Tempra TM / DHC-E Simply the Best. Engineering Excellence. The Finest Tankless Electric Water Heater Available!

Similar documents
Tempra / DHC-E. Simply the Best. The Finest Tankless Electric Water Heater Available! Featuring Advanced Microprocessor Control ENGINEERING EXCELLENCE

Tempra / DHC-E. The Finest Tankless Electric Water Heaters Available! Simply the Best Featuring Advanced Microprocessor Control

Simply the Best For Your Home Comfort. Unlimited Supply of Hot Water

The Finest Tankless Electric Water Heaters Available! Commercial Application Point-of-Use Tankless Electric

Advanced Microprocessor Control The Finest Tankless Electric Water Heaters Available! DHC-E / Tempra

Tempra Series WHOLE HOUSE TANKLESS ELECTRIC WATER HEATERS Whole House Comfort

Tempra Series WHOLE HOUSE TANKLESS ELECTRIC WATER HEATERS. Whole House Comfort. Germany

Simply the Best WHOLE HOUSE COMFORT SAVE WHOLE HOUSE TANKLESS ELECTRIC WATER HEATERS

Simply the Best WHOLE HOUSE COMFORT SAVE WHOLE HOUSE TANKLESS ELECTRIC WATER HEATERS

Flow Factor ~

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL

OPERATION AND INSTALLATION

DHW Tanks Indirect Tanks for Domestic Hot Water. New! Single coil tanks with electric element

OPERATION AND INSTALLATION

OPERATION AND INSTALLATION

Mini V, 1.8 kw, single phase Restricted to 0.32 gpm. Ships with 0.5 gpm aerator

DHC-E TANKLESS ELECTRIC WATER HEATERS INSTALLATION INSTRUCTIONS FOR THE LICENSED PLUMBER AND ELECTRICIAN

INSTALLATION AND OPERATING INSTRUCTIONS

MSRP FOR PLUMBING WHOLESALERS Effective April 1, 2018

ЭКСПЛУАТАЦИЯ И МОНТАЖ ПРОТОЧНЫЕ ВОДОНАГРЕВАТЕЛИ С ЭЛЕКТРОННЫМ УПРАВЛЕНИЕМ

OPERATION & INSTALLATION MANUAL IR-30, IR-234, IR-245, IR-260, IR-288, IR-14K220, IR-18K220. Electric Tankless Hot Water Heater

Installation and Operation Guide

Accelera Heat Pump Water Heaters HEAT PUMP WATER HEATERS

The water heater evolved. Hot water. Perfected.

OPERATION & INSTALLATION MANUAL

2016 PRICE LIST - FOR EXPORT Effective June 15, 2016

Modular Panel System for Radiant Floor Heating.

Series Automatic Hand Dryer. Operating Instructions for the User & Installation Instructions for the Licensed Installer

Installation and Operation Guide

TRONIC 6000C WH17 & WH27 Electric Tankless Water Heaters

TABLE 1. Specifications: Dimensions: 6¼ x 9 5/8 x 2 ¾

Installation and Operation Guide

QUICK START GUIDE 04 WARNING 05 PACK CONTENTS 05 TECHNICAL SPECIFICATIONS 05 ELECTRICAL REQUIREMENTS 05 WIRING DIAGRAM 07 INSTALLATION OPTIONS

Electric Tankless Water Heaters

TABLE 1 Electrical Specifications

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages

SHC 2.5 MINI-TANK ELECTRIC WATER HEATERS CALENTADORES DE AGUA ELÉCTRICOS DE MINI-TANQUE CHAUFFE-EAU ÉLECTRIQUES À MINI-RÉSERVOIR

OPERATION AND INSTALLATION UTILISATION ET INSTALLATION

TABLE 1 Electrical Specifications. Phase

Tankless On Demand Electric Water Heater

Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages

INSTANT-FLOW C-MICRO WATER HEATER

Electric Tankless Water Heaters. Most Advanced Line of Residential & Commercial Instant Heaters. Series

OPERATION AND INSTALLATION

SN Series - Safety Shower Heaters Tankless Water Heating Solutions

SBB 300, 400 S & Sbb 300, 400, 600 Plus

HEATING WATER FOR OVER 50 YEARS

INSTANT-FLOW C-MICRO WATER HEATER

SAVE THESE INSTRUCTIONS

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications

What Size Electric Tankless Water Heater Do I

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

2010 PROCard PowerGuide

Keltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions

DOC // 110V HOT WATER HEATER DOWNLOAD

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

Shop Online Eccotemp.com/products. Store Locator Eccotemp.com/locator. Product Support support.eccotemp.com.

