminal for added protection of both property and people. The GSP2 operates through the use of attached remote sensors wired back to the panel using 4 core low voltage cabling. The internal push fit connections make the Merlin GSP range simple to install and maintain and the fascia mounted LED indications combined with the unique UK manufactured design gives a clear and concise diagnosis at the build up of a target gas indicating the reason for the gas isolation; either a manual emergency stop using either the panel mounted emergency stop button or any one of the remote terminals that can be wired into the system or an automatic emergency stop triggered through the detection of heat or gas. These indicators allow for the problem to be resolved promptly or if required, for emergency action to be taken. The Merlin GSP2 can be deployed for in a number of locations such as industrial boiler houses, shopping centres or any enclosed area where the detections of gas is a high priority. The GSP2 has been therefore designed to be a highly robust and highly capable system able to function in numerous environments whilst remaining highly compatible with a number of other systems such as the building management system or the S & S Northern FAB1 Panel. Advantages of Merlin GSP2 Operates over 2 zones allowing multi-gas or multi-area detection. Easy to install The use of clearly marked PCB connections, low voltage wiring and push-fit wiring connections makes the GSP2 very simple to install. User Friendly Digital LED design gives clear system indication at all times Will work in conjunction with BMS and FAB 1 Fitted with emergency stop as standard with capability to accept any number of additional remote terminals. Totally covered by the S & S Northern 3 year Warranty.

GSP2/GSP4 GAS DETECTION EQUIPMENT Merlin GSP4 The largest of the GSP range the Merlin GSP4 can be used with up to four gas detectors in a number of combinations. The result is that the Merlin GSP4 is a multi-area, multi gas detection panel that can be combined with fusible links to detect gases such as carbon monoxide, LPG or natural gas along with heat sources. The GSP4 operates through the use of attached remote sensors wired back to the panel using 4 core low voltage cabling. The Merlin GSP4 can take up to 4 remote detectors giving a wide variety of options for deployment of the system allowing for multiple gases such as Natural Gas, LPG, Oxygen Depletion or Carbon Dioxide with detectors placed at various levels of a single enclosure alternatively the Merlin GSP4 could function by sniffing for a single gas, LPG for example, in four different enclosures. The GSP4, like the other panels in the GSP range is simple to install using push fit electrical terminals, clear LED indications for fault finding and gas supply and integration with BMS systems or the Merlin FAB1. The fascia mounted emergency stop can be combined with remote emergency terminals to fully cover emergency procedures and as such fulfil all required guidelines and legislations. The panel is UK manufactured with a UK based technical support team that offer the impeccable service that S & S Northern prides itself on. Advantages of Merlin GSP4 Operates over 4 zones allowing multi-gas or multi-area detection. Easy to install The use of clearly marked PCB connections, low voltage wiring and push-fit wiring connections makes the GSP2 very simple to install. User Friendly Digital LED design gives clear system indication at all times Will work in conjunction with BMS and FAB 1 Fitted with emergency stop as standard with capability to accept any number of additional remote terminals. Totally covered by the S & S Northern 3 year Warranty

MERLIN RANGE Merlin CT500 The Merlin panel is designed to provide a simple an effective means of isolating a gas, electricity, oil or water by means of a key switch on the panel, or in the event of an emergency, by operation of the emergency shut off button. The key operated CT500 is UK manufactured and like all S & S Northern products carries a 3 Year warranty and is fully supported by our technical team. The CT500 has a fascia mounted emergency shut off button fitted as standard and the fascia mounted LEDs give simple and concise information to the operator. The panel is fully compatible with S & S Northern remote emergency stop terminals allowing a large number of emergency terminals to be connected in series and wired back to the panel. The CT500 is an excellent isolation panel. Simple to fit with little maintenance required and is covered by the full support that comes with the entire range of Merlin products. Merlin FAB1 Standing for Fire Alarm Bypass the Merlin FAB1 can be integrated with any of the Merlin suite of products to give the operator the opportunity to temporarily bypass the gas isolation system. With prior notice to a fire alarm test, the operator can turn the spring loaded key to the on position giving an un-interrupted gas supply for between 10 and 45 minutes. During this time the system controlling the gas will ignore shut-off signals from the buildings fire alarm system and allow factors such as heating systems to remain operational. The bypass time can be adjusted using the blue switches inside the panel. During the bypass time gas can still be shut off, pressing the emergency gas shut off button will close the gas solenoid valve.

