CERTIFICATE OF APPROVAL No ME 5085

Similar documents
CERTIFICATE OF APPROVAL No CF 5236 EMVER PAINTS INDUSTRIES LLC

BS EN 13823: A Report To: Durabuild Technologies Pvt. Limited. Document Reference: Date: 22 nd February Issue No.

CERTIFICATE OF APPROVAL No CF 5635 P3 SRL

BS EN ISO : 2010

EN : A Report To: Poliuretanos S.A. Document Reference: (Issue 2), (Issue 2) & (Issue 4) Date: 13 th February 2015

CERTIFICATE OF APPROVAL No CF 5507 CONSORT ARCHITECTURAL HARDWARE LTD

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1

CERTIFICATE OF APPROVAL No CF 392 EXIDOR LIMITED

CERTIFICATE OF APPROVAL No CF 117 DORMA UK LTD

CERTIFICATE OF APPROVAL No CF 494 HOPPE (UK) LIMITED

IMO Resolution MSC 61(67): Annex 1: Part 2

CERTIFICATE OF APPROVAL No CF 5038 FREEMAN & PARDOE T/A ARROW ARCHITECTURAL

CERTIFICATE OF APPROVAL No CF 5516 ALLGOOD PLC

CERTIFICATE OF APPROVAL No CF 252 GEZE UK LIMITED

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

BS EN ISO : 2010

BS EN ISO : 2010

CERTIFICATE OF APPROVAL No CF 5530 TALLERES DE ESCORIAZA S.A.U.

BS EN ISO 1716: Determination Of The Heat Of Combustion For Building Products

CERTIFICATE OF APPROVAL No CF 520 ASSA ABLOY LTD T/A ASSA ABLOY SECURITY DOORS

BS 476: Part 6: 1989+A1:2009

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

CERTIFICATE OF APPROVAL No CF 850 ZOO HARDWARE LIMITED

CERTIFICATE OF APPROVAL No CF 5350 TAIWAN DAEDALUS DOOR CONTROL CO. LTD

CERTIFICATE OF APPROVAL No CF 5527 TALLERES DE ESCORIAZA S.A.U.

BS 476: Part 6: 1989+A1:2009

Review Fire Test Report

CERTIFICATE OF APPROVAL No CF 391 UNION ARCHITECTURAL HARDWARE

CERTIFICATE OF APPROVAL No CF 388. Allegion (UK) LTD

CERTIFICATE OF APPROVAL No CF 5494 ASSA ABLOY AB

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

Method of test defined in IEC for determining the circuit integrity performance of a cable under fire conditions.

BS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions.

CERTIFICATE OF APPROVAL No CF 5657 UNION ARCHITECTURAL HARDWARE

CERTIFICATE OF APPROVAL No CF 5263 KCC ARCHITECTURAL

CERTIFICATE OF APPROVAL No CF 118 DORMA UK LTD

CERTIFICATE OF APPROVAL No CF 738 ALLEGION (UK) LIMITED

CERTIFICATE OF APPROVAL No CF 114 EXIDOR LIMITED

Test Report: ICL/CR15/11/087

CERTIFICATE OF APPROVAL No CF 252 GEZE UK LIMITED

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited

BS EN : 2001 & IEC :2000

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

CERTIFICATE OF APPROVAL No CF 145 GEZE UK LIMITED

IEC Method of test defined in IEC / -21 for determining the circuit integrity of electric cables under fire conditions

CERTIFICATE OF APPROVAL No. ME 5008 EMIRATES FIRE FIGHTING EQUIPMENT FACTORY LLC (FIREX)

CERTIFICATE OF APPROVAL No CF 5179 LORIENT POLYPRODUCTS LIMITED

CERTIFICATE OF APPROVAL No. ME 5005 EMIRATES FIRE FIGHTING EQUIPMENT FACTORY LLC (FIREX)

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 13 th October Test Sponsor: Tapco Europe Limited

