INTRODUCTION: COOLING TOWER INTRODUCTION: COOLING TOWER FANS. The cooling Tower is commissioned since 2006 and 1 st failure was encountered in 2007

Similar documents
Vibration Of Cooling Tower Fans. Barry T. Cease Cease Industrial Consulting Vibration Institute 2015

CASE HISTORY#1 BAD COOLING TOWER GEARBOX? Barry T. Cease Cease Industrial Consulting (843)

CASE STUDY ANALYSIS OF CENTRIFUGAL FAN HIGH AMPLITUDE VIBRATION. Ken Singleton

Marley X7 Fan USER MANUAL DESIGNED FOR INDUCED-DRAFT COOLING TOWER APPLICATIONS

Owners Manual. SM-HP A SM-HP8-10 Meter. Manual D

Marley Ultra Quiet Fan

Incinerator Air Blower Repetitive Failures. Authors : RasGas Company Limited

ultra quiet fan USER MANUAL INSTALLATION OPERATION MAINTENANCE

SC250X FLOOR GRINDER OPERATIONS MANUAL

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

Case Study: Preventing Reactor Feed-water 1X Vibration by the Addition of Axial Clearance in the Rotating Assembly

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 1000-P FAN SERIES (PNEUMATIC CONTROL) SERIES 1000-H FAN SERIES (HYDRAULIC CONTROL) GEN 2

Removal. CAUTION: Do not let tensioner arm snap back to the freearm position, sever damage may occur to the tensioner.

Operating Instructions & Parts Manual Models 99533, 99532

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original)

24 & 30 Quiet Design Oscillating Wall Mount Fan

SERVICE DATA SHEET (9704) Rev. D

owner s manual & parts list

ISOLATED DIRECT DRIVE PLENUM FAN (IDDP)

42 Kevlar. Instruction Manual. Kichler Lighting 7711 East Pleasant Valley Road P.O. Box Cleveland, Ohio

60" Tulle PatioTM. Instruction Manual. A Kichler Select ceiling fan

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

Wind power Condition Monitoring. Condition Monitoring Systems (CMS) in wind turbines CMS. Authors: Martin Kluge Michael Danitschek

Sunburst. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

Horizontal Split Case Pumps Type U

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

52 DorsetTM. Instruction Manual. Basic Function Wall Control System Included. A Kichler Decor ceiling fan

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Hatteras BayTM. Patio. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

Installation Manual Universal Single-Arm Side-of-Pole Mount UNI-SA/21.5

Select. Sutter PlaceTM. Instruction Manual. A Kichler Select ceiling fan

FitchTM. Instruction Manual. Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go!

Preventative Maintenance Tables

RING BLOW VFZ-e Standard Model Series

Development of Large Size Hybrid Fan

INSTALLATION AND SERVICE MANUAL FOR THE TAC1000-P FAN SERIES (PNEUMATIC CONTROL) TAC1000-H FAN SERIES (HYDRAULIC CONTROL)

Installation Manual Universal Side-of-Pole Mount UNI-SP/02A

SuperKlean Washdown Products

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.


USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE USING & INSTALLING THE FIXED SOLAR PANEL KIT.

52 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

LED. 60 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

ENGINEER S MANUAL No.01

Cable Drum Machine. Operation Manual 40 SERIES. Cleans 2" to 4" lines up to 75' N O T F O R R O O T S

A CASE STUDY ON BOILER TUBE FAILURE AT JPL

60" Hatteras BayTM. Patio. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

LIMITED LIFETIME WARRANTY

A. Codes and Standards that are Standard at the University:

Product Information. Brushes. Drum brace cable

DUST COLLECTOR OPERATION AND SAFETY INSTRUCTIONS FM230 CAUTION: READ THE INSTRUCTION MANUAL BEFORE USING THE APPLIANCE

DOCUMENT CREASING MACHINE

DAGNY LK. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 110V~60Hz

FAN ENGINEERING. Fan Installation, Operation & Maintenance

FAN ENGINEERING. Fan Installation, Operation & Maintenance

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

SAN JUAN FRESH WATER COOLING SYSTEMS

Series P. Installation & Maintenance. Materials: A - CPVC B - Polypropylene C - PVDF