CT500/FAB1/MISC GAS DETECTION EQUIPMENT Solenoid Valves S & S Northern provide a comprehensive package supplying not only the gas detection equipment and interlock panels but also the remote emergency terminals and a range of solenoid valves for water, oil and gas. The most common product supplied is a solenoid valve for isolation of the gas supply. We supply a large number of valves for use in any area where a gas supply is in place this includes schools, kitchen, plant rooms and even some domestic sites. The valves supplied are all covered by the S & S Northern 3 year warranty and are tested and certified to European Standard EN161 as Class A. The valves are also rated to IP65 thus allowing them to be deployed in wet or dirty environments. Gas Detectors S & S Northern supply a full range of remote gas detectors and thermal links to compliment the Merlin range of panels. The Natural gas detectors should be located approximately 30cm from the ceiling and at detection will go into alarm at 10% of the low explosion level. This will trigger isolation of the power supply to the solenoid and as such isolation of the gas supply. This can then be rectified by resolving the leak, allowing the sensor head to clear and resetting the attached Merlin panel. The Carbon Monoxide Detector is normally situated approximately 1 meter from ground level as Carbon Monoxide is a denser gas. When the sensor head detects carbon monoxide at a level exceeding 50ppm for over 4 minutes the attached system will trigger into the alarm state. This is resettable by rectifying any gas leak, allowing the sensor head to clear and restarting the Merlin panel. LPG detectors are fitted at approximately 50cm from ground height in order to detect any LPG build up. The detector should be installed at low level as LPG build up occurs from the ground upwards due to the dense nature of the gas. At 10% of the low explosion level the detector will trigger the attached Merlin system causing an alarm state and instant isolation of the gas valve. This can only be reset by finding the source of the build up, allowing the sensor head to clear, and resetting the attached Merlin panel. Oxygen Depletion Oxygen depletion detectors are used to protect personnel against nitrogen build up. Oxygen should read 21% in normal atmospheres, a drop below 18% will cause the attached Merlin panel to enter the alarm state. For heat detection the Merlin range accepts input from Fusible Links. Each panel will accept a number of links, wired in circuit. Each Fusible link should be positioned over the boiler or chosen hazard and will trigger the alarm state for the chosen panel at detection of a temperature of 72 degrees centigrade.

For latest prices and delivery to to your door visit MyTub Ltd Ltd - - www.mytub.co.uk - - info@mytub.co.uk MERLIN RANGE 1 2 3 4 5 6 7 Merlin GSP1 Wiring Diagram 1 230v AC Supply 2 230v AC output to valve 3 Terminal for detector - (use 4 core wire) 4 Remote Emergency Stop input 5 Input for Thermal Links (normally closed) 6 24v output when in alarm for emergency beacon 7 Normally closed contact (open in alarm for BMS) Merlin GSP1 Dimensions Height 140 mm Length 190 mm Depth 62 mm

For latest prices and delivery to to your door visit MyTub Ltd Ltd - - www.mytub.co.uk - - info@mytub.co.uk WIRING DIAGRAMS GAS DETECTION EQUIPMENT 1 2 3 3 4 5 6 7 Merlin GSP2 Wiring Diagram 1 230v AC Supply 2 230v AC output to valve 3 Terminals for detector - (use 4 core wire) 4 Remote Emergency Stop input 5 Input for Thermal Links (normally closed) 6 24v output when in alarm for emergency beacon 7 Normally closed contact (open in alarm for BMS) Merlin GSP2 Dimensions Height 140 mm Length 190 mm Depth 62 mm

For latest prices and delivery to to your door visit MyTub Ltd Ltd - - www.mytub.co.uk - - info@mytub.co.uk MERLIN RANGE 1 1 2 3 4 5 5 5 5 6 7 Merlin GSP4 Wiring Diagram 1 Volt free normally closed contact opens in alarm 2 24v output when in alarm for emergency beacon 3 Remote Emergency Stop Input 4 Input for Thermal Links (normally closed) 5 Terminals for detectors - (use 4 core wire) 6 230v AC output to valve 7 230v AC Supply Merlin GSP4 Dimensions Height 180 mm Length 255 mm Depth 64 mm

WIRING DIAGRAMS GAS DETECTION EQUIPMENT Other Safety & Services in our range The gas detection equipment is only a small part of the Merlin range. Here at S&S Northern we pride ourselves on not only first rate customer service but in developing a wide range of market beating products. The Merlin range also covers all aspects of commercial catering with an array of products available to cover the BS6173 standard for gas safety. Our kitchen models such as the best selling CT1250 are sweeping the market with systems in place to protect the health of kitchen staff all over the country, including the House of Lords and Hells Kitchen. We also manufacture and supply a full range of gas pressure proving systems for use in laboratory type applications. The Merlin 1000GD carries out a gas pressure test at start-up ensuring there are no gas leaks or appliances open. The Merlin 1000GDplus not only controls the gas but also the bench electrics. Finally the Merlin 1000GDWplus controls the gas, bench electrics and water solenoid valves. Details on all these products can be supplied on request. We value every customer we have here at S&S Northern and as such are dedicated to ensuring that you are satisfied with our products. As such we are constantly developing and testing new products and when combined with our 3 year warranty and in-house UK based technical team we do all we can to show you why S&S Northern are specialist in gas safety and detection. S&S Northern Ltd Unit 2 Dickinsons Industrial Estate Moss Lane Coppull Chorley PR7 5AL T 01257 470 983 F 01257 471 937 E info@snsnorthern.com South East Division: T 01702 291 725 F 01702 299 148

for safety & service contact: s&s northern head office: unit 2 - dickinsons industrial estate - coppull - chorley - PR7 5AL t 01257 470 983 f 01257 471 937 e info@snsnorthern.com w www.snsnorthern.com southern division: 42 towerfield road - shoeburyness - essex - SS3 9QT t 01702 291 725 f 01702 299 148