CERTIFICATE OF APPROVAL No CF 5075 EXIDOR LIMITED

CERTIFICATE OF APPROVAL No CF 530 HOPPE (UK) LIMITED

CERTIFICATE OF APPROVAL No CF 418 PROMAT UK LTD

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CERTIFICATE OF APPROVAL No CF 810 HOPPE (UK) LIMITED

CERTIFICATE OF APPROVAL No CF 136

CERTIFICATE OF APPROVAL No CF 388 INGERSOLL RAND SECURITY TECHNOLOGIES - BRITON

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CERTIFICATE OF APPROVAL No CF 5542 ASSA ABLOY SECURITY SOLUTIONS

CERTIFICATE OF APPROVAL No CF 646 EUROSPEC ARCHITECTURAL HARDWARE LIMITED

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

NF X : Parts 1, 2, 3, 4 & 5

CERTIFICATE OF APPROVAL No CF 5506 ALLEGION (UK) LIMITED

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Title: Indicative fire test. WF Report No: /A. Prepared for: Hoody Speaker Hoods Ltd

BS 476: Part 7: 1997 on K-Flex IN Clad Foil. Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, RONCELLO (MB) Italy

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

CERTIFICATE OF APPROVAL No CF 689 BOSS DOOR CONTROLS

Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

CERTIFICATE OF APPROVAL No CF 530 HOPPE (UK) LIMITED

CERTIFICATE OF APPROVAL No CF 5118 ASSA ABLOY LTD

CERTIFICATE OF APPROVAL No CF 267. DORMA UK LIMITED Wilbury Way, Hitchin, Hertfordshire SG4 0AB Tel: Fax:

CERTIFICATE OF APPROVAL No CF 111 INGERSOLL RAND SECURITY TECHNOLOGIES - BRITON

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Classification report

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

TECHNICA DORMA. Controlled. d Door Closing. Closerss. appended hereto:

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

BCTC CARPET TECHNICAL CENTRE

Test Report: ICL/H18/9039 Rev 1

Fire Test Reports for Interpon D Powder Coatings

TFI Report Reaction to fire test

F O C U S D O O R C L O S E R S

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

CERTIFICATE OF APPROVAL No CF 145 GEZE LIMITED

Analysis Report

25 th November Title:

Easy-action Door Closer DORMA TS83

The Fire Resistance Performance Of Timber Or Mineral Composite Based Insulated Doorsets When Fitted With D & E Architectural Hardware Spring Hinges

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

Title: The Air Leakage Performance of Timber Doorsets fitted with NOR710 Smoke Seals in Accordance with BS 476: Part 31, Section 31.

Fire propagation over combustible exterior facades exposed to intensified flame in Japan

Transcription:

CERTIFICATE OF APPROVAL No ME 5085 1 Suite No. 52, 5 th Floor, Martin Burn Building, 1 RN Mukherjee Road, Kolkata- 700001 (West Bengal), India Tel: +91 33 40276600 Have been assessed against the requirements of the test standard(s) denoted below and are approved for use subject to the conditions appended hereto: CERTIFIED PRODUCT TEST STANDARD ALUDECOR- Firewall EN 13501-1 Signed and sealed for and on behalf of Exova (UK) Limited trading as Warrington Certification Sir Ken Knight Chairman Impartiality Committee Paul Duggan Certification Manager Page 1 of 5

Approved Manufacturing Location Aludecor Lamination Pvt. Ltd. Plt No. 31 A, Sector-11, II-E Sidcul, Ranipur, Bhel, Haridwar, Uttarakhand-249403 India Certification Evidence Certification Evidence 1. This certificate relates to the reaction to fire classification of the product ALUDECOR- Firewall a coated fire rated aluminium composite panel, when tested and classified in accordance with EN 13501-1: 2009, Fire classification of construction products and building elements Part 1: Classification using data from reaction to fire tests. 2. The certification is issued on the basis of: i) Initial type testing of a sampled test specimen. Sampling conducted during FPC audit on the 28 th November 2016 ii) Inspection and surveillance of factory production control iii) Certification of Quality Management Systems to ISO 9001:2008 Initial Type Testing evidence listed in the table: Name of Laboratory Exova warringtonfire Name of sponsor Aludecor Lamination Pvt. Ltd Test report Nos. WF 377553, WF 377551, WF 377550, WF 377549 Test method EN 13823 WF 377543 EN ISO 11925-2 WF 378709 EN/TS 15117 WF 378710 EN 13501-1 3. The products are composite panels, having an overall thickness of 4mm and a weight per unit area of 7.6kg/m². The panels have a top & bottom coil thickness 0.5mm and a 3mm thick Magnesium Di Hydroxide core. A more detailed product description is given at the end of this document. 4. The test results are only valid for the tested product composition and specimen configuration, as described in section 4.3 Field of application of the classification report. 5. The test and classification results on test are reported in Exova Warringtonfire Classification Report No. WF 378710. Page 2 of 5 Signed