COOLING SYSTEM 1. Section V CONTENTS DATA AND SPECIFICATIONS. Page. Fluid Fan Drive (Silent Flite) 3. Water Pump 4. Radiator 5

THE QUALITY BRAND IN FANS

MK-1080 PAVER SAW OWNER S MANUAL & PARTS MANUAL

USER MANUAL. PEDESTAL FAN (16 Inch)

LINE SET DUCT AND ACCESSORY PRODUCT CATALOG

NHR-25 Feed Hopper with Agitator

ValkyrieTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

A B A B4

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60010BZGTGLD SAFETY PRECAUTION. Canopy. Downrod. Housing. Transmitter CR2032/3V

RING BLOW VFC 8 TH Series

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

Parts List. RevA _85609INST

Installation, Operation and Maintenance Instructions for ThermaFlex Gasketed Plate Heat Exchangers

ChicagoTM. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

Installation Manual Universal Side-of-Pole Mount UNI-SP/01A

52 Lacey LED. Instruction Manual. 6 Speed DC Wall Control System

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015

INSTALLATION MANUAL FOR ROTARY TWIN LOBE (ROOTS) BLOWERS / COMPRESSORS

Installation Manual Universal Top-of-Pole Mount UNI-TP/02

Oreck Edge - Upright Tune-Up & Service Guide 02/26/2010

HENNESSY / HARTLAND / CORBETT. 24 inch STAINLESS STEEL LAUNDRY CABINET MODEL # AXCLDYSS-24 1/23

Fan Blades & Accessories

54" Skye. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

LINE SET DUCT AND ACCESSORY PRODUCT CATALOG

Exploded View - Model J-7020M/J-7040M Miter Cut-off Saw Base

CR A-F-A-E-HQQE 3x400/ HZ

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

INSTALLATION INSTRUCTIONS John Deere One Series; 1023E, 1025R and 1026R Models A HEATER KIT. Figure 1 (General Layout and Parts I.D.

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

FLUSH WATER SAVER DUAL FLUSH KIT

INSTALLATION and OPERATION BALL WASHER, HIGH CAPACITY MODEL NO: BW-022AN

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

CR20-07 A-F-A-E-HQQE 3x400/ HZ

Transcription:

INTRODUCTION: COOLING TOWER The cooling Tower is commissioned since 2006 and 1 st failure was encountered in 2007 The cooling tower is designed to cool the sea water coming from various heat exchangers The specification of the cooling tower is Height: 51m Total air flow: 9264 m 3 /s Base diameter: 70m Inlet Temperature of water: 45C Water flow at inlet: 67.9 T/hr Outlet Temperature of water: 36C No. 1 INTRODUCTION: COOLING TOWER FANS V SECTION- IV D SECTIO N-I SECTION -III P SECTIO N-II Fan Details: 1. The cooling tower has 24 fans (A-X) distributed around 4 sections 2. Specification of the Fans Motor capacity: 160kW Fan speed: 140 RPM Number of blades: 8 Diameter of the blade: 6706 Diameter of the ring: 6760 Distance of the fan from the outer point of the ring: 1229 Angle of the gearbox / blade shaft axis: 5 J No. 2

INTRODUCTION: COOLING TOWER FANS Upper clamp U-Bolt Blade Neck Lower clamp Hub Retaining bolt No. 3 PROBLEM STATEMENT: FAILURE MODES OF FANS (TILL JUNE 13) Blade-Wise Failure Distribution V Section-Wise Failure Distribution 15% 24% Section-I SECTION-IV 37 18% Section-II Section-III D SECTION-I 56 SECTION-III 42 P 43% Section-IV SECTION-II Failure Modes Types 101 18% 19% Blade 8% of total failure J 6% 18% Gearbox Coupling U-Bolt & Clamp 28% 11% Foundation Others No. 4