Light Duty Commercial Electric Water Heater

Comfort Series Instant Hot Water System

C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

Bosch Greentherm T9800 SE 199 Gas Tankless Water Heater

Installation Instructions

MultiPlex INNOVATIVE COMPRESSED AIR SOLUTIONS LARGE CAPACITY TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

Instantaneous water heater - Operation and installation instructions

POINT-OF-USE WATER HEATERS

12 kw Electric Tankless Water Heater Troubleshooting Guide

Controlled Energy Corp. 340 Mad River Park Waitsfield, VT TOLL FREE

Stiebel Eltron Renewables

Installation Instructions / Warranty. Massaud

HOT WATER WITH THE SNAP OF A FINGER. Mini Tanks. Basic Heaters. High Capacity Heaters. Model CMT. Model SR, M & E. Model ER Series

Indirect Fired Water Heater

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

28 1/2"* 72.4 cm. (*28 1/2 " to include hinges.) 41 3/4" 106 cm. 27" 68.6 cm. 28 1/2"* 72.4 cm. (includes hinges.) 28 1/2"* 41 3/4" 106 cm

PRO SERIES IMPORTANT SAFETY INFORMATION

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR THE HUBBELL TANKLESS WATER HEATER

Heat Pumps COMFORT NEED IT. When You

S19361F - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

Commercial Hot Water Maker

Tankless Water Heating Solutions Residential and Commercial Applications

Automatic Temperature Controller (ATC)

ECCOTEMP. Point of Use Tankless Water Heaters EP-2.4 / EP-7.0. Installation and Operating Instruction Manual. Shop Online.

ECONOMICAL, EFFICIENT PERFORMANCE

Installation Instructions / Warranty

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

Low kw Electric Tankless Water Heater Troubleshooting Guide

PROVIDES TEPID WATER FOR EMERGENCY SHOWER

Installation Instructions / Warranty. Starck 10111XX XX XX1

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS

THE HEATING BOX. Training Manual. Model KD-HBO100 & KD-HBC100. * KD-HB100 (Open-Loop System) * KD-HBC100 (Close-Loop System)

LARGE CAPACITY, REFRIGERATED COMPRESSED AIR DRYERS WITH TRUE-CYCLING TM OPERATION AND REDUNDANT OPERATING SYSTEMS. MultiPlex.

TRONIC 6000C. Tankless electric whole house water heaters. Models: WH17 / WH27. [en] Installation Manual and Operating Instructions

EZ TANKLESS EZ 101 & 202 OPERATION & INSTALLATION MANUAL

Transcription:

Engineering Excellence The Finest Tankless Electric Water Heater Available! Tempra TM / DHC-E Exclusive Digital Temperature Control Outperforms Bulky Hot Water Tanks Reduces Hot Water Pipe Runs Best Warranty in the Industry Simply the Best 800-582-8423 E-mail: info@stiebel-eltron-usa.com www.stiebel-eltron-usa.com C US For U.S. and Canada ISO 9001 CERTIFIED

Tempra TM Tempra TM / DHC-E Tankless Electric Water Heaters / DHC-E Featuring Advanced Microprocessor Control Control Temperature Simply by Setting a Dial. Set the temperature knob on the front cover, and enjoy water between 86 F (30 C) to 125 F (52 C). Change the desired temperature at anytime. No purchase of a remote selector control is necessary. Advanced microprocessor technology ensures that the water temperature never deviates from the set point. Best Warranty in the Industry. STIEBEL ELTRON has an enviable track record of engineering excellence and product quality. The three years parts warranty is unique in the industry. You can depend on the Tempra / DHC-E for many years to come. Compliance with Codes Made Easy. The water temperature required by codes can simply be dialed in at the unit. The 100% accuracy of the water temperature is guaranteed by sophisticated electronics. No need to worry about mixing valves that go out of adjustment and wear out. No Scalding. The electronic control system in the Tempra / DHC-E does not allow the water temperature to go above 125 F (52 C), which eliminates the possibility that scalding may occur. On the other hand, 125 F (52 C) water is sufficiently hot for most applications.

When Performance Matters Simple Design of Plumbing System. There is no need for a T & P valve, drain or mixing valve. The design of the hot water plumbing system gets very simple and straight forward due to the advances introduced with the Tempra / DHC-E. Sleek Design Fits in Anywhere. Due to its small dimensions and attractive housing the Tempra / DHC-E can be left unconcealed in many applications. Seismic Proof Construction. Tempra / DHC-E is a tankless water heater system, and is thereby not subject to seismic code. There is no need for preventative construction, as required when using a bulky water storage heating system. Limited Warranty (Excerpt): STIEBEL ELTRON, Inc. warrants to the original owner that the Tempra / DHC-E Series Water Heater will be free from defects in workmanship and materials for a period of THREE YEARS from the date of purchase. Should any part(s) prove to be defective during this period, STIEBEL ELTRON, Inc. will be responsible for replacement of the defective part(s) only. STIEBEL ELTRON, Inc. is not responsible for labor charges. Tempra / DHC-E Tankless Electric Water Heaters deliver instant hot water. Tempra / DHC-E efficiencies eliminate wasted time waiting for hot water, while preserving precious water resources.