Product performance Product information Reaction to fire classification: B-s1, d0, to EN 13501-1 General description A coated fire rated aluminium composite panel ALUDECOR- Firewall Name of manufacturer Aludecor Lamination Pvt. Ltd. 4mm (stated by sponsor) Weight per unit area 7.6kg/m 2 (stated by sponsor) 8.0kg/m 2 (determined by Exova Warringtonfire) Product configuration Top coat (test face) First coat Aluminium Adhesive Core Adhesive Aluminium Service coat (reverse face) Polyvinylidene fluoride (PVDF) (dependant on colour) Name of manufacturer PPG / Nippon (dependant on colour) Any colour Top coat Number of coats One or two (dependant on colour) (test face) Application rate per coat 25-30g/m 2 (dependant on colour) 1.21-1.25kg/l (dependant on colour) Continued on next page Page 3 of 5 Signed

PU / PVDF (dependant on colour) PU Primer / PVDF Primer Name of manufacturer PPG / Nippon Yellow First coat Number of coats One Application rate per coat 5.7-6.2g/m 2 (dependant on colour) 1.14-1.24kg/l (dependant on colour) Mill finish aluminium coil AA3105 or AA5005 (dependant on colour) Detailed description / Manganese alloy for architectural usage composition details Aluminium Name of manufacturer Hindalco 0.5mm Weight per unit area 2.7-2.72kg/m 2 (dependant on colour) Mill Finish This component is inherently flame retardant Low density polyethylene and ethylene acrylate polymer mix FR Adhesive Film Name of manufacturer Ecoplast Ltd. Adhesive Semi-Translucent Application rate 65g/m 2 Application method Hot roll lamination Curing process Magnesium Di Hydroxide FR-D Detailed description / composition details 72% Inorganic content (Magnesium Di Hydroxide). Remaining content is organic. Name of manufacturer Aludecor Lamination Pvt. Ltd. 3mm Core Weight per unit area 1.60kg/m 2 Off White Trade name of flame MDH retardant of flame Magnesium Di Hydroxide retardant Amount of flame retardant 72% Continued on next page Page 4 of 5 Signed

Polyester service coat Polyester Name of manufacturer PPG Gray Service coat Number of coats One (reverse face) Application rate per coat 8.82-8.33g/m 2 (dependant on colour) 1.19-1.26kg/l (dependant on colour) Mounting and fixing details The specimens were tested with an 80mm air space between them and the calcium silicate board substrate Brief description of manufacturing process There are three processes involved in the production of aluminium composite panel. 1. Pre treatment of aluminium coil 2. Aluminium coil colour coating 3. Lamination of colour coated aluminium coil with fire rated core Note 1: The sponsor was unable to provide this information. Information: 1. The performance relates only to the behaviour of the specimen of the product under the particular conditions of test. They are not intended to be the sole criterion for assessing the potential smoke obscuration or fire hazard of the product in use, nor do they reflect the actual behaviour of the product under real fire conditions. 2. It is the responsibility of the user of the information contained within this document to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use of the product. 3. The performance relates only to the specimens of the product in the form in which they were tested. 4. The approval relates to on-going production. Panel product and/or its immediate packaging shall be identified with the certification mark including the certification number, and the manufacturer s name and the product name or code reference. Page 5 of 5 Signed