OBJECTIVE OF THE PROJECT Analyze all the failure modes in details so as to mitigate 1. The root causes of the failures Apply preventive maintenance measures so as to improve 1. The life of the components 2. Thus enhancing the reliability of the cooling tower fans Investigate the design and changes the design if required Analyze the effects of the above changes No. 5 FAULT TREE ANALYSIS OF COOLING TOWER FANS CT Fan Downtime Mistakes in Installation of blade Measurement inaccuracy Lack of expertize Unavailability of state of art measurement system Measurement inaccuracy Blade Failure Rubbing with ring Blade / Shaft Unbalance Blade Vibration U-bolt looseness Blade resonance Large wind speed U-bolt Looseness Ring Eccentricities Foundation Looseness Gearbox issues Shaft Alignment Shaft bending Coupling issues Unbalance Salt deposit on the blade Falling off of the earlier corrective weights Gearbox Issues Frequent start and stop Corrosion Bent shaft of blade Large static time and load Unbalance for large time Two action plans have been initiated to reduce the root causes: Design modification and revised PM Plan No. 6

DESIGN MODIFICATION PLAN Two Fans (Fan H and Fan L) were selected for designs as there were large failures in these fans Existing Fans Prototype -1 Prototype -2 U-Bolt, Nuts and Washers Blades Lighter Clamps Duplex U-bolts, Nuts and Washers Atlac Resin Blades (~7kg lighter than conventional blades) Other components same as existing Fan 1 Hub 2 Hubs 2 numbers of U-bolts per blade (16 number of U-bolts) Gearbox Straight Bolts, Nuts and Washers Blades Heavier Clamps 4 numbers of straight bolts per blade (32 number of U-bolts) Split Gearbox No. 7 PREVENTIVE MAINTENANCE PLAN INITIATIVES: SOME EXAMPLES For further reliability improvements, OEM suggested PM plans were revised using SAFCO s experience and failure mode analysis 15-day PM plan: Regular visual inspection of the fan blades 1-month PM plan: Cleaning the blades : Online washing of blades, Rechecking of blade angle, Integrity checking of U-bolts and clamps Gearbox oil checking Coupling checking 3-month PM plan: Retorquing of the U bolts 1-year PM plan: Replacing the U-bolts and clamps No. 8

RESULTS: DESIGN MODIFICATION Prototype - 2 Prototype - 1 # of Failure 1 (Failed since: 23.11.2013) 1 (Two U-bolts on May 15) Operation time 162 days 763 days Availability 22.2% 99.7% Maintenance time 18 hrs 5 hrs Maintenance Cost 14 times more cost than Prototype 1 Failures of two fans have been reduced drastically From 8% of total failures to less than 1% of total failures Design of Prototype -1 (with change of materials) has been the best design as found from the experimental investigation No. 9 RESULTS: TYPES OF FAILURE IN PROTOTYPE -1 AND -2 Prototype-2 Failure Prototype-1 (Fan L) Failure The rubbing of one blade of Fan H and the ring was found that caused large vibration The Fan L was found to have a broken Duplex U-bolt with crack at the threads (corrosion) and inherent defect However, it has less failure rate No. 10

RESULTS: PREVENTIVE MAINTENANCE PLAN IMPLEMENTATION Total amount of failures in cooling tower fans has been reduced by 56% Maximum Failures are in Fan- K of Section -2 (with 10% of total failures) Failures in Sections as %age of total failures Section-1: 32% Section-2: 32% Section-3: 19% Section-4: 17% Contribution of Section-2 to total number of failures have been reduced due to design modifications of its two important fans (Fan-L and Fan-H) No. 11 CONCLUSION The performance of Fan L (Prototype-1) was satisfactory with respect to that of other fans in Section II Higher availability Higher Mean Time Between Failure The PM plan has been effective in reducing failures by 56% No. 12

FUTURE PLAN The implementation of Fan L design (Prototype-1) in all the fans: It is expected to further improve the reliability of the fans Fan blades will be changed to lighter Atlac Resin Blade (nearly 7 kg lighter blade) U-bolt material will be changed to Duplex type for reducing the corrosion Gearbox and foundation failures are expected to be reduced after the installation of new design due to The new lighter blades (with nearly 56 kg reduction per fan) Lesser unbalance (with PM plan of cleaning of blades) Lesser looseness (with new type of duplex U-bolts and looseness check during PM) Improvement of the structure No. 13