Simply The Best! Introducing Proprietary Technology Take The Cover Off. We have done our homework. As an international leader in the tankless electric water heating industry, STIEBEL ELTRON is proud to have pioneered this tankless water heating technology. The company s German engineering and manufacturing tradition of excellence means that you can depend on its performance for many years to come. Superior, Reliable Performance. The Tempra has several temperature and flow sensors which feed their readings into the unit s proprietary microprocessor control. Heating elements are engaged in stages, achieving the temperature you desire. The Tempra continually monitors the water temperature it produces. Safety thermal cut-off Display Heater Electronic control module Temperature sensors Flow sensor Cold water connection Hot water connection DHC-E 8, DHC-E 10 Safety thermal cut-off Display Heater Electronic control module Temperature sensors Flow sensor Wiring block Water filter and shut-off valve Tempra 29 & 36

The right size for the application DHC-E and Tempra Models DHC-E 8 DHC-E 10 Tempra 12 Phase 1 1 1 Voltage V 208 240 208 240 208 240 Wattage kw 5.4 7.2 7.2 9.6 9 12 Amperage A 26 30 35 40 44 50 Min. Required circuit breaker size A 40 40 40 50 60 60 Recommended wire size AWG COPPER 8 8 8 8 6 6 Maximum temperature increase above @ 0.75 GPM 49 65 65 87 - - ambient water temp. @ GPM 37 49 49 65 - - @ GPM 25 33 33 44 41 54 @ 2.25 GPM - - - - 27 36 @ 3.00 GPM - - - - 20 27 Min water flow to activate unit GPM/Imin 0.29 / 1.1 0.29 / 1.1 Weight Lb / kg 5.9 / 2.7 15 / 6.8 Nominal water volume Gal 0.13 / 0.51 0.13 / 0.5 Width inch / cm 7 7/8 (20.0) 14 9/16 (37) Height inch / cm 14 3/16 (36.0) 14 1/2 (36.7) Depth inch / cm 4 1/8 (10.4) 4 5/8 (11.6) Working pressure PSI / BAR 150 / 10 150 / 10 Tested to pressure PSI / BAR 300 / 20 300 / 20 Water connections 1 / 2 NPT 3 / 4 NPT, with built in shut-off valve Tempra Models 15 20 24 29 36 Phase 1 1 1 1 1 Voltage V 208 240 208 240 208 240 208 240 208 240 Wattage kw 10.8 14.4 14.4 19.2 18 24 21.6 28.8 27 36 Amperage A 52 60 70 80 88 100 105 120 132 150 Min. Required circuit breaker size A 40 2x40 2 x 50 2 x 50 2 x 60 2 x 60 3 x 50 3 x 50 3 x 60 3 x 60 Recommended wire size AWG COPPER 8 2x8 2 x 8 2 x 8 2 x 6 2 x 6 3 x 8 3 x 8 3 x 6 3 x 6 Maximum temperature increase above @ GPM 49 65 66 88 82 92 92 92 92 92 ambient water temp. @ 2.25 GPM 37 43 44 58 54 73 66 87 82 92 @ 3.00 GPM 25 33 33 44 41 54 49 66 61 82 @ 4.50 GPM - - 22 29 27 37 33 44 41 55 Min water flow to activate unit GPM/Imin 0.58 / 2.2 0.58 / 2.2 0.58 / 2.2 0.87 / 3.3 0.87 / 3.3 Weight Lb / kg 18 / 8.1 18 / 8.1 18 / 8.1 24.25 / 11 24.25 / 11 Nominal water volume Gal 0.26 / 1.0 0.26 / 1.0 0.26 / 1.0 0.39 / 1.5 0.39 / 1.5 Width inch / cm 14 9/16 (37) 21 3/4 (55.2) Height inch / cm 14 1/2 (36.7) Depth inch / cm 4 5/8 (11.6) Working pressure PSI / BAR 150 / 10 Tested to pressure PSI / BAR 300 / 20 Water connections 3 / 4 NPT, with built in shut-off valve * Suitable for supply with up to 107 F / 42 C * Tankless water heaters are considered a non-continuous load * Conductors should be sized to maintain a voltage drop of less than 3% under load

Tempra TM / DHC-E Tankless Electric Water Heaters Tankless Electric Water Heater Sizing Chart Lav. Sink Flow - - GPM 0.75 0.75 DHC E 8 DHC E 10 Tempra 12 15 20 24 29 36 Kitchen Sink Utility Sink - 2.00-2.00 Multi- Sinks 1-1.25 1-1.25 *3 *4 *5 *3 *4 *3 *4 *3 *5 *6 *4 *5 *Max. number of sinks that can be serviced by one unit Single Shower - - 3.00 3.00 Cool (Northern) Climate STIEBEL ELTRON, Inc. 17 West Street, West Hatfield, MA 01088 Phone: (413) 247-3380 (800) 582-8423 Fax: (413) 247-3369 E-mail: info@stiebel-eltron-usa.com Please visit our web site at www.stiebel-eltron-usa.com Distributed by: Warm (Southern) Climate #25